OSDR / PtP Node / PtMP

Terminal / PTMP Hub


GDC-003/34

Installation & Cabling


Manual

Edition 3a
Confidential
The information contained in this document is subject to change without prior notice.

ã INTRACOM S.A. TELECOM SOLUTIONS, 2014. All rights reserved.

All copyright, intellectual and industrial rights in this document and in the technical knowledge it contains
are owned by INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners.

This document is made available to the end users only for their internal use.
No part of this document nor any data herein may be published, disclosed, copied, reproduced,
redistributed by any form or means, electronically or mechanically, or used for any other purpose
whatsoever without the prior written approval of INTRACOM S.A. TELECOM SOLUTIONS.
Information as well as drawings and specifications contained in this document are subject to change
without prior notice.

All trademarks and copyrights mentioned herein are the property of INTRACOM S.A. TELECOM
SOLUTIONS and/or their respective owners.
Any rights not expressly granted herein are reserved.

Printed in Greece.

INTRACOM TELECOM
19.7 km Markopoulou Ave., Peania, Athens, GR 19002
T +30 210 667 1000, F +30 210 667 1001
http://www.intracom-telecom.com
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Contents

1. Introduction.................................................................................................. 5
2. Prior to Installation ...................................................................................... 6
List of Materials (StreetNode PtP Node / PtMP Terminal / PtMP Hub) ........... 7
List of Materials (OSDR Aggregation Hub)..................................................... 9
Connections................................................................................................. 15
Equipment Anchor Points ............................................................................ 19
Site Prerequisites......................................................................................... 20
Recommended Tools................................................................................... 25
3. Installation Procedure ............................................................................... 28
Overview...................................................................................................... 29
Installing the StreetNode PtP Node / PtMP Terminal / PtMP Hub ................ 31
Installing the OSDR Aggregation Hub.......................................................... 41
Installing the PonE Device ........................................................................... 58
Appendix A: Installing StreetNode on a Wall Surface ........................................ 64
Appendix B: Terminating S-FTP Cable ................................................................ 65
Appendix C: Removing StreetNode ..................................................................... 70

1
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

(page intentionally left blank)

2
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Equipment Disposal

Disposal of old electrical and electronic equipment (applicable through the


European Union and other European countries with separate waste collection
systems).
This symbol, found on this product and any of its parts or on its operating
instructions or on its packaging, indicates that electrical and electronic equipment
may not be disposed of as unsorted municipal waste. Instead, this product should
be handed over to applicable collection points for the recycling of electrical and
electronic equipment.
By ensuring the correct disposal of this product, you will help prevent potential
negative consequences to the environment and human health, which could
otherwise be caused by inappropriate disposal of this product.
By recycling, reusing and other forms of recovery of old electrical and electronic
equipment you are making an important contribution to the conservation of natural
resources and to the protection of the environment.
For more information about the recycling of this product, please contact your local
municipal authorities, municipal waste disposal service or the store where you
purchased this product.

Απόρριψη παλαιών ηλεκτρικών και ηλεκτρονικών συσκευών (ισχύει στην


Ευρωπαϊκή Ένωση και άλλες Ευρωπαϊκές χώρες με συστήματα χωριστής
συλλογής απορριμμάτων).
Το σύμβολο αυτό, που απεικονίζεται πάνω στο προϊόν και σε τυχόν εξαρτήματα του
ή στο εγχειρίδιο οδηγιών του ή στη συσκευασία του, δείχνει ότι οι ηλεκτρικές και
ηλεκτρονικές συσκευές, μετά το πέρας της λειτουργίας τους, δεν θα πρέπει να
απορρίπτονται μαζί με τα αστικά απόβλητα. Αντίθετα θα πρέπει να παραδίδονται σε
κατάλληλα σημεία συλλογής για την ανακύκλωση των ηλεκτρικών και ηλεκτρονικών
συσκευών.
Διασφαλίζοντας τη σωστή απόρριψη αυτού του προϊόντος, συνεισφέρετε στην
πρόληψη πιθανών αρνητικών συνεπειών στο περιβάλλον και την ανθρώπινη υγεία,
οι οποίες θα μπορούσαν να προκληθούν από την μη ενδεδειγμένη απόρριψη του
προϊόντος.
Η ανακύκλωση, επαναχρησιμοποίηση και άλλες μορφές αξιοποίησης των παλαιών
ηλεκτρικών και ηλεκτρονικών συσκευών βοηθούν στη διαφύλαξη των φυσικών
πόρων και στην προστασία του περιβάλλοντος.
Για περισσότερες πληροφορίες σχετικά την ανακύκλωση αυτού του προϊόντος,
παρακαλούμε επικοινωνήστε με τις τοπικές δημοτικές αρχές, την υπηρεσία
αποκομιδής αστικών αποβλήτων ή το κατάστημα από το οποίο αγοράσατε το
συγκεκριμένο προϊόν.
Για περισσότερες πληροφορίες, μπορείτε να επικοινωνείτε με το Συλλογικό Σύστημα
Εναλλακτικής Διαχείρισης Αποβλήτων Ηλεκτρικού και Ηλεκτρονικού Εξοπλισμού
“Ανακύκλωση Συσκευών Α.Ε.” (www.electrocycle.gr).

3
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Safety Precautions

WORKING ON THE BUILDING’S ROOF


During stormy weather, do not perform any mechanical
assembling or antenna installation / beaming works on the
building’s roof.

The metal structure of towers / masts is prone to lightning.

RF EXPOSURE
Locally applicable national and international radio safety
requirements must be adhered to when installing the OSDR
aggregation hub.

Please refer to local regulatory authorities for advice on


compliance.

As guidance, regarding an OSDR aggregation hub:


· According to EN 50385 and the relative EU Directives
(1999/519/EC - general public environment & 2004/40/EC
– occupational environment) the OSDR system should be
installed in a location such that it is not possible for
workers or members of the public, in the normal course of
their work or everyday activities, to gain access closer in
front of the antenna than the specified distances in the
table below:

Distance
Band Worker Public
26 GHz
28 GHz
0.5 m 1.0 m
32 GHz
42 GHz

4
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

1. Introduction

Scope This document provides detailed installation instructions on the


following types of equipment and deployment scenarios:

· StreetNode PtP (1) node with fixed antenna orientation.

· StreetNode PtP node with antenna auto-alignment.

· StreetNode PtMP (2) terminal with antenna auto-


alignment.

· StreetNode PtMP hub with fixed antenna orientation and


electrical antenna fine-tuning capabilities.

· OSDR aggregation hub with fixed antenna orientation.

Target The installation procedure described hereinafter can be carried out


audience by any technician with basic skills in the installation of outdoor
electrical equipment.

(1)
Point to Point.
(2)
Point to Multi Point.

5
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

2. Prior to Installation

Contents · List of materials (StreetNode PtP node / PtMP


terminal / PtMP hub).
· List of material (OSDR aggregation hub).
· Connections.
· Site prerequisites.
· Recommended tools.

6
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (StreetNode PtP Node / PtMP


Terminal / PtMP Hub)

Introduction The list of materials is given below. At the installation site, the
technician should first unpack the delivered equipment and then
store the packing material in a safe place for future use.

List of Part Description


materials
StreetNode (1)

Mounting plate and pair


of hose clamps to fasten
StreetNode onto a pole
having diameter between
122 mm and 138 mm.
For smaller pole
diameters, kindly contact
Intracom Telecom.

Kit containing four hex


screws 5x25, four wall
plugs and four lock
washers for fastening
mounting plate and
StreetNode onto a wall
surface.
Cable gland kit for
sealing and securing the
Ethernet cable entry at
the bottom of the
StreetNode.

Continued on next page

(1)
Comes equipped with the AC power module.

7
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (StreetNode PtP Node / PtMP


Terminal / PtMP Hub), Continued

List of
materials
Part Description
(continued)
Screw M5x10 (ISO 7380)
and lock washer with
internal safety pin for
securing StreetNode onto
the mounting plate.
Ethernet cable (S-FTP,
Cat5e, UV-rated, black,
4x2xAWG24).

RJ-45 plugs for terminating


one length of S-FTP cable.

AC power cable that


comes pre-terminated at
StreetNode side. The
open-end side will be
terminated directly onto
the AC distributor or to an
appropriate plug.

8
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (OSDR Aggregation Hub)

Introduction The list of materials is given below. At the installation site, the
technician should first unpack the delivered equipment and then
store the packing material in a safe place for future use.

Equipment Part Description

OSDR all-outdoor single-sector hub for


serving StreetNode PtMP terminals.

Sectoral antenna (to be directly


attached onto the OSDR).

Power over Ethernet (PoE) injection


device for use where AC power supply
is available. For indoor use only.
Packaging also includes an IEC cable
(terminated to EU plug) for connecting
the PoE device to AC Mains.

Continued on next page

9
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (OSDR Aggregation Hub), Continued

Equipment
(continued)
Part Description
PonE device for use at OSDR
installation locations where DC
power supply is already available.(1)
Suitable for outdoor installations.
Packaging also includes
accessories for mounting the PonE
device onto a wall surface.

Continued on next page

(1)
PonE is wired to the OSDR with a single Ethernet cable when the distance between PonE
and OSDR is less than 100 m.
PonE is wired to the OSDR with two Ethernet cables when:
· the distance between PonE and OSDR exceeds 100 m (but is less than 200 m), or
when
· inband and outband management are needed concurrently.

10
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (OSDR Aggregation Hub), Continued

OSDR Part Description


installation kit
Mounting accessories (M4
screws and nuts) for fixing the
antenna onto the OSDR.

Cable gland M20 kit for


protecting the Ethernet cable
entry at the bottom of the
OSDR.
Kit for preparing and
terminating the OSDR
grounding cable.

Cable holder (optional) for


securing and organizing the
cables at the bottom of
OSDR.

Continued on next page

11
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (OSDR Aggregation Hub), Continued

OSDR This mounting kit is used to:


mounting kit
· Support the OSDR aggregation hub / antenna system on
the pole.
· Provide the essential mechanical adjustments of the
OSDR antenna in the elevation and azimuth planes.

Mounting kit parts overview:

Continued on next page

12
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (OSDR Aggregation Hub), Continued

OSDR pole This kit will be used to install the OSDR onto a pole using the
installation kit appropriate pair of hose clamps. Two clamp sizes are supplied for
poles having diameter between:
· 60 mm and 100 mm.
· 100 mm and 120 mm.

PonE pole This kit will be used to install the PonE device onto a pole.
installation kit

Continued on next page

13
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

List of Materials (OSDR Aggregation Hub), Continued

Cables & Part Description


accessories
Ethernet cable (S-FTP,
Cat5e, UV-rated, black,
4x2xAWG24).

PonE DC power cable


(solid core, 2 x 2.5 mm2,
Blue/Brown, PVC 1 kV,
suitable for outdoor use).
PonE grounding cable.
Stranded cable 6 mm2 for
outdoor use (PVC, 450 V,
Yellow / Green).

RJ-45 plugs (one pair) for


S-FTP cable termination.

Greasing paste for


applying to the antenna o-
ring.

Cable ties for outdoor use


(black, 500 mm long, UV
rated).

Installation tool for cable


glands M20.

14
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Connections

StreetNode The picture below shows the connection panel of:


node
· StreetNode PtP node
· StreetNode PtMP terminal
· StreetNode PtMP hub

(the receptacles’ protective caps are not shown):

1 2 3

5
4
6

Item Description Use


1, 2 Electrical Gigabit
interfaces, RJ-45
(GbE1, GbE2) Connection of traffic / inband
management cables. All three
3 Optical Gigabit ports can be used concurrently.
interface, SFP
(GbE3)
4 Power supply input Connection of AC power supply
(PSU) cable.
5 Grounding terminal Connection of the StreetNode
M5 (GND) grounding cable.
6 Status LED (STAT) Indicates the operational status.

Continued on next page

15
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Connections, Continued

OSDR The picture below shows the connection panel of OSDR.


aggregation
hub

Item Description Use


1 Electrical Gigabit Connection of traffic / power
interface, RJ-45 supply / inband management cable
(GbE2) coming from PoE / PonE device.
2 Grounding terminal Connection of the OSDR
grounding cable.
3 Status LED Indication of the operational status.
4 Fast Ethernet Connection of outband
(10/100) interface management / power supply cable
(1)
coming from PoE / PonE device.
5 - Not used.
6 - Not used.
7 Optical Gigabit Installation of SFP and connection
interface, SFP cage of optical cable for carrying traffic /
(GbE1) inband management.
8 BNC receptacle Not used.

Continued on next page

(1)
When connected with PonE (i.e. DC powered FO-HUB), this receptacle can be used to
allow:
· outband management of the FO-HUB, and
· longer distances between the PonE device and FO-HUB (practically x2).

16
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Connections, Continued

PoE device The PoE device accepts the AC Mains voltage (through an IEC
input) and the Ethernet traffic (through the IN port) and outputs the
Ethernet traffic together with superimposed DC voltage (through
the OUT port) toward the OSDR.
PoE also includes three status LEDs located above the RJ-45
ports.

PoE is suitable for indoor use only.


NOTE

Continued on next page

17
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Connections, Continued

PonE device (Below, the PonE is shown opened to view its hidden connection
terminals).

Item Description Use


1 Electrical Connection of the traffic / power
Gigabit supply / inband management cable.
interface, RJ-45 (IN: cable from external Ethernet
(Gbe IN / OUT) Switch, OUT: cable to the OSDR).
2 Fast Ethernet Connection of the outband
(10/100) management / power supply
interface, RJ-45 (secondary run) / cable. (1)
(NMS IN / OUT) (IN: cable from external Ethernet
Switch, OUT: cable to the OSDR).
3 DC power input Connection of the external local DC
(INPUT) power supply cable.
4 Grounding Connection of PonE box to the local
terminal. grounding bar.

(1)
When used, the NMS (IN / OUT) receptacle allows:
· outband management of the OSDR, and
· longer distances between the PonE device and OSDR (practically x2).

18
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Equipment Anchor Points

Introduction StreetNode and OSDR embed anchor points, which:


· Provide extra safety during the elevation and
transportation of equipment onto the pole position.
· Facilitate installer’s task onsite.
Onto these anchor points, appropriate secondary restraint
systems can be installed, inclusive of a lanyard, cable tie, safety
leash, etc.

OSDR’s anchor The handle on top serves as the OSDR’s anchor point:
point

StreetNode’s The upper 10 mm hole located on the safety bracket on the side
anchor point (see below) serves as the StreetNode’s anchor point. This point
can be used to install an appropriate safety leash.

19
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Site Prerequisites

Power supply For the installation location, we assume the existence of an


source appropriate power supply source with the following specifications:
AC Power Supply (StreetNode, OSDR w/ PoE):
· 230 V / 50 Hz (Live / Neutral) for the StreetNode PtP /
PtMP terminal / PtMP hub node – the node will come
equipped with the AC power module.
· 100 V to 240 V / 47 Hz to 63 Hz (Live / Neutral / Earth) for
the OSDR aggregation hub – OSDR will be powered from
the PoE device (supplied).
DC Power Supply (OSDR w/ PonE):
· -40 V to -60 V, which will be applied to the PonE’s INPUT
terminals. OSDR will be powered from the PonE through
the Ethernet interconnection.
· PonE must be connected to the DC distribution board and
more specifically to a magnetic circuit breaker (single-pole
MCB 6 A, 80 V dc, B-curve for Telecom Applications).

Installation StreetNode PtP / PtMP terminal / PtMP hub:


location
The node can be installed:
· either on a pole, using the mounting plate and the
supplied adjustable hose clamps, or
· on a wall surface, using the mounting plate and the
supplied wall mounting accessories.

OSDR aggregation hub:


The node will be installed on a rooftop and more specifically on a
pole, using the supplied mounting accessories.

PoE device:
The PoE device will be installed indoors close to the OSDR
aggregation hub location. The Ethernet cable length between PoE
device and OSDR should not exceed 100 m.

PonE device:
The PonE device will be installed outdoors close to the OSDR
aggregation hub location.
The Ethernet cable length connecting the PonE device with the
OSDR should not exceed 100 m.
In case of longer distances (up to 200 m), a second Ethernet
cable can be used to interconnect PonE with the OSDR.

Continued on next page

20
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Site Prerequisites, Continued

Grounding A grounding terminal is required close to each StreetNode


equipment installation position. This terminal will electrically
connect the StreetNode PtP / PtMP terminal / PtMP hub / OSDR
node to earth through a low-resistance path to provide protection
during operation.
The available grounding structure should conform to the local
regulations regarding the construction of an appropriate earthing
system for outdoor telecommunication equipment.

AC power cable Routing of the AC power cable, which connects the StreetNode
routing PtP / PtMP terminal / PtMP hub node to the local AC distributor or
socket, should be implemented as prescribed by the local
regulations regarding outdoor electrical installations.

DC power cable Routing of the DC power cable, which connects the PonE device
routing to the OSDR aggregation hub node, should be implemented as
prescribed by the local regulations regarding outdoor electrical
installations.

Continued on next page

21
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Site Prerequisites, Continued

Line Of Sight Prior to installation, the installer must verify LOS availability
(LOS) toward the service area or toward specific StreetNode nodes.
verification
Each StreetNode terminal node needs to be in LOS with the
assigned hub (StreetNode hub or OSDR aggregation hub).
OSDR needs to be tilted downwards, according to radio planning
directives, so that its street-level service footprint includes all the
assigned StreetNode terminal nodes.

Continued on next page

22
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Site Prerequisites, Continued

Antenna 1. OSDR aggregation hub with fixed antenna orientation:


orientation
The antenna orientation of OSDR
should be carried out toward the
planned service area, as specified in
the radio planning document.
OSDR should point down tilt and to
the center of the service area, taking
into account the OSDR antenna’s
narrow beam.

2. StreetNode PtP / StreetNode PtMP terminal


StreetNode PtP node:
The StreetNode PtP node should be
oriented toward the remote end
point.

StreetNode PtMP terminal with


Antenna Auto-alignment Enabled:
The orientation of the StreetNode
antenna is not critical as node has
self-alignment capabilities with an
azimuth adjustment range of 180o.

3. StreetNode PtMP hub:


The orientation of StreetNode PtMP hub antenna should be
carried out following the radio planning directives. The node
should point to the center of an imaginary line connecting the far
left and the far right StreetNode PtMP terminal nodes assigned to
the hub (see schematic below).

Continued on next page

23
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Site Prerequisites, Continued

Power line AC Mains Line (StreetNode, OSDR w/ PoE):


overvoltage
The StreetNode PtP / PtMP terminal / PtMP hub node complies
protection
with the following safety standards:
· ETSI EN 301 489 (1 kV Line-Line, 2 kV Line-Earth).
· EN 60950 – overvoltage category II (2.5 kV).
Running the AC Mains cable for several meters outdoors, and in
premises of frequent strikes of lightning, makes StreetNode node
prone to induced surges and thus failure.
In case of possibility of surges that exceed the 2.5 kV limit,
additional external protection should be considered.
DC Line (OSDR w/ PonE):
Regarding DC power supply operation, OSDR complies with the
following safety standard:
· ETSI EN 301 489 (500 V).

Ethernet line Optionally, an inline surge protection device can be installed in


protection series with the Ethernet cable (carrying traffic / management) to
provide protection against potential surges on the Ethernet line.
Regarding OSDR, this cable is the one connected at the input of
the PoE / PonE device.
The Ethernet line surge protection device is not included in the
product packaging and can be ordered separately.

Maximum cable Below, the recommended maximum lengths are given for all the
lengths cables that will be used in the installation:
Cable Scope Maximum Length
Ethernet Traffic / (DC) 100 m
power /
StreetNode
management.
AC Power Power supply. 100 m
Grounding Connects Depends on the distance
StreetNode between the StreetNode
equipment to the equipment and the grounding
local grounding terminal position, as well as on
system. the recommended wire gauge
to be used.

24
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Recommended Tools

Overview · Equipment installation tools.


· Ethernet cable termination tools.
· Grounding cable termination tools.

Equipment Tool Description


installation
tools Electrical screwdriver
with extension and
allen bits:
· 3 mm (with
internal safety
pin).
· 7 mm (2 Nm)
· 8 mm (2 Nm /
4.2 Nm)

Adjustable torque
wrench with socket
R.13.

U-type wrenches:
· R.13
· R.24

Adjustable torque
spanners:
· R.8 (2 Nm /
4.2 Nm)
· R.7 (2 Nm)

PH-2 screwdriver.

Flat-headed
screwdriver.

Continued on next page

25
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Recommended Tools, Continued

Equipment
installation
Tool Description
tools
(continued)
Drill machine with
appropriate 8 mm
bits (for wall
mounting and for
lamp post
mounting).

Tamper-proof torx
screwdriver T10.

Continued on next page

26
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Recommended Tools, Continued

Ethernet cable
termination Tool Description
tools
Blade

Cable cutter.

Pliers (long nose).

Crimping tool for


terminating S-FTP
cable to RJ-45
jacks.

Ethernet cable
tester.

Grounding Tool Description


cable
termination Crimping tool for
tools ring terminals.

27
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

3. Installation Procedure

Contents · Overview
· Installing StreetNode PtP node / PtMP terminal / PtMP
hub.
· Installing OSDR aggregation hub.

28
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Overview

Introduction The following equipment combinations are possible within a


StreetNode backhaul network:
· StreetNode PtP Node – StreetNode PtP Node,
establishing a PtP link for serving a hard-to-reach, street-
level location.
· OSDR aggregation hub – StreetNode PtMP terminals.
The OSDR, located on a high building, establishes a
service area for serving several street-level StreetNode
PtMP terminals.
· StreetNode PtMP hub – StreetNode PtMP terminals.
The StreetNode PtMP hub is located at street level for
serving several StreetNode PtMP terminals.

Deploying a The procedure to deploy a PtMP service area is as follows:


PtMP service
area Step Action
1 Install the OSDR to an appropriate high position.
2 Down tilt and point the OSDR toward the center of the
service area, as specified in the network planning.
OSDR will have fixed antenna orientation (as
resulted from the node’s specific configuration).
3 Install the StreetNode PtMP terminals at pole locations,
as specified in the network planning.
Pointing of these nodes is not critical as they will
perform antenna auto-alignment during startup.
End of procedure.

Continued on next page

29
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Overview, Continued

Deploying a The procedure to deploy a PtP link is as follows:


PtP link
Step Action
1 Install the StreetNode PtP node on a pole or wall
surface, at the one side of the link.
2 Point this StreetNode PtP node toward the planned
location (where the other StreetNode PtP node will
reside).
3 Install the second StreetNode PtP node on a pole or
wall surface, at the other side of the link.
4 Point the StreetNode PtP node toward the installed
remote StreetNode PtP node.
End of procedure.

Deploying The procedure to deploy PtMP links at street level is as follows:


PtMP links
(street level) Step Action
1 Install the StreetNode PtMP hub node on a pole or wall
surface, at the planned position.
2 Point this StreetNode PtMP hub node toward the center
of an imaginary line connecting the two edge points
where served StreetNode PtMP terminals will reside
(refer to radio planning document).
3 Install the StreetNode PtMP terminal nodes on poles or
wall surfaces, at the locations specified in the network
planning.
4 Point the StreetNode PtMP terminal nodes toward the
assigned hub node.
End of procedure.

30
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub

Overview 1. Installation of mounting plate onto the pole.(1)


2. Installation of StreetNode.
3. Preparation / connection of traffic / grounding / AC power
cables.

Procedure To install StreetNode, proceed as follows:


Step Action
1 First, note down the following information that can be
found onto the label of StreetNode:
· MAC address
· Serial number

2 Install the two supplied hose clamps onto the mounting


plate, as shown below:

Continued on next page

(1)
For instructions on how to install StreetNode on a wall surface, kindly refer to Appendix A:
Installing StreetNode on a Wall Surface.

31
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
3 Using the electrical screwdriver, extension and 7 mm
bit, install the mounting plate and clamps onto the pole.
Beware of the correct positioning of the mounting
plate. The latter must be installed as shown below
and coarsely point toward the planned direction.
Mounting plate’s safety point should be on the right
(see arrow below).
A StreetNode PtMP terminal node must
NOTE have Line Of Sight (LOS) with the
assigned hub.
A StreetNode PtP node must have Line
Of Sight (LOS) with the far-end
StreetNode PtP Node.
Narrow side is
facing up

Toward the
planned
direction

Wide side is
facing down

4 Prior to the elevation and installation on the pole, use


the StreetNode’s anchor point (see arrow below) to
install an appropriate safety leash.

Continued on next page

32
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
5 a. Lift the StreetNode up to the pole.
b. Loosen the four screws at the back of
StreetNode.
c. Insert and slide StreetNode downwards through
the intended mounting plate openings.

Continued on next page

33
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
6 Using the electrical screwdriver, extension and 8 mm
bit, tighten the four screws.

Ensure that StreetNode is fully seated in the


mounting plate before tightening the four screws.

Do not overtighten screws. Adjust the electrical


screwdriver for tightening of M5 screws.

Continued on next page

34
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
7 Using the electrical screwdriver, extension and 3 mm
bit, tighten the safety screw and lock washer (supplied)
into the intended hole on the safety bracket at the side.
This screw secures StreetNode onto the mounting
plate in case an accidental external brute force is
applied.

Do not overtighten screw. Adjust the electrical


screwdriver for tightening of M5 screws.

Continued on next page

35
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
8 From the bottom of StreetNode, unscrew and remove
only those protective caps corresponding to the
receptacles to be used, i.e. from the:
· Receptacle to plug the AC power cable.
· Receptacle(s) to plug the traffic / management
cable(s).

Continued on next page

36
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
9 Prepare the grounding cable and install it onto the
StreetNode’s grounding terminal (see arrow below).
Using the electrical screwdriver with extension and
8 mm bit, tighten the M5 screw.
Do not overtighten. Adjust the electrical screwdriver
for tightening of M5 screws.

10 Install the AC power cable.

Continued on next page

37
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
11 Proceed as below for each electrical traffic cable:

Slide all three parts of the supplied gland over the


StreetNode-facing side of the Ethernet cable.

Terminate both cable ends to RJ-45 jacks


(see Appendix B: Terminating S-FTP Cable).

First install RJ-45 jack, then the cable gland:

Continued on next page

38
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
12 Connect the:
· Ethernet cable(s) to the small cell or the
interconnected StreetNode / OSDR, or the
customer’s Ethernet equipment.
· AC power cable to the respective terminals on
the local AC distributor. In case of availability of
an AC Mains socket, terminate the cable to the
appropriate plug. Termination of the AC power
cable will be as follows:

Insulation Color (Marking) Signal

Black (1) Live

Black (2) Neutral

Yellow / Green Earth

Continued on next page

39
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the StreetNode PtP Node / PtMP Terminal /


PtMP Hub, Continued

Procedure
(continued)
Step Action
13 Power up StreetNode and wait until the STAT LED starts
blinking green.
Proper commissioning of the assigned OSDR or
StreetNode PtMP hub or the StreetNode PtP node should
be preceded in order to complete this step successfully.
StreetNode will automatically connect to the network and
will be self-brought into backhaul service.
Throughout the automated process, the functioning of status
LED at the bottom of the StreetNode is as described below:
StreetNode Condition
Status of
STAT LED PtMP
PtP Node PtMP Hub
Terminal
Stable StreetNode is StreetNode
Major alarm.
ON, red idle. is idle.
Antenna
Antenna self- self-
Blinking
alignment in alignment –
red
progress. in
progress.(1)
Reception ok
Stable StreetNode is
– not yet
ON, – muted (i.e. not
invited by the
orange transmitting).
hub.

Blinking Ranging in Waiting for



orange progress. link id.

StreetNode is
StreetNode operational but
Link
Blinking node not all assigned
operational
green operates terminals are
.
normally. synchronized
yet.
StreetNode is
Stable operational and
ON, – – all assigned
green terminals are
synchronized.

End of procedure.

(1)
For the StreetNode PtP node (with fixed antenna orientation), stable ON red indicates
that link is not yet established.

40
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub

Procedure 1. Preparing OSDR (mounting kit).


overview
2. Attaching the antenna onto OSDR.
3. Installing the mounting kit onto pole.
4. Installing the OSDR / antenna assembly.
5. Preparing / installing the Ethernet cable.(1)
6. Preparing / connecting the grounding cable.
7. Installing / cabling the PoE device.

Preparing To prepare the OSDR (using the respective part of the mounting
OSDR kit), proceed as follows:
(mounting kit)

Step Action
1 Using the PH-2 screwdriver, remove the four screws
from the back of the OSDR.

Continued on next page

(1)
This cable carries traffic, management and DC power.

41
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Preparing
OSDR
Step Action
(mounting kit)
(continued) 2 Position the mating plate of the mounting kit at the back
of the OSDR and re-install the four screws.
Take care of the correct positioning of this plate
before fastening. Do not overtighten screws.
As reference, keep the RSSI input at OSDR’s bottom
(see arrow below) for correct positioning.

Continued on next page

42
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Preparing
OSDR
Step Action
(mounting kit)
(continued) 3 Using a flat-headed screwdriver, remove the protective
cap from the traffic receptacle (GbE2) at the bottom of
the OSDR.

4 Using the U-type wrench R.24, install and tighten the


dual-threaded metallic part included in the cable gland
kit (see below).

5 In case two Ethernet cables are used between PonE


& OSDR:
Repeat steps 3 & 4 for the receptacle located next to
GbE2.

End of procedure.
Continued on next page

43
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Attaching the To attach the antenna onto the OSDR, proceed as follows:
antenna (onto
OSDR) Step Action
1 Position the OSDR onto a stable flat surface with the
antenna receptacle facing up.
2 Position and fully hand-tighten the three headless
screws (supplied).
To correctly position the screws, take the OSDR
handle as reference (see bottom arrow below).

Continued on next page

44
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Attaching the
antenna (onto
Step Action
OSDR)
(continued) 3 Install the supplied M4 nuts over all three screws and
tighten for one full turn.

4 Align the antenna’s fastening points over the three


installed screws / nuts.

Continued on next page

45
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Attaching the
antenna (onto
Step Action
OSDR)
(continued) 5 a. Apply greasing paste (supplied) around the
circumference of the sealing o-ring.
b. Slide and position the antenna into the cavity of
the OSDR flange.

Continued on next page

46
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Attaching the
antenna (onto
Step Action
OSDR)
(continued) 6 Hand-tighten all three nuts.

7 Using the adjustable torque spanner R.7, tighten the


three screws. Apply a maximum 2 Nm tightening
torque.

Continued on next page

47
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Attaching the
antenna (onto
Step Action
OSDR)
(continued) 8 a. Position the M4 screw and hand-tighten.
b. Use the adjustable torque spanner R.7 to fully
tighten and secure screw.
Apply a maximum 2 Nm tightening torque.

End of procedure.
Continued on next page

48
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Installing the To install the mounting kit, proceed as follows:


mounting kit
Step Action
1 Install the pole installation kit and fix onto it the azimuth
adjustment plate included in the mounting kit.

Prior to fastening, ensure that the orientation of the


azimuth adjustment plate roughly points toward the
planned direction (see below).

Continued on next page

49
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Installing the
mounting kit
Step Action
(continued)
2 Carry out the assembly on the mounting kit’s plate:
a. Install bracket arm (used for azimuth alignment)
and top cap.

b. Install washers / screw on cap’s top and tighten


using the adjustable torque wrench with socket
R.13. Apply a maximum 20 Nm tightening
torque.

c. Install elevator and side cap (see below, left).


d. Install washers / screw at cap’s side and tighten
using the adjustable torque wrench with socket
R.13. Apply a maximum 20 Nm tightening
torque.

End of procedure.

Continued on next page

50
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Installing the To install the OSDR / antenna assembly, proceed as follows:


OSDR / antenna
assembly
Step Action
1 Use the OSDR’s top handle as an appropriate lifting
point to elevate OSDR onto the pole. You may install a
carabiner for this purpose (not supplied).

Continued on next page

51
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Installing the
OSDR / antenna
Step Action
assembly
(continued) 2 a. Safely carry the OSDR / antenna assembly to
the installation position.
b. Remove the karabiner (previously installed).
c. Install OSDR / antenna onto the assembled
mounting kit by using two screws and four
washers (supplied) at elevator’s side.
d. Tighten the screws by using the adjustable
torque wrench with socket R.13. Apply a
maximum 20 Nm tightening torque.

Continued on next page

52
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Installing the
OSDR / antenna
Step Action
assembly
(continued) 3 a. By using the adjustable torque wrench with
socket R.13, slightly loosen the elevation and
azimuth screws (see below).
b. Carry out small movements in both planes so
that OSDR points toward the center of the
assigned service area.
c. Re-tighten the two adjustment screws. Apply a
maximum 20 Nm tightening torque.

End of procedure.
Continued on next page

53
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Preparing / To prepare / install the Ethernet cable (which carries traffic,


installing the management and DC power), proceed as follows:
Ethernet cable
Step Action
1 Terminate both ends of the S-FTP cable to RJ-45 jacks
(refer to Appendix B: Terminating S-FTP Cable).
2 Pass the remaining items of the cable gland kit through
the RJ-45 jack (OSDR side).
The black item shown below is split-type and can be
installed directly on the cable, without passing it
first through the RJ-45 jack.

3 Insert and install the RJ-45 jack of the cable into the
mating receptacle at the bottom of the OSDR.
Listen for a “click” when inserting. This verifies that
the jack has been secured in place.

Continued on next page

54
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Preparing /
installing the
Step Action
Ethernet cable
(continued) 4 Assemble all the cable gland items together.
Using the U-type wrench R.24, fully tighten the metallic
nut (last item).

In case you need to


unplug the RJ-45 jack,
please take care.
This jack is securely
locked into the mating
receptacle and must
be extracted using the
tip of a screwdriver,
after removing the
gland parts from the
bottom of the OSDR.

End of procedure.
Continued on next page

55
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Preparing / To prepare / connect the grounding cable, proceed as follows:


connecting the
grounding Step Action
cable
1 Using the parts included in the supplied grounding kit
and the crimping tool, construct the grounding kit.
Terminate cable to:
• M5 ring (OSDR side).
• M8 ring (grounding terminal side).

Use the heat shrinkable tube to protect terminations.

2 Using the adjustable torque spanner R.8, fasten the M5


ring at the terminal at the bottom of the OSDR.
Apply a maximum 2 Nm tightening torque.

3 At the other end of the grounding cable, connect the M8


ring to the grounding bar.

End of procedure.
Continued on next page

56
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the OSDR Aggregation Hub, Continued

Installing / To install / connect the PoE device, proceed as follows:


connecting the
PoE device Step Action
1 Mount the PoE device into an appropriate closure that
will provide protection against water penetration.
Use the two fastening points shown below.

2 Plug the supplied AC Mains cord to the PoE device’s


IEC socket.
3 Connect the RJ-45 jack of the traffic cable (coming from
the OSDR) to the OUT receptacle of the PoE device.
4 Connect the RJ-45 jack of the traffic cable (coming from
the WAN) to the IN receptacle of the PoE device.
5 Insert the cord plug to the wall AC Mains socket.
6 After power up, check LED indicators to verify that PoE
device operates normally.
7 Check the LED indicator at the bottom of the OSDR:

Stable ON, red Major alarm.

Stable ON, green FO-HUB is ready.

End of procedure.

57
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the PonE Device

Introduction This procedure will be carried out only in the case that the OSDR
aggregation hub is to be connected to a DC power supply source.
The PonE installation and wiring procedure is as follows:
1. Installation of the PonE device (onto the wall or pole).
2. Connection of PonE to the grounding bar.
3. Wiring of PonE (DC power supply / Ethernet cables).

Removing and Removing the PonE cover:


re-installing the
Use a tamper-proof torx screwdriver T10 to remove the six screws
PonE cover
(see below) and detach the PonE cover.
Be careful not to drop the screws while removing.

Re-installing the PonE cover:


Re-install the cover / six screws and tighten with the tamper-proof
torx screwdriver T10.
Fully tighten screws but do not overtighten. There is danger
to break the enclosure.

Continued on next page

58
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the PonE Device, Continued

PonE cables PonE grounding cable:


terminating
Use the supplied grounding cable. This cable will be stripped at
instructions
the one end and will be terminated onto the preinstalled ring
terminal at the bottom of PonE device.
The other end of the cable will be terminated onto the local
grounding bar.

Ethernet cable(s):
One or two runs of S-FTP cables will be needed to interconnect
the PonE device with the OSDR. For cable termination, refer to
the detailed instructions given in Appendix B.

DC power supply cable:


Use the supplied power cable. This cable will be stripped at the
PonE side and will be terminated onto the power supply terminals
at the bottom of PonE device (INPUT, see below).

(Brown = Positive, Blue = Negative).

The other end of the power supply cable will be terminated onto
an available circuit breaker (MCB), within the DC power
switchboard, as specified in site requirements.

Continued on next page

59
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the PonE Device, Continued

Wall mounting Using the supplied accessories (found in the PonE packaging)
and a drill bit 5 mm, mount the PonE onto a wall surface at the
four points shown below.

To avoid water penetration, ensure that:


· Interfaces always face downwards.
· Cables are neatly bent and arranged in U shape before
entering the PoNE box from the bottom.

Continued on next page

60
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the PonE Device, Continued

Pole mounting Use the PonE pole mounting kit (supplied) to install the PonE as
follows:
a. Install the PonE onto the mounting bracket.

b. Install the two supplied hose clamps and fasteners; tighten


the latter with a flat-headed screwdriver.
Ensure that cable entries are facing downwards.

Continued on next page

61
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the PonE Device, Continued

PonE wiring
overview

(Left diagram: single PonE– OSDR Ethernet interconnection for


lengths up to 100 m,
Right diagram: dual PonE– OSDR Ethernet interconnection for
lengths over 100 m and also for carrying outband management).

Item Element Use


1 Ethernet cable. Connection to the external Ethernet
switch (traffic / inband management).
2 Grounding Connection to the local grounding bar.
cable.
3 Power supply Connection to the local DC power
cable. supply.
4 Ethernet cable. Connection to OSDR (GbE2) for traffic,
inband management and DC power
supply.
5 Ethernet cable. Connection to the external Ethernet
switch (outband management only).
6 Ethernet cable. Connection to OSDR for carrying
outband management and DC power
supply.

Continued on next page

62
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Installing the PonE Device, Continued

Cable fastening Use the PonE’s metallic clamps and cable ties to secure cables as
shown:

63
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix A: Installing StreetNode on a Wall Surface

Materials (All materials listed below are supplied).


required
· Mounting plate.
· Screws 5x25 (x4).
· Wall plugs (x4).
· Lock washers (x4)

Tools required · Drill machine with 8 mm bit.


· Electrical screwdriver with extension and 8 mm bit.
· Spanner R.8.

Procedure To install StreetNode onto a wall surface, proceed as follows:


Step Action
1 With the drill machine (fitted with 8 mm bit), drill four
holes on the wall surface, at a depth of 55 mm.
See illustration below for the four drill positions.
2 Install the four supplied wall plugs.
3 Using the four screws and lock washers, install the
mounting plate onto the wall so that the StreetNode
secure point in on the right (see arrow below).
4 Using the electrical screwdriver, extension and 8 mm
bit, tighten the four screws.
Do not overtighten screws. Adjust the electrical
screwdriver for tightening of M5 screws.
5 Proceed as instructed in pole installation case (step 4
and beyond). Use the spanner 8 mm instead (of the
electrical screwdriver) for fastening StreetNode
onto the mounting plate.
End of procedure.

64
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix B: Terminating S-FTP Cable

Parts of RG-45 The RJ-45 jack (for terminating the S-FTP cable) is composed of
jack two parts:
· the main body and
· the wire guide (with numbering).

(Photo below shows the parts for a pair of RJ-45 jacks).

Continued on next page

65
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix B: Terminating S-FTP Cable, Continued

Termination To terminate the S-FTP cable at each end, proceed as follows:


procedure
Step Action
1 a. Strip 40 mm of outer jacket.
b. Fold shield back (over the jacket).
c. Twist shield wires together and allow 10 mm of
shield to surround jacket’s end.
d. Completely remove the exposed foil.

2 Untwist wire pairs and arrange according to the T-568


standard.

Straight-through cable (concerns the Ethernet cable


connected to PoE’s IN or StreetNode’s traffic input
port):

Cross-over cable (concerns the Ethernet cable


connecting PoE with the OSDR):
(The green set of wires should be switched in place with
the orange set of wires.)

Continued on next page

66
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix B: Terminating S-FTP Cable, Continued

Termination
procedure
Step Action
(continued)
3 Carefully insert the eight wires into the cavity of the wire
guide so that its numbering is visible from the top.

4 Measure 16 mm from the jacket’s end and cut all wires


protruding from the guide.

Continued on next page

67
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix B: Terminating S-FTP Cable, Continued

Termination
procedure
Step Action
(continued)
5 a. Fold back the crimping terminal of the connector.
b. Fully insert wire guide and cable into the
connector’s body until the shield (overlapping
the jacket’s end) reaches the crimping position.

6 Terminate the wires onto the RJ-45 jack.

Continued on next page

68
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix B: Terminating S-FTP Cable, Continued

Termination
procedure
Step Action
(continued)
7 With the pliers, bring the terminal of the connector back,
over the exposed shield, and press gently around the
terminal to form. This will achieve good contact with the
shield.

8 With a wire cutter, trim away any braid leftovers


extending beyond the end of the plug.
When finished, termination should look as below:

9 Using the Ethernet tester, test cable for proper wire


termination and continuity.

End of procedure.

69
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix C: Removing StreetNode

Procedure To remove a StreetNode from a pole, proceed as follows:


Step Action
1 Use the StreetNode’s anchor point (see below) to install
an appropriate safety leash.

This will provide extra safety during StreetNode


removal and transportation.

2 a. Disconnect StreetNode from AC power supply


(power supply side).
b. Remove the Ethernet and power supply cables
from the bottom of the StreetNode.

Continued on next page

70
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix C: Removing StreetNode, Continued

Procedure
(continued)
Step Action
3 Using the electrical screwdriver, extension and 8 mm
bit, remove the safety screw from the side of the
StreetNode.

4 Using the electrical screwdriver, extension and 8 mm


bit, loosen the four screws securing StreetNode on the
mounting plate.

Continued on next page

71
StreetNode PtMP Terminal / PtMP Hub / PtP Node / OSDR
Installation & Cabling Manual – Edition 3.0a

Appendix C: Removing StreetNode, Continued

Procedure
(continued)
Step Action
5 Lift and extract StreetNode.
You can now safely transport StreetNode to ground
level.

End of procedure.

72
Intracom Telecom Regional Contacts

Europe Russia & CIS Middle East & APAC


19.7 km. Markopoulou Ave. 16 Krasnoproletarskaya Str. Building No. 3 Office No. 204
19002 Peania, Athens Bldg.1, Entr.3, Moscow, 127473 P.O. Box 500517, Dubai
Greece Russia Internet City, Dubai
tel.: +30 2106671000 tel.: +7 495 921 4881 United Arab Emirates
fax: +30 2106671001 fax: +7 495 725 3805 tel.: +971 4 362 5666
[email protected] [email protected] fax: +971 4 390 4279
[email protected]

India America Africa


Office No. 507, 5th Floor 11360 Technology Circle Block A, Wedgefield Office Park
Welldone Technology Park Duluth, GA 30097 17 Muswell Road South, Wedgefield
Sohna Road, Gurgaon, Haryana USA Bryanston, 2021, Johannesburg
India tel.: +1 770 295 2500 South Africa
tel.: +91 124 4738500 fax: +1 770 295 2600 tel. (switchboard): +27 11 317 3600
fax: +91 124 4738555 [email protected] fax: +27 11 317 3601
[email protected] [email protected]

www.intracom-telecom.com