0% found this document useful (0 votes)
90 views

Marine Certified Products by Pepperl+Fuchs: Fieldbus

The document lists various fieldbus and remote I/O products certified for marine use from Pepperl+Fuchs, including: - Fieldbus power supplies, power hub motherboards, diagnostic modules, and segment protectors for PROFIBUS and Foundation Fieldbus networks. - Remote I/O stations, backplanes, power supplies, communications units, and I/O modules like digital and analog inputs/outputs for PROFIBUS and Foundation Fieldbus networks. - The I/O modules and remote stations are available in versions for use in Zone 2/safe areas as well as Zone 1 hazardous areas.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
90 views

Marine Certified Products by Pepperl+Fuchs: Fieldbus

The document lists various fieldbus and remote I/O products certified for marine use from Pepperl+Fuchs, including: - Fieldbus power supplies, power hub motherboards, diagnostic modules, and segment protectors for PROFIBUS and Foundation Fieldbus networks. - Remote I/O stations, backplanes, power supplies, communications units, and I/O modules like digital and analog inputs/outputs for PROFIBUS and Foundation Fieldbus networks. - The I/O modules and remote stations are available in versions for use in Zone 2/safe areas as well as Zone 1 hazardous areas.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 10

MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

FIELDBUS

Power Hub with Power Supply Modules

KLD2-FBPS-1.25.360 Fieldbus Power Supply, 25 V/360 mA, stand-alone, DIN-rail mountable


HD2-FBPS-1.25.360 Fieldbus Power Supply, 25 V/360 mA, motherboard based mountable
HD2-FBPS-1.500 Fieldbus Power Supply, 30 V/500 mA, motherboard based mountable
HD2-FBPS-1.23.500 Fieldbus Power Supply, 23 V/500 mA, motherboard based mountable
HD2-FBPS-1.17.500 Fieldbus Power Supply, 17 V/500 mA, motherboard based mountable

Power Hub Motherboard

MB-FB-1R Power Hub Motherboard, 1 channel, redundant


MB-FB-2R Power Hub Motherboard, 2 channels, redundant
MB-FB-4 Power Hub Motherboard, 4 channels
MB-FB-4R Power Hub Motherboard, 4 channels, redundant
MBHD-FB-4R Power Hub Motherboard, high-density design, 4 channels, redundant

Advanced Diagnostic Module (ADM) for Power Hub

Advanced Diagnostic Module, auxiliary module for


HD2-DM-A
physical layer diagnostics, motherboard mountable

Segment Protector

Fieldbus distribution interface, Segment Protector with trunk short circuit


R2-SP-N4
protection, 4 channels, for cabinet and enclosed installation
Fieldbus distribution interface, Segment Protector with trunk short circuit
R2-SP-N6
protection, 6 channels, for cabinet and enclosed installation
Fieldbus distribution interface, Segment Protector with trunk short circuit
R2-SP-N8
protection, 8 channels, for cabinet and enclosed installation
Fieldbus distribution interface, Segment Protector with trunk short circuit
R2-SP-N10
protection, 4 channels, for cabinet and enclosed installation
Fieldbus distribution interface, Segment Protector with trunk short circuit
R2-SP-N12
protection, 4 channels, for cabinet and enclosed installation
Fieldbus distribution interface, Modular Segment Protector with trunk short
RM-SPTM-N2
circuit protection, Trunk module, 2 output channels
Fieldbus distribution interface, Modular Segment Protector with trunk short
RM-SPEM-N4
circuit protection, Extension module, 4 output channels

Field Barrier

FieldBarrier, Fieldbus distribution interface 4 intrinsically


RD0-FB-Ex4
safe outputs in acc.to FISCO, fixed connectors
FieldBarrier, Fieldbus distribution interface 4 intrinsically
RD0-FB-Ex4.COM
safe outputs in acc.to FISCO, pluggable connectors
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

REMOTE I/O

Stations/Backplane Zone 2 or safe area

LB 9022 LB-Backplane, redundant for 12 single or 6 double modules, 3 power supplies


LB 9023 LB-Backplane, base unit for 8 single or 4 double modules, 1 power supply
LB 9024 LB-Backplane, extension unit for 22 single or 11 double modules, 3 power supplies
LB 9025 LB-Backplane, extension unit for 8 single or 4 double modules, 1 power supply
LB 9026 LB-Backplane, base unit for 16 single or 8 double modules, 2 power supplies
LB 9027 LB-Backplane, extension unit for 16 single or 8 double modules, 2 power supplies
LB 9029 LB-Backplane, redundant for 12 single or 6 double modules, 3 power supplies
LB 9035 LB-Backplane, Foundation Fieldbus for 5 double modules, 1 power supply

Power Supply Zone 2 or safe area

LB 9006 Power supply, 24 V DC

Communications Unit Zone 2 or safe area

LB 8105 PROFIBUS ComUnit (Standard)


LB 8106 EasyCom ComUnit (PROFIBUS)
LB 8107 MODBUS ComUnit
LB 8108 PROFIBUS ComUnit (Timestamp)
LB 8109 PROFIBUS ComUnit (UniCom)
LB 8110 FF ComUnit

Digital Input Zone 2 or safe area

LB 1x01 Digital input, 2 isolated channels


LB 1x02 Digital input, 3 channels
LB 1x03 Digital input, 1 channel, frequency, counter
LB 1007 Digital input, 7 channels
LB 1x08 Digital input, 8 channels
LB 1014 Digital input, 15 channels, 230 V
LB 1015 Digital input, 15 channels, 24 V
model code x = 0 Non IS, X =1 IS (intrinsically safe)
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Digital output with feedback Zone 2 or safe area

LB 2101 Digital out with feedback, 22 V, 315 Ohm


LB 2102 Digital out with feedback, 24 V, 210 Ohm
LB 2103 Digital out with feedback, 24 V, 360 Ohm
LB 2104 Digital out with feedback, 22 V, 220 Ohm
LB 2105 Digital out with feedback, 22.8 V, 290 Ohm
LB 2112 Digital out with feedback, 25.3 V, 329 Ohm
LB 2113 Digital out with feedback, 26.7 V, 509 Ohm

Digital output (Relay) Zone 2 or safe area

LB 6101 Relay output, 2 channels, 230 V


LB 6005 Relay output, 4 channels, 230 V
LB 6006 Relay output, 8 channels, 24 V
non IS

Digital output, active Zone 2 or safe area

LB 6108 Digital output, 8 channels, 20 V, 8 mA low power

Digital output, active Zone 2 or safe area

LB 6110 Digital out, 4 channels, 24.5 V, 370 Ohms


LB 6111 Digital out, 4 channels, 24.5 V, 320 Ohms
LB 6112 Digital out, 4 channels, 17 V, 185 Ohms
LB 6113 Digital out, 4 channels, 23 V, 290 Ohms
LB 6114 Digital out, 4 channels, 23 V, 355 Ohms
LB 6115 Digital out, 4 channels, 16.2 V, 78 Ohms

Analog input (current) Zone 2 or safe area

LB 3102 Analog input, 1 channel, HART


LB 3105 Analog input, 4 channels, HART
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Analog input (Temperature, voltage) Zone 2 or safe area

LB 5101 Analog input, RTD


LB 5102 Analog input, thermocouples, mV
LB 5104 Analog input, RTD, 4 channels
LB 5105 Analog input, thermocouples, mV, 4 channels
LB 5106 Analog input, 10 V

Analog output (current) Zone 2 or safe area

LB 4102 Analog output, HART


LB 4105 Analog output, HART, 4 channels

Stations / Backplane Zone 1

FB 9224 FB base unit, 24 I/O slots


FB 9225 FB redundancy unit
FB 9226 FB station, 10 I/O slots
FB 9248 FB base and extension unit, 48 I/O slots
FB 9249 FB redundant station, 48 I/O slots
FB 9251 FB Foundation Fieldbus Modular I/O, 5 dual slots

Power Supplies Zone 1

FB 9206 Power supply 24 V DC


FB 9215 Power supply 230 V AC
FB 9216 Power supply 115 V AC

Bus termination modules Zone 1

FB 9293 Bus termination module for servicebus


FB 9294 Bus termination module for fieldbus
FB 9295 Bus termination module for field- and service bus
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Communication units Zone 1

FB 8205 PROFIBUS ComUnit (Standard)


FB 8206 EasyCOM ComUnit (PROFIBUS)
FB 8207 MODBUS ComUnit
FB 8209 PROFIBUS ComUnit (UniCom)
FB 8210 FF ComUnit

Digital input Zone 1

FB 1201 Digital input, 2 isolated channels


FB 1202 Digital input, 3 channels
FB 1203 Digital input, 1 channel, frequency, counter
FB 1208 Digital input, 8 channels

Digital output with feedback Zone 1

FB 2201 Digital out with feedback, 22 V, 315 Ohm


FB 2202 Digital out with feedback, 24 V, 210 Ohm
FB 2203 Digital out with feedback, 24 V, 360 Ohm
FB 2204 Digital out with feedback, 22 V, 220 Ohm
FB 2205 Digital out with feedback, 22.8 V, 290 Ohm
FB 2212 Digital out with feedback, 25.3 V, 329 Ohm
FB 2213 Digital out with feedback, 26.7 V, 509 Ohm

Digital output, relay Zone 1

FB 6301 Relay output, 2 channels, 230 V


FB 6305 Relay output, 4 channels, 230 V
FB 6306 Relay output, 8 channels, 24 V
increased safety

Digital output Zone 1

FB 6208 Digital output, 8 channels, 20 V, 8mA low power


MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Digital output, active Zone 1

FB 6210 Digital out, 4 channels, 24.5 V, 370 Ohms


FB 6211 Digital out, 4 channels, 24.5 V, 320 Ohms
FB 6212 Digital out, 4 channels, 17 V, 185 Ohms
FB 6213 Digital out, 4 channels, 23 V, 290 Ohms
FB 6214 Digital out, 4 channels, 23 V, 355 Ohms
FB 6215 Digital out, 4 channels, 16.2 V, 78 Ohms

Analog input (current) Zone 1

FB 3202 Analog input, 1 channel, HART


FB 3205 Analog input, 4 channels, HART

Analog input (Temperature, voltage) Zone 1

FB 5201 Analog input, RTD


FB 5202 Analog input, thermocouples, mV
FB 5204 Analog input, RTD, 4 channels
FB 5205 Analog input, thermocouples, mV, 4 channels
FB 5206 Analog input, 10V

Analog output (current) Zone 1

FB 4202 Analog output, HART


FB 4205 Analog output, HART, 4 channels
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

K-SYSTEM
Isolated Barriers

Switch Amplifiers (24 DC Suply voltage)

KFD2-SR2-Ex1.W 1-channel; 1 relay output with 1 changeover contact


KFD2-SR2-Ex1.W.LB 1-channel; signal output (changeover contact) and optionally signal output/fault signal
KFD2-SR2-Ex2.W 2-channel; 1 signal output with 1 changeover contact per channel
KFD2-SR2-Ex2.W.SM 1-channel; additional input for rotatio ndirection or start-up override; 2 relay outputs
KFD2-SR2-Ex2.2S 2-channel; 1 relay output per channel with 2 NO contacts each
1-channel; signal output and either signal output or error message;
KFD2-SOT2-Ex1.LB.IO
outputs galvanically isolated
KFD2-SOT2-Ex2.LB.IO 2-channel; 1 passive transistor output, depolarized per channel

Switch Amplifiers (115 / 230 V AC Supply Voltage)

KFA5-SR2-Ex1.W 1-channel; 1 relay output with 1 changeover contact


KFA6-SR2-Ex1.W 1-channel; 1 relay output with 1 changeover contact
KFA5-SR2-Ex1.W.LB 1-channel; signal output (changeover contact) and optionally signal output/fault signal
KFA6-SR2-Ex1.W.LB 1-channel; signal output (changeover contact) and optionally signal output/fault signal
KFA5-SR2-Ex2.W 2-channel; 1 relay output with 1 changeover contact per channel
KFA6-SR2-Ex2.W 2-channel; 1 relay output with 1 changeover contact per channel
KFA5-SR2-Ex2.W.IR 2-channel; 1 signal output with 2 changeover contacts
KFA6-SR2-Ex2.W.IR 2-channel; 1 signal output with 2 changeover contacts

Solenoid Driver

KFD0-SD2-Ex1.1045 1-channel; current limit 45 mA


KFD0-SD2-Ex2.1045 2-channel; current limit 45 mA
KFD0-SD2-EX1.1065 1-channel; current limit 65 mA
KFD0-SD2-EX1.1180 1-channel; current limit 80 mA
KFD0-SD2-Ex2.1245 2-channel; current limit 45 mA
KFD0-SD2-EX1.10100 1-channel; current limit 45 mA

Transmitter Power Supply (24 V DC Supply Voltage)

KFD2-STC4-Ex1 1-channel; HART capable; 1 output 4 … 20 mA source


KFD2-STC4-Ex1.2O 1-channel; HART capable; 2 outputs 4 … 20 mA source
KFD2-STC4-Ex2 2-channel; HART capable; 2 outputs 4 … 20 mA source
KFD2-STV4-Ex1-2 1-channel; HART capable; 1 output 1 … 5 V source
KFD2-STV4-Ex1-1 1-channel; HART capable; 1 output 2 … 10 V source
KFD2-STV4-Ex1.2O-1 1-channel; HART capable; 2 outputs 1 … 5 V source
KFD2-STV4-Ex1.2O-2 1-channel; HART capable; 1 outputs 2 … 10 V source
KFD2-STV4-Ex2-1 2-channel; HART capable; 2 outputs 1 … 5 V source
KFD2-STV4-Ex2-2 2-channel; HART capable; 2 outputs 2 … 10 V source
KFD2-CR4-Ex1 1-channel; 1 output 4 … 20 mA source
KFD2-CR4-Ex1.2O 1-channel; 2 outputs 4 … 20 mA source
KFD2-CR4-Ex2 2-channel; 2 outputs 4 … 20 mA source
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Universal Signal Converters

KFU8-UFC-Ex1.D 1-channel; analog output 0/4 mA ... 20 mA


KFU8-UFT-Ex2.D 2-channel; analog output 0/4 mA ... 20 mA
KFU8-GUT-Ex1.D 1-channel; analog output 0/4 mA ... 20 mA
KFU8-CRG2-Ex1.D 1-channel; analog output 0/4 mA ... 20 mA

Temperature Converter (24 V DC Supply Voltage)

KFD2-UT2-Ex1 1-channel; analog current output 0/4 mA ... 20 mA


KFD2-UT2-Ex1-1 1-channel; voltage output 0/1 ... 5 V
KFD2-UT2-Ex2 2-channel; 2 analog current outputs 0/4 mA ... 20 mA
KFD2-UT2-Ex2-1 2-channel; 2 voltage outputs 0/1 ... 5 V

Smart Current Driver (24 V DC Supply Voltage)

KFD2-SCD2-Ex1.LK 1-channel; HART capable; 4 … 20 mA current output


KFD2-SCD2-Ex2.LK 2-channel; HART capable; 4 … 20 mA current output

K-SYSTEM
Signal Conditioner

Transmitter Power Supply (24 V DC Supply Voltage)

KFD2-STC4-1 1-channel; HART capable; 1 output 4 ... 20 mA source


KFD2-STC4-1.2O 1-channel; HART capable; 2 outputs 4 ... 20 mA source
KFD2-STC4-2 2-channel; HART capable; 2 outputs 4 ... 20 mA source
KFD2-STV4-1-1 1-channel; HART capable; 1 output 1... 5 V source
KFD2-STV4-2-1 2-channel; HART capable; 2 outputs 2 ... 10 V source
KFD2-CR4-2 2-channel; HART capable; 2 outputs 4 ... 20 mA source
KFD2-CR4-1.2O 1-channel; HART capable; 2 outputs 4 ... 20 mA source

Temperature Converter (24 V DC Supply Voltage)

KFD2-UT2-1 1-channel; analog current output 0/4 mA ... 20 mA


KFD2-UT2-1-1 1-channel; voltage output 0/1... 5 V
KFD2-UT2-2 2-channel; 2 analog current outputs 0/4 mA ... 20 mA
KFD2-UT2-2-1 2-channel; 2 voltage outputs 0/1... 5 V
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Smart Current Driver (24 V DC Supply Voltage)

KFD2-SCD2-1.LK 1-channel; HART capable; 4 ... 20 mA current output


KFD2-SCD2-2.LK 2-channel; HART capable; 4 ... 20 mA current output

K-System Accessories

UPR-03 Universal power rail


KFD2-EB2 Power feed moduel, fault signal relay output
KFD2-EB2.R4A.B Power feed module with bus terminal, fault signal relay output NO

Z-SYSTEM
Zener Barriers

Z*** All Zener barriers of the Z-System


Positive Polarity Shunt Zener Diode Barriers: Z7**
Positive Polarity Shunt Zener Diode Barriers: Z8**
A.C. Shunt Zener Diode Barriers: Z9**
MARINE CERTIFIED PRODUCTS BY PEPPERL+FUCHS

Standard inductive sensors

Cylindrical sensors M8x1

NBB2-8GM30-E0 Operating distance 2 mm, housing M8x1, NPN NO output, flush mountable, 2 m cable
NBB2-8GM30-E0-V1 Operating distance 2 mm, housing M8x1, NPN NO output, flush mountable, connector M12
NBB2-8GM30-E2 Operating distance 2 mm, housing M8x1, PNP NO output, flush mountable, 2 m cable
NBB2-8GM30-E2-V1 Operating distance 2 mm, housing M8x1, PNP NO output, flush mountable, connector M12
NBN3-8GM30-E0 Operating distance 3 mm, housing M8x1, NPN NO output, non-flush mountable, 2 m cable
NBN3-8GM30-E0-V1 Operating distance 3 mm, housing M8x1, NPN NO output, non-flush mountable, connector M12
NBN3-8GM30-E2 Operating distance 3 mm, housing M8x1, PNP NO output, non-flush mountable, 2 m cable

NBN3-8GM30-E2-V1 Operating distance 3mm, housing M8x1, PNP NO output, non-flush mountable, connector M12

Cylindrical sensors M12x1

NBB4-12GM50-E0 Operating distance 4 mm, housing M12x1, NPN NO output, flush mountable, 2 m cable
NBB4-12GM50-E0-V1 Operating distance 4 mm, housing M12x1, NPN NO output, flush mountable, connector M12
NBB4-12GM50-E2 Operating distance 4 mm, housing M12x1, PNP NO output, flush mountable, 2 m cable
NBB4-12GM50-E2-V1 Operating distance 4 mm, housing M12x1, PNP NO output, flush mountable, connector M12
NBN8-12GM50-E0 Operating distance 8 mm, housing M12x1, NPN NO output, non-flush mountable, 2 m cable
NBN8-12GM50-E0-V1 Operating distance 8 mm, housing M12x1, NPN NO output, non-flush mountable, connector M12
NBN8-12GM50-E2 Operating distance 8 mm, housing M12x1, PNP NO output, non-flush mountable, 2 m cable
NBN8-12GM50-E2-V1 Operating distance 8mm, housing M12x1, PNP NO output, non-flush mountable,connector M12

Cylindrical sensors M18x1

NBB8-18GM50-E0 Operating distance 8 mm, housing M18x1, NPN NO output, flush mountable, 2 m cable
NBB8-18GM50-E0-V1 Operating distance 8 mm, housing M18x1, NPN NO output, flush mountable, connector M12
NBB8-18GM50-E2 Operating distance 8 mm, housing M18x1, PNP NO output, flush mountable, 2 m cable
NBB8-18GM50-E2-V1 Operating distance 8 mm, housing M18x1, PNP NO output, flush mountable, connector M12
NBN12-18GM50-E0 Operating distance 12 mm, housing M18x1, NPN NO output, non-flush mountable, 2 m cable
NBN12-18GM50-E0-V1 Operating distance 12 mm, housing M18x1, NPN NO output, non-flush mountable, connector M12
NBN12-18GM50-E2 Operating distance 12 mm, housing M18x1, PNP NO output, non-flush mountable, 2 m cable
NBN12-18GM50-E2-V1 Operating distance 12 mm, housing M18x1, PNP NO output, non-flush mountable, connector M12

Cylindrical sensors M30x1,5

NBB15-30GM50-E0 Operating distance 15 mm, housing M30x1, NPN NO output, flush mountable, 2 m cable
NBB15-30GM50-E0-V1 Operating distance 15 mm, housing M30x1, NPN NO output, flush mountable, connector M12
NBB15-30GM50-E2 Operating distance 15 mm, housing M30x1, PNP NO output, flush mountable, 2 m cable
NBB15-30GM50-E2-V1 Operating distance 15 mm, housing M30x1, PNP NO output, flush mountable, connector M12
NBN25-30GM50-E0 Operating distance 25 mm, housing M30x1, NPN NO output, non-flush mountable, 2 m cable
NBN25-30GM50-E0-V1 Operating distance 25mm, housing M30x1, NPN NO output, non-flush mountable, connector M12
NBN25-30GM50-E2 Operating distance 25 mm, housing M30x1, PNP NO output, non-flush mountable, 2 m cable
NBN25-30GM50-E2-V1 Operating distance 25mm, housing M30x1, PNP NO output, non-flush mountable, connector M12

*Please ask for further product information or visit www.pepperl-fuchs.com