0% found this document useful (0 votes)
295 views

(Beam To Beam) : # of Bars Continuous # of Non-Continuous Bars Size of Bars

The document provides specifications for reinforcing a beam with a length of 460 cm and other dimensions. It calculates that 231 pieces of continuous reinforcing bar and 462 pieces of bar total are needed for the top and bottom bars. It also states that 416 pieces of 8 mm stirrup bars are required, along with 78.5 kg of tie wire.

Uploaded by

mohammednasru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
295 views

(Beam To Beam) : # of Bars Continuous # of Non-Continuous Bars Size of Bars

The document provides specifications for reinforcing a beam with a length of 460 cm and other dimensions. It calculates that 231 pieces of continuous reinforcing bar and 462 pieces of bar total are needed for the top and bottom bars. It also states that 416 pieces of 8 mm stirrup bars are required, along with 78.5 kg of tie wire.

Uploaded by

mohammednasru
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

BEAM REINFORCEMENT (BEAM TO BEAM = LESS THAN 6.

0 METERS) ONE BAY

Enter Beam to Beam Length L (M) 460.00 M


Enter Beam Width W (M) 0.40 M
L(beam to beam) Enter Beam Depth D (M) 0.20 M
Enter Column Width Cw(M) 0.20 M
# of Non-
# of Bars
Top Bars Continuous Size of Bars Units
Continuous
Bars
D Top Bars 3 - 10.00 mm
Web Bars
Web Bars - - 10.00 mm
Note: put "0" zero if web bars not applicable
Bottom Bars
Bottom Bars 3 - 10.00 mm
W
Enter Stirrup Bars Diameter required: 8.00 mm
Enter Stirrup Spacing: 0.20 M

L = Span
L/4

0.15L

Column
Width
TOP BARS
# of 6m Length Deformed Bars required as Continuous Bars 231.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS
WEB BARS
# of 6m Length Deformed Bars required as Web Bars - PCS
BOTTOM BARS
# of 6m Length Deformed Bars required as Continuous Bars 231.00 PCS
# of 6m Length Deformed Bars required as Non-Continuous Bars - PCS

BY: ENGR. RONALD JOHN R. CAJILLA


Number of 10mm bars used as main bars 462.00 PCS
Number of 10mm bars used as web bars - PCS
Number of 8mm bars used as stirrups 416.00 PCS
#16 TIE WIRE USED: 78.50 Kgs

BASED ON MAX FAJARDO - SIMPLIFIED CONSTRUCTION ESTIMATE HANDBOOK

You might also like