The document describes a micro-ohmmeter device used to measure contact resistances in high-voltage equipment. It can output up to 600A DC and has features making it rugged and easy to use for field work. Application examples and specifications are provided.

Uploaded by

Rene Alog
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
100 views

MOM600A

The document describes a micro-ohmmeter device used to measure contact resistances in high-voltage equipment. It can output up to 600A DC and has features making it rugged and easy to use for field work. Application examples and specifications are provided.

Uploaded by

Rene Alog
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

MOM600A

Micro-ohmmeter

MOM600A
Micro-ohmmeter

▪▪Compact and rugged

▪▪Easy-to-use

▪▪600 A output current

DESCRIPTION APPLICATION EXAMPLES


Switchgear breakdowns are frequently caused by excessively high A. Measuring the resistance of a circuit
contact resistance at breakpoints and busbar joints. Moreover,
breaker element
overheating risks are becoming more serious due to the fact that
today's distribution networks have to carry heavier loads. Checking 1. Connect the micro-ohmmeter to the circuit breaker.
contact resistances at regular intervals detects faults before they 2. Set the current (100 A in this example).
cause overheating. And here, an ounce of prevention is worth a 3. Press the resistance pushbutton.
pound of cure.
4. Read the result.
Micro-ohmmeters are used to measure contact resistances in high-
voltage breakers, disconnecting switches (isolators), knife-contact B. Measuring the resistance of busbar joints
fuses, bus joints, line joints etc. 1. Connect the micro-ohmmeter’s current cables to the object be-
The MOM600A™ is in a class apart on world markets. Designed for ing tested. Do not connect the sensing cables since measure-
use from the arctic to the tropics, this rugged, compact micro-ohm- ments will be taken using an external movable voltmeter.
meter is ideal for field work. 2. Set the current (100 A in this example).
A complete set of equipment includes a set of highly flexible cables 3. Connect an external voltmeter to the bus.
(including separate measurement cables) and a sturdy transport 4. Read the voltmeter (0.1 mV = 1 µΩ in this example).
case.
5. Move the voltmeter to the next joint.
6. Repeat step 4.

A B
MOM600A
Micro-ohmmeter

SPECIFICATIONS Load capacity, 230 V model


Specifications are valid at nominal input voltage and an ambient Current adjustment set to 100%
temperature of +25°C, (77°F). Specifications are subject to change Output Min. output Max. Rest time Input current
without notice. current voltage load time
Environment 100 A DC 8.3 V – – 6A
Application field The instrument is intended for use in 300 A DC 7.2 V 2.5 min. 15 min. 16 A
high-voltage substations and industrial
600 A DC 5.6 V 15 s 5 min. 32 A
environments.
Temperature
Operating 115 V 0°C to +50°C (32°F to +122°F)
Operating 230 V 0°C to +40°C (32°F to +104°F)
Storage & transport -40°C to +70°C (-40°F to +158°F)
Humidity 5% – 95% RH, non-condensing
CE-marking
EMC 2004/108/EC
LVD 2006/95/EC
General
Mains voltage 115 / 230 V AC, 50 / 60 Hz
Power consumption (max) 115 V, 4370 VA
230 V, 7360 VA
Protection Miniature circuit breakers, thermal
cut-outs
Dimensions
Instrument 356 x 203 x 241 mm (14” x 8” x 9,5”)
Transport case 610 x 290 x 360 mm
(24.0” x 11.4” x 14.2”) Cable set GA-05053 (2 current cables and 2 sensing cables)
Weight, 115 V model 25 kg (55.1 lbs) 43.1 kg (95 lbs) with
accessories and transport case
Weight, 230 V model 24.7 kg (54.5 lbs), 42.8 kg (94.4 lbs)
with accessories and transport case
Current cables 2 x 5 m (16 ft), 50 mm²
Sensing cables 2 x 5 m (16 ft), 2.5 mm²
Measurement section
Resistance range 0 – 1999 μΩ
Resolution 1 μΩ
Inaccuracy ±1% of reading + 1 digit Ground cable GA-00200 Optional accessory:
(at 100 – 600 A test current) Calibration shunt BB-90020
Output, 115 V model ORDERING INFORMATION
Current 0 – 600 A DC Item Art. No.
Open circuit voltage 5.2 V DC MOM600A
Current shunt output 10 mV / 100 A ±0.5%, max 60 mV out, Complete with: Cable set GA-05053, Ground cable
max 10 V to protective earth (ground) GA-00200, Transport case GD-00182
Output, 230 V model 115 V Mains voltage BB-11190
Current 0 – 600 A DC 230 V Mains voltage BB-12290
Open circuit voltage 9 V DC
Optional accessories
Current shunt output 10 mV / 100 A ±0.5%, max 60 mV out,
Cable set 10 m
max 10 V to protective earth (ground)
2 x 10 m (33 ft), 70 mm2 (current cables).
Load capacity, 115 V model 2 x 10 m (33 ft), 2.5 mm2 (sensing cables)
Current adjustment set to 100% Weight: 16.8 kg (37 lbs) GA-07103
Output Min. output Max. Rest time Input current Cable set 15 m
current voltage load time 2 x 15 m (49 ft), 95 mm2 (current cables).
100 A DC 4.6 V - - 8A 2 x 15 m (49 ft), 2.5 mm2 (sensing cables)
Weight: 29.4 kg (65 lbs) GA-09153
300 A DC 3.8 V 1.5 min. 15 min. 20 A
Calibration shunt
600 A DC 2.6 V 10 s 5 min. 38 A
600 A/60 mV BB-90020

SALES OFFICE MOM600A_DS_en_V04a


Megger Sweden AB Art. No. ZI-BB05E ▪ BB0375EE ▪ 2017
Rinkebyvägen 19 Subject to change without notice.
SE-182 36 DANDERYD
SWEDEN ISO 9001:2008
+46 8 510 195 00 The word ”Megger” is registered trademark
[email protected] www.megger.com