Sample Column Retrofitting
Sample Column Retrofitting
PROJECT: WEIP2/PK-F2
ELEMENT: Pile-500
INDEX
5.- RESULTS..................................................................................................................................................................... 6
5.1.- Summary of results........................................................................................................................................ 6
5.2.- Ultimate limit states...................................................................................................................................... 7
5.3.- Serviceability limit states............................................................................................................................... 10
5.4.- Fire resistance (t=0 min.)............................................................................................................................... 12
5.5.- FRP arrangement........................................................................................................................................... 13
- ACI 440.2R-17
- ACI 318
- Country: Singapore
2.1.- Geometry
Cross section = Circular
Diameter (d) = 500 mm
500
2.2.- Concrete
Compressive strength of concrete
Concrete strength (f'c) = 50 MPa
Cylinder specimen = 50 MPa
Cube specimen = 60 MPa
Ef Thickness tf Width
Laminate efu
*
Number n
(MPa) (mm) (mm)
SikaWrap® 301C - 50cm 0.0156 225000.00 0.167 4 500.00
σ (MPa)
70 Confined concrete
Un-confined concrete
(6.8, 63.7)
60
(2.1, 54.2)
50 (2.0, 50.0)
(3.0, 50.0)
40
30
20
10
0 1 2 3 4 5 6 7
ε (‰)
Un-confined concrete*
e 2
f ' 1- 1- c ec :
'
0 ec e'c 0.0020
fc c e'c
f 'c e'c ec ecu
ecu : 0.0030
The stress-strain model adopted for FRP-confined concrete is computed using the following
expressions (ACI 440.2R-17, 12.1)*
Ec E2 2
2
f 'cc f 'c
E2 E2 : 2031.23 MPa
eccu
2 f 'c
e 't
et :
'
Ec E2 0.0021
*The strength of the unconfined member, and the strength of the confined member for the
design stress-strain model, are respectively 0.85·f'c and 0.85·f'cc.
Maximum compressive strength for the confined concrete
f 'cc f 'c F 3,3 a fl f'cc : 63.75 MPa
A strain efficiency factor e of 0.55 and a minimum confinement ratio fl/f'c of 0.08 must be used
* ffu* ffu Ef Ec tf D
efu CE efu e
'
ec n A A a b f
(MPa) (MPa) (MPa) (MPa) (mm) (mm) e c
0.0156 3510.00 0.85 0.0133 2983.50 225000.00 0.55 0.0020 50000.00 4 0.167 500.00 0.00 1.00 1.00 0.95
Mx
My
x
The live load acting on the member is expected to be present for a sustained period of time
5.- RESULTS
6000
5000 Su(162.8,4950)
4000
3000
2000
1000
-1000
-2000
-3000
ε = 2.0 ‰
x
ε = 0.0 ‰
εmin
εmax σmax
ε = 6.8 ‰
x
ε = 2.1 ‰
ε = 0.0 ‰
εmin
εmin
9000
8000
7000
6000
5000
Su(148,4500)
4000
3000
2000
1000
0
-1000
-2000
-3000
εmax σmax
ε = 3.0 ‰
ε = 2.0 ‰
x
ε = 0.0 ‰
εmin
The nominal strength of the un-strengthened member exceeds the combination of loads corresponding to the fire
situation. The FRP strengthening is therefore not necessary during a fire situation, and does not need to be protected. If
a certain fire rating is necessary, the designer must evaluate the need for a protection of the RC element (concrete and
steel reinforcement) according to the local codes.
5.5.- FRP arrangement
The previous results correspond to the following FRP scheme:
4 layers of SikaWrap® 301C - 50cm
The material shall have a long track record (> 25 years) for structural strengthening.
The fibre fabric shall be unidirectional and fabricated of PAN based carbon fibres.
Measured values of mechanical properties of laminated fabrics shall be provided, minimum test series of 20 samples.
The actual strength of the concrete substrate shall be verified with at least three pull-off tests.
The laitance layer on the substrate surface shall be removed and an open-textured surface shall be created.
The substrate surface shall be cleaned so that it is free from oil, grease and any other contaminants as well as loose
particles and dust.
For fibre fabric application, all corners shall be rounded to a minimum radius of 20 mm and any sharp edges shall be
removed.
The priming of the substrate and the saturation of the SikaWrap® 301C - 50cm fabric will be done by means of
Sikadur®-330
In case of column confinement, the minimum overlap of the fabric in fibre direction shall be 150 mm
A primer layer of the impregnating resin shall be applied on the substrate surface, using a toothed trowel or a roller.
The fabric shall be placed on the substrate, pressed on gently, and the resin shall be worked into the fabric with an
impregnation roller until the fabric is completely saturated.
In case of a cementitious overcoat, the resulting resin surface shall be broadcasted with quartz sand.
After application, the finished fibre fabric installation of shall be protected from rain, sand, dust and any other
contaminants.
With respect to the software application and results derived from its use, SIKA MAKES NO WARRANTIES OF ACCURACY,
RELIABILITY, COMPLETENESS, MERCHANTABILITY OR FITNESS FOR ANY PURPOSE. THE SOFTWARE APPLICATION IS
PROVIDED ON AN "AS-IS" BASIS AND SIKA EXPRESSLY DISCLAIMS ANY WARRANTIES WITH RESPECT TO THE SOFTWARE
APPLICATION AND RESULTS DERIVED FROM ITS USE.
Sika shall not be liable for any consequential, punitive, incidental, exemplary, or special damages (including but not
limited to loss of business opportunity or loss of profit) arising out of the evaluation or use of the software application
and results derived from its use.
The information, and, in particular, the recommendations relating to the application and end-use of Sika products, are
given in good faith based on Sika's current knowledge and experience of the products when properly stored, handled
and applied under normal conditions in accordance with Sika’s recommendations. In practice, the differences in
materials, substrates and actual site conditions are such that no warranty in respect of merchantability or of fitness for a
particular purpose, nor any liability arising out of any legal relationship whatsoever, can be inferred either from this
information, or from any written recommendations, or from any other advice offered. The user of the product must test
the product’s suitability for the intended application and purpose. Sika reserves the right to change the properties of its
products. The proprietary rights of third parties must be observed. All orders are accepted subject to our current terms
of sale and delivery. Users must always refer to the most recent issue of the local Product Data Sheet for the product
concerned, copies of which will be supplied on request.
Except as indicated otherwise, all information, text, graphic images, features, functions, and layout contained in this
software are the exclusive property of Sika and may not be copied or distributed, in whole or in part, without the
Company's express written consent.
By transmitting information to Sika, you grant to the Company the unrestricted irrevocable license to use, reproduce,
display, modify, distribute and perform such information. Personal identity information is used by Sika only to process a
request for information by you or for marketing our products and services.
Engineered by: