The document provides details on the structural design of a 3-story frame structure building. It includes information on the building materials, loads, analysis method, and design specifications. The structure will be made of reinforced concrete and structural steel. Seismic analysis was performed using the response spectrum method with a zone factor of 1. The slab and beam designs met code requirements for span-to-depth ratios. Reinforcement and load combinations were provided based on limit state design philosophy.
Download as XLSX, PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
60 views
Structural Design (Type B) : General
The document provides details on the structural design of a 3-story frame structure building. It includes information on the building materials, loads, analysis method, and design specifications. The structure will be made of reinforced concrete and structural steel. Seismic analysis was performed using the response spectrum method with a zone factor of 1. The slab and beam designs met code requirements for span-to-depth ratios. Reinforcement and load combinations were provided based on limit state design philosophy.
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4
STRUCTURAL DESIGN (TYPE B)
Building Elements As Per Submitted Design Remarks
General Building Structure Type Frame Structure No. of Storeys applied for permit (in Nos.) three storey Number of storeys considered in structural design (in Nos.) three storey If Computer Aided Design (CAD) is used, please state the name of the software package Etabs 2016 Number of storeys considered in the design Yes provision for further extension (in Nos.) No Total height (h) of structure with extension (in 8.53 m) NBC 101-1994 MATERIALS SPECIFICATIONS structural Aluminium Brick Masonry Materials to be used in structure (tick the Timber listed materials that will be used in structure element) Structural Steel RCC ( Reinforcement Bar) Stone Masonry NBC 101-1994 Unit Weight of Materials Specify the design unit weight of materials : Steel (in kg/m3) 7850 Specify the design unit weight of materials : RCC (in kg/m3) 2500 Specify the design unit eight of materials : Brick Masonry (in kg/m3) 1900 NBC 101-1994 Unit Weight of Materials For Residential Buildings Occupancy Load (Uniformly Distibuted load in KN/m2) for Bed rooms, ward, dressing rooms. 2 Occupancy Load (Uniformly Distibuted load in KN/m2) for Kitchen. 2 Occupancy Load (Uniformly Distibuted load in KN/m2) for X-ray rooms, operation rooms. Occupancy Load (Uniformly Distibuted load in KN/m2) for Corridors, Passage and Staircase. 3 Occupancy Load (Uniformly Distibuted load in KN/m2) for Balconies. 3 NBC 101-1994 Unit Weight of Materials Wind Zone 2 Basic wind speed (in m/s) 47 NBC 101-1994 Seismic Design of Buildings in Nepal Seismic Coefficient Approach Method adopted for earthquake resistant desig Response Spectrum Method Method adopted for earthquake resistant desig Others Adopted Code for Seismic Design IS 1893 Type I (Hard) Subsoil Category Type II (Medium) Type III (Soft) Seismic Weight (W) (in KN) 2615.17 Fundamental Time period of the building along X (Tx) (in seconds) 0.374 Fundamental Time period of the building along Y (Ty) (in seconds) 0.374 Basic Seismic Coefficient Along X ( C ) 0.08 Basic Seismic Coefficient Along Y( C ) 0.08 Seismic zoning factor (Z) 1 Imortance Factor (I) 1 Structural Performance Design Horizontal factorCoefficient Seismic (K) (if NBC used) Along 1 X(Cd) Design Horizontal Seismic Coefficient Along 0.08 Y(Cd) 0.08 Base Shear (Vb) for Seismic Coefficient Along X 235.37 Base Shear (Vb) for Seismic Coefficient Along Y 235.37 Base Shear Generated through dynamic Analysis Along X ( if response spectrum method used) Base Shear Generated through dynamic Analysis Along Y ( if response spectrum method used) Adopted Base Shear multiplication Factor Along X (if response spectrum method used) Adopted Base Shear multiplication Factor Along Y (if response spectrum method used) Base Shear after Scale Factor Along X 235.37 Base Shear after Scale Factor Along Y 235.37 Maximum Inter Sorey Drift 0.002 Corresponding Storey height for Maximum Inter-Strey Drift (h) 2.845 NBC 106-1994 Snow Load Perennial Snowfall type or condition Occasional No snowfall Elevation of construction site (in m) Design Depth of snow (in cm) Design Density of sno (in g/cm3) NBC 107-1994 Provisional Recommendation on Fire Safety Yes Have you considered fire safety requirement? No NBC 108-1994 Site Consideration for Seismic Hazards Whether Distance of construction site from Yes toe/beginning of downward slope is within 50m? No Whether Distance of construction site from Yes river bank is within 50m? No Yes Availability of soil test report Availability of soil test report No NBC 114-1994 Construction Safety Are you sure that all safety measures will be Yes fulfilled in the construction site as per this code? No
safety hard hat
Materials to be used in structure (tick the safety goggles listed materials that will be used in structure element) safety boots safety belts first aid facility Structural Data for Framed RCC Structure NBC 110-1994 Plain and Reinforced Concrete Concrete grade in structure M20 M25 M30 M35 Reinforcement Steel Grade Fe-415 Fe-500 Fe-550 Slab design 4 side continous 1 short side discontinous 1 long side discontinous 2 adjacent side continous boundary condition of slab 2 long side continous design gareko slab ko 2 short side continous 1 short side continous 4 side discontinous Effective Thickness of slab (d) (in mm) 105.00 Short span of Critical slab panel (L) (in mm) 4160.00 design gareko slab ko Calculated short span to effective depth ratio 39.6190476190476 (L/d) Basic for theratio (L/d) corresponding slab 23.00 Required modification factor for tension 1.673 reinforcement Required Tension reinforcement(Ast) 0.207 Percentage (%) for short span bottom reinforcement Provided Tension reinforcement(Ast) 0.67 Percentage (%) for short span bottom reinforcement Actual Modification factor for tension 2 reinforcement slab Check for Critical beam Effective depth of beam (d) (in mm) 380 Critical span (L) (in mm) 3760 Cantilever Simply supported Support condition One side continous Both side continous Basic (L/d) ratio 23 Calculated critical span to effective depth ratio 9.89473684210526 (L/d) for corresponding slab Check for Critical Column Critical Column height 2.4 Minimum size of column (mm x mm) 406x508 Yes Short column effect considered or not No Minimum area of longitudinal reinforcement 1.35 provided(%)
foundations, columns, beams and slabs are submitted No Isolated Combined Type of Foundations Raft PILE Strap Depth of foundation from ground level to the bottom of footing (in mm) 1892