Ventilation systems have been used for hundreds of years to provide fresh air in buildings. Modern guidelines recommend supplying 15-25 cubic feet per minute of outside air per person for non-smoking areas and 50 cubic feet per minute for smoking areas. Central HVAC systems typically supply a mix of 20% outside air and 80% return air to ventilate and pressurize conditioned spaces. The outside air is mixed with return air and distributed via supply fans before some of the return air is exhausted through relief dampers if needed to regulate pressure.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
27 views2 pages
Figure 3-10. Central HVAC System "Ventilating"
Ventilation systems have been used for hundreds of years to provide fresh air in buildings. Modern guidelines recommend supplying 15-25 cubic feet per minute of outside air per person for non-smoking areas and 50 cubic feet per minute for smoking areas. Central HVAC systems typically supply a mix of 20% outside air and 80% return air to ventilate and pressurize conditioned spaces. The outside air is mixed with return air and distributed via supply fans before some of the return air is exhausted through relief dampers if needed to regulate pressure.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2
Heating and Ventilating Systems
45 Figure 3-10. Central HVAC System “Ventilating” 46 HVAC Fundamentals
In many instances, local building codes, association guide-
lines, or government or company protocols stipulate the amount of ventilation required for buildings and work environments. Ventilation systems have been around for a long time. In 1490, Leonardo da Vinci designed a water driven fan to ventilate a suite of rooms. In 1660, a gravity exhaust ventilating system was used in the British House of Parliament. Then, almost two hundred years later, in 1836, the supply air and exhaust air ventilation system in the British House of Parliament used fans driven by steam engines. Today, ventilation guidelines are approximately 15 to 25 cfm (cubic feet per minute) of air volume per person of outside air (OA) for non-smoking areas, 50 cfm for smoking areas. Ventila- tion air may also be required as additional or “make-up” air (MUA) for kitchen exhausts, fume hood exhaust systems, and restroom and other exhaust systems. Maintaining room or condi- tioned space pressurization (typically +0.03 to +0.05 inches of water gage) in commercial and institutional buildings is part of proper ventilation. Figure 3-10 shows 20% of the total supply air is ventilation outside air (OA) and 80% is return air (RA). The outside air is brought (or forced) into the mixed air plenum by the action of the supply air fan. The outside air coming through the outside damper is mixed with the return air from the conditioned space. The return air dampers control the amount of return air. If the room pressure is too high, the exhaust air (EA) dampers open to let some of the return air escape to the outside, which relieves some of the pressure in the conditioned space. Exhaust air damp- ers are also called relief air dampers.
The Complete HVAC BIBLE for Beginners: The Most Practical & Updated Guide to Heating, Ventilation, and Air Conditioning Systems | Installation, Troubleshooting and Repair | Residential & Commercial