Design of Two-Way Slab: Structural Calculation Residential Building
Design of Two-Way Slab: Structural Calculation Residential Building
DESIGN PARAMETERS
f'c = 20 MPa Compressive strength of concrete
fy = 227 MPa Yield strength of steel bar
Ø= 10 mm Bar diameter
t= 100 mm Thickness of slab
L= 3.75 m Longer dimension of slab
B= 3.75 m Shorter dimension of slab
SUPPORT CONDITIONS
CASE 1 CASE 2 CASE 3 CASE 4 CASE 5 CASE 6 CASE 7 CASE 8 CASE 9
MOMENT COEFFICIENTS
-CaDL = 0.061 Negative moment coefficient along the shorter dimension due to dead load
-CaLL = 0.061 Negative moment coefficient along the shorter dimension due to live load
-CbDL = 0.033 Negative moment coefficient along the longer dimension due to dead load
-CbLL = 0.033 Negative moment coefficient along the longer dimension due to live load
+CaDL = 0.023 Positive moment coefficient along the shorter dimension due to dead load
+CaLL = 0.030 Positive moment coefficient along the shorter dimension due to live load
+CbDL = 0.020 Positive moment coefficient along the longer dimension due to dead load
+CbLL = 0.028 Positive moment coefficient along the longer dimension due to live load
LOCATION EQUATIONS MOMENT MTOTAL rreqd rused Spacing Sfinal Ductility Rebar spacing, mm
Negative -CaDLWuDLLa
2
4.70
Moment, Ma -C W L 2 7.31 0.00666 0.0067 157 157 PASS 10 mm diameter @ 150 mm
aLL uLL a 2.61
Negative -CbDLWuDLLb
2
2.54
Moment, Mb -C W L 2 3.96 0.003525 0.0047 223 200 PASS 10 mm diameter @ 200 mm
bLL uLL b 1.41
Positive +CaDLWuDLLa
2
1.77
Moment, Ma +C W L 2 3.06 0.002708 0.0036 291 200 PASS 10 mm diameter @ 200 mm
aLL uLL a 1.28
Positive +CbDLWuDLLb
2
1.54
Moment, Mb +C W L 2 2.74 0.002423 0.0032 325 200 PASS 10 mm diameter @ 200 mm
bLL uLL b 1.20