100% found this document useful (1 vote)
121 views1 page

JB00 B PPDC 020 0001 5

1. The document appears to be a piping and instrumentation diagram showing various pieces of equipment connected by pipes including production manifolds, gas coolers, choke valves, and flare headers. 2. Equipment is identified using identification tags connected by flow arrows showing the direction of flow between devices. 3. Notes provide additional information about equipment and pipe specifications.

Uploaded by

tariq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
121 views1 page

JB00 B PPDC 020 0001 5

1. The document appears to be a piping and instrumentation diagram showing various pieces of equipment connected by pipes including production manifolds, gas coolers, choke valves, and flare headers. 2. Equipment is identified using identification tags connected by flow arrows showing the direction of flow between devices. 3. Notes provide additional information about equipment and pipe specifications.

Uploaded by

tariq
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

4 7 1I

_-t::::=:::J>
+ - - ;~0H OOJ ll
NO E 5
A
TO PRODUCTION GAS
COOLER HC-020001
16" -PG-020-0002-6DA-G
J800-8 - PPDC- 020-0002
043- GT -0025
TO CHOKE VALVE
- ")- (C7 - 1:L LOW SIGNAL SELECTOR
01J-HY-022A

~ - )-·( (7'-q.l
020-Bl-0048 ~- --J JA00-8-PPOC-013-0002)

B
...-r - J -(('r ->.1 I
I lI TO CHOKE VALVE
LOW SIGNAL SELECTOR B
- - - j •(l1-b-~ ~H
020 H
- ---j
01 3-HY-012A
JAOO-B-PPOC-013-0007)
~
:L nlo~\2ol'- o·
1 -VH-043- 1102- 1 w1

Trim No. : VT -020-001J-6DA-G J0" - VH - 043- 11OJ -


VT -020-00 14-9DA-G
c NOTE 13 c
TO HP FLARE HEADER
JBOO- B-PPOC- 043-0001
FROM
PRODUCTION MANifOLD 16 • - PW- 020- 000 l-eDA- G 16"x20"
IJCOO-B-PPOC- 034-0003 ~ C}l---->="-"---11 1-~

Nl G

D D

020-BL - 00~

E ,--,
<£3-
6DA I9D; 1·9CA
90A"I"9CA
2
rnc:o::n--:>
3A

l iN SULAt D
TAG NO. VA-020001
INLET SEPARATOR
E

~
SERVICE
NOTE 7 20
~ 020· BL-0010
~ u -
002 00J LL SIZE (mm) 1900 ID X 9080 T/T
INTERFACE
I
I C0J 020- BL -0008 020-BL-0011 DESIGN 91.0 borg 0 126"C & -25'C
VALVE N01
INSULATEDI
t;•
\
020-BL-0022 I CONDITIONS

: 020 - BL- COO?\ 020-BL-0020 §~· TO CONDENSATE STABILISER


: 020 - BL-0004 I 020-BL-0006 FEED DRUM VL-022001
2" -PL-020-0010-~DA- G
JB00-8- PPOC- 022 - 0001
F ~ -- - ~2~-!~~.o~?II t:_:- - - - - - -------1 EL: MIN
F
VALVE NOT _ J
020- el- 0051 020- BL- 0034
6D~ I ~D!I JCA
INSULATED
NOTES (CONY
CO:ll-£='H---" . -y~
11. fOR GENERAL NOTES AND SYMBOLS REFER TO LEGEND SHEETS
020-BL-0013\ NO~ J020-GL-0041 NOTE 21
(UU00-8-PPOL-000-0001/2). G Nl
12. CONTROLLER OUTPUT TO BE DRIVEN TO MINIMUM AND SWITCHED TO MANUAL.
13. INLET SEPARATOR IS CARBON STEEL WITH 904L CLADDING. 038-BL-0047
TO PRODUCED WATER
I
..........-....
14. BRANCH CONNECTION AT 90' WITH FULL ENCIRCLEMENT PAD. DEGASSING DRUM V0-038001 CUENT
15. COMBINED CV OF 020-LV-001 AND BYPASS NOT TO EXCEED 12. 2"-W0-038-0001- 60A-G
· JBOO-B- PPOC-038-0001
G 16. REMOVABLE SPOOL TO ALLOW RODOING OF VA-02000 I 4" VESSEL DRAIN. G
17. REMOVABLE SPOOL ON 2" -W0-020-0012-60A fOR FUTURE INUECTION.
OF ANTI SCALE CHEMICALS. In Salah Gas
18. SP-29-011 CV NOT TO EXCEED 6.
L 41
~~ ~
19. HIGH PRESSURE DROP, ANCHOR SECURELY.
20. INSULATION. MOC-0058-U.
21. CHANGE TAG PI-0044J
OTE 16 "-.._ J020-GL-0042 NOTE
21

PROJECT
IIIBII A--
Kellogg Brown & Root

22. ADDEO FLOW TRANSi.jiTIER 020-FIT-001 4"x2" J020- GL- 0043 NOTE 21 IN SALAH PROJECT
020- BL-0026/ NOTE 18 EPC
NOTES GS liS AS- 8UII.T IIOC - 1077.1 TITLE
SIGNED DATE PIPING AND INSTRUMENT DIAGRAM
I. PREFIX fOR EACH ITEM AND LINE IS ASSET REFERENCE FOR KRECHBA FIELD : J AS·8Ull P HIOU J
2. IOD LENGTH OF STRAIGHT PIPE REQUIRED AT INLET TO SEPARATOR.(0=20") AS- 8UU IIOC-0058- U. ORIGIN
OKP 12/6/00
KRECHBA CPF
H 3. DELETED. AS· SUILT ISSU£ BY INLET SEPARATOR H
4. SUPPORT THE VALVE AND LINE ADEQUATELY FOR TWO PHASE FLOW. RE- ISSUED FOR COHSiRVCIION
KL 12/6/00
5. ALARM ONLY ON LOW LOW PRESSURE. ISSU£D FOR CONSTRucTION
6. THIS DRAWING WAS PREVIOUSLY ISSUED AS 6643-B-1-GJBA-DCH-BDP-020-00001. R( - ISWED FOR DESIGN Rev.
7. GLASS TYPE LEVEL GAUGE. NOT ISSUED
8. ONE INCH GLOBE VALVE WITH REDUCED TRIM. CONTROL VALVE AND BYPASS SIZES DETERMINE RE· ISWED FOR DESIGN
SIZE Of RELIEF VALVE ON CONDENSATE STABILISER DRUM. COMBINED CV LIMITED TO 5.5 R£\'ISION 5