Sifam

The document provides specifications for four types (19, 29, 39, 49) of Presentor meters in four styles (W, WF, M, B) for mounting in panels. It includes dimensions, cutouts, fixing stud locations, and other physical details to aid integration into control panels. Dimensions are provided in both millimeters and inches for the various meter components and overall envelopes.

Uploaded by

valimorsk ltd.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
103 views

Sifam

The document provides specifications for four types (19, 29, 39, 49) of Presentor meters in four styles (W, WF, M, B) for mounting in panels. It includes dimensions, cutouts, fixing stud locations, and other physical details to aid integration into control panels. Dimensions are provided in both millimeters and inches for the various meter components and overall envelopes.

Uploaded by

valimorsk ltd.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Presentor

Meter types 19, 29, 39, 49


Presentor Style W A
For back of panel mounting with
L CUT-OUT
only the scale and pointer visible.

Types: 19W, 29W, 39W, 49W

M CUT-OUT
B

N
METER

K
P
Meter barrel cut out 27.0mm/1.06”
Fixing studs M2.5x10.0mm/0.39” 6.00mm/0.24” hole required when
(except type 19: M2) optional front zero is specified

Presentor Style WF
A
For back of panel mounting with
L CUT-OUT
bezel and with only the scale and
pointer visible.

M CUT-OUT
Types: 19WF, 29WF, 39WF, 49WF
BEZEL

N
METER

K
Max panel thickness 4.0mm/0.16”

P
(except type 19: 3.0mm/0.12”)
Meter barrel cut out 27.0mm/1.06”
Fixing studs M2.5x10.0mm/0.39” 6.00mm/0.24” hole required when
(except type 19: M2) optional front zero is specified

Presentor Style M
For front of panel mounting with
A
lower mask.

Types: 19M, 29M, 39M, 49M

METER
B

Max panel thickness 6.0mm/0.24”


Meter barrel cut out 27.0mm/1.06”
Fixing studs M2.5x10.0mm/0.39”
(except type 19: M2)

Presentor Style B
For front of panel mounting with
A
full bezel.

Types: 19B, 29B, 39B, 49B

METER
B

Max panel thickness 6.0mm/0.24”


Meter barrel cut out 27.0mm/1.06”
Fixing studs M2.5x10.0mm/0.39”
(except type 19: M2)
19W 29W 39W 49W
C D E F mm inches mm inches mm inches mm inches
A 43.9 1.73 76.1 2.99 94.0 3.70 124.0 4.88
B 21.0 0.82 33.3 1.31 41.9 1.65 57.1 2.25
C 11.5 0.45 11.5 0.45 11.5 0.45 11.5 0.45
D 37.2 1.46 38.7 1.52 39.2 1.54 40.3 1.59
E 1.50 0.06 1.80 0.07 2.00 0.08 2.10 0.08
F 32.0 1.26 47.8 1.88 57.2 2.25 92.0 3.62
G 4.70 0.18 15.0 0.59 20.9 0.82 26.9 1.06
Fixing studs in Fixing studs in
H same horizontal 9.70 0.38 8.60 0.34 same horizontal

J
METER plane above C/L plane above C/L
J 7.0mm/0.28” 38.0 1.50 48.5 1.91 7.0mm/0.28”

K 37.9 1.49 58.8 2.32 72.4 2.85 93.0 3.66

G
BARREL L 42.4 1.66 73.66 2.90 91.50 3.60 121.00 4.76
M 20.20 0.79 32.26 1.27 40.50 1.59 55.50 2.19
N 2.0 0.08 3.90 0.15 5.70 0.22 10.6 0.42
P 9.90 0.39 16.1 0.63 20.4 0.80 21.5 0.85

H
Ø26.0
1.02"

19WF 29WF 39WF 49WF


C D E Q mm inches mm inches mm inches mm inches
A 49.2 1.94 82.8 3.26 101.0 3.98 131.0 5.16
B 27.0 1.06 41.6 1.64 50.5 1.99 65.6 2.58
F
C 11.5 0.45 11.5 0.45 11.5 0.45 11.5 0.45
D 40.8 1.61 42.9 1.69 43.4 1.71 44.5 1.75
E 1.50 0.06 1.50 0.06 1.6 0.06 1.70 0.07

R
F 32.0 1.26 47.8 1.88 57.2 2.25 92.0 3.62
BEZEL G 6.10 0.24 16.7 0.66 22.7 0.89 28.7 1.13
Fixing studs in Fixing studs in
H same horizontal 9.70 0.38 8.60 0.34 same horizontal
METER plane above C/L plane above C/L

J
J 7.0mm/0.28” 38.0 1.50 48.5 1.91 7.0mm/0.28”

K 40.6 1.60 62.2 2.45 76.1 2.99 96.5 3.80

G
L 47.0 1.85 80.0 3.15 98.0 3.86 128.0 5.04
BARREL
M 24.0 0.94 37.0 1.46 46.0 1.81 61.0 2.40
N 5.20 0.20 8.10 0.32 10.2 0.40 15.1 0.59
P 8.00 0.31 13.7 0.54 17.7 0.70 18.8 0.74
Q 58.5 2.30 90.6 3.57 108.6 4.28 139.7 5.50
H

Ø26.0
R 6.80 0.27 10.3 0.41 12.8 0.50 15.4 0.61
1.02"

19M 29M 39M 49M


mm inches mm inches mm inches mm inches
A 43.9 1.73 76.1 2.99 94.0 3.70 124.0 4.88
C D E F B 38.8 1.53 60.3 2.37 74.0 2.91 94.6 3.72
C 11.5 0.45 11.5 0.45 11.5 0.45 11.5 0.45
D 31.2 1.23 30.5 1.20 30.2 1.19 30.2 1.19
E 7.50 0.30 10.0 0.39 11.0 0.43 12.2 0.48
F 32.0 1.26 47.8 1.88 57.2 2.25 92.0 3.62
G 4.20 0.17 14.2 0.56 20.0 0.79 26.1 1.03
Fixing studs in Fixing studs in
H same horizontal 9.70 0.38 8.60 0.34 same horizontal
plane above C/L plane above C/L
J 7.0mm/0.28” 38.0 1.50 48.5 1.91 7.0mm/0.28”
J

METER
G

BARREL
H

Ø26.0
1.02"

19B 29B 39B 49B


mm inches mm inches mm inches mm inches
A 46.0 1.81 79.5 3.13 97.5 3.84 127.7 5.03
C D E F B 40.0 1.57 61.9 2.44 76.4 3.01 96.6 3.80
C 11.5 0.45 11.5 0.45 11.5 0.45 11.5 0.45
D 31.2 1.23 30.5 1.20 30.2 1.19 30.2 1.19
E 7.50 0.30 10.0 0.39 11.0 0.43 12.2 0.48
F 32.0 1.26 47.8 1.88 57.2 2.25 92.0 3.62
G 4.8 0.19 15.0 0.59 20.8 0.82 26.9 1.06
Fixing studs in Fixing studs in
H same horizontal 9.70 0.38 8.60 0.34 same horizontal
plane above C/L plane above C/L
J 38.0 1.50 48.5 1.91
J

7.0mm/0.28” 7.0mm/0.28”
METER
G

BARREL
H

Ø26.0
1.02"
Presentor
Terminals Standard ranges
If the required range is not indicated by a symbol please enquire as it may be possible to supply to
Bent tabs option your special requirements
4.5 mm DC AC
0.18" Range
V µA mA A V µA mA A
0-1 ●* ● ● ● ● ■
0-1.5
0-2 ● ● ●
0-2.5 ◆
Screw terminals option 0-3 ● ● ◆ ●
12.0 mm
All types/styles M2.5 terminals 0.47" 0-5 ● ● ◆ ● ● ■
0-10 ● ● ◆ ● ● ■
10.3 mm 0-12
6.0 mm
0.24"

0.41"
0-15 ●
0-20 ● ● ▲ ● ● ■
0-25 ▲
0-30 ● ● ▲ ● ● ■
0-40 ● ● ▲ ● ●
Flying leads option Also available with reduced barrel 0-50 ● ● ● ▲ ● ● ● ■
depth - special order only 0-100 ● ● ● ▲ ● ● ● ■

Type Barrel Depth 0-120 ● ● ●

19 29.2mm/1.15* 0-150 ● ● ● ■

29 28.5mm/1.12* 0-200 ● ● ● ▲ ● ● ■

39 28.2mm/1.11* 0-250 ● ● ● ▲ ● ●

49 28.3mm/1.11* 0-300 ▲
0-400 ●
0-500 ● ● ▲ ● ■
Illumination
0-1000 ✔ ▲ ✔
This is available in either of the two forms shown below and should 0-1500 ✔ ▲ ✔
be specified at the time of ordering meters. 0-2000 ✔ ▲
Please contact the sales office for full information and drawings.
● Self contained. ✔ Complete with external resistance box.
Overhead ◆ Complete with external tag board. * Millivoltmeters can be supplied on request.
Available for types 19W, 19WF, 29W, 29WF, 39W, 39WF ▲ 75mV - external shunt required. ■ Complete with external transformer.
Unit contains Ø6mm festoon style lamp available in 6V, 12V, or 24V
Illumination bracket assembly Terminal resistance
Range Tolerance ± 15% Range Tolerance ± 15%
50µA 2000Ω 250µA 255Ω
100µA 1000Ω 500µA 155Ω
200µA 365Ω 1mA 50Ω

Accuracy
Type Scale length DC AC Rectifier
19 34.0mm/1.34” ±2.5% ±2.5%
Panel 29 60.0mm/2.36” ±1.5% ±2.5%
Light Box 39 78.0mm/3.07” ±1.5% ±2.5%
Available for all styles of types 29, 39 49 100.0mm/3.94” ±1.5% ±1.5%
which require translucent dials. The
meter fixing studs occupy different
positions and rectangular panel Weight
cut-outs are required for styles M, B. Type Nett Weight Type Nett Weight
Unit is available with either festoon 19 40g/1.4oz 39 90g/2.8oz
style or T1 3/4 flanged lamps in 6V, 29 65g/2.3oz 49 130g/4.6oz
12V, 24V. T1 3/4 flanged LEDs are
As part of our policy of continuous product improvement we reserve the right to change
also available in either 12V or 24V.
specifications at any time.
Produced in the UK by SLS Communications 2500UK/02/99

Certificate No. 851037

SIFAM LIMITED
WOODLAND ROAD TORQUAY DEVON As part of our policy of

TQ2 7AY ENGLAND continuous product

TEL: 01803 407733 FAX: 01803 407740 improvement we reserve

[email protected] the right to change

www.sifam.com specifications at any time.

SIFAM – The plastics and measurement technology group