This document outlines the lessons in a Radiographic Testing Level III course. Lesson 1 covers basic radiographic principles including radiation interaction, exposure calculations, and image quality. Lesson 2 discusses darkroom facilities, film processing techniques, and causes of unsatisfactory radiographs. Lesson 3 covers indications, discontinuities, and defects. Lessons 4-9 review various manufacturing processes and associated discontinuities in castings and welds. Lesson 10 discusses standards, codes, and employer procedures for radiographic testing.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0 ratings0% found this document useful (0 votes)
131 views3 pages
RT Outline Training LV III
This document outlines the lessons in a Radiographic Testing Level III course. Lesson 1 covers basic radiographic principles including radiation interaction, exposure calculations, and image quality. Lesson 2 discusses darkroom facilities, film processing techniques, and causes of unsatisfactory radiographs. Lesson 3 covers indications, discontinuities, and defects. Lessons 4-9 review various manufacturing processes and associated discontinuities in castings and welds. Lesson 10 discusses standards, codes, and employer procedures for radiographic testing.
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3
Radiographic Testing Level III
Lesson 1 Review of Basic Radiographic Principles
- Interaction of radiation with matter - Math review - Exposure calculations - Geometric exposure principles - Radiographic-image quality parameters
Lesson 2 Darkroom Facilities, Techniques and Processing
- Facilities and equipment Automatic film processor versus manual Processing Safe lights Viewer lights Loading bench Miscellaneous equipment - Film loading General rules for handling unprocessed film Types of film packaging g Cassette-loading techniques for sheet and roll - Protection of radiographic film in storage - Processing of film - manual Developer and replenishment Stop bath Fixer and replenishment Washing Prevention of water spots Drying - Automatic film Processing - Film filing and storage Retention-life measurements Long-term storage Filing and separation techniques - Unsatisfactory radiographs - causes and cures High film density Insufficient film density High contrast Low contrast Poor dentition Fog Light leaks Artifacts - Film density Step-wedge comparison film Densitometers
Composite materials in concrete construction proceedings of the international seminar held at the University of Dundee Scotland UK on 5 6 September 2002 1st ed Edition Paine - The ebook in PDF format is ready for immediate access