Portable Manual: Ir2030/2025/2022/2018 Series
Portable Manual: Ir2030/2025/2022/2018 Series
iR2030/2025/2022/2018 Series
Aug 8 2007
Application
This manual has been issued by Canon Inc. for qualified persons to learn technical theory, installation, maintenance, and repair
of products. This manual covers all localities where the products are sold. For this reason, there may be information in this
manual that does not apply to your locality.
Corrections
This manual may contain technical inaccuracies or typographical errors due to improvements or changes in products. When
changes occur in applicable products or in the contents of this manual, Canon will release technical information as the need
arises. In the event of major changes in the contents of this manual over a long or short period, Canon will issue a new edition
of this manual.
The following paragraph does not apply to any countries where such provisions are inconsistent with local law.
Trademarks
The product names and company names used in this manual are the registered trademarks of the individual companies.
Copyright
This manual is copyrighted with all rights reserved. Under the copyright laws, this manual may not be copied, reproduced or
translated into another language, in whole or in part, without the written consent of Canon Inc.
Caution
Use of this manual should be strictly supervised to avoid disclosure of confidential information.
Introduction
Symbols Used
This documentation uses the following symbols to indicate special information:
Symbol Description
Indicates an item requiring disconnection of the power plug from the electric outlet.
Indicates an item intended to provide notes assisting the understanding of the topic in question.
Memo
The descriptions in this Service Manual are subject to change without notice for product improvement or other purposes, and major changes will be com-
municated in the form of Service Information bulletins.
All service persons are expected to have a good understanding of the contents of this Service Manual and all relevant Service Information bulletins and be
able to identify and isolate faults in the machine."
Contents
Contents
5.1.3.12 <024: pseudo RBT transmission level at time of fax/tel switchover> ........................................29
5.1.3.13 <025: Answering machine connection function signal detection time> ....................................29
5.1.3.14 <027: V.21 low-speed flag preamble identification length> ........................................................29
5.1.3.15 <055: Acquisition period of environmental log data> ...................................................................29
5.1.3.16 <056 - 061: Count type select > ......................................................................................................29
5.1.4 Scanner Function Settings (SCANNER) .................................................................................................33
5.1.4.1 Setting of Bit Switch ............................................................................................................................33
5.1.4.2 Numeric Parameter Functional configuration..................................................................................33
5.1.4.3 <024:CIS scan position during ADF scanning> ..............................................................................34
5.1.4.4 <026:Distance from the standby position of CIS to the shading start point> .............................34
5.1.4.5 <031Vertical scan start position adjustment> .................................................................................34
5.1.4.6 <032Horizontal scan start position adjustment>.............................................................................35
5.1.4.7 <033Vertical scan magnification correction> ..................................................................................35
5.1.4.8 <035: - 036:Reader motor speed change>......................................................................................35
5.1.4.9 <041: Vertical scan start position adjustment (when scanning on a document fed from ADF)>
35
5.1.4.10 <042: Horizontal scan start position adjustment (when scanning on a document fed from
ADF)> ............................................................................................................................................................35
5.1.4.11 <043: Horizontal scan end position correction ((copy:scanning on ADF)> ..............................35
5.1.4.12 <044: Horizontal scan end position correction (superfine:scanning on ADF)>........................35
5.1.4.13 <045: Horizontal scan end position correction (fine:scanning on ADF)>..................................35
5.1.4.14 <046: Horizontal scan end position correction (standard:scanning on ADF)> ........................35
5.1.4.15 <047: Vertical scan magnification correction (when scanning on a document fed from ADF)>
35
5.1.4.16 <048: Horizontal scan magnification correction (when scanning on a document fed from
ADF)> ............................................................................................................................................................35
5.1.4.17 <193: ADF special standard-sized paper: LGL misidentification-ready>..................................35
5.1.4.18 <194: ADF special standard-sized paper: LTR misidentification-ready>..................................36
5.1.4.19 <195: ADF special standard-sized paper: LTR_R misidentification-ready> ............................36
5.1.4.20 <196: Shading Target Value (Red)>...............................................................................................36
5.1.4.21 <197: Shading Target Value (Green)> ...........................................................................................36
5.1.4.22 <198: Shading Target Value (Blue)> ..............................................................................................36
5.1.4.23 <213: XYZ correction value (X) of standard white plate> (if equipped with SEND functions)).
36
5.1.4.24 <214: XYZ correction value (Y) of standard white plate> (if equipped with SEND functions) ..
36
5.1.4.25 <215: XYZ correction value (Z) of standard white plate> (if equipped with SEND functions) ..
36
5.1.5 Printer Function Settings (PRINTER) ......................................................................................................37
5.1.5.1 Service Soft Switch Settings ..............................................................................................................37
5.1.5.2 Numeric Parameter Settings (NUMERIC Param.) .........................................................................40
5.1.5.3 Setting of Cassette (CST) ..................................................................................................................43
5.1.6 Network Parameter Settings (NETWORK) .............................................................................................43
5.1.6.1 Confirmation of contents of CA certificate .......................................................................................43
5.1.7 Setting of System Functions (SYSTEM)..................................................................................................43
5.1.7.1 Bit Switch Settings ...............................................................................................................................43
5.1.8 Registration of Accessories (ACC) ...........................................................................................................44
5.1.8.1 Accessory Registration .......................................................................................................................44
5.1.9 License Management (LMS) .....................................................................................................................44
5.1.9.1 Outline ...................................................................................................................................................44
Contents
Chapter 8 Upgrading
8.1 Upgrading............................................................................................................................................................97
8.1.1Overview of Upgrade (LCD type) ..............................................................................................................97
8.1.2Overview of Upgrade (Touch panel type) ................................................................................................97
8.1.3Overview of Service Support Tool (LCD type) ........................................................................................98
8.1.4Overview of Service Support Tool (Touch panel type) ..........................................................................98
Chapter 1
1.1.1 Overview
0017-5958
The machine has parts that must be replaced on a periodical basis to ensure a specific level of functional performance. (The loss of the function of any of these parts
will significantly affect the machine performance, regardless of the presence/absence of external changes or damage.)
If possible, schedule the replacement so that it coincides with a scheduled service visit.
The timing of replacement may vary depending on the site environment or user habit.
The reader unit does not have parts that require periodical replacement.
The printer unit does not have parts that require periodical replacement.
1.2.1 Overview
0017-5962
1
Chapter 1
As of Jun. 2007
Ref. Parts name Parts No. Q'ty Life Remarks
[1] Cassette feed roller FF6-1621-000 1 100K The 2-stage cassette type uses two rollers.
[2] Cassette separation roller FF6-1621-000 1 100K The 2-stage cassette type uses two rollers.
[3] Manual feed pickup roller FL2-3202-000 1 150K
[4] Manual feed separation pad FL2-3201-000 1 150K
[5] Devrloping unit FM2-3286-000 1 150K
[6] Transfer roller FC6-4313-000 1 150K
[7] Fixing unit (100V) FM3-3652-000 1 150K
Fixing unit (120V) FM3-3651-000 1 150K
Fixing unit (230V) FM3-3650-000 1 150K
The value is the mean value collected from the results of evaluation. The parts number may change because of changes in design.
[7]
[3]
[4]
[6]
[5]
[1]
[2]
F-1-1
The reader and printer unit does not have items that require scheduled servicing.
Be sure to clean the copyboard glass and the ADF reading glass during every service visit.
2
Chapter 2
2.1.2 Procedure after Replacing the CIS (Touch panel If you have replaced the image processor PCB with a new one, perform the
following operations:
type) - Using the service support tool, download the latest firmware (System/
0017-5980
3
Chapter 2
- Read position adjustment (Stream reading: Only when the ADF is installed) 3) Select "#SYSTEM SW" using or , and then press the OK.
1) Enter the service mode. 4) Press the following keys to display "SW003".
Sequentially press the Additional functions key, 2 key, 8 key, and Additional # > 0 key > 3 key
functions key on the operation panel. Message: #SYSTEM SW003 00001000
2) Press the arrow key on the touch panel to display "TEST MODE". 5) Check that Bit-6 (second from left) is set to set to "1". If Bit-6 is not set to
3) Press [OK].
4) Press the [2] key to display "SCAN TEST". "1", position the cursor at this bit using or and then press the 1 key.
5) Press the [3] key to display "SHEET POS ADJ". Message: #SYSTEM SW003 01001000
6) Press [OK].
The optical system starts scanning. Several seconds later, automatic adjust- 6) Press the OK key. Check that "SW003" changes to "SW004".
ment of the reading position finishes and "OK" appears. Message: #SYSTEM SW004 00000000
7) Press the Reset key to exit the service mode.
8) Turn off the main power switch, and then turn it on again.
9) Open My Computer on the PC to check that the "Removal Disk" icon is
If automatic adjustment fails, "NG" appears. Perform the following displayed.
procedure: 10) Write the user data (address_book.abk and user_data.dat) copied onto
Clean the white roller of the DADF and the document glass of the host the Desktop as described in "a. Exporting user data" over the removable
machine, and then retry auto adjustment. disk.
11) Disconnect the USB cable from the machine.
2.3.3 Procedure after Replacing the USB Memory (Touch 12) Turn off the main power switch of the machine.
13) Perform steps 1) to 4) again to reset Bit-6 of "SW003" to "0".
panel type) 14) Press the OK key. When "SW003" changes to "SW004", press the Reset
0017-5985
MEMO:
You also need to perform these operations after formatting the damaged
USB memory.
- Performing the all-clear operation in the service mode (#CLEAR > ALL)
erases/initializes the user data such as address data and user mode settings.
Be sure to back up the user data with the data export function before starting
the all-clear operation, and then load the user data with tbe data import
function.
- To export and import user data, a PC and a USB cable are required. Have
them on hand.
4
Chapter 2
5
Chapter 3
T-3-1
Display
Detail Code Main Cause/Symptom Countermeasure
Code
E000 0000 Startup error
The temperature detected by the main or sub thermistor does - Check the fixing film connector.
not rise to the specified value during startup control. - Replace the fixing film unit.
- Replace the DC controller PCB.
7
Chapter 3
Display
Detail Code Main Cause/Symptom Countermeasure
Code
E196 0001 Image processor PCB failure
Error on writing and readout ROM of image processor PCB - Putting the switch on/off of the power supply.
(mainn ROM). - Replace the image processor PCB.
E730 0000 Inside error of the image processor PCB (PDL system error)
The inside of the image processor PCB is faulty. - Putting the switch on/off of the power supply.
- Replace the image processor PCB.
8
Chapter 3
Display
Detail Code Main Cause/Symptom Countermeasure
Code
E744 Language file/boot ROM/USB memory error
0001 The language file version does not match Bootable. Download a language file of the correct version.
0002 The language file is longer than the permitted size. Download a language file of the correct version.
0003 The language file version does not match Bootable. Download a language file of the correct version.
0004 Language file read error Download a language file of the correct version.
E805 0000 Fan failure
The fan is faulty. - Check the fan connector.
- Replace the fan.
- Replace the DC controller PCB.
E808 0000 Fixing drive circuit failure
- The heater does not turn on. - Check the connector of the fixing film unit.
- A fixing drive motor failure was detected. - Replace the fixing film unit.
- Replace the fixing drive motor.
- Replace the DC controller PCB.
- Replace the power supply PCB.
9
Chapter 3
T-3-2
T-3-3
T-3-4
10
Chapter 3
T-3-5
T-3-6
11
Chapter 3
12
Chapter 4
T-4-1
Item Settings
Initial Function Select Initial Function: Copy*1, Send, Scan
Set System Monitor Screen as initial function: On, Off*1
Set [Device] as the default for System Monitor: On*1, Off
Register Paper Type Paper Drawer 1, Paper Drawer 2*2, Paper Drawer 3*2, Paper Drawer
4*2: Plain*1, Recycled, Color, 3-hole punch, Bond, Heavy Paper 1
13
Chapter 4
T-4-2
Item Settings
Date & Time Settings Date and Time Setting (12 digit number)
Time Zone Settings:
GMT -12:00 to GMT +12:00;
GMT -5:00*1
Daylight Saving Time Settings: On, Off*1
T-4-3
Item Settings
Transfer Roller Cleaning Press [Start].
Drum Cleaning Press [Start].
Fixing Unit Cleaning Cleaning Sheet Print, press [Start].
Feeder Cleaning Press [Start].
Special Mode M Standard*1, Low, Moderate, High
Special Mode N Manual (Medium, High), Off
Special Mode O Stack Bypass: Medium, High, Off*1
Drawer: Medium, High, Off*1
Special Mode P Off*1, Medium, High
Bond Special Fixing Mode On, Off*1
Special Mode S Speed Priority 1, Speed Priority 2, Off*1
Rotate Collate Adjustment Speed Priority 1*1, Speed Priority 2, Image Priority
Auto Adjustment for Dirty Feeder On*1, Off
T-4-4
Item Settings
Settings TX Report: On, For Error Only*1, Off
Report With TX Image: On*1, Off
Activity Report
Auto Print: On*1, Off
Send/Receive Separate: On, Off*1
T-4-5
Item Settings
System Manager Settings
System Manager 32 characters maximum
System Manager ID Seven digit number maximum
System Password Seven digit number maximum
Department ID Management
Department ID Management On, Off*1
Register ID/Password Register, Edit, Erase, Set page limits
Page Totals Clear, Clear All Totals, Print List
Allow ID Unknown Printer Jobs On*1, Off
14
Chapter 4
Item Settings
Allow ID Unknown Remote Scan Jobs On*1, Off
Network Settings
Forwarding Settings
Receive Type*2 All*1, Fax, I-Fax
Validate/Invalidate On, Off*1
Register Condition Name: 50 characters maximum
Forwarding Conditions
Receive Type: Fax*2, I-Fax
Erase Yes, No
Print List Yes, No
Device Info Settings
Device Name 32 characters maximum
Location 32 characters maximum
User ID Management On, Off*1
Communications Settings
E-mail/I-Fax Settings Maximum TX Data Size: 0 to 99 MB; 3 MB*1
Divided TX over Max.Data Size: On, Off*1
Default Subject: 40 characters maximum; Attached Image*1
Fax Settings*2 Send Start Speed: 33600 bps*1, 14400 bps, 9600 bps, 7200 bps, 4800
bps, 2400 bps
Receive Start Speed: 33600 bps*1, 14400 bps, 9600 bps, 7200 bps,
4800 bps, 2400 bps
T-4-6
Item Settings
Image Orientation Priority On, Off*1
Auto Orientation On*1, Off
Standard Settings Store, Initialize
Initialize Copy Settings Yes, No
15
Chapter 4
T-4-7
Item Settings
Common Settings: TX Settings
Unit Name 24 characters maximum
Data Compression Ratio High Ratio, Normal*1, Low Ratio
Retry Times 0 to 5 times; 3 times*1
Edit Standard Send Settings Store, Initialize
TX Terminal ID On: Option (Printing Position, Telephone # Mark*2)
Gamma Value for Color Send Jobs Gamma 1.0, Gamma 1.4, Gamma 1.8*1, Gamma 2.2
Sharpness 1 to 7 levels, 4*1
Register Favorites Button M1 to M18
Color TX Scan Settings Speed Priority*1, Image Priorit
Default Screen for Send Favorite Buttons, One-touch Buttons, Initial Function*1
Initialize TX Settings Yes, No
Common Settings: RX Settings
2-Sided Print On, Off*1
Select Cassette Switch A: On*1, Off
Switch B: On*1, Off
Switch C: On*1, Off
Switch D: On*1, Off
T-4-8
Item Settings
DEFAULT PAPERSIZE LTR*, STMT, EXECUTIV, ISO-B5, ISO-C5, COM10,
MONARCH, DL, A4, A3, B4, B5, A5, 11X17, LGL
DEFAULT PAPERTYPE PLAIN PAPER*, COLOR, RECYCLED, HEAVY PAPER 1,
HEAVY PAPER 2, HEAVY PAPER 3, BOND, 3-HOLE PUNCH
PAPER, TRANSPARENCY, LABELS, ENVELOPE
COPIES 1 to 999; 1*
2-SIDED PRINTING OFF*, ON
PRINT QUALITY
IMAGE REFINEMENT ON*, OFF
DENSITY 9 levels; 5*
TONER SAVER OFF*, ON
PAGE LAYOUT
BINDING LONG EDGE*, SHORT EDG
16
Chapter 4
Item Settings
MARGIN INCHES*: -01.90 INCHES to 01.90 INCHES; 00.00 INCHES*
MM: -50.0 MM to 50.0 MM; 0.0 MM*
AUTO ERROR SKIP OFF*, ON
ERROR TIME OUT ON* (TIME OUT PERIOD: 5 to 300 SEC), OFF; 15 SEC*
COLLATE OFF*, COLLATE, ROTATE + COLLATE*1, ROTATE +
GROUP*1, OFFSET + COLLATE*2, OFFSET + GROUP*2,
STAPLE*2 (STAPLE POSITION: TOP LEFT*, TOP RIGHT,
BOTTOM LEFT)
T-4-9
Item Settings
Register Address: Register New Address
Fax*2 Fax Number: 120 characters maximum
Option: Sending Speed, Long Distance, ECM TX
Register Name: 16 characters maximum
17
Chapter 4
When multiple users use the machine, it is necessary to advise each user to set the system management information.
Setting ID and password of system administrator on the operation unit under (Additional functions key) > [System management setting] > [Setting of system ad-
ministrator's information] has an effect of restraining the third person from falsifying information, for the ID and password are required when a user carries out an
important setting of the machine.
Under the environment that the setting is not done, if a user who does not sufficiently know operation situation of the machine tries to change the setting, following
troubles may occur.
- When the user changes [User ID Management] from [off] to [on], copying operation cannot be done unless ID and password are input.
- When each setting is changed on the network from RUI, that enables to falsify data of address book or delete log.
- When TCP/IP fixed address is changed on the network setting, printing operation via network cannot be done until the port setting is changed.
- When usage restriction of USB device is changed to [on], printing operation via USB becomes disabled.
Function:
If Department is registered in Department ID Management, users are required to input the Department ID and password when inputting data from the operation
unit of the machine. Also, the registration enables to restrict usage and control the usage number of times of Total Parts, Copy, B&W Scan, Color Scan, or Print.
Setting method:
Register Department ID in Department ID Management under Additional Functions key>System Setting.
Operation outline:
Department ID can be registered in [Department ID management] from the operation unit of the machine even though [System Manager Settings] is not done.
When registering data in [Department ID Management] using RUI, you need to register yourself as a system manager in [System Manager Settings] and login
as a system manager.
18
Chapter 5
The items registered and set by each of these switches comprise 8-bit switches. The figure below shows which numbers are assigned to which bits. Each bit has a
value of either 0 or 1.
t2
t1
t7
t6
t5
t4
t3
t0
Bi
Bi
Bi
Bi
Bi
Bi
Bi
Bi
#SSSW
001 0 0 0 0 0 0 0 0
F-5-1
Do not change service data identified as "not used"; they are set as initial settings.
5.1.1.2 SSSW-SW01
5.1.1.2.1 List of Functions
0017-6053
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-1
Bit Function 1 0
1 not used - -
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 not used - -
T-5-2
Bit Function 1 0
0 not used - -
1 not used - -
19
Chapter 5
Bit Function 1 0
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
Use it to enable/disable transmission of a 1080-Hz tonal signal before transmission of the CED signal.
Select 'transmit' if errors occur frequently because of an echo when reception is from overseas.
Memo:
Any of the following error code may be indicated because of an echo at time of reception
##0005, ##0101, ##0106, ##0107, ##0114, ##0200, ##0201, ##0790
5.1.1.4 SSSW-SW04
5.1.1.4.1 List of Functions
0017-6057
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-3
Bit Function 1 0
0 not used - -
1 not used - -
3 Reception mode after CFR signal transmission high speed high speed/low speed
4 the length of the period of ignoring low speed signals after 1500 ms 700 ms
CFR output
5 CI signal frequency check at the time of PBI setting Check Not
Use it to select the number of last flag sequences for a protocol signal (transmission speed at 300 bps). Select '2' if the other party fails to receive the protocol signal
properly.
Memo:
Any of the following error codes may be indicated at time of transmission
##0100, ##0280, ##0281, ##0750, ##0753, ##0754, ##0755, ##0758, ##0759, ##0760, ##0763 ##0764, ##0765, ##0768, ##0769,##0770, ##0773, ##0775, ##0778,
##0780, ##0783, ##0785, ##0788
Use it to select an appropriate reception mode after transmission of the CFR signal.
If errors occur frequently at time of reception because of the condition of the line, select 'high speed' for reception mode and, at the same time, selects 'do not receive'
for 'ECM reception.'
Memo:
Any of the following error codes may be indicated at time of reception because of line condition
##0107, ##0114, ##0201
Be sure to change bit 4 before changing this bit; if errors still occur, change this bit.
When 'high speed' is selected, only high-speed signals (images) will be received after transmission of the CFR signal.
20
Chapter 5
Use it to select the time length during which low-speed signals are ignored after transmission of the CFR signal.
If the condition of the line is not good and, therefore, the reception of image signals is difficult, select '1500 ms.'
5.1.1.4.5 Detailed Discussions of Bit 5
0017-8523
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
In the countries that need approval of CI signal frequency check, no checking on frequency set at PBX when changing the frequency to PSTN setting and PBX
setting for frequency checks.
5.1.1.4.6 Detailed Discussions of Bit 6
0017-6063
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Selects whether or not to transmit CED signals during manual reception. If the other fax does not transmit even when you start manual reception, select "Transmit-
ted" for the CED signal.
5.1.1.5 SSSW-SW05
5.1.1.5.1 List of Functions
0017-6065
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-4
Bit Function 1 0
0 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 not used - -
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images read in text mode.
Scanning direction in conversion follows the Bit 2 setting of SW14.
5.1.1.5.3 Detailed Discussions of Bit 2
0017-6067
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Use it to enable/disable millimeter/inch conversion in sub scanning direction for images read in text/photo mode while bit 1 is set to '1'.
Scanning direction in conversion follows the Bit 2 setting of SW14.
5.1.1.6 SSSW-SW12
5.1.1.6.1 List of Functions
0017-6068
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
21
Chapter 5
T-5-5
Bit Function 1 0
2 not used - -
3 not used - -
6 not used - -
7 Respective page timer settings for transmission and for enable do not enable
reception
The machine will stop the ongoing communication if the transmission/reception of a single original page takes 32 min or more. To use the timer for a purpose other
than this function, refer to the tables that follow, and select an appropriate time length.
When 'do not enable' is selected using bit 7, the time-out length for a single page for all modes will depend on the setting of bit 0 and bit 1.
T-5-6
Time-Out Length for Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Transmission/Reception
8 min 0 * * * * * 0 0
16 min 0 * * * * * 0 1
32 min 0 * * * * * 1 0
64 min 0 * * * * * 1 1
T-5-7
Time-Out Length for Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Transmission (in text
mode)
8 min 1 * * * * * 0 0
16 min 1 * * * * * 0 1
32 min 1 * * * * * 1 0
64 min 1 * * * * * 1 1
T-5-8
Time-Out Length for Bit7 Bit6 Bit5 Bit4 Bit3 Bit2 Bit1 Bit0
Reception
8 min 1 * 0 0 * * * *
16 min 1 * 0 1 * * * *
32 min 1 * 1 0 * * * *
64 min 1 * 1 1 * * * *
5.1.1.7 SSSW-SW13
5.1.1.7.1 List of Functions
0017-6069
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-9
Bit Function 1 0
0 not used - -
22
Chapter 5
Bit Function 1 0
1 not used - -
2 Convert "inch" into "mm" when transmitting the received convert do not convert
image data
3 not used - -
4 not used - -
5 not used - -
6 not used - -
7 not used - -
It converts "inch" into "mm" when transmitting the received image data.
Scanning direction in conversion follows the Bit 2 setting of SW14.
5.1.1.8 SSSW-SW14
5.1.1.8.1 List of Functions
0017-6071
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-10
Bit Function 1 0
0 not used - -
1 not used - -
2 direction of scanning for inch/mm conversion both main and sub sub scanning
scanning directions direction only
3 not used - -
5 not used - -
6 not used - -
7 not used - -
Use it to specify whether to convert or not convert an inch-configuration resolution into a millimeter-configuration resolution for image read in G3 transmission:
either in sub scanning direction only or in both main and sub scanning directions. The setting is valid only when bit 1 of SW05 of #SSSW is set to '1'.
5.1.1.8.3 Detailed Discussions of Bit 4
0017-6073
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Use it to specify whether to declare or not declare an inch-configuration resolution to the other machine for G3 communication: if 'declare' is selected, the machine
will indicate that it reads and records at an inch-configuration resolution using the DIS, DCS, or DTC signal.
5.1.1.9 SSSW-SW25
5.1.1.9.1 List of Functions
0017-8526
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-11
Bit Function 1 0
0 procedure of V.8 on the initiation side receiver's number initial call number
1 not used - -
23
Chapter 5
Bit Function 1 0
4 not used - -
5 not used - -
6 not used - -
7 not used - -
Transmitted telephone number could be selected on the report indication after the transmission.
If the "Initiation number" is selected, report will indicate the telephone number of the initiation side.
If the "Receiver's number" is selected, report will indicate the phone number (CSI signal data) which is sent by the receiver's side.
5.1.1.9.3 Detailed Discussions of Bit 2
0017-8529
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
At "1" on this Bit, ignore the void CSI if received and if the dial has been made at this point, the dialed number will be indicated on the LCD/ Report screen.
At "0" on this Bit, even though the dialed number is acknowledged, LCD/Report screen will indicate nothing.
5.1.1.10 SSSW-SW28
5.1.1.10.1 List of Functions
0017-6074
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-12
Bit Function 1 0
6 not used - -
7 not used - -
24
Chapter 5
Select whether to declare the V.8 protocol in DIS signal for reception. If NO is selected, the V.8 protocol cannot be used because it is not declared in DIS signal.
The V.8 late start is not executed during manual reception regardless of this setting.
5.1.1.10.6 Detailed Discussions of Bit 4
0017-6079
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether the receiver falls back during V.34 reception. If 'Prohibit' is selected, the receiver does not fall back.
5.1.1.10.7 Detailed Discussions of Bit 5
0017-6080
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether the transmitter falls beck during V.34 transmission. If 'Prohibit' is selected, teh transmitter does not fall back.
5.1.1.11 SSSW-SW30
5.1.1.11.1 List of Functions
0017-6081
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-13
Bit Function 1 0
0 Not used - -
1 Not used - -
2 Not used - -
3 Not used - -
4 Not used - -
5 New dial tone detection method Detect with the new Detect with the
method. existing method.
6 Not used - -
7 Not used - -
T-5-14
Bit Function 1 0
4 Yes No
5 not used - -
6 not used - -
7 not used - -
25
Chapter 5
Use it to specific whether to indicate the machine serial No. on the Counter Check screen, appearing when the Counter key is pressed.
If 'yes' is selected, the serial No. will be indicated.
If 'no' is selected, on the other hand, the serial No. will not be indicated.
5.1.1.12.4 Detailed Discussions of Bit 2
0017-6086
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether to switch the counter display type in effect in Japan and USA to the conventional or new type. Select "Yes" to display counters in the new type.
Select "No" to display counters in the conventional type.
T-5-15
Bit4 Bit3
Conventional type 0 0
New type 1 0 1
New type 2 1 0
5.1.1.13 SSSW-SW34
5.1.1.13.1 List of Functions
0017-6088
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-16
Bit Function 1 0
1 Switch the waste toner full Drum replacement required E019 displayed on an service
warning message displayed on an call
operator call
2 Not used - -
3 Not used - -
4 Not used - -
5 Not used - -
6 Not used - -
7 Not used - -
The default setting of this SSSW varies depending on the destination of the product.
Product for Japan: 00000000
Product for countries in Euro zone: 00000011
Products for other countries/regions: 00000001
5.1.1.13.2 Detailed Discussions of Bit 0
0017-6089
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
26
Chapter 5
Select whether to display the waste toner full warning as a drum replacement required message or as E019 displayed on an operator call. Select 1 to display a rum
replacement required message on an operator call. Select 0 to display E019 on an service call.
T-5-17
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##281, ##282, ##283, ##750, ##755, ##765, ##774, ##779, ##784, ##789
Any of the following error codes may be indicated at time of transmission because of the line condition:
##103, ##107, ##114, ##201, ##790, ##793
Any of the following error codes may be indicated at time of transmission because of the line condition:
##100, ##101, ##102, ##104, ##201, ##280, ##281, ##282, ##283, ##284, ##750, ##752, ##754, ##755, ##757, ##759, ##760, ##762, ##764, ##765,
##767, ##769, ##770, ##772, ##774, ##775, ##777, ##779, ##780, ##782, ##784, ##785, ##787, ##789
Any of the following error codes may be indicated at time of reception because of the line condition:
##103, ##106, ##107, ##201, ##793
Use it to set an upper limit to the modulation speed (baud rate) for the V.34 primary channel.
Use it to set an upper limit to the data transmission speed for the V.34 primary channel between 2.4K and 33.6K bps in increments of 2400 bps. (0: 2.4K to 13:
33.6K bps).
27
Chapter 5
T-5-18
5.1.3.2 <002: RTN transmission condition (1)><003: RTN transmission condition (2)><004: RTN transmission condition
(3)>
0017-6100
Use it to set RTN signal transmission conditions. Raise these parameters for more lenient conditions if errors occur frequently at time of reception because of trans-
mission of the RTN signal.
Memo:
Any of the following error codes may be indicated at time of reception because of RTN signal transmission
##0104, ##0107, ##0114, ##0201
RTN signal transmission condition (1) affects the ratio of error lines to the total number of lines per single page of received images.
RTN signal transmission condition (2) affects the standard value (*2) of burst errors (*1).
RTN signal condition (3) affects the number of errors not reaching the standard value of burst errors.
If any of these lines is detected while an image signal is being received, the RTN signal will be transmitted after receiving the protocol signal of the transmitting
party. Higher parameters restrict the transmission of the RTN signal.
Use it to set the length of the pause automatically entered between access code and ID code when the NCC (New Common Carrier) line is used for dialing.
Use it to set the length of the pause automatically entered between ID code and telephone number of the other party when the NCC (New Common Carrier) line is
used for dialing.
28
Chapter 5
Use it to set the time for identifying the line connection. Raise this parameter if errors occur frequently at time of communication because of the condition of the line.
Memo:
Any of the following error codes may be indicated because of the condition of the line
##0005, ##0018
The line condition identification time is between when the dial signal is transmitted and when the line condition is cut for the transmitting party, while it is between
when the DIS signal is transmitted and when the line is cut for the receiving party.
Set the T1 timer for the receiver (wait time after DIS transmission starts until a significant signal is received).
Set it so that the 1-line transmission time is longer for reception to prevent reception errors caused by a long data length per line (e.g., computer FAX).
Allows setting of the time from seizing the line till pseudo RBT is sent, when the Fax/ Tel switching function is operating.
5.1.3.9 <017: pseudo RBT signal pattern ON time length><018: pseudo RBT signal pattern OFF time length (short)><019:
pseudo RBT signal pattern OFF time length (long)>
0017-6109
Use it to set the pattern of the pseudo RBT signal transmitted at time of a fax/tel switchover.
5.1.3.10 <020: pseudo CI signal pattern ON time length><021: pseudo CI signal pattern OFF time length (short)><022:
pseudo CI signal pattern OFF time length (long)>
0017-6110
Use it to set the pseudo CI signal pattern transmitted at time of a fax/tel switchover.
Sets the signal detection time for the answering machine connection function operation. When the answering machine connection function is operating, if the func-
tion does not operate normally because the fax does not detect CNG signal sent from the line, raise this parameter to increase the signal detection time.
Use it to detect the time of detection after which command analysis is started after detecting V.21 low-speed command preambles continuously for a specific period
of time.
Use it to confirm the count type indicated on the Counter Check screen, which appears in response to a press on the Counter key.
When '0' is selected, count type will not be indicated.
No.56: Use it to indicate the type of software counter 1 of the control panel. The type of soft counter 1 cannot be changed.
No.57: Use it to change the type of soft counter 2* of the control panel to suit the needs of the user.
No.58: Use it to change the type of soft counter 3* of the control panel to suit the needs of the user.
No.59: Use it to change the type of soft counter 4* of the control panel to suit the needs of the user.
No.60: Use it to change the type of soft counter 5* of the control panel to suit the needs of the user.
No.61: Use it to change the type of soft counter 6* of the control panel to suit the needs of the user.
*:The default type settings of soft counter is different from models.
<Soft Counter Specifications>
The soft counters are classified a follows in terms of input numbers:
100s: total
29
Chapter 5
200s: copy
300s: print
400s: copy + print
500s: scan
700s: received file print
800s: report pint
900s: transmitted scan
MEMO:
To make a change so that B4 papers (for print) will be counted as large-size, use service mode: make the following selections, and change bit 0 to '1': #SSSW>SW33.
To make a change so that B4 papers (for scan) will be counted as large-size, use service mode: make the following selections, and change bit 2 to '1': #SSSW>SW33.
30
Chapter 5
31
Chapter 5
32
Chapter 5
<SCAN SW SSSW01>
T-5-19
Bit Function 1 0
0 Not used - -
1 Not used - -
2 Not used - -
3 Not used - -
6 Not used - -
7 Not used - -
026: Distance from the standby position of CIS to the 22 6-48 one unit=0.1mm
shading start point.
032: Horizontal scan start position adjustment 115 50-150 one unit=0.1mm
042: Horizontal scan start position adjustment 220 170-270 one unit=0.1mm
(scanning on ADF)
33
Chapter 5
213: XYZ correction value (X) of standard white plate 8273 1-9999
214: XYZ correction value (Y) of standard white plate 8737 1-9999
215: XYZ correction value (Z) of standard white plate 9427 1-9999
If any operation error occurs after changing the setting value, change the setting value to the original one.
This value is used when automatic scan position adjustment (TESTMODE>"2"SCAN TEST>"3"SHEET POS ADJ) fails.
5.1.4.4 <026:Distance from the standby position of CIS to the shading start point>
0017-6119
Normally, do not change the setting value. If any operation error occurs after changing the setting value, change the setting value to the original one.
Adjust the position at which vertical scanning of a book starts. The larger the adjustment value, the narrower the left-side margin of the image becomes.
34
Chapter 5
Adjust the position at which horizontal scanning of a book starts. The larger the adjustment value, the narrower the top margin in the image becomes.
Correct the magnification of vertical scanning of a book. The larger the adjustment value, the more the image stretches in the vertical scanning direction.
Though no market adjustment work needs to be carried out, enter factory defaults at image processor PCB replacement.
5.1.4.9 <041: Vertical scan start position adjustment (when scanning on a document fed from ADF)>
0017-6124
Adjust the position at which vertical scanning of a document fed from the ADF starts. The larger the adjustment value, the narrower the left-side margin of the
image becomes.
5.1.4.10 <042: Horizontal scan start position adjustment (when scanning on a document fed from ADF)>
0017-6125
Adjust the position at which horizontal scanning of a document fed from the ADF starts. The larger the adjustment value, the narrower the top margin of the image
becomes.
Adjust the position at which horizontal scanning of a document being copied ends (when scanning on a document fed from ADF). The larger the adjustment value,
the narrower the bottom margin of the image becomes.
5.1.4.15 <047: Vertical scan magnification correction (when scanning on a document fed from ADF)>
0017-6130
Correct the magnification of vertical scanning of a document fed from the ADF. The larger the adjustment value, the more the image stretches in the vertical scan-
ning direction.
5.1.4.16 <048: Horizontal scan magnification correction (when scanning on a document fed from ADF)>
0017-6131
Correct the magnification of horizontal scanning of a document fed from the ADF. The smaller the adjustment value, the more the image stretches in the horizontal
scanning direction.
This menu is used to adjust the ADF feed motor speed. If you changed the adjustment value in this mode, the adjustment value selected for SCAN NUMERIC>54
must also be incremented/decremented by the same amount.
Set to use special standard-sized paper that is not otherwise identifiable to the ADF (because it is misidentified as "LEGAL").
0: LEGAL
1: FOOLSCAP
2: M_OFFICIO
3: A_FOOLSCAP
4: FOLIO
5: G_LEGAL
6: A_OFFICIO
7: B_OFFICIO
35
Chapter 5
Set to use special standard-sized paper that is not otherwise identifiable to the ADF (because it is misidentified as "LTR").
0: LTR
1: G_LTR
2: A_LTR
Set to use special standard-sized paper that is not otherwise identifiable to the ADF (because it is misidentified as "LTRR").
0: LTR_R
1: FOOLSCAP
2: OFFICIO
3: E_OFFICIO
4: G_LTR_R
5: A_LTR_R
This is market-related measures taken to improve shadow images generated by a thick original such as a book or a folded or wrinkled original. When taking the
measures, assign the same values for R, G, and B. After changing the values, be sure to turn off the power and turn it on again.
This is market-related measures taken to improve shadow images generated by a thick original such as a book or a folded or wrinkled original. When taking the
measures, assign the same values for R, G, and B. After changing the values, be sure to turn off the power and turn it on again.
This is market-related measures taken to improve shadow images generated by a thick original such as a book or a folded or wrinkled original. When taking the
measures, assign the same values for R, G, and B. After changing the values, be sure to turn off the power and turn it on again.
5.1.4.23 <213: XYZ correction value (X) of standard white plate> (if equipped with SEND functions))
0017-6138
If you replaced the image processor PCB, enter values indicated on the service label. If you have replaced the document glass, enter values indicated on the new
document glass and write the values on the service label.
820686679349
correcton correcton
va l u e ( X ) correcton va l u e ( Z )
va l u e ( Y )
F-5-2
5.1.4.24 <214: XYZ correction value (Y) of standard white plate> (if equipped with SEND functions)
0017-6139
If you replaced the image processor PCB, enter values indicated on the service label. If you have replaced the document glass, enter values indicated on the new
document glass and write the values on the service label.
820686679349
correcton correcton
va l u e ( X ) correcton va l u e ( Z )
va l u e ( Y )
F-5-3
5.1.4.25 <215: XYZ correction value (Z) of standard white plate> (if equipped with SEND functions)
0017-6140
If you replaced the image processor PCB, enter values indicated on the service label. If you have replaced the document glass, enter values indicated on the new
document glass and write the values on the service label.
36
Chapter 5
820686679349
correcton correcton
va l u e ( X ) correcton va l u e ( Z )
va l u e ( Y )
F-5-4
List of Functions
0017-6141
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-20
Bit Function 1 0
0 not used - -
1 not used - -
2 not used - -
3 not used - -
4 not used - -
5 not used - -
6 not used - -
T-5-21
place: if B4 recording paper and A4 recording paper are set and an A4 extra-long image
(*) is received, printing will be on the B4 recording paper.
do not place: if B5 horizontal recording paper and A4 recording paper are set and a B4 image is
received, printing will be by division and on B5 horizontal recording paper.
*: Image B4 or shorter and that cannot be printed by division and on A4 recording paper.
5.1.5.1.2 SSSW-SW14
List of Functions
0017-6143
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-22
Bit Function 1 0
37
Chapter 5
Bit Function 1 0
7 Not used - -
Select whether to enable or disable developing assembly idling mode. Select "Enable" to drive the main motor for a specified period of time to apply idling and
developing bias (AC + DC) to prevent the thinning of the image density when the unit is installed or the developing unit is replaced in a low-temperature, low-
humidity region. This mode works only on a new developing assembly and before a toner cartridge is loaded.
Detailed Discussions of Bit 2
0017-6147
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether to enable or disable black belt addition mode. If the user uses paper that causes fixed toner on paper to be fused and adhered to drum, selecting
"Yes" will clean the drum by forming a black band on the drum surface during the reverse rotation which is performed after printing on 50 sheets.
Implementation of this mode could result in a drum life falling short of its life expectancy.
Select whether to enable or disable flicker reduction mode. Select "Enable" and enter a count to modify fusing temperature control to cancel fluorescent flicking
during printing.
Select whether to enable or disable silent mode. Select "Enable" to modify the registration loop amount and thus reduce noises or squeaks the registration rollers
produce after picking paper from the individual paper inlets.
Detailed Discussions of Bit 6
0017-6151
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether to enable or disable noise reduction mode during terminal temperature rises. Select "Enable" to start slowdown at a temperature lower than normal
when printing on smaller-sized paper than B4. Slowdown control thus enabled prevents the thermal degradation of the fusing film grease, assuring smooth sliding
among the fixing film, heater and film guide to cut squeaks.
5.1.5.1.3 SSSW-SW15
List of Functions
0017-6152
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-23
Bit Function 1 0
38
Chapter 5
Bit Function 1 0
2 Inhibit tray full indication while the stapled document Enable Disable
count is exceeded
4 Not used - -
5 Not used - -
6 Not used - -
7 Not used - -
Select whether to inhibit automatic delivery tray replacement while running jobs with an inner two-way tray mounted in position. Select "Enable" to inhibit auto-
matic tray replacement.
Detailed Discussions of Bit 1
0017-6154
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether to halt stapling job when a finisher installed has run out of staples. Select "Enable" to halt staple jobs when the finisher has run out of staples.
Detailed Discussions of Bit 2
0017-6155
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether to display a tray full message when the maximum allowable stapled document count is exceeded with a finisher installed. Select "Enable" not to
display the message.
Detailed Discussions of Bit 3
0017-8532
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Select whether split recording is to be enabled when text data such as a header and body text is recorded. Selecting "Set" may split text data when a small paper size
such as A5 is selected. In this case, a page may be split in the middle of a character string.
5.1.5.1.4 SSSW-SW18
List of Functions
0017-8533
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
T-5-24
Bit Function 1 0
3 Not used - -
4 Not used - -
5 Not used - -
6 Not used - -
7 Not used - -
If there is no progress after shifting the target figure of the temperature adjustment using "Temperature Adjustment UP/DOWN Mode", # PRINTER> Numeric>
39
Chapter 5
Parameter 62, 63, cancel the inner limit of the fixed temperature adjustment.
To cancel the inner limit of the fixed temperature adjustment, select "Setting".
Detailed Discussions of Bit 1
0017-8535
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
If there is no progress after shifting the target figure of the temperature adjustment using "Temperature Adjustment UP/DOWN Mode", # PRINTER> Numeric>
Parameter 62, 63, cancel the 2nd face of the duplex inner limit of the fixed temperature adjustment.
Select "Setting" to cancel the 2nd face of the duplex inner limit of the fixed temperature adjustment.
Detailed Discussions of Bit 2
0017-8536
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
When selecting the post cards, besides the 'Reply post card', 'Post card', and the 'Four face post card', 'Thin post card' could be selected. Select 'Setting' and 'Thin
post card' would be selected.
5.1.5.2 Numeric Parameter Settings (NUMERIC Param.)
5.1.5.2.1 List of Functions
0017-6156
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
40
Chapter 5
Adjust the top registration margin of paper picked from cassettes. The larger the adjustment value, the wider the top margin of the image becomes.
5.1.5.2.4 <033: Top registration adjustment (duplex unit)>
0017-6159
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the top registration margin of paper picked from a duplex unit. The larger the adjustment value, the wider the top margin of the image becomes.
5.1.5.2.5 <034: Left-end registration adjustment (manual feed tray)>
0017-6160
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the left-end registration margin of paper picked from a manual feed tray. The larger the adjustment value, the wider the left-end margin of the image be-
comes.
5.1.5.2.6 <035: Left-end registration adjustment (cassette 1)>
0017-6162
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the left-end registration margin of paper picked from cassette 1. The larger the adjustment value, the wider the left-end margin of the image becomes.
5.1.5.2.7 <036: Left-end registration adjustment (cassette 2)>
0017-6163
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the left-end registration margin of paper picked from cassette 2. The larger the adjustment value, the wider the left-end margin of the image becomes.
5.1.5.2.8 <037: Left-end registration adjustment (cassette 3)>
0017-6164
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the left-end registration margin of paper picked from cassette 3. The larger the adjustment value, the wider the left-end margin of the image becomes.
5.1.5.2.9 <038: Left-end registration adjustment (cassette 4)>
0017-6165
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the left-end registration margin of paper picked from cassette 4. The larger the adjustment value, the wider the left-end margin of the image becomes.
5.1.5.2.10 <039: Left-end registration adjustment (duplex unit)>
0017-6166
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the left-end registration margin of paper picked from a duplex unit. The larger the adjustment value, the wider the left-end margin of the image becomes.
5.1.5.2.11 <040: Target fixing temperature adjustment (manual feed tray)>
0017-6167
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Lower the fixing temperature from the target temperature setting to reduce the chances of fixing offsets and curled or stuck delivered sheets occurring with paper
picked from a manual feed tray.
5.1.5.2.12 <045: Fixing film speed change (manual feed tray)>
0017-6172
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Change the fixing film speed to reduce the chances of streaks appearing in the trailing edge of images caused by shocks from the fixing roller out of position while
picking paper from a manual feed tray.
5.1.5.2.13 <046: Fixing film speed change (cassette)>
0017-6173
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Change the fixing film speed to reduce the chances of streaks appearing in the trailing edge of images caused by shocks from the fixing roller out of position while
picking paper from a cassette.
5.1.5.2.14 <053: Margin adjustment at the leading edge of the copy>
0017-6168
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the margin at the leading edge of the copy. Increasing the value makes the margin at the leading edge larger.
5.1.5.2.15 <054: Margin adjustment at the trailing edge of the copy>
0017-6169
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the margin at the trailing edge of the copy. Increasing the value makes the margin at the trailing edge larger.
5.1.5.2.16 <055: Margin adjustment at the right edge of the copy>
0017-6170
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Adjust the margin at the right edge of the copy. Increasing the value makes the margin at the right edge larger.
41
Chapter 5
Adjust the margin at the left edge of the copy. Increasing the value makes the margin at the left edge larger.
5.1.5.2.18 <058:: Adjustment of the registration loop volume (Manual feed tray)>
0017-8644
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
If there is a registration loop noise and abrasion while feeding the paper from the manual feed tray, registration loop noise and abrasion could be reduced by adjusting
the volume of the registration loop. By making the value larger, loop volume will become bigger.
5.1.5.2.19 <059:Adjustment of the registration loop volume. (Cassette)>
0017-8645
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
If there is a registration loop noise and abrasion while feeding the paper from the cassette, registration loop noise and abrasion could be reduced by adjusting the
volume of the registration loop. By making the value larger, loop volume will become bigger.
5.1.5.2.20 <060:Adjustment of the registration loop volume (Option cassette)>
0017-8646
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
If there is a registration loop noise and abrasion while feeding the paper from the option cassette, registration loop noise and abrasion could be reduced by adjusting
the volume of the registration loop. By making the value larger, loop volume will become bigger.
5.1.5.2.21 <061:Adjustment of the registration loop volume. (Duplex unit)>
0017-8648
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
If there is a registration loop noise and abrasion while feeding the paper from the duplex unit, registration loop noise and abrasion could be reduced by adjusting
the volume of the registration loop. By making the value larger, loop volume will become bigger.
5.1.5.2.22 <062:Temperature adjustment UP/DOWN mode. (For plain paper)>
0017-8649
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
For plain paper relation, the volume of the temperature adjustment offset could be changed by 5 deg C at a time to aim the fixed temperature.
For plain paper relation : Normal, Normal Lo, rough paper Lo, thin post card, and OHP mode.
0 to 6: -35 to -5 deg C (1unit=5deg C)
7: 0 deg C
8 to 14: +5 to +35 deg C (1unit=5deg C)
5.1.5.2.23 <063:Temperature adjustment UP/DOWN mode. (For rough paper)>
0017-8650
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
For rough paper relation, the volume of the temperature adjustment offset could be changed by 5 deg C at a time to aim the fixed temperature.
For rough paper relation: rough paper, super rough paper, super rough paper H, post card, post card H, and envelope mode.
0 to 6: -35 to -5 deg C (1unit=5deg C)
7: 0 deg C
8 to 14: +5 to +35 deg C (1unit=5deg C)
5.1.5.2.24 <064:Mode for preventing the temperature rise of the end >
0017-8651
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
Set when the fixed film squeaks. Lower the target fixing temperatue and extend sheet-to-sheet time except A4/A3/11X17/LTR size.
0: Normal
1 to 5: Mode for responding film squeak. (reference to the table below)
T-5-25
42
Chapter 5
There is a possibility that when using the "Reducing mode", the life of the drum will not meet the specified pieces.
Changing to high-pressure environment by using the temperature/ humidity sensor. But when there is an image trouble at the point of changing the environment,
fix the temperature and the humidity and do not allow the change of the high-pressure output.
0: Normal
1: Fixed environment of LL. (Temperature of 10 deg C and humidity of 10%)
2. Fixed environment of NN. (Temperature of 20 deg C and humidity of 50%)
3. Fixed environment of HH. (Temperature of 30 deg C and humidity of 80%)
5.1.5.3 Setting of Cassette (CST)
5.1.5.3.1 Special Standard-sized Paper Compatibility
0017-6174
iR2022i / iR2025 / iR2030 / iR2018 / iR2022 / iR2018i
With a special paper compatibility kit (cassette size adjuster) installed, set the cassette paper size lever to paper size groups U1 to U3 to set the paper sizes listed
below.
Selecting the service mode "#NETWORK>#CERTIFICATE>#CA-CERTIFICATE" enables confirmation of the contents of the installed CA certificate.
Bit Function 1 0
0 Not used - -
1 Not used - -
2 Not used - -
3 Not used - -
4 Not used - -
5 Not used - -
43
Chapter 5
Bit Function 1 0
7 Not used - -
Bit 6 details
Select whether to enable the host machine to work as a USB storage device or not. If the host machine is plugged into a PC with this setting enabled, it allows user
registration data (user data and telephone registration data) to be imported and exported to and from the PC, except for the data embedded in the department man-
agement information and user management IDs in the system management information.
Item Explanation
CONTROL Set the PDL printer output control where the control card I/F (CC-V) is supported.
0: Enable printing without a card mounted.
1: Enable printing with a card mounted in position.
5.1.9.1 Outline
0017-8537
(1) Access to LMS from the below URL and follow the direction on the screen to acquire the license key.
URL for LMS
http://www.canon.com/lms/license/
MEMO:
To acquire the license key, 16 digit figures on the license access number certificate and the device serial number (for example: ABC01234), which the license is
going to be installed is necessary.
Device serial number will indicate on "Serial Number" when pressing the counter confirmation key on the main machine.
(2) Copy the license key of 24 digit figures, which is indicated on the WEB browser to the designated column on license access number certificate.
Reconfirm that there is no miss-copy of the 24 digit figures. Explain to the user that license access number certificate should be kept with care.
(3) Input the copy of the license key from; user mode > system management setting> license registration and press enter. The license key will be registered and
function will activate.
If the function do not activate, error message will indicate. Confirm the points below due to contents of the error message.
44
Chapter 5
(5) Registered license will be active when after the power supply of the main device switch has been cut off once and put on again. Once the license starts properly,
press counter confirmation key then press device configuration and confirm that in the option column that the relevant kit has been indicated.
Confirmation could be made whether the license option is active or not in the SOFT-ID PRM item by outputting the SPEC REPORT from the service mode.
Output method:
Select '# REPORT' from service mode.
Select '# REPORT OUTPUT'.
Select '# REPORT OUTPUT SPEC LIST' and press 'OK'.
Check the SOFT-ID RPM column from the SPEC REPORT output. License is active on the items which indicates 'ON/ON'.
Related items:
BIT 00: BDL-IMAGE(1200) -> CARPS2
BIT 05: BW-SEND -> SEND
BIT 06: CL-SEND -> SEND
BIT 09: BDL-IMAGE( 600) -> CARPS2
Operation procedures
(1) Go into the service mode and indicate the below mentioned service mode. (Key operation to go into the service mode is to be pressed one at a time. Orders are
*, 2, 8, *).
After going into the service mode, use the arrow on the both sides of the touch panel and press 'OK' if the decision is made.
(2) Indicate '#LMS'.
(3) Press 'OK' and indicate '#LMS INACTIVE'.
(4) Indicate 'BDL-IMAGE (CARPS 2 for Japanese market) or 'SEND'.
(5) Press 'OK'.
(6) Press '2' from the numeric keypad and press 'OK'.
#SEND
OK
F-5-5
1.Take a note of the license transmit number which will be indicated with 24 digits.
2.The indicated number is just for this operation and it would not be saved.
3.If the power is switched off, the indicated number will disappear and if the note of the number has not been taken, transmission of the license will be impossible.
4.Even pressing the reset key to clear the indication, there will be no recovery of the number.
F-5-6
(7) Switch the power supply OFF/ON of the main machine.
45
Chapter 5
Reference:
At procedure (4) when indicating the license option, it indicates ' 001 1'. The last digit '1' shows that the license is active.
After transmitting the license the last digit will change to '2', which means that the license has been transmitted.
If the option is standard equipped, the last digit will indicate '3', which means that the license could not be transmitted.
(8) Contact the dealer and inform the function inactive certificate key, serial number of the transmission origin device, and serial number of new transmiting device,
which is necessary to transmit the license.
Upon given information above, new license key will be issued, which the license could be registered to the new transmitting device.
(9) Register the new license key to the transmitted device and confirm that the function is active.
Item Description
E-RDS SWITCH e-RDS OFF/ON setting (0:OFF / 1:ON)When used (ON), the counter information and error information are sent
to UGW.Default: 0 (OFF)
RGW-ADDRESS URL of UGWDefault: URL of actual UGWCharacter string length: 129 bytes (including NULL, one-byte codes
only)
COM-TEST Execution of communication test An attempt is made to connect to UGW, judges whether connection is
successful, and displays "COM-TEST OK" or "COMTEST NG" as the judgment result.
COM-LOG Details of communication test resultThe log of errors in communication with UGW is displayed. The error
information includes the error occurrence time, error code, and details of the error.Maximum log count: 5Error
information length: Max. 128 characters (excluding NULL)
5.1.11.1 Counters
0017-6180
46
Chapter 5
T-5-29
M-PU-RL Manual feed tray pickup roller paper pass count 150,000
M-SP-PD Manual feed tray separation pad paper pass count 150,000
The table below lists the kinds of reports that are supported.
Item Explanation
SERVICE DATA LIST Service mode service soft switch output (SSSW, MENU, NUMERIC Param., SPECIAL, NCU, SCAN, PRINT, SYSTEM, ROM,
start date)
SYSTEM DATA LIST Service mode service soft switch output (SSSW, MENU, NUMERIC Param., SPECIAL, NCU, SCAN, PRINT, SYSTEM, ROM,
start date)
System dump list output
SYSTEM DUMP LIST Transmission count, reception count, record chart count, error count and other outputs
SPEC LIST Type setting, print speed, memory size, ROM indication, adjustment data and other outputs
SERVICE LABEL Output of an entry format for the service label affixed to the rear cover as shipped
ERDS COM LOG LIST Output of communication error log information related to e-RDS
Use it to check the settings associated with the service soft switch and service parameters.
47
Chapter 5
F-5-7
[1]
[3]
[2]
[3]
[4]
[5]
[6]
[7]
[8]
[9]
F-5-8
*1: TX, number of total pages transmission.
*2: Total number of pages transmitted/received according to original size.
*3: RX, number of total pages reception.
*4: Total number of pages transmitted and received for each modem speed
*5: Total number of pages transmitted/received in connection with different modem speeds (Standard, Fine, Super Fine, Ultra Fine).
*6: Total number of pages transmitted and received for each coding method
48
Chapter 5
T-5-30
Indication
sample
##280 1 7 3 0 0
!
" !
# #$ !
%
&'()
!
&*+ ,#$ -
# !
"
% !
%
%
. " !
.
!
" !
# #$ !
%
&'()
!
&*+ ,#$ -
# !
"
% !
%
%
. " !
.
!
!
" !
# #$ !
%
&'()
!
&*+ ,#$ -
# !
"
% !
%
%
F-5-9
*1: service error code.
*2: START TIME, date and time (in 24-hr notation).
*3: OTHER PARTY, telephone number sent by the other party.
*4: MAKER CODE, manufacturer code.
*5: MACHINE CODE, model code.
*6: bit 1 through bit 96 of DIS, DCS, or DTC that has been received.
*7: bit 1 through bit 96 of DIS, DCS, or DTC that has been transmitted.
*8: RX, procedural signal received; TX, procedural signal transmitted.
49
Chapter 5
***************************************
*** JAM/ERR LOG REPORT ***
***************************************
[1] [2] [3] [4] [5] [6] [7] [8] [9] [10]
JAM
01 04/12 12:17 20:03 4 1 0012 000026 1 A4
ERR
01 04/12 12:17 15:36 3 0010 0000 000691
F-5-10
50
Chapter 5
51
Chapter 5
[1] *****************************
[2] *** SPEC REPORT ***
*****************************
[3]
TYPE _____ JAPAN
LBP SPEED _____ 25cpm
TOTAL MEMORY _____ 256MB
MAIN _____ WLaa-08-01
_____
[4] OPTION
_____
WLaa-08-01
BOOT WLaa-08-01
LANG _____ WLaa-08-01
LANG LIBRARY (QVGA) _____ 000C0000
LANG FILE (QVGA)
ENGLISH _____ 000C0000
JAPANESE _____ 000C0000
BULGARIAN _____ 000C0000
CATALAN _____ 000C0000
CZECH _____ 000C0000
DANISH _____ 000C0000
SPANISH _____ 000C0000
ESTONIAN _____ 000C0000
FINNISH _____ 000C0000
FRENCH _____ 000C0000
GERMAN _____ 000C0000
GREEK _____ 000C0000
CROATIAN _____ 000C0000
HUNGARIAN _____ 000C0000
ITALIAN _____ 000C0000
DUTCH _____ 000C0000
NORWEGIAN _____ 000C0000
POLISH _____ 000C0000
PORTUGUESE _____ 000C0000
ROMANIAN _____ 000C0000
RUSSIAN _____ 000C0000
SLOVAK _____ 000C0000
SLOVENE _____ 000C0000
SWEDISH _____ 000C0000
TURKISH _____ 000C0000
ECONT _____ 0309
OPT-CAS 1 _____ 0000
OPT-CAS 2 _____ 0000
OPT-CAS 3 _____ 0000
OPT-DUP _____ 0000
OPT-FIN _____ 0000
ACTIBAT FUNCTION
BDL-IMAGE (1200) _____ OFF
[5] FAX _____ ON
NETWORK _____ ON
PCL _____ ON
PC-SCAN _____ ON
BW-SEND _____ OFF
CL-SEND _____ OFF
PAF _____ OFF
BDL-IMAGE (600) _____ OFF
E-RDS _____ OFF
BAR-DIMM _____ OFF
SOFT-ID PRM
TYPE _____ 0 : NONE
[6] OPTION/ENABLE SW
BIT 00: BDL-IMAGE (1200) _____ ON / OFF
BIT 01: FAX _____ ON / OFF
BIT 02: NETWORK _____ ON / OFF
BIT 03: PCL _____ ON / OFF
BIT 04: PC-SCAN _____ OFF / OFF
F-5-11
52
Chapter 5
F-5-12
[1] Type setting
[2] Print speed
[3] Memory size
[4] ROM version (MAIN/BOOT/LANG*1(language liblary/language file version)ECONT/option cassette/duplex unit/finisher)
[5] Activation function ON/OFF
[6] Soft ID information
[7] Total counter (TOTAL/COPY/FAX/PDL/REPORT record counts)
[8] Adjustment data (factory scan/record adjustment values)
[9] Option ROM availability
[10] USB memory availability
[11] No. 1/No. 2 paper full sensor sensor availability
[12] USB serial number
[13] MAC address
[14] Backup battery availability
[15] ROM version (Reader controller PCB)
[16] output the number of histories (communication history, copy/print/report/JOB history of the reception print, jam history, E code history, humidity log)
*1: only for the touch panel model
53
Chapter 5
Enter the value given in the service label affixed to the rear cover when it has been replaced with a new one.
[1] ***********************************************
*** ENVIROMENTT LOG REPORT ***
***********************************************
SERIAL NO XXXxxxx
ENVIROMENT
No. DATE TIME D+Temp E+Hum F+Temp F+Temp
001 0616 0930 D030 E026 F180 F180
002 0616 1030 D028 E025 F181 F181
F-5-14
History description
Item Explanation
[1] Serial number Serial number of this machine
[2] Number The larger the number of a enviroment log data, the more recently it has occurred.
[3] Date Data acquisition day
[4] Time Data acquisition time
[5] Temperature (deg)
[6] Humidity (%)
[7] Fixing roller temperature 1
(deg)
[8] Fixing roller temperature 2
(deg)
54
Chapter 5
5.1.13.1 Download
0017-6182
The following parts of this unit can be upgraded by executing download mode using the service support tool (SST) (for more information, see the "Upgrading"
section):
Main unit
- Flash ROM (system + boot) mounted on the image processor PCB
Accessory
- ROM mounted on the finisher controller PCB
- ROM mounted on the PCL board
5.1.14.1 Clear
0017-6183
SERVICE DATA Clears the system dump list, except for counters and clear dates.
COUNTER Clears the maintenance counter, parts counter and mode-specific counters.
Initializes the counter (numerator) in the system dump list.
TYPE Initializes user data and service data to suit specified destination settings.
CARD Clears department management information held in the controller before the card
reader is demounted.
FORMAT*1 USB MEMORY Format the USB memory. (This mode is used when the USB memory error is damaged
and E744 occurs.)
LICENSE Not used
DRIVE
CA-KEY Initializes an installed CA certification.
ERDS-DAT The settings related to e-RDS are cleared to the factory settings.
ALL Clears user and service data (except for some scan parameters and print parameters),
and the counter setting/registration data in the system dump list, except for the print
count.
An error code is displayed when a service error has occurred. The E code is displayed in the upper step, and the detail code is displayed the bottom step.
55
Chapter 5
The table below lists the items of ROM display mode that are supported.
T-5-31
Item Explanation
MAIN Displays the version number of the ROM (SYSTEM) mounted on the image
processor PCB.
MAIN2 Displays the version of the ROM (BOOT) mounted on the image processor
PCB.
ECONT Displays the version number of the ROM mounted on the DC controller PCB.
5.1.17.1 Outline
0017-6193
Test mode must be executed by keeping track the flow of menu items appearing on the LCD. Menu items in test mode are organized into seven blocks as described
below. Numerals enclosed in parentheses denote a numeric keypad key to be pressed each.
1. D-RAM test ((1) D-RAM)
Checks to see if data can be correctly written to and read from D-RAM.
56
Chapter 5
57
Chapter 5
iR2022i / iR2018i
58
Chapter 5
59
Chapter 5
F-5-15
60
Chapter 5
Press the numeric keypad key 2 on the test mode menu to select the CCD test.
Press numeric keypad keys 1, 3 and 4 during the CCD test to carry out the individual tests described below.
Use it to make sure that the print Use it to make sure that the print
pattern does not have white lines pattern does not have contraction/
or uneven image. elongation of an image or dirt/black
line.s
F-5-16
1 Relay test Use it to turn on/off a selected relay to execute a switch-over test
2 Frequency test The modem sends tonal signals from the modular jack and the speaker.
4 G3 signal transmission test The modem sends G3 signals from the modular jack and the speaker.
5 DTMF signal reception test Use it to generate the DTMF signal coming from the modem using the
telephone line terminal and the speaker.
6 Tonal signal reception test Use it to monitor a specific frequency and the DTMF signal received from
the telephone line terminal by causing them to be indicated on the LCD (i.e.,
the presence/absence as detected). The reception signal is generated by the
speaker.
8 V.34 G3 signal transmission test The modem sends V.34 G3 signals from the modular jack and the speaker.
Relay Test
61
Chapter 5
Press '1'or '2' on the keypad on the Modem test menu to select relay test mode. Use the keypad to operate the various relays of the NCU. '2' on the keypad is used
for 230V machine.
Numeric keypad key 1
The input key and relay are shown below:
[1] [2]
F-5-17
Numeric keypad key 2
The input key and relay are shown below:
[1] [2]
F-5-18
The touch panel (LCD) is turned on or off in relation to the transmission of the relay operation signal as is operated on the keypad; for this reason, you cannot use
the touch panel (LCD) to check a fault on a single relay.
Frequency Test
A press on '2' on the keypad from the MODEM test menu selects the frequency test.
In this test, signals of the following frequencies from the modem are transmitted using the telephone line terminal and the speaker. To select a different frequency,
use the keypad.
Keypad Frequency
1 462Hz
2 1100Hz
3 1300Hz
4 1500Hz
5 1650Hz
6 1850Hz
7 2100Hz
MEMO:
The frequency and the output level of individual frequencies are in keeping with the output level set in service mode.
0 300bps
1 2400bps
2 4800bps
3 7200bps
4 9600bps
5 TC7200bps
6 TC9600bps
7 12000bps
8 14400bps
62
Chapter 5
MEMO:
The output level of individual signals is in keeping with the setting made in service mode.
MEMO:
The output level of individual signals is in keeping with the setting made in service mode.
MODEM TEST
OFF OFF OFF
MODEM TEST
OFF OFF OFF 5
The received DTMF signals are indicated starting
from the right using the 2nd character of the display.
F-5-19
V.34 G3 Signal Transmission Test
A press on '8' on the keypad from the MODEM test menu selectes the V.34 G3 signal transmission test. The V.34 G3 signals below are sent from the modem using
the modular jack and the speaker by pressing the start key. The Baud rate can be changed with the keypad, and the Speed can be changed with the left/right arrow
key.
0 3429baud
1 3200baud
2 3000baud
3 2800baud
4 2743baud
5 2400baud
2400bps
4800bps
7200bps
9600bps
< 12000bps
14400bps
16800bps
19200bps
21600bps
> 24000bps
26400bps
28800bps
31200bps
33600bps
63
Chapter 5
7 Not used
9 Line signal reception test NCU board signal sensor and frequency counter operation test
64
Chapter 5
6-3:SENOR
[1] - [6]
Press numeric keypad key 1. Press numeric keypad key 0. Press numeric keypad key 0.
Select a sensor mode. CAS:Cassette 1 paper sensor (SR204): 0/Document presence, 1/Document absence
0: NORMAL REG:Registration sensor (SR209): 0/Document presence, 1/Document absence
Indications change from 0 Press numeric keypad key 1. DEL 0 0:
to 1 as the sensors turn on. Fixing delivery sensor (SR202): 1/ Document presence, 0/ Document absence
Indications change from 1 SENSOR LATCH No.1 delivery sensor (SR203): 1/ Document presence, 0/ Document absence
to 0 as the sensors turn off. [0] - [2] MULTI:Manual paper sensor (SR208): 0/Document presence, 1/Document absence
1: LATCH
Indications change from 0
to 1 as the sensors turn on.
Indications do not change back Press numeric keypad key 1.
from 1 to 0 once the sensors turn
on from the off state. TONER 0 FULL 0
2ND-DEL 0 0
OP1 0 0 OP2 0 0
OP3 0 0 PATH 0 0
OP1 0 0:
Cassette 2 retry sensor (SR6): 0/Document presence, 1/Document absenc
Cassette 2 paper sensor (SR5): 0/Document presence, 1/Document absence
OP2 0 0:
Cassette 3 retry sensor (SR6): 0/Document presence, 1/Document absence
Cassette 3 paper sensor (SR5): 0/Document presence, 1/Document absence
OP3 0 0:
Cassette 4 retry sensor (SR6): 0/Document presence, 1/Document absence
Cassette 4 paper sensor (SR5): 0/Document presence, 1/Document absence
PATH 0 0:
Duplex paper sensor 1 (SR1002): 0/Document presence, 1/Document absence
Duplex paper sensor 2 (SR1002): 0/Document presence, 1/Document absence
F-5-20
65
Chapter 5
BSCT on BDOC[A3 ]
BDSS3-0 [of of of of]
BCST: Document platen cover sensor (SR402): On/Cover open, Of/Cover closed
BDOC: Document size: Paper size indicated in a mix of document size sensors
BDSS3-0 [of of of of]:
Document size sensor (SR404 or SR405): On/Document presence, Of/Document absence
Document size sensor (SR403): On/Document presence, Of/Document absence
Document size sensor (SR401): On/Document presence, Of/Document absence
Document size sensor (SR402): On/Document presence, Of/Document absence
Press numeric
keypad key 6. [1]
[1] Card reader and card availability indication [4] Can status
Card available: Eight-digit card ID OK: Normal scan
No card: Card None ERR: Scan error
No card reader available: NCR None NG: Nonstandard error
(No indication): No card
[2] Card type and card reader status indication [5] Equipment status
DPT: Department card IN: Initialization in progress
PRC: Unit pricing card RDY: Ready
MAX: Upper limit setting card
ERS: Erased card [6] Card reader version indication
SRV: Service card Four-digit number
(No indication): No card
66
Chapter 5
6-6: SPEAKER
FREQ [1] VOL [2]
SPEAKER SPEAKER
FREQ TEST VOL[*] :MIN [#]:MAX
F-5-22
Lamp test (6-8: LAMP TEST)
Press numeric keypad key 8 on the FACULTY menu to select the scan lamp illumination mode. The test checks to see if the scan lamp is on or not.
Numeric keypad key 1 selects LAMP TEST ALL. Press the start key to turn on all scan lamps. LAMP TEST AGC is not used.
Line signal reception test (6-9 LINE DETECT)
Press numeric keypad key 9 on the FACULTY menu to select the line signal reception test. In this test, verify the successful operations of the NCU signal sensor
and the frequency counter. Menu 1 detects the CI state, while menu 3 detects the CNG signal.
Test menu 1
Press numeric keypad key 1 on the LINE DETECT menu to select test menu 1. When CI is detected on the telephone line connection terminal, the touch
panel (LCD) display changes from OFF to ON, indicating the received frequency. The touch panel (LCD) also displays the on-hook or off-hook state of an
external telephone set as detected. The touch panel (LCD) displays, from left to right, CI, CI frequency, hook port and FC with indications of 1:ON and
0:OFF.
Test menu 2
Press numeric keypad key 2 on the LINE DETECT menu to select test menu 2. When the CNG signal is detected on the telephone line connection terminal,
the touch panel (LCD) display changes from OFF to ON, indicating the received frequency. The touch panel (LCD) displays the status of CML, CNG and
FED detection, from left to right, with ON/OFF indications. Numeric keypad key 2 turns on the CML relay to detect CNG.
Test menu 3
Press numeric keypad key 3 on the LINE DETECT menu to select test menu 3. When the CNG signal is detected on the telephone line connection terminal,
the touch panel (LCD) display changes from OFF to ON, indicating the received frequency. The touch panel (LCD) displays the status of CML, CNG and
FED detection, from left to right, with ON/OFF indications. Numeric keypad key 3 turns off the CML relay to detect CNG.
67
Chapter 6
6.1 Clutch/Solenoid
<Reader Unit>
The reader unit has no clutch/solenoid.
<Printer Unit>
CL203
CL201
SL201
SL202
CL202
F-6-1
6.2 Motor
69
Chapter 6
<Reader Unit>
M401
F-6-2
<Printer Unit>
M201
M203
M204
F-6-3
70
Chapter 6
6.3 Fan
<Reader Unit>
The reader unit has no fan.
<Printer Unit>
T-6-1
FM1
F-6-4
6.4 Sensor
71
Chapter 6
<Reader Unit>
T-6-2
SR402 Copyboard cover open/closed sensor (rear) Detects opening/closing of the copyboard cover.
SR403 Copyboard cover open/closed sensor (front) Detects opening/closing of the copyboard cover.
T-6-3
SR407 SR408
SR406
SR403 SR404/SR409
SR402
SR405/SR410
SR401
CIS1
F-6-5
72
Chapter 6
<Printer Unit>
T-6-4
SR206 Waste toner full detection sensor Detects the waste toner full status.
SR207 No.1 paper full sensor Detects the No.1 paper full status.
73
Chapter 6
T-6-5
T-6-6
SR207
SR203 [1]
SR208
SR101
SR210
SR204
SR209 SR202 SR206
F-6-6
6.5 Switch
74
Chapter 6
<Reader Unit>
The reader unit has no switch.
<Printer Unit>
SW4 Cassette 1 size detection switch Detects the cassette 1 paper size.
SW2
SW3 SW4
F-6-7
75
Chapter 6
<Reader Unit>
H4
H3
F-6-8
<Printer unit>
76
Chapter 6
H1,H2
H6 FM3-3712(100V)
FM3-3714(230V)
VA1 FH5-3543
H1, H2
VA1 SP1
H6
F-6-9
6.7 PCBs
77
Chapter 6
<Reader Unit>
[1]
F-6-10
<Printer unit>
Image processor PCB FM3-3320(LCD type) processes output image data for the printer unit
[3]
FM3-3319(Touch panel type)
128MB RAM FM3-3324 temporarily retains image data
[4]
Operation panel PCB Operation panel unit controls the operation panel
FK2-5340(LCD type: USA/others)
FK2-5341(LCD type: Europe)
[14] FK2-5342(LCD type: China)
FK2-5343(LCD type: Taiwan)
FK2-5344(LCD type: Korea)
FM3-3620(Touch panel type)
78
[3]
[2] [4]
[5]
[6]
[1]
[7]
[8]
[9]
[10]
[13]
[12] [11]
F-6-11
[14]
[17]
[15]
[16]
F-6-12
Chapter 7
iR2018
79
Chapter 7
[4]
[3]
[2]
[1]
[5]
[11]
[12]
[10]
[6]
[9]
[7]
[6]
[7]
[8]
[8]
F-7-1
[2] Platen Cover Type J (*1) [8] Cassette Heater Attachment Kit-E1
80
Chapter 7
iR2018i
[2]
[1]
[3]
[9]
[10]
[8]
[4]
[7]
[5]
[5]
[4]
[6]
[6]
F-7-2
81
Chapter 7
[2] [4]
[1]
[3]
[10]
[11]
[5]
[9]
[8]
[6]
[7] [7]
F-7-3
82
Chapter 7
[2]
[1]
[3]
[8]
[9]
[7]
[6]
[4]
[5]
[5]
F-7-4
83
Chapter 7
iR2018 / iR2022
[1]
[3] [2]
F-7-5
*1: To operate the heaters, a heater PCB is required. These parts are supplied as service parts, not the standard items.
84
Chapter 7
iR2018i
[1]
[3] [2]
F-7-6
*1: To operate the heaters, a heater PCB is required. These parts are supplied as service parts, not the standard items.
85
Chapter 7
[1]
[3] [2]
F-7-7
*1: To operate the heaters, a heater PCB is required. These parts are supplied as service parts, not the standard items.
86
Chapter 7
iR2018 / iR2022
[1]
[2]
[3]
[4]
[5]
[8]
[7]
[6]
F-7-8
87
Chapter 7
[1]
[2]
[3]
[7]
[4]
[5]
[6]
F-7-9
88
Chapter 7
iR2018 / iR2022
The following is a brief explanation of the functions expected of the accessories; for details, see the chapters that follow:
The following is a brief explanation of the functions expected of the accessories; for details, see the chapters that follow:
Color Send Kit-L1
UFR II printer function (Resolution: 1200dpi) ==> UFRII LT Printer Kit-V1
89
Chapter 7
iR2030
90
Chapter 7
91
Chapter 7
iR2025
92
Chapter 7
93
Chapter 7
T-7-1
94
Chapter 7
iR2022i / iR2022
95
Chapter 7
96
T-7-2
Paper size Single-sided Double-sided
Casette feed Manual feed Casette feed Manual feed
Plain paper A4 22 22 21 21
A5 25.5 25.5 - -
A5R - 9.5 - 9
B5 23 23 22.5 22.5
B5R 9 9 9 9
A4R 11 11 9.5 9.5
B4 11 11 9 9
A3 15 15 10 10
STMT 10.5 10.5 - 9
STMTR - 9.5 - 9
EXE - 23 - 21
LTR 22 22 27.5 27.5
LTRR 11.5 11.5 9.5 9.5
LGL 11 11 9 9
LDR 15 15 9.5 9.5
8K 10.5 10.5 9 9
16K 23 23 22.5 22.5
16KR 11 11 9 9
Heavy paper; 81 to 105g/ A4 23 (-) 23 (23) 22 (-) 22 (-)
m2 *1 A5 47.5 (-) 17.5 (7.5) - -
(Heavy paper; 106 to A5R - 10 (7) - 8 (-)
128g/m2 *2) B5 16.5 (-) 16.5 (8) 16 (-) 16 (-)
B5R 8 (-) 8 (7.5) 7.5 (-) 7.5 (-)
A4R 9.5 (-) 9.5 (5.5) 9 (-) 9 (-)
B4 9.5 (-) 9.5 (6.5) 8.5 (-) 8.5 (-)
A3 14 (-) 14 (14) 9.5 (-) 9.5 (-)
STMT 9 (-) 9 (8) - 8 (-)
STMTR - 8 (7.5) - -
EXE - 16.5 (8) - 15.5 (-)
LTR 22.5 (-) 22.5 (22.5) 22 (-) 22 (-)
LTRR 9.5 (-) 9.5 (4.5) 9 (-) 9 (-)
LGL 9.5 (-) 9.5 (4.5) 8.5 (-) 8.5 (-)
LDR 13.5 (-) 13.5 (13.5) 9.5 (-) 9.5 (-)
8K 9 (-) 9 (4.5) 8 (-) 8 (-)
16K 16.5 (-) 16.5 (8) 16 (-) 16 (-)
16KR 9.5 (-) 9.5 (4.5) 8.5 (-) 8.5 (-)
Bond paper *3 A4 - 7.5 (6) - 7.5 (6)
A5 - 6 (5) - -
(Bond paper H *4)
A5R - 6 (5) - 6 (4.5
B5 - 6 (5) - 6 (5)
B5R - 5.5 (4.5) - 5.5 (4)
A4R - 4.5 (4) - 4.5 (3.5)
B4 - 5.5 (4.5) - 5 (4)
A3 - 6 (5) - 6 (5)
STMT 6.5 (5) 6.5 (5) - -
STMTR - 6 (5) - 5.5 (4.5)
EXE - 6 (5) - -
LTR 7.5 (6) 7.5 (6) 7.5 (6) 7.5 (6)
LTRR 4.5 (4) 4.5 (4) 4.5 (3) 4.5 (3)
LGL 4 (3.5) 4 (3.5) 3.5 (3) 3.5 (3)
LDR 6 (5) 6 (5) 6 (5) 6 (5)
8K - - - -
16K - - - -
16KR - - - -
OHP A4 - 30 - -
LTR - 30 - -
Envelope Monarch - 6.1 - -
COM10 - 6 - -
ISO-B5 - 6.1 - -
ISO-C5 - 6 - -
DL - 6 - -
Postcard Postcard - 11.5 - -
Double postal card - 10.5 - -
4-plane post card - 23.5 - -
iR2018 / iR2018i
T-7-3
Paper size Single-sided Double-sided
Casette feed Manual feed Casette feed Manual feed
Plain paper A4 18 18 18 18
A5 25.5 25.5 - -
A5R - 9.5 - 9
B5 23 23 22.5 22.5
B5R 9 9 9 9
A4R 11 11 9.5 9.5
B4 11 11 9 9
A3 15 15 10 10
STMT 10.5 10.5 - 9
STMTR - 9.5 - 9
EXE - 23 - 21
LTR 18 18 27.5 27.5
LTRR 11.5 11.5 9.5 9.5
LGL 11 11 9 9
LDR 15 15 9.5 9.5
8K 10.5 10.5 9 9
16K 23 23 22.5 22.5
16KR 11 11 9 9
Heavy paper; 81 to 105g/ A4 23 (-) 23 (23) 22 (-) 22 (-)
m2 *1 A5 47.5 (-) 17.5 (7.5) - -
(Heavy paper; 106 to A5R - 10 (7) - 8 (-)
128g/m2 *2) B5 16.5 (-) 16.5 (8) 16 (-) 16 (-)
B5R 8 (-) 8 (7.5) 7.5 (-) 7.5 (-)
A4R 9.5 (-) 9.5 (5.5) 9 (-) 9 (-)
B4 9.5 (-) 9.5 (6.5) 8.5 (-) 8.5 (-)
A3 14 (-) 14 (14) 9.5 (-) 9.5 (-)
STMT 9 (-) 9 (8) - 8 (-)
STMTR - 8 (7.5) - -
EXE - 16.5 (8) - 15.5 (-)
LTR 22.5 (-) 22.5 (22.5) 22 (-) 22 (-)
LTRR 9.5 (-) 9.5 (4.5) 9 (-) 9 (-)
LGL 9.5 (-) 9.5 (4.5) 8.5 (-) 8.5 (-)
LDR 13.5 (-) 13.5 (13.5) 9.5 (-) 9.5 (-)
8K 9 (-) 9 (4.5) 8 (-) 8 (-)
16K 16.5 (-) 16.5 (8) 16 (-) 16 (-)
16KR 9.5 (-) 9.5 (4.5) 8.5 (-) 8.5 (-)
Bond paper *3 A4 - 7.5 (6) - 7.5 (6)
A5 - 6 (5) - -
(Bond paper H *4)
A5R - 6 (5) - 6 (4.5
B5 - 6 (5) - 6 (5)
B5R - 5.5 (4.5) - 5.5 (4)
A4R - 4.5 (4) - 4.5 (3.5)
B4 - 5.5 (4.5) - 5 (4)
A3 - 6 (5) - 6 (5)
STMT 6.5 (5) 6.5 (5) - -
STMTR - 6 (5) - 5.5 (4.5)
EXE - 6 (5) - -
LTR 7.5 (6) 7.5 (6) 7.5 (6) 7.5 (6)
LTRR 4.5 (4) 4.5 (4) 4.5 (3) 4.5 (3)
LGL 4 (3.5) 4 (3.5) 3.5 (3) 3.5 (3)
LDR 6 (5) 6 (5) 6 (5) 6 (5)
8K - - - -
16K - - - -
16KR - - - -
OHP A4 - 30 - -
LTR - 30 - -
Envelope Monarch - 6.1 - -
COM10 - 6 - -
ISO-B5 - 6.1 - -
ISO-C5 - 6 - -
DL - 6 - -
Postcard Postcard - 11.5 - -
Double postal card - 10.5 - -
4-plane post card - 23.5 - -
Source
Type Paper size
Manual Feed Tray Cassette
Plain paper, eco paper, recycled paper A3, B4, A4, A4R, B5, B5R, A5, LDR, LGL, LTR, Yes Yes
(64-90g/m2) LTRR, STMT, 8K, 16K
Chapter 8 Upgrading
8.1 Upgrading
iR2018 / iR2022
This machine and options can be upgraded by downloading system software programs from the personal computer (hereafter called as the PC) in which a service
support tool (hereafter called SST) has been loaded.
System software programs and upgrade tools are listed in the following table:
T-8-1
SST
Main unit System (main controller) The main controller also controls
Yes the reader.
97
Chapter 8
This machine and options can be upgraded by downloading system software programs from the personal computer (hereafter called as the PC) in which a service
support tool (hereafter called SST) has been loaded.
System software programs and upgrade tools are listed in the following table:
T-8-2
SST
Main unit System (main controller) Yes Main controller also controls the reader.
*1. PCL_common is the software stored in the optionally available extended 32MB ROM PCB. It consists of the firmware for PCL printer function and the main
control firmware. Inserting the 32MB ROM PCB in the extended slot in the image processor PCB allows the main controller to operate under the control of the
firmware stored in the 32MB ROM PCB.
iR2018 / iR2022
Main unit PC
USB cable
Flash ROM CPU
J303
SST
Downloader
PCB
Finisher-U2 FY9-2034
F-8-1
When using the SST, select "#DOWNLOAD" in the service mode to place the main unit in the download mode. (The finisher need not enter the download mode.)
98
Chapter 8
Main unit PC
SST
USB Memory
FY9-2034
PCL printer kit-W1
Flash ROM
Finisher-U2
F-8-2
When using the SST, select "#DOWNLOAD" in the service mode to place the main unit in the download mode. (The finisher need not enter the download mode.)
99
Aug 8 2007