User Manual: Powermust 400/600/800 Usb
User Manual: Powermust 400/600/800 Usb
USER MANUAL
28-2BLA000133
1
IMPORTANT SAFETY INSTRUCTIONS
2
CONTENTS
1. Introduction 1
3. System Description 3
5. Trouble Shooting 6
6. Specification 7
614-05790-04
3
PowerMust 400/600/800 USB User Manual
1. Introduction
This UPS is specially designed for Personal Computer with multi-functions.
Its light weight, compact design perfect fits to the limited working
environment. The line of UPS is equipped with boost and buck AVR to
stabilize input voltage range. It is also built-in with DC start function.
This function enables the UPS to be started up without AC power supplied.
Although it’s a small UPS, it’s equipped with Smart RS-232
Communication Port to offer users more benefits. The download software
helps users monitor UPS inside status. The main features of PowerMust
400/600/800 USB UPS are listed below:
.
2. Safety – Caution
z This UPS utilizes voltages that may be hazardous. Do not attempt to
disassemble the unit. The unit contains no user serviceable parts.
Only factory service personnel may perform repairs.
z Internal battery voltage is 12Vdc.
z Connection to any other type of receptacle other than a two-pole,
three-wire grounded receptacle may result in shock hazard as well as
violate local electrical codes.
z In the event of an emergency, press the OFF button and disconnect
the power cord from the AC power supply to properly disable the
UPS.
z Do not allow liquids or any foreign object to enter the UPS. Do not
place beverages or any other liquid-containing vessels on or near the
unit.
z This unit intended for installation in a controlled environment
(temperature controlled, indoor area free of conductive contaminants).
Avoid installing the UPS in locations where there is standing or
running water, or excessive humidity.
4
z Do not plug the UPS input into its own output.
z Do not attach a power strip or surge suppressor to the UPS.
z Do not attach non-computer-related items, such as medical
equipment, life-support equipment, microwave ovens, or vacuum
cleaners to UPS
z To reduce the risk of overheating the UPS, do not cover the UPS’
cooling vents and avoid exposing the unit to direct sunlight or
installing the unit near heat emitting appliances such as space
heaters or furnaces.
z Unplug the UPS prior to cleaning and do not use liquid or spray
detergent.
z Do not dispose of batteries in a fire as they may explode.
z Do not open or mutilate the battery or batteries. Released electrolyte
is harmful to the skin and eyes. It may be toxic.
z A battery can present a risk of electrical shock and high short circuit
current. The following precautions should be observed when working
on batteries:
1) Remove watches, rings, or other metal objects from the hands.
2) Use tools with insulated handles.
3) Wear rubber gloves and boots.
4) Do not lay tools or metal parts on top of batteries.
5) Disconnect charging source prior to connecting or disconnecting
batteries terminals.
z Servicing of batteries should be performed or supervised by
personnel knowledgeable of batteries and the required precautions.
Keep unauthorized personnel away from batteries.
z When replacing batteries, replace with the same number and type of
sealed lead-acid battery.
z This pluggable type A equipment with battery already installed by the
supplier is operator installable and may be operated by laymen.
z During the installation of this equipment it should be assured that the
sum of the leakage currents of the UPS and the connected loads
does not exceed 3.5mA
z Attention, hazardous through electric shock. Also with disconnection
of this unit from the mains, hazardous voltage still may be accessible
through supply from battery. The battery supply should be therefore
diconnected in the plus and minus pole at the connectors of the
battery when maintenance or service work inside the UPS is
necessary.
z The mains socket outlet that supplies the UPS shall be installed near
the UPS and shall be easily accessible.
5
3. System Description
Front panel:
1. Power Switch
2. LED Indicators –
For 400/600 Model: For 800 Model:
Battery Mode: Green LED flashing Battery Mode: Yellow LED flashing
Back Panel--
1. Output receptacles 4. RS-232 Communication Port
2. AC input with AC fuse 5. USB Port
3. Modem/Phoneline Surge
Protection
6
4. Installation and operation
Installing the UPS is as easy as following the steps shown. Be aware of the
Power Switch must be kept in the “ON” position, otherwise, the UPS will be
disabled and your equipment will not be protected during a power failure.
1. Inspection
Remove the UPS from its packaging and inspect it for damage that
may have occurred during shipping. If any damage is discovered,
repack the unit and return it to the place of purchase.
2. Placement
Install the UPS unit in any protected environment that provides
adequate airflow around the unit, and is free from excessive dust,
corrosive fumes and conductive contaminants. Do not operate your
UPS in an environment where the ambient temperature or humidity is
high. On the other hand, place the UPS away from the monitor at
least 20cm to avoid interference.
3. Charging
This unit is shipped from the factory with its internal battery fully
charged, however, some charge may be lost during shipping and the
battery should be recharged prior to use. For 400/600 models, plug the
unit into an appropriate power supply and allow the UPS to charge fully
by leaving it plugged in for at least 8 hours with no load (no electrical
devices such as computers, monitors, etc.) connected. For 800 Model,
please charge at least 4 hours.
7
4. Computer Connection
Connect one computer-related device into each of the power
receptacles supplied on the back of the UPS.
5. Modem/Phoneline Connection
Plug incoming internet line into the “In” socket at the back of the UPS.
Use one more internet line cable and plug one end of the internet line
cable to the “Out” socket at the back of the UPS. Plug the other end
to the modem input socket as shown below.
7. Turn On/Off
PowerMust 400/600/800 USB series will be turned on automatically at
first plug-in. At this moment, press power switch lightly to turn off the
UPS. To turn on the UPS unit, press the power switch lightly. To turn
off the UPS unit, press the power switch again.
8
8. DC Start Function
DC Start Function enables UPS to be started up when AC utility power
is not available and battery is fully charged. Just simply press the
power switch to turn on the UPS.
9. Software Installation – WinPower (FOR WINDOWS O/S)
1. Insert the installation CD into CD-ROM drive and then follow the
on-screen instructions. If there no screen shows when inserting the
CD after 1 minute, please execute setup.exe for initiating
installation software.
2. Enter Serial No: 511C1-01220-0100-478DF2A to install the
software.
When your computer restarts, the WinPower software will appear as a
green plug icon located in the system tray, near the clock.
5. Trouble Shooting
Symptom Possible Cause Remedy
No LED display on 1. Missing battery. 1. 400/600 models: Charge
the front panel. battery up to 8 hours.
800 model: Charge battery
up to 4 hours.
2. Battery defect. 2. Replace with the same type
of battery.
Alarm buzzer beeps Overload of the UPS. Verify that the load matches
continuously when the UPS capability specified in
AC supply is normal. the specs.
10