TEST MODE
COLD RESET (MAIN UNIT)
The cold reset clears data except BD/DVD data stored in the RAM
to initial conditions. Execute this mode when returning the unit to
the customers.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Touch the [STOP ] and [VOL –] sensors simultaneously and hold down (around
5 seconds).
3. The message “RESET” appears on fluorescent indicator tube, then becomes
standby states.
COLD RESET (SURROUND AMPLIFIER)
Execute this mode when returning the unit to the customers.
Note 1: The main unit corresponding to TA-SA300WR, wireless transceivers
(EZW-RT50 (HBD-N790W/N890W/N990W/T79) or EZW-RT20 (HBD-N995W)) (2
units) and the remote commander corresponding to the main unit are necessary to
execute this mode.
Procedure:
10. Press the [HOME] button on the remote commander to enter the home menu.
11. Press the [UP]/[DOWN]/[LEFT]/[RIGHT] buttons on the remote commander to
select “Setup” > “Network Settings”, and press the [ENTER ] button on the remote
commander.
12. Press the [UP]/[DOWN] buttons on the remote commander to select
“Network Connection Diagnostics”, and press the [ ENTER ] button on the remote
commander.
13. Press the [LEFT]/[RIGHT] buttons on the remote commander to select “Start”,
and press the [ ENTER] button on the remote commander.
14. Confirm that “Network connections are correct” is displayed.
15. Press the [POWER] button to turn the power off.
DEMO MODE
This mode let you lock the disc slot. When this mode is activated,
the disc will not eject when the [EJECT] sensor is touched. The message “DEMO
LOCK” will be displayed on the fluorescent indicator tube.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Insert a disc.
3. Press the [HOME] button on the remote commander to enter the home menu.
4. Touch the [STOP] and [EJECT] sensors simultaneously and hold down until
“DEMO.LOCK” or “DEMO OFF” displayed on the fluorescent indicator tube
(around 5 seconds).
Releasing method:
Touch the [STOP] and [EJECT] sensors simultaneously and hold down until
“DEMO OFF” displayed on the fluorescent indicator tube (around 5 seconds).
PANEL TEST
Procedure:
1. Press the [POWER] button to turn the power on.
2. Press button in order of the [DISPLAY] > [0] > [0] > [1] > [SUBTITLE] on the
remote commander (Make the interval when each button is pressed within two
seconds).
3. All segments in fluorescent indicator tube are lighted up. And half segments in
fluorescent indicator tube are lighted up, others half segments in fluorescent
indicator tube are lighted up, then all segments in fluorescent indicator tube are
lighted up. This operation is repeated.
4. When all segments in fluorescent indicator tube are lighted up in the state of
step 3, press the [VOL +] button on the remote commander and model information
is displayed on the fluorescent indicator tube. Each time the [VOL +] button on the
remote commander is pressed, the display changes from destination information,
STR version in this order, and returns to the model information display. Each time
the [VOL –] button on the remote commander is pressed, the version and date are
switched.
5. In the state of step 3, press the [FUNCTION] button on the remote commander
and “K 0” is displayed on the fluorescent indicator tube. “K 0” value increases
whenever a button or sensor on the unit is pressed. However, once a button or
sensor has been pressed, it is no longed taken into account. All button and
sensors on the unit are pressed, “OK” and “K 7” are alternately displayed on the
fluorescent indicator tube.
6. In the state of step 3, press the [VOL –] button on the remote commander and
“RM” is displayed on the fluorescent indicator tube. Confirm that “L RM R” is
displayed on the fluorescent indicator tube, while pressing the [VOL –] button on
the remote commander.
The remote control receiver (IC903 on the FL board and IC951 on the SIRCS
board) may be defective when “L” and “R” are not displayed.
Releasing method:
To release from this mode, press the [POWER] button.
DISC SLOT LOCK MODE
The EJECT operation by main unit, remote commander, and CEC (path-through)
can be prohibited.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Insert a disc.
3. Press button in order of the [DISPLAY] > [0] > [0] > [4] > [SUBTITLE] on the
remote commander.
(Make the interval when each button is pressed within two seconds)
4. “TLK ON” is displayed on the fluorescent indicator tube, and the EJECT
operation by main unit, remote commander, and CEC (path-through) is prohibited.
Releasing method:
1. Press button in order of the [DISPLAY] > [0] > [0] > [4] > [SUBTITLE] on the
remote commander. (Make the interval when each button is pressed within two
seconds)
2. “TLK OFF” is displayed on the fluorescent indicator tube, and the EJECT
operation by main unit, remote commander, and CEC (path-through) become
effective.
FACTORY INITIALIZE
Return all of the unit setting to their factory defaults.
Note 1: Disconnect the following connections when you use this mode.
# Front USB
# Rear USB
# LAN
# HDMI IN 1
# HDMI IN 2
Note 2: The operation in this mode must use a remote commander and TV
monitor.
Procedure:
1. Press the [POWER] button to turn the power on.
2. Press the [HOME] button on the remote commander, and the home menu is
displayed.
3. Select “Setup” > “Resetting”, and press the [ ENTER ] button on the remote
commander.
4. Select “Initialize Personal Information”, and press the [ENTER] button on the
remote commander.
5. Select “OK”, and press the [ ENTER ] button on the remote commander.
6. The message “Close” appears, and press the [ENTER ] button on the remote
commander.
7. Select “Reset to Factory Default Settings”, and press the [ENTER] button on the
remote commander.
8. Select “All Settings”, and press the [ENTER ] button on the remote commander.
9. Select “Start”, and press the [ ENTER ] button on the remote commander.
10. Initialization ends when the message “WELCOME” on the fluorescent indicator
tube disappears.
BD SERVICE MODE
Setting method of the BD service mode:
1. Connect this unit with TV monitor.
2. Press the [POWER] button to turn the power on.
3. Press button in order of the [DISPLAY] > [0] > [2] > [1] > [SUBTITLE] on the
remote commander. (Make the interval when each button is pressed within
two seconds)
4. Enter the BD service mode. The OSD menu on TV monitor can be operated
by remote commander.
Main Functions
# Diag
Performs unit test of devices installed on the board.
# Display Error Log
Error log is displayed. Displayed contents can also be saved in
an USB memory device.
# Factory Initialize
Restores the unit to its factory settings.
# Network
Checks the wired network connection.
# Version Up
Not used.
# System Information
Displays the system information of the unit.
Procedure:
1. Remove the INSULATOR (4 pieces) and broken optical device (KEM-480AAA)
from LOADING ASSY.
2. Take photo of the barcode on new optical device (KEM- 480AAA) bottom side
by digital camera.