0% found this document useful (0 votes)
81 views16 pages

DBR - Pune Residential Rev-1

The document provides the design basis for a module mounting structure and foundation for a rooftop solar project in Pune. It details the project information, design criteria including loads, load combinations, structure information and STAAD output for the structural analysis and foundation design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
81 views16 pages

DBR - Pune Residential Rev-1

The document provides the design basis for a module mounting structure and foundation for a rooftop solar project in Pune. It details the project information, design criteria including loads, load combinations, structure information and STAAD output for the structural analysis and foundation design.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

CLIENT:

DESIGN BASIS
MODULE MOUNTING STRUCTURE AND
FOUNDATION
PROJECT: PUNE ROOFTOP SYSTEM DESIGNER

1|Page Doc No:


Design Basis Report for MMS and Foundation
Revisions

No: Date Engineer-in-charge Notes


A 27 – 11- 2020 M.T. / N.P. Rev 0
B 04 – 12- 2020 M.T. / N.P. Rev 1

2|Page Doc No:


Design Basis Report for MMS and Foundation
Table of Contents
Table of Contents
1.0 Project Information .................................................................................................................................................................................................................................................................................................................... 4
2.0 Design Criteria ............................................................................................................................................................................................................................................................................................................................ 4
2.1 Input Parameters ................................................................................................................................................................................................................................................................................................................... 4
2.2 Reference Codes and Other Documents ............................................................................................................................................................................................................................................................................... 4
2.3 Design Loads .......................................................................................................................................................................................................................................................................................................................... 4
2.4 Load Combinations............................................................................................................................................................................................................................................................................................................ 6
3.0 STRUCTURE INFORMATION: ...................................................................................................................................................................................................................................................................................................... 6
4.0 STAAD OUTPUT: ......................................................................................................................................................................................................................................................................................................................... 7
........................................................................................................................................................................................................................................................................................................................................................ 12
........................................................................................................................................................................................................................................................................................................................................................ 12
5.0 FOUNDATION DESIGN : ............................................................................................................................................................................................................................................................................................................ 13

3|Page Doc No:


Design Basis Report for MMS and Foundation
1.0 Project Information
The following design is to be installed on the roof of a Residential building located in Hingewadi, Pune by Solar Square.

2.0 Design Criteria


2.1 Input Parameters
a) Tilt Angle: 10 degrees
b) Location: Pune
c) Wind Speed: 140 kmph (40 m/s)
d) Minimum Ground Clearance 700 mm
e) Configuration: 1P
MATERIAL:

PART Material
DESCRIPTION Coating
No. Grade Section
Column – cold formed 150CS75X15X2.5(Lipped
1 E350 HDG
section Channel)
Rafter – cold formed 80CS35X10X2(Lipped
2 E550 HDG
section Channel)
110CS50X10X1.2(Lipped
Channel)
3 E550 HDG &
Purlin – cold formed 110CS50X10X1.5(Lipped
section Channel)
Sag Rod– hot rolled 12 mm dia rod
4 E250 HDG
section

2.2 Reference Codes and Other Documents


1. IS 875:3-2015 – Wind Loads for Buildings and other Structures
2. IS 801 – Indian Specification for Design of Cold-formed Steel Structural Sections
3. IS 800 – Indian Specification for Design of Hot rolled Steel Structural Sections

2.3 Design Loads


DEAD LOADS: The weight of a single module is taken as 22.5 kg.

WIND LOADS:
The following describes the wind calculation in detail as IS 875:3:2015

4|Page Doc No:


Design Basis Report for MMS and Foundation
5|Page Doc No:
Design Basis Report for MMS and Foundation
2.4 Load Combinations
STRENGTH:
1.0 DEAD + 1.0 WIND DOWN
1.0 DEAD + 1.0 WIND UP

SERVICE:
DEAD + WIND

DURABILITY: Expected life of structure would be minimum 25 years. Hot-dip-galvanizing to be adopted.

3.0 STRUCTURE INFORMATION:


• This is a double columned structure with single PV Module arranged in Portrait configuration.
• The structure is modelled using line elements on standard Finite Element Software’s.
• There are members connected at the mid length of the purlins for preventing sagging.

6|Page Doc No:


Design Basis Report for MMS and Foundation
4.0 STAAD OUTPUT:

All members are passing.


Purlins have been designed with the help of a software named as CFS as follows:

7|Page Doc No:


Design Basis Report for MMS and Foundation
8|Page Doc No:
Design Basis Report for MMS and Foundation
9|Page Doc No:
Design Basis Report for MMS and Foundation
________ ______________________

10 | P a g e Doc No:
Design Basis Report for MMS and Foundation
11 | P a g e Doc No:
Design Basis Report for MMS and Foundation
12 | P a g e Doc No:
Design Basis Report for MMS and Foundation
5.0 FOUNDATION DESIGN :
STAAD output for support reactions:

Horizontal Vertical Horizontal Moment Moment Moment


Node L/C Fx kN Fy kN Fz kN Mx kNm My kNm Mz kNm
Max 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Fx 85 X 1.189 -2.155 -0.032 -0.019 -0.006 -0.202
Min
Fx 85 16 1*DEAD + 1*WIND DOWN 0 DEG + 1*LAT -Z -0.264 0.959 0.307 0.12 0.04 -0.026
Max
Fy 81 16 1*DEAD + 1*WIND DOWN 0 DEG + 1*LAT -Z 0.064 0.987 0.327 0.104 0 -0.02
Min 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Fy 86 X 1.188 -2.155 0.034 0.021 0.007 -0.202
Max 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Fz 91 X 0.916 -1.659 1.617 0.261 0.086 -0.146
Min 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Fz 87 X 0.94 -1.659 -1.613 -0.259 -0.085 -0.159
Max 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Mx 91 X 0.916 -1.659 1.617 0.261 0.086 -0.146
Min 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Mx 87 X 0.94 -1.659 -1.613 -0.259 -0.085 -0.159
Max 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
My 91 X 0.916 -1.659 1.617 0.261 0.086 -0.146
Min 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
My 87 X 0.94 -1.659 -1.613 -0.259 -0.085 -0.159
Max
Mz 68 15 1*DEAD + 1*WIND UP 0 DEG +1*LAT +Z 0 0.009 0 0 0 0
Min 13 1*DEAD + 1*WIND UP 10 DEG NO ECC +1*LAT -
Mz 81 X 1.17 -2.098 -0.235 -0.094 0 -0.404
The
The columns of the structure have been connected with beams which have been designed in order to counter the Uplift pressure adequately.

13 | P a g e Doc No:
Design Basis Report for MMS and Foundation
Structure has been checked for overturning and found safe.
Providing 12 mm thick base plate with following specifications:

14 | P a g e Doc No:
Design Basis Report for MMS and Foundation
__________________________________end of calculations _________________________________________________________________________________________

15 | P a g e Doc No:
Design Basis Report for MMS and Foundation
16 | P a g e Doc No:
Design Basis Report for MMS and Foundation