KONTROL 500
The Kontrol 500-series are advanced controllers
designed for high-end applications. The units feature
independent proportional PID-enabled control outputs,
RS 485 serial port with MODBUS protocol, USB port
on request, probe quality checking, a variety of
outputs and full data logging capability. The user has
full programming authority.
TECHNICAL CHARACTERISTICS
Graphic display and Keypad
128 by 64 pixel resolution monochrome display with graphic icons to shoe digital output status, Data logging,
washing cycle, alarms. Simultaneous flashing values for the
measurement (numeric + bargraph) and temperature readings.
Analogue scrolling output values. Five control keys for instrument calibration and configuration.
Enclosure Box and Power Supply
Wall mounting ABS plastic material
IP65 (144x144)
Panel mounting IP54 (96x96)
Universal Power Supply 100÷240 Vac 50/60 Hz
Data logging
Internal Flash Memory with records interval from 1 to 99 min. (near to
16000 records Visualization key for stored data in tabular and graphic form.
Type: Circular (F.I.F.O.) or Filling
RS485 Serial port
For set-up and real-time dataacquisition from remote or for stored data download on PC or laptop (Communication
Software Master Controller NET required).
MODBUS RTU communication protocol
USB port
Download measuring data on removable memory Usb Pen Drive (upon request).
Measure Input
High measuring resolution with probe quality control. A modular measuring system Chlorine measure in sea water
application.
Current outputs 4÷20mA Galvanic isolation
Two independent programmable Output Measures with PID routine regulation
Relay Outputs
Four independent functions, two set points, one alarm remote output, on backwashing probe output.
On/OFF, Timed routine function setting.
Digital Input
Dedicated and level input to disable all controller output functions
APPLICATIONS
2/3/4
INSTRUMENT
TYPE
500
Kontrol 500
5/6
MEASURE
CD Conductivity
OX Dissolved oxygen
T1 Turbidity
T2 Turbidity SS
CL Potentiostatic Chlorine
ID Inductive conductivity
7
MOUNTING
P box type 96X96
W box type 144X144 (IP65)
8
POWER
SUPPLY
A 230 Vac
B 24 Vac
C 115 Vac
M Switching 80÷265 Vac
9
FREE/CUSTOM
10
FREE/CUSTOM
11
FREE/CUSTOM
12
FREE/CUSTOM
K 500 CD W A 0 0 0 0
Ind.
conducti Dissolve Chlorine SS
pH/ORP conducti potentiost Turbidity H 2O 2 C 2H 4O 3 O3
vity d oxygen turbidity
vity atic cell
K500PR ●
K500CD ●
K500ID ●
K500OX ●
K500CL ● ● ● ●
K500T1 ●
K500T2 ●
MEASURE RANGE
pH 0÷14,00
ORP ±1500mV
conductivity 0÷20/200/2000/20000/200000µS
Inductive conductivity 0÷10.000/10.000/100.000/999.999µS
Dissolved oxygen 0÷20,0 ppm or mg/l 0÷200% SAT
Chlorine 0÷0,50/1,00/2,00/5,00/10,0/20,0/200,0ppm
Turbidity 0,00÷1,00/10,0/100NTU/FTU
suspended solid turbidity 0,0÷4,00/40,0/400/4.000 NTU/FTU - 0÷30 gr/l
Hydrogen peroxide (H2O2) 0÷500/1000/2000/10.000/100.000 ppm
Peracetic Acid (C2H4O3) 0÷500/2000/10.000/20.000 ppm
Ozone (O3) 0÷0,5/2,00/5,00/10,00 ppm
temperature compensation with PT100/PT/1000 0÷100 (32÷212 °F)