0% found this document useful (0 votes)
37 views

One Way Panels Vims Sumps

This document summarizes the analysis of one-way slab conditions with triangular loading for internal and external walls. For the internal wall, the bending moment at the fixed end is negative and at midspan is positive. The required steel reinforcement is 719 sq mm and 839 sq mm. For the external wall, the bending moment at the fixed end is negative and at midspan is positive. The required steel reinforcement is 620 sq mm and 723 sq mm.

Uploaded by

Kumar Harsha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
37 views

One Way Panels Vims Sumps

This document summarizes the analysis of one-way slab conditions with triangular loading for internal and external walls. For the internal wall, the bending moment at the fixed end is negative and at midspan is positive. The required steel reinforcement is 719 sq mm and 839 sq mm. For the external wall, the bending moment at the fixed end is negative and at midspan is positive. The required steel reinforcement is 620 sq mm and 723 sq mm.

Uploaded by

Kumar Harsha
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 1

One way slab condition was done with proped cantilever with concentric load (CG of triangle load)

and found BM at fixed (negitive) end and mid span (Positive)


ONE WAY SLAB LOAD WITH TRIANGULAR LOADING
Internal Wall
Internal_LongWalls-X Direction
Geomentry:
Height of wall 2.55 m
Lenght of wall Ly 7.5 m
Width of wall Lx 2.55 m
Aspect Ratio Ly/Lx 2.94
Condition Oneway
Water_Pressure 25.5 kN/Sq.m
Force @CG from Base 2/3.H 43.35 kN per 1m runnig length
Analysis:
Assume_D 275 intenal wall
From_fixed_side a 1.7 m P
Away_fixed_side b 0.85 m
Total_height Lx 2.55 m
Force_kN P 43.35 kN a b
vertical near end 16.38 kN-m Negitive
vertical Point end 19.1 kN-m Positive
Nocrack 22.69 kN-m
Ast.+x 719.22 Sq.mm #12_dia_spacing 157
Ast.-x 839.09 Sq.mm #12_dia_ spacing 135
Min Ast 330 Sq.mm #10_dia_spacing 238

ONE WAY SLAB LOAD WITH TRIANGULAR LOADING


External wall
External_LongWalls-X Direction
Geomentry:
Height of wall 2.55 m
Lenght of wall Ly 7.5 m
Width of wall Lx 2.55 m
Aspect Ratio Ly/Lx 2.94
Condition Oneway
Earth_Pressure 17 kN/Sq.m
Force @CG from Base 2/3.H 28.9 kN per 1m running lenght
Analysis:
D 225 external wall
From_fixed_side a 1.7 m p
Away_fixed_side b 0.85 m
Total_height Lx 2.55 m
Force_kN P 28.9 kN a b
vertical near end 10.92 kN-m Negitive
vertical Point end 12.7 kN-m Positive
Nocrack 15.19 kN-m SAFE
Ast.+x 620.50 Sq.mm #12_dia_spacing 182
Ast.-x 723.92 Sq.mm #12_dia_spacing 156
Min Ast 330 #10_dia_spacing 238