Ras Markaz Crude Oil Park Project (Phase 1) : 9686-8430-14-713-4001-001 - B1. DWG Cad File Name
Ras Markaz Crude Oil Park Project (Phase 1) : 9686-8430-14-713-4001-001 - B1. DWG Cad File Name
R:1200
R:1200
K2 8-0
J:225
J:225
N10~N16 N18 4"-Portable Transmitter 1 1
8"-Anode N19 Ref Cell 26-0 Number of Units / Item No. 2 / 713-T-401A/B Shell/Roof/Bottom/Annular ASTM A36
24-0 String Cables N 6"-Gauge N21 K1
N17 28-0 API 650 12th Edition, Addenda-3 &
R:13000
A Top of Dome Roof Hatch 2 Design Code Errata-2, Annex. B,E & P, NFPA 22 2 Manways-Shell/Roof ASTM A36 A
J:275
R:13000
N3
R:13000
M3 Above Ground Cylindrical Shell
J:275
J:275
3 Roof Type 3 Nozzles Pipe-Shell/Roof ASTM A106 Gr.B
R:13000
Top Platform 24"-Roof with Fixed Dome Roof Tank
R:13000
R:8235
6-0 & Roof Handrail 9-0 Manway 4"-Spare-
R:12450
J:250
J:275
7-0
J:275
Biocide Injection TYP.
J:550
8 4 Design Life Yrs. 25 4 Flanges-Nozzle ASTM A105
3892
TOP ANGLE 15 50 5 5
Product Fire Water (Sea/Potable Water) Flanges/Covers-Manways ASTM A36
90x90x12
2"-Potable 6 6
15-0 Design Specific Gravity/Vapor Pressure -/bar(a) 1.03 / 0.069 Pipe Fittings-External/Internal A234 WPB
10
EL.+21137 (Top of Water Inlet 8 THK.
10
Platform)
7 Test Specific Gravity -/bar(a) 1.03 7 RF Pad/Support Pad/Clips ASTM A36
20" Pump 16-0
Min. flow/
(8 THK.)
(8 Thk.)
Test line H:19070 8 Toxic/Flamable/Sour Service No 8 Structural Members/Wind Girders EN S275 JR / ASTM A36
2290
2290
J:300 N9
N7B N7A H:18860
Landing#5 N4 H:18970
J:275 DESIGN LIQUID LEVEL:+18680 H:18730 9 Design Liquid Level m 18.68 9 Platform/Stairs/Ladder EN S275 JR
J:250 Top EL.+17537 HHLL:+18530 N2
J:150
4800
HLL:+18070 10 Design pressure (Internal/External) Pa ATM (Note-52) / ATM 10 Stiffeners/Welded Attachments ASTM A36
13-0 14"-Inlet from 24"-Seawater 14-0
(8 THK.)
(8 Thk.)
PSV Discharge Inlet 11 Max. Design Temperature °C 11 Bolting Nuts-External A193 Gr.B7 / A194 Gr.2H
2200
2200
85
H:17000
N5A N5B
J:300 INSIDE SHELL 12 Design Metal Temperature (Min. Temp.) °C 12 Bolting Nuts-Internal SS 304
5
SS spiral wound with non graphite filler
13 Operating pressure Pa ATM 13 Gaskets-Internal material (PTFE, Polyurethane), ASME B16.21
(8 THK.)
20"-Overflow
(8 Thk.)
2250
14 Operating Temperature (Max./Min.) °C 48.9 / 5 14 Gaskets-External with oil resistance Binder (ASME B16.21)
Top EL.+14137
B B
Intermediate Wind
17-0
15 Pumping Rates (In/Out) m3 /hr 4(Normal) 1816 - 3000 (max.) / 4908 15 Misc. Attch As Per Attached Drawings
Girder
16 Hydrotest Test Level/Test Pressure m/mbarg Overflow Liquid Level (18680mm)/ATM+Static Head 16 Other Structural Steel ASTM A36 / EN S275 JR
(10 THK.)
(10 Thk.)
2250
2250
mm
~24492
Landing#3 17 Corrosion allowance (Shell/Bottom/Roof) 1.5 17 Top Angle/Fixed Roof Supports EN S275 JR
Top EL.+10737
18 mm
Corrosion allowance (Roof Structure/Column) 0.75 all around
FOUNDATION LOAD DATA
19
(12 THK.)
(12 Thk.)
Blanketing Gas No
2250
2250
20600
NO. DESCRIPTION UNITS WEIGHT/LOAD
20600
(14 THK.)
2 t
(14 Thk.)
Landing#2 22 Shell Height (to the top end of curb angle) m 20.61 Hydro Test Weight 12681.3
2250
2250
Top EL.+7337 Spiral Stairway
5-0 3 Operating Weight t 13006.0
23 Bottom Type / Slope Cone Bottom Up / 1:120
(TYP.)
(16 THK.)
(16 Thk.)
2250
Landing#1 26 Seismic Use Group SUG I 6 Wind Moment kN·m 22221.5
Top EL.+3737
27 Roof Uniform Live Load kPa 1.0 7 Wind Shear kN 1707.1
C C
(20 THK.)
Cable Tray
(20 Thk.)
3-0
2250
2250
Support 28 Roof Snow Load kPa N/A
24"-Sell Name
21-0 Manway 20-0
Plate LLL:+2930 C / 0.55 g / 0.3 g
30"-Outlet 29 Site Class / S s / S 1 NOTE:
18-0
TOP OF ANNULAR FOR SUB-ASSEMBLY, GENERAL NOTES & LIST OF REFERENCE DOCUMENT/
PLATE 30 Importance Factor 1 DRAWING, REFER DWG. NO. - 9686-8430-14-713-4001-032
4"-Drain LLLL:+1690
(22 Thk.)
23-0 H:1550 N1
2600
2600
(22 THK.)
J:300 31 Inspection Autority Third Party Inspection
2140 SLOPE H:950 SLOPE SLOPE 8 TYP.
1 M2 M1 1 60 1
J:200 32
N8B N8A H:440
J:150 120 120 120
Post Weld Heat Treatment As Per API 650
H:0000 (Top of Bottom Plate) LEGENDS:
Sump Vortex 40 33 Radiography/MPI Yes (Refer Note-29)
60
∅29000 (I.D) Breaker Weld Cleat 1120 8 THK. XX Nozzle Number
12
Bottom 27-0 34 Dye Penetrant/Vacuum Box Test Yes (Refer Note-29)
1-0 Plate ∅29164 (Annular Bottom Plate O.D) XX-0 Assembly Number
35 Ultrasonic Test Yes (Refer Note-29)
Grounding lug
Settlement Obser-
22-0 TANK SECTION 36
TANK ELEVATION 19-0 vation Block
(N.T.S.)
PMI Ref Spec: 9686-8470-SP-000-4004
HOLD-1:
(SCALE 1:100) 37 Hardness/Impact Test Yes (Refer Note-29)
Nozzle Load Details are under HOLD.
38 HIC Testing No
D
NOZZLE SCHEDULE 39 Peripheral Roof Handrail Yes
D
RF PAD
Q'TY RATING SIZE SCH/ (ODxIDxTHK.) STANDOUT ELEVATION 40 Spiral Stairway Yes
NO. SERVICE (NOS.) THK.(MM) (MM)
FLANGES (MM) (MM)
REMARKS 41 Vertical Ladder with Cage N/A
SHELL NOZZLES 42 Walkway Yes
With Internal Pipe & Elbow (HOLD-1)
N1 Tank Outlet 1 CL. 150 30" 17.48 1545x765x22 WN RF 300 1550 and anti-vortex plate
With dip pipe
NOZZLE LOAD FOR TANK 713-T-401A 43 Roof Platform Yes
1 WXC/
N2 Potable Water Inlet CL. 300 2" SCH-160 WN FF 150 18730 B1 27/01/20 ISSUED FOR APPROVAL ZZQ HP MJH
Pump Minimum Flow
with anti siphon holes
With dip pipe
NOZ. SIZE AXIAL LOAD LONG. MOMENT CIRCUM. MOMENT 44 Earthing Bosses & Weld Lug Yes HS
N4 /Test Line Nozzle 1 CL. 150 20" 14.27 1055x511x8 WN RF 275 18970 with anti siphon holes NO. (NPS) F (N) M (N-m) AM (N-m) L C 45 Clean Out Door N/A A1 22/12/19
ISSUED TO COMPANY FOR
WXC ZZQ KDR MJH
REVIEW/COMMENTS
N5A/B Overflow Nozzle 2 CL. 150 20" 14.27 WN RF 300 N1 30" 32600 28500 28500
1055x511x8 17000 46 Intermediate Wind Girder Yes
With dip pipe V2 13/12/19 ISSUED TO IVB FOR REVIEW/COMMENTS WXC ZZQ KDR MJH
N7A/B Inlet From PSV Discharge 2 CL. 150 14" 14.27 WN RF 250 N4 20" 12700 11600 11600
750x359x8 18860 with anti siphon holes 47 Overflow Yes
N8A/B Drain 2 CL. 150 4" WN RF 175 N5A 2" 850 150 150 V1 30/11/19 ISSUED TO IVB FOR REVIEW/COMMENTS WXC ZZQ KDR MJH
SCH-120 305x117x22 440 48 Emergency Vent / Open Vent N/A / Yes
With dip pipe N5B 2" 850 150 150
N9 Seawater Inlet 1 CL. 150 24" 14.27 1255x613x8 WN RF 300 19070 with anti siphon holes REV DATE DESCRIPTION BY CH'D APP APP
49 Cathodic Protection - Internal/External Yes
N7A 2" 850 150 150
M1 Shell Manway 1 1 As Per API 650 24" SEE DWG. 200 950 With Davit & Cover
50 Leak Detection Requirement Yes REVISIONS
M2 Shell Manway 2 1 As Per API 650 24" SEE DWG. 200 With Davit & Cover N7B 2" 850 150 150
950 51 Gauge Hatch Yes CLIENT:
E
ROOF NOZZLES N9 24" 15700 17000 17000
52 Level Transmitter Yes E
N3 Spare-Biocide Injection 1 CL. 150 4" SCH-40 275x120x8 WN RF 275 SEE DWG. With dip pipe OMAN TANK TERMINAL COMPANY
with anti siphon holes 53 Cable Tray Support Yes
N6A/B SEE DWG.
(OTTCO)
/C/D Vent 4 CL. 150 12" SCH-20 600x300x8 WN RF 225 54 Access to Roof Center Yes
N10 Anode String Cables 1 1 CL. 150 8" SCH-20 450x225x8 SO RF 250 SEE DWG.
55 Name Plate Yes
EPC CONTRACTOR:
(HOLD-1)
SEE DWG.
N11 Anode String Cables 2 1 CL. 150 8" SCH-20 450x225x8 SO RF 250 NOZZLE LOAD FOR TANK 713-T-401B 中国石油管道局工程有限公司
N12 Anode String Cables 3 1 CL. 150 SO RF 250 SEE DWG.
8" SCH-20 450x225x8 NOZ. SIZE AXIAL LOAD LONG. MOMENT CIRCUM. MOMENT CHINA PETROLEUM PIPELINE ENGINEERING CO., LTD.
N13 Anode String Cables 4 1 CL. 150 8" SCH-20 450x225x8 SO RF 250 SEE DWG. NO. (NPS) F (N) M (N-m) AM (N-m) L C
F N20 Portable Ref Cell 2 1 CL. 150 4" SCH-40 275x120x8 SO RF 275 SEE DWG. N9 24" 15700 17000 17000 & BASIC DATA DRAWING
H
A1 (841 x 594)
K1 Level Transmitter (713-LIT-0016) 1 CL. 300 SEE DWG. DRAWING No: PROJECT
4" SCH-40 275x120x8 WN RF 275
No. 9686
K2 Level Transmitter (713-LIT-0017) 1 CL. 300 4" SCH-40 275x120x8 WN RF 275 SEE DWG. GWR Type 9686-8430-14-713-4001
N21 Gauge hatch 1 SEE DWG. GWR Type
NOZZLE PROJECTION DETAIL SCALE DOC. CLASS/CAT. : SHEET REV.
CL. 150 6" SCH-40 375x170x8 WN RF 275 AS SHOWN CLASS 1 / CAT 2 001 OF 032 B1
This document contains information which is subject to obligations of non-disclosure and is to be returned to Oman Tank Terminal Company L.L.C. upon request. The contents may not be copied, disclosed or made available to any third party or used other than
for the intended purpose for which it has been provided unless Oman Tank Terminal Company L.L.C. provides written consent for such copy, disclosure, availability and/or use. 4 5 6 7 CAD FILE NAME: 9686-8430-41-731-400-100_
1D
B.W
1G