1. The document provides design calculations for a doubly reinforced concrete beam subjected to a uniform distributed load. Key parameters include a beam width of 200mm, clear span of 4000mm, and design load of 62.625 KN/m. 2. Calculations are shown for the ultimate bending moment, moment capacity, and steel reinforcement areas required for tension and compression. Reinforcement details of 4-20mm bars and 5-16mm bars are provided. 3. Checks are performed to ensure the steel reinforcement areas satisfy code limits and that the designed shear reinforcement spacing of 344.78mm is greater than the minimum requirements.

Uploaded by

er.praveenraj30
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
93 views

Some Notes: Changes in Highlighted Rows Is Required As Per Design

1. The document provides design calculations for a doubly reinforced concrete beam subjected to a uniform distributed load. Key parameters include a beam width of 200mm, clear span of 4000mm, and design load of 62.625 KN/m. 2. Calculations are shown for the ultimate bending moment, moment capacity, and steel reinforcement areas required for tension and compression. Reinforcement details of 4-20mm bars and 5-16mm bars are provided. 3. Checks are performed to ensure the steel reinforcement areas satisfy code limits and that the designed shear reinforcement spacing of 344.78mm is greater than the minimum requirements.

Uploaded by

er.praveenraj30
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 3

some notes

1 make change only in red text


2 make changes required for interpolation mannualy
3 M15,M20,M25 grades only, beam subjected to udl only
4 effective corve is same in both comp and tension Ie.d'
5 CHANGES IN HIGHLIGHTED ROWS IS REQUIRED AS PER DESIGN
Beam Design (Doubly)
1 Given Data
BEAM MARK = Beam
Width of Support 200 mm
clear span = 4000 mm pt-lim%
effective cover/d' = 25 mm Fy & fck 250 415 500
Working Load 40 KN/m 1 2 3 4
Self Weight of Beam 1.75 KN/m
Dsign load=wu 62.625 KN/m
Design constant 15 1.32 0.72 0.57
pt-lim% 0.57 20 1.76 0.92 0.76
q= 0.133 25 2.2 1.19 0.94
Xu max Constant=q''= 0.46 ⇒
fck= 15
fy= 500
Size of Beam
b= 200 mm
Take D=(Span /12)= 333.333333333 mm
i.e D= 350 mm
d= 325 mm d=D-d'

2 Effective Span `
c/c distance of support = 4200 mm
Clear Span+d/2= 4162.5 mm
Le= 4162.5 mm
Le= 4.1625 m
3
Factored Bending Moment=
Mu =(wu x Le^2)/8 = 135.633273926 KN.M

4 Ultimate /moment of
Resistance=
Mur=q x fck x b x d^2 42.144375 KN.m
Xu max=q'' x d= 149.5 mm
As Mu < Mur Need to design as Doubly R. S.

5 Find Ast1 Area of Tensile Steel


pt lim= 0.57 %
Ast1=(pt lim x 100 )/(b x d)= 370.5 mm^2

Mu for Asc=Mu-Mur 93.4888989258 KN.m

for fsc & fcc


d'= 25 < 64.285 (0.43 x Xu max)
Calculate Fsc from is456
fcc in mpa d'/d
fy
0.05 0.1 0.15 0.2 make changes here (only for red)
500 424 412 395 370
415 355 353 342 329 for Fy= 500
d'/d= 0.07692307692 0.05 355
Fsc= 353.92 mpa 0.076923 353.92
Fcc=0.446 x fck= 6.69 mpa 0.1 353

6 Find Asc Area of compression Steel


Mu1for Asc=Mu-Mur 93.4888989258 KN.m
Mu1=Asc(fsc-fcc)x(d-d')
From that Asc= 897.465373539 mm^2

But for balance secton Find Ast2 for Asc


Asc(fsc-fcc)=ast2(0.87 x fy)
Ast2= 716.390030082615 mm^2

Total Ast=Ast1+Ast3 1086.89003008261 mm^2


Asc= 897.465373539207 mm^2

Provide,
Ast req Dia of bar No of Bar(Ast req/area of one bar i.e No of bar Ast provided
1086.89 20 3.45828645935377 4 1257.1 mm^2

Asc req Dia of bar No of Bar(Ast req/area of one bar i.e No of bar Asc provided
2 897.4654 16 4.4618306923114 5 1005.7 mm^2
5
Cheks

1 Check for Ast

1 Ast Min= 110.5 mm^2 0.85 b d/fy

1 Ast Max= 2800 mm^2 0.04 x b D

1 Hence ok Ast<Ast max


2 Hence ok Ast>Ast min

2 Design of beam for Shear

Wu 412 KN
le 4200 mm
d 325 mm
b 200 mm
Asteel total= 2262.85714285714 mm^2 make changes here (only for red)
For Zuc for M 15
%pt=(Ast/b x d ) x 100= 1.93406593407 1.75 0.72
Zuc= 0.77 From is 456 1.93 0.77
2 0.79
1 Vu=(Wu x l )/2 130.33828125 KN

2 Shear Resisted by Concrete

Vuc=Zuc x b x d= 50.15 KN

Shear Reinforcement is required

Shear to be resisted
3 80.18828125 KN
by Stirrups=Vu-Vuc=

Stirrups Used
1 Dia of Stirrpus 10 mm
2 leggs 3
area= 235.6125 mm^2
fy= 415 mpa
Spacing=Sv=(0.87 x fy x As x d))/Vus 344.776878051 mm
Check for Min Spacing
1 300 mm 300.00 mm
2 0.75d 243.75 mm
Sv Min=(0.87 x fy x As
3 1063.35 mm
))/(0.4b)
Take Spacing lesser of
243.75 240 mm
above

Dia of
Leggs Spacing GRADE
Provide, Stirrups
10 3 240 415
250 15
415 20
500 25

0.53 Fy & fck 250 415 500


0.48 1 2 3 4
0.46 15 1.32 0.72 0.57
20 1.76 0.92 0.76
25 2.2 1.19 0.94

500 4
15 0.57