100% found this document useful (1 vote)
651 views31 pages

RMC Petrol Dangcagan

The document contains architectural drawings for a proposed gas station and two-story commercial building project located in Poblacion, Dangcagan, Bukidnon, Philippines. It includes drawings showing the site plan, floor plans, elevations and perspectives of the buildings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
651 views31 pages

RMC Petrol Dangcagan

The document contains architectural drawings for a proposed gas station and two-story commercial building project located in Poblacion, Dangcagan, Bukidnon, Philippines. It includes drawings showing the site plan, floor plans, elevations and perspectives of the buildings.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 31

REPUBLIC OF THE PHILIPPINES

DEPARTMENT OF PUBLIC WORKS


AND HIGHWAYS

OFFICE OF THE BUILDING OFFICIAL


PROVINCE OF BUKIDNON
MUNICIPALITY OF DANGCAGAN

LAND USE AND ZONING

LINE AND GRADE

ARCHITECTURAL

STRUCTURAL

PERSPECTIVE VIEW ( GAS STATION)


ELECTRICAL

ELECTRONIC

MECHANICAL

SANITARY / PLUMBING

ASSESSOR'S OFFICE

FIRE DEPARTMENT

PERSPECTIVE VIEW ( COMMERCIAL BUILDING)


PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
1
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
20.00
S18DEG-32'W

1
4
9.00

PROPOSED 2 STOREY COMMERCIAL BUILIDNG

1.13

0.38

P P P P P
S72DEG-26'E

N71DEG-28'W

30.00
100MM CONCRETE SLAB WITH
21.26

FUEL STORAGE TANK 9mm Ø TEMP. BARS SPACED


@ 0.60M O.C. BOTH WAYS
7.00
CL

7.84 7.84
7.00

CANOPY LINE

OUT OUT
IN GAS STATION IN
2
3

N17DEG-38'E

19.57
15.OOm

CL OF NATIONAL ROAD

SITE DEVELOPMENT PLAN VICINITY MAP


SCALE 1:200M SCALE 1:200M

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
2
ARCHITECTURE & OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
PTR NO.
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
7.00

1.
65
50
4.

0.
60

W E

7.00
60
1. SLOPE
R
IE
H

TH
AS

O
C

BO
60
0.
1.
2 0

S
ROOF PLAN
FLOOR PLAN SCALE 1:50
SCALE 1:50

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
3
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
COLUMN IN PREFAB METAL CLADDING FINISH CANOPY IN PREFAB SANDWICH PANEL FINISH

TOP OF CANOPY LINE


0.90

0.90
CANOPY CEILING LINE

1.60 0.60

5.40

5.40
4.25

4.25
2.20

GROUND FLOOR LINE


0.25

0.25
NATURAL DRIVEWAY LINE

SOUTH EAST ELEVATION NORTH EAST ELEVATION


SCALE 1:100 SCALE 1:100

TOP OF CANOPY LINE


0.90

0.90
CANOPY CEILING LINE

0.60 1.60
5.40

5.40
4.25

4.25
2.20
GROUND FLOOR LINE

0.25
NATURAL DRIVEWAY LINE

SOUTH WEST ELEVATION NORTH WEST ELEVATION


SCALE 1:100 SCALE 1:100

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
4
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
Y

A B C D E
20.00
5.00 5.00 5.00 5.00

3.50
4.00

OFFICE

2 X
7.00

1.75
RENTABLE SPACE RENTABLE SPACE RENTABLE SPACE
1.00 1.00 1.00
9.00

D2
W2

3.50
D1
F D2 2.25
0.75

M D2
X 3 W1
D1
W1
D1
W1
D1
1.30
2.00

2.00
GEN SET
ROOM

D3

2.10 GROUND FLOOR PLAN


SCALE 1:100
Y

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
5
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
Y

A B C D E
20.00
5.00 5.00 5.00 5.00

1
5.00

RENTABLE SPACE

2 X

7.00
RENTABLE SPACE RENTABLE SPACE RENTABLE SPACE
W3
D1

D1

2.00
W6

RENTABLE
X 3
4.00

W1 W1 W1
D1 D1 D1
SPACE

1.00
2.00 C O R R I D O R
W4

W5

2.10 SECOND FLOOR PLAN


SCALE 1:100
Y

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
6
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E

2.00
1.00 1.00

0.30
2

7.00
SLOPE SLOPE

2.40
D1

3 0.00

1.50
W6 TYPE: FRAMELESS FULL GLASS
SLOPE
1.60 WINDOW
DESCRIPTION: GLASS
QUANTITY: 1 SET
ROOF PLAN LOCATION: RENTABLE SPACE
SCALE 1:100
6.00

4.05 2.10
1.00 1.00 1.00
5.00 1.00 1.00 2.25 2.85
1.02 1.01 1.02 1.00 1.10 1.00
1.25 1.00 0.93 0.93 1.00
0.30

0.30

0.30

0.30

0.30
2.40

2.40

2.40

2.40
D1 D1 D1 D1 D1

W1 TYPE: FRAMELESS FULL GLASS WINDOW W2 TYPE: FRAMELESS FULL GLASS W3 TYPE: FRAMELESS FULL GLASS W2 TYPE: FRAMELESS FULL GLASS W5 TYPE: FRAMELESS FULL GLASS
WINDOW WINDOW WINDOW WINDOW
DESCRIPTION: GLASS
DESCRIPTION: GLASS DESCRIPTION: GLASS DESCRIPTION: GLASS DESCRIPTION: GLASS
QUANTITY: 6 SETS
QUANTITY: 1 SET QUANTITY: 1 SET QUANTITY: 1 SET QUANTITY: 1 SET
LOCATION: RENTABLE SPACE
LOCATION: OFFICE LOCATION: RENTABLE SPACE LOCATION: RENTABLE SPACE LOCATION: RENTABLE SPACE

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
7
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
1"X1" STAINLESS STEEL RAILING
1.00 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25 0.25
2"X3" STAINLESS STEEL
HANDRAIL
0.20 1.20 0.20 1.20

EQ.
2"X2"STAINLESS

EQ.
STEEL POST
1.00

0.90
EQ.
EQ.EQ.
2.00

2"X3" METAL BASE RAIL

RAILING DETAIL BOLTED ON FLOOR


1.00

FLOORING MATERIAL

1.00 0.25 0.25 0.25 0.25 0.25 0.25

PLAN VIEW 17 2ND FLOOR


1.20
16 0.90 0.60
15
14
13
12
11
10 D2

2.10

2.10

2.00
1.00 9

3.40
8
7
6 WOODEN OR METAL TREAD

5 FINISHED FLOOR LINE

4 D1 D2 D1
3 0.25 TYPE GLASS DOOR PVC DOOR ROLL UP DOOR

METAL STRINGER
2 DESCRIPTION GLASS PVC ALUMINUM
1 QUANTITY 9 SETS 3 SETS 1 SET
0.20

LOCATION OFFICE COMFORT ROOMS GEN.SET ROOM

ELEVATION

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. EPHREM MARX APARICIO,UAP MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
10
ARCHITECTURE & ARCHITECT OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0029845 PTR NO. 1210203B
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 308-189-793 DATE ISSUED: 09-19-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
GENERAL NOTES: 4.0 Materials
7.0 Granular
1.0 General 4.1 Normal weight concrete 7.1 The granular base material shall conform to ASSTHO m147 grading A.
4.1.1 Concrete used in this work shall have a minimum compressive strength @28 days 7.2 Granular base shall be placed in position according to the required thickness
1.1 The contractor shall verify all dimensions and conditions at the site, and f 'c =20.7MPa (3,000 psi) for all reinforced concrete elements shown on the drawings. If not indicated, provide a minimum thickness of 75mm(3").
shall notify the engineer of discrepancies between actual conditions and 4.1.2 All concrete shall be deposited, vibrated and cured in accordance with ACI 7.3 Where the required thickness is more than 0.15m the base material shall be
information shown on the drawings before proceeding with the work. This standard spread and compacted in 2 or more layers of approximately equal thickness, and the
shall include the location and dimensions of grooves, sleeves, curbs, openings, 4.1.3 Minimum concrete cover for reinforcing bars shall as follows: maximum compacted thickness of any one layer shall not exceed 0.15 m.
embedded or attached items, etc. Refer to architectural, mechanical, electrical 1. Footings (cast against earth) = 75mm 7.4 Compacted dry density of each layer shall not be less than 80% of the maximum
and plumbing drawings. 2. Beams and columns (to stirrups and ties) = 40mm dry density determined according to ASTM D-698.
1.2 All dimensions shall take precedence over scale shown on plans, sections or 3. Reinfored Concrete Suspended Slab = 20mm 7.5 Maximum lift for compaction shall be 450mm.
details. Notes and details on drawings shall take precedence over general notes and
typical details. All dimensions are in meter unless otherwise specified. 4.2 Reinforcing bars 8.0 Foundation
1.3 The contract structural drawings and specifications represent the finished 4.2.1 Unless otherwise specified on plans, all reinforcing bars shall be deformed
structures. They do not indicate the method of construction unless so stated. The with a minimum yielded strength 8.1 The contractor shall report the actual condition during excavation and confirm
contractor shall provide all necessary measures to protect the structures, adjacent fy = 276 MPa for 20mmØ bars and larger. Grade 40 (40,000 psi) actual bearing capacity of soil in writing before depositing concrete. The assumed
properties, workmen and other persons during all phases of construction.The fy = 228 MPa for 16mmØ bars Grade 40 (33,000 psi) bearing capacity is 80 kPa as per soil testing result. No concrete pouring of
contractor shall immediately notify the owner and/ or the engineer of the structures fy = 228 MPa for 10mmØ secondary bars (ties and stirrups) Grade 33 (33,000psi) foundation shall be done without the approval of the Structural Engineer.
for cause distress in the structures.
8.2 Reinforced Concrete Spread Footing shall be placed as per detail.
1.4 Construction materials shall not be stored on poured floors. It is the general 4.2.2 All reinforcing bars shall be clean of rust, grease or other materials which tend 8.3 Minimum Concrete Strength of the Foundation shall be 20.7 MPa after 28 days.
contractors responsibility to ensure that the subcontractors are informed and do not to impair bond.
violate this important requirement. 4.2.3 All reinforcing bars shall accurately and securely place before pouring concrete
1.5 The contractor shall provide temporary erection bracings and shoring of all or applying mortar grout. 9.0 Standard Hooks (unit all mm)
structural members as required for structure stability during all phases of 4.2.4 Lapped splices shall be staggered where possible.
construction. 4.2.5 Unless indicated otherwise, splicing of reinforcement shall be in accordance with 9.1 Recommended end Hooks All grades of steel
1.6 The contractor shall take all steps necessary to ensure the proper alignment of ACI 318 - 14M, except that the minimum lap splice shall be 40 bar diameters but
the structures after the installation of all structural and finish materials. not less than 600mm.
1.7 Typical details and general notes shall apply to all parts of the job unless 4.2.6 Unless shown otherwise on plans, splices shall be as follows: A.) 90° Hooks B.) 180° Hooks
otherwise shown on the drawings. A. Beams : top and bottom bars shall not be spliced within the column
or within a distance of twice the member depth from the face of the For 20 mm Ø Def Bars For 20 mm Ø Def Bars
2.0 Standards and References
The following shall govern the design, fabrication and construction of the project:
column : at least two extra stirrup - ties shall be provided at all
300 80 (4d)
splices, the splice length shall not be less than 1.5 x LD

60 min
(development length), but not less than 500mm.
2.1 American Concrete Institute (ACI Publications) B. Columns : splices when permitted shall be made within the center
ACI 318-14M Bldg. Code Requirements for Reinforced Concrete. half of column height, and the lap splice shall not be less than 40 bar
ACI 315 Manual of Standard Practice for Details and Detailing diameter.
Of Concrete Reinforcement
ACI 301 Standard Specification for Structural Concrete
4.2.7 Unless indicated otherwise all beams terminating at the column shall have top 12d 175
and bottom bars extending to the far face of the column and terminating in a
2.2 American Institute Of Steel Construction (AISC) Publication standard hook 90° hook or extending to the opposite beam.
2.3 National Structural Code Of the Philippines 2015 (NSCP) 4.2.8 Shop drawings for bending & cutting of reinforcement shall be submitted for For 12 mm Ø Def Bars
For 12 mm Ø Def Bars
2.4 Association Of Structural Engineers Of the Philippines (ASEP)
Handbook Of Structural Steel Shapes and Sections, if applicable.
approval to the engineer prior to fabrication.
200 48 (4d)
2.5 Structural Analysis and Design Software by Bentley, Inc. &

50 min
4.3 Structural Steel
JCLLamberte RC Design Solution USE AISC SPECIFICATIONS
3.0 Basics Design Loads
3.1 Dead Loads 4.4 Concrete masonry units
Concrete Material = 23.544 kN/m3 4.4.1 CMU used in these works shall have a minimum ultimate compressive 12d 150
Normal Masonry Unit = 21.200 kN/m3 strength @ 28 days f m = 3.5 MPa. (500 psi)
100mm Thk. CMU Wall with opening and Parapet = 4.4145 kN/m 4.4.2 All cells shall be solidly filled with concrete mortar, concrete mortar shall have
100mm Thk. CMU Wall with openings = (0.75 x 21.20 x thickness x wall height) kN/m a minimum compressive strength of 17.20 MPa (2500 psi) @ 28 days. For 10 mm Ø Def Bars C.) 135° 10 mm Ø SEISMIC STIRRUP/TIE
100mm Thk. CMU Wall with no opening = (21.20 x thickness x wall height) 5.886 kN/m
5.0 Construction joints 150
Roofing = 0.077 KPa

110
80 (approx)
Ceiling = 0.240 kPa 5.1 Construction joints not indicated on plans shall be made so as to least impair the
100mm Thk. Reinforced Concrete Slab + floor finish = 2.3544 kPa strength of the structure and shall be subject to the approval of the engineer.
5.2 Unless shown otherwise, slab on grade shall have control joints @ 6.00 m
3.2 LiveLoads maximum center to center.
12d
Floor Live Load = 4.80 KPa (Commercial Occupancy) 6.0 Embedded Pipes in Concrete Structural Members
Ceiling Live Load = kPa 6.1 All embedded pipes for utilities, etc., shall be of a maximum size of 100 mm Ø single pipe of
Roof Live load = 1.44 KPa material as specified on the plan of as approved in writing by the the Structural Engineer. Embedded
Hallway/corridor = 4.80 kPa pipes not indicated on plans shall be made so as to least impair the strength of the structure and
3.3 Seismic Loads: shall be subject to the approval of the engineer.
Seismic Zone factor = 0.40 (Seismic Zone 4) 6.2 Such pipes when so embedded shall not take up more than six (6) percent of the
Importance factor = 1.0 Commercial Building gross area of the concrete member.
Structure Resistance factor = 8.0 Special Moment Concrete Frame 6.3 Embedded pipes across beams shall be placed above mid-height of the beam
Soil Profile Type =4 within L/4 from the support or below mid-height of the beam if placed at the
Near Source factor, Na = 1.15 6.20 km Nearest to South Bukidnon Fault middle half of the beam's length.
Near Source factor, Nv = 1.50 6.20 km Nearest to South Bukidnon Fault

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
11
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
WINDOWS OR DOOR
CUT - OFF BARS: OPENING

Ø12 MM. @40 OC 0.20 MIN TYP.


Unless otherwise shown on structural drawings:
b.TYPICAL DETAIL OF STAGGERED LAP SPLICES FOR SLAB BOTTOM BARS REBARS AT CORNER
Ø12 MM. SLAB AND SLAB
OPENING 400 400 400
Provided extra reinforcement for corner slab 100 100

WINDOW OPENING
(WHERE OCCURS)

CHB "t"
BOND BEAM OR LINTEL
(Two adjacent discontinuous edges) BEAM

CHB "t"
AS SHOWN BELOW AT ENDS &CORNER OF SHEAR WALLS

DOOR OPENING
2-Ø12 MM.

100 200
2-Ø12 MM. VERTICAL
EACH SIDE OF OPENING

5-Ø12 MM. BARS @ 200 MM. O.C. MID BARS TOP


AND BOT. 2-Ø12 MM.SILL REINF. WHERE OCCURS

BEAM
2-Ø12 MM. DOWELS
BEAM EACH SIDE OF OPENING

TYP. EXTERIOR GRND. FLR. CHB WALL OPENING


NOT DRAW TO SCALE CHB "t"
GRND.
3 FLR. WALL REINFORCING AT INTERSECTION
LAP SPLICE LENGTH: 400 LAP SPLICE
H (CLEAR HEIGHT OF COL.)

CORNER SLAB
1. AT ANY LEVEL NO MORE THAN 300 CHB WALL
ALTERNATE BARS SHOULD BE SPLICED.

CHB "t"
2. MIN. DISTANCE BETWEEN TWO

300
80 ADJACENT BAR SPLICES SHALL BE 600mm.
WITHIN CENTER

3-Ø16 MM. OF CENTER SLAB (TYP.)

400 LAP SPLICE


HALF OF "H"

L
0

1-Ø16MM. TOP AND BOTTOM BARS CHB VERT.REINF.


76

(TYP.)
L/3
0
76

16mmØ VERTICAL REINFORCEMENT


760
40

DOWEL BARS TO MATCH


HORIZONTAL REINFORCEMENT
OPEN
CHB HOR.REINF.
CHB "t"
40
760

GRND. FLR. WALL REINFORCING AT CORNER

100 200
0.20L
Ø16@100
40 40 SPLICE
HOOPS WALL REINFORCING AT
760 760
END/DOOR OPENING
SLAB OPENING 2d

CHB "t"
PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
12
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
100mm THICK CONCRETE SLAB
WITH 10mmØ MATTING BARS
@400mm SPACE O.C. B.W.

A B C D E
20000

5000 5000 5000 5000


1800 850 2350

TB TB TB TB
1
C1 C5
C2 C3 C4
F2 F2 F2 F1
F1
3500

3500
TB

TB

TB

TB

TB
C6
F3 TB TB TB TB
7000

7000
2
300

C10
F3
1100 1050 1050
8950

8950
C7 C8 C9
F4 F4 F4
3500

3500
TB

TB

TB

TB

TB
TB TB TB TB
3
C11 C12 C13 C14 C15
F3 F4 F4 F4 F3
1950

1950
1300 800 550

2100 2900
5000 5000 5000 5000

20000

FOUNDATION PLAN
SCALE: 1 : 100 METERS

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
13
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
0.10 400 mm

75 250 75
4" THK. CHB WALL
PLASTER FINISH @ BOTHSIDES 6/16
FINISHED GROUND FLOOR LINE 6/16
VARIABLE 10 MM Ø VERT

62.29 mm
3/4"

118.49 mm
REBARS SPACE AT 0.60M OC.

120
3000 PSI REINFORCED
10 MM Ø HORIZONTAL

462.29 mm
CONCRETE PEDESTAL
REBARS SP. @ EVERY 3RD LAYER

400 mm

400 mm
80 80
NATURAL GRADE LINE

400
10mmØ TIES, 6@100mm,
0.40

REST @ 150mm

120
0.60

400 mm
0.20

12#-16mmØ GRADE 40
4-12MM Ø LONG TEMP BARS VERT. BARS
Anchor detailing
400 mm

400 10MM Ø TRANSVERSE MAIN BARS Top view


@300mm spacing O.C.
H300x300x10x15
WALL FOOTING - 1 (WF1) DETAIL 400 mm STEEL
SCALE: 1 : 25 METERS
PEDESTAL

1
672(ANCHORAGE)

BASEPLATE 20mm THK.


400 400 A36
LENGTH

20 mm
300

3-#16 3-#16

500 STP 2L-#10


672(ANCHORAGE)

3-#16
3-#16

12-2L-#10 REST-2L-#10 12-2L-#10 B1


@95 C/C @165 C/C @95 C/C (SCALE 1:25)
1000 1000
1

TB:300x500
(SCALE: H = 1:50 / V = 1:50)
Lateral view Front view

TIE BEAM DETAIL


SCALE: 1 : 25 METERS
PEDESTAL & BASE PLATE DETAIL
SCALE: 1 : 10 METERS

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
14
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
2400
9 - 16mmØ (B)

9 - 16mmØ (B)

12 - 16mmØ EQUALLY SPACED

2400
2400

2400
150 THK PCC
150 THK PCC
12 - 16mmØ EQUALLY SPACED
FOOTING F2- PLAN
(SCALE 1:25)
COLUMN LINKS

FOOTING F1- PLAN

COLUMN LINKS
(SCALE 1:25)
LD

LD
12 - 16mmØ 9 - 16mmØ (B)

EL. -1.500 EL. -1.500


300

BOF

300
BOF

150 THK PCC 150 THK PCC


12 - 16mmØ 9 - 16mmØ (B)
150 2400 150 2400

SECTION 1-1 SECTION 2-2


DETAIL OF FOOTING F1 DETAIL OF FOOTING F2
(SCALE 1:25) (SCALE 1:25)
PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
15
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
8 - 16mmØ (B)

8 - 16mmØ (B)

8 - 16mmØ (B)
8 - 16mmØ (B)

1600
2300

1600
150 THK PCC
FOOTING F4- PLAN
(SCALE 1:25)

150 THK PCC

COLUMN LINKS
2300

FOOTING F3 - PLAN
(SCALE 1:25)

LD
COLUMN LINKS
LD

8 - 16mmØ (B)

EL. -1.500

300
BOF
8 - 16mmØ (B)

EL. -1.500
300

BOF 150 THK PCC


8 - 16mmØ (B)
150 1600

150 THK PCC


8 - 16mmØ (B)
SECTION 4-4
DETAIL OF FOOTING F4
150 2300 (SCALE 1:25)

SECTION 3-3
DETAIL OF FOOTING F3
(SCALE 1:25)

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
16
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E
5000 5000 5000 5000

GM3 GM3 GM3 GM3

3000

3000

3000

3000
GM4 GM4 GM4 GM4

3500

3500

3500

3500
COL

COL

COL

COL

COL
B2 B2 B2 B2

3 2 1
3500 3500

GM3 GM3
(SCALE 1:100)
3000

GM4 GM4 GM4


3500
COL

COL

COL

TB TB

MARKED SECTION SHAPE


TB RECT 500 X 300
GM4 I36A
GM3 I32A
(SCALE 1:100)
COL HW300X300

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
PROPOSED RMCC PETROL STATION AND 17
PERMISSION MUST BE 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E

20000

5000 5000 5000 5000

COL GM4 COL GM4 COL GM4 COL GM4 COL


1
3500

3500
GM4

GM4

GM4

GM4

GM4
COL GM4 COL GM4 COL GM4 COL GM4 COL
2

8000
9200

3500

3500
GM4

GM4

GM4

GM4

GM4
COL BS4 COL COL COL COL
GM4 GM4 GM4 GM4
3

1000
GM3

GM3

GM3

GM3
BS7 BS7 BS7
2200

BS4
GM4

BS4

2000

5000 5000 5000 5000

20000

(SCALE 1:100)

MARKED SECTION SHAPE


COL HW300X300
GM4 I36A
BS4 I36A
GM3 I32A
BS7 I25A

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
18
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E

20000

5000 5000 5000 5000

COL GM3 COL GM3 COL GM3 COL GM3 COL


1
3500

3500
GM3

GM3

GM3

GM3

GM3
COL GM3 COL GM3 COL GM3 COL GM3 COL
7000

7000
2
3500

3500
GM3

GM3

GM3

GM3

GM3
COL GM3 COL GM3 COL GM3 COL GM3 COL
3

5000 5000 5000 5000

20000

(SCALE 1:100)

MARKED SECTION SHAPE


COL HW300X300
GM3 I32A

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL
PROPOSED RMCC PETROL STATION AND DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
19
PERMISSION MUST BE
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E

20000

5000 5000 5000 5000 60*40*3 REC TUBE Q235B


PURLINS @ 600mm O.C.

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL

SEE RAFTER DETAIL


3500

3500
7000

7000
2
3500

3500
3

5000 5000 5000 5000

20000
ROOF FRAMING PLAN 40*3 SQUARE TUBE Q235B
SCALE 1: 100 M
ALL VERT. FRAMING 40*3 SQUARE TUBE Q235B
60*40*3 REC TUBE Q235B ALL TRUSS FRAMING
PURLINS @ 600mm O.C.
2 2 1
1361 3500 3500

387
215

464 750 1038 1038 1038 1038 1038 1038 758


26
9

RAFTER DETAIL 40*3 SQUARE TUBE Q235B


SCALE 1: 25 M ALL TRUSS FRAMING

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: JCL SHEET NO.
DRAWINGS REMAINS THE STRUCTURAL DATE: 10-25-2020
e.Aparicio
PROPERTY OF AR. EPHREM
MARX B. APARICIO WHOSE PROJECT
PROPOSED RMCC PETROL STATION AND 20
PERMISSION MUST BE 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
ARCHITECTURE & CIVIL / STRUCTURAL ENGINEER OBTAINED BEFORE ANY USE CADD BY:JCL
INTERIORS
CELL# 0997 624 3204
PRC REG. NO. PTR NO. OF IT CAN BE MADE.
REPUBLIC ACT 9266 LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN., PH. RMCC GROUP OF COMPANIES DATE: 10-25-2020 32
EMAIL:[email protected] TIN: DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
SOURCE SOURCE

METER METER

40 AMP 40 AMP
USE 2-8.0 MM^2 THHN COPPER WIRE USE 2-8.0 MM^2 THHN COPPER WIRE
ON 20 MM DIA. RSC. ON 20 MM DIA. RSC.

L.O. 15 15 L.O. L.O. C.O


C1 C2 C1 15 20 C2
C.O. 20 30 ACU ACU
C3 C4 C3 30
SPARE 20
C5

GROUND
GROUND

SINGLE LINE DIAGRAM SINGLE LINE DIAGRAM


FOR OFFICE AND PUBLIC SPACES FOR RENTABLE SPACES
C2

C1
SOURCE

METER

40 AMP
USE 2-8.0 MM^2 THHN COPPER WIRE
ON 20 MM DIA. RSC.

L.O. 15 20 C.O
C1 C2
FUEL PUMP
C3 30

ELECTRICAL LAYOUT PLAN GROUND

SCALE 1:40M

SINGLE LINE DIAGRAM


FOR GAS STATION

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
22
ARCHITECTURE & OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
PTR NO.
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E

1
C3 C3 C3 C3

2 C2
S2

C1
C2 C2 C2
S1

C1 C1 C1
S1 S2 S2 S2
S1 S2

3 S3W

S1

GROUND FLOOR ELECTRICAL LAYOUT


SCALE 1:100M

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio ENGR. ROMEO V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
23
ARCHITECTURE & ELECTRICAL ENGINEER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0002709

TIN:
PTR NO. 4550197A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E

1
C3 C3 C3 C3

2 C1
S2
C2 C2
C2 C2
S1 S3W
C1 C1 C1
C2
C1 C4 S2 S2 S2

3
C3

SECOND FLOOR ELECTRICAL LAYOUT


SCALE 1:100M

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio ENGR. ROMEO V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
24
ARCHITECTURE & ELECTRICAL ENGINEER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0002709

TIN:
PTR NO. 4550197A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
SCHEDULE OF LOADS AND DESIGN COMPUTATION ( FOR OFFICE AND PUBLIC SPACES)
NO. OF PROTECTION SWITCHES
CKT. NO. DESCRIPTION VOLTS WATTS AMPERES SIZE OF
OUTLETS SIZE OF WIRE CONDUIT
PER CIRCUIT S1 S2 S3 S3W

1 LIGHTING OUTLET 11 220 1980 9.0 15 4 2 0 1 2 - 3.5 MM^2 THHN COPPER WIRE 20 MM SYMBOLS:
2 LIGHTING OUTLET 9 220 1620 7.50 15 2 - 3.5 MM^2 THHN COPPER WIRE 20 MM

CONVENIENCE OUTLET 20 MM
LIGHTING OUTLET
3 7 220 2520 11.45 20 2 - 3.5 MM^2 THHN COPPER WIRE

4 AIRCON 2HP 1 220 1492 6.78 30 CONVENIENCE OUTLET

5 SPARE CIRCUIT HOME RUN

TOTAL 7610 34.73 4 2 0 1


PANEL BOARD
CIRCUIT BREAKER
M KILO WATT HOUR METER
SERVICE ENTRANCE
GROUD LINE
SCHEDULE OF LOADS AND DESIGN COMPUTATION (TYPICAL FOR RENTABLE SPACES) S1 SINGLE GANG SWITCH
NO. OF PROTECTION SWITCHES S2 TWO - GANG SWITCH
CKT. NO. DESCRIPTION VOLTS WATTS AMPERES SIZE OF
OUTLETS SIZE OF WIRE CONDUIT S3W THREE - WAY SWITCH
PER CIRCUIT S1 S2 S3 S3W
ACU
1 LIGHTING OUTLET 5 220 900 4.09 15 0 1 0 0 2 - 3.5 MM^2 THHN COPPER WIRE 20 MM

2 CONVENIENCE OUTLET 5 220 1800 8.18 20 2 - 3.5 MM^2 THHN COPPER WIRE 20 MM

3 AIRCON 2HP 1 220 1492 6.78 30

4 SPARE

TOTAL 4192 19.05 0 1 0 0

SCHEDULE OF LOADS FOR GAS STATION


NO. OF PROTECTION SWITCHES
CKT. NO. DESCRIPTION VOLTS WATTS AMPERES SIZE OF
OUTLETS SIZE OF WIRE CONDUIT
PER CIRCUIT S1 S2 S3 S3W

C1 LIGHTING OUTLET 7 220 1260 5.72 15 1 1 2 - 2.0mm^2 THHN COPPER WIRE 20 MM


C2 CONVENIENCE OUTLET 2 220 620 2.18 20 2 - 3.5mm^2 THHN COPPER WIRE 20 MM
C4 3HP FUEL PUMP 1 220 2238 10.17 30 2 - 3.5mm^2 THHN COPPER WIRE 20 MM
TOTAL 3040 18.07 1 1

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio ENGR. ROMEO V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
25
ARCHITECTURE & ELECTRICAL ENGINEER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0002709

TIN:
PTR NO. 4550197A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
ELECTRICAL NOTES
NOTES
COMPUTATIONS: COMPUTATIONS: 1. ALL ELECTRICAL WORKS SPECIFIED
HEREIN SHALL BE DONE IN
TYPICAL FOR TYPICAL RENTABLE SPACE FOR OFFICE AND PUBLIC SPACES ACCORDANCE WITH THE PROVISIONS
OF THE LATEST EDITION OF THE
PHILIPPINE ELECTRICAL CODE, LAWS
AND REGULATIONS OF THE LOCAL
FOR MAIN FEEDER : FOR MAIN FEEDER : UTILITY POWER COMPANY.

2. INCOMING POWERS SHALL BE 230V,


LIGHTING LOAD 900 WATTS LIGHTING LOAD 900 WATTS SINGLE PHASE, 3-WIRES; 60 HERTZ

CONVENIENCE LOAD 540 WATTS CONVENIENCE LOAD 1800


3. ALL WIRING SHALL BE IN RIGID STEEL
CONDUIT UNLESS OTHERWISE
TOTAL CONNECTED LOAD 3600 WATTS TOTAL CONNECTED LOAD 2700 WATTS
SPECIFIED.

4. BRANCH CIRCUIT AND FEEDER


APPLYING DEMAND FACTOR : APPLYING DEMAND FACTOR : WIRES SHALL BE CODED.
FIRST 3000 WATTS AT 100% DF 3600 WATTS FIRST 3000 WATTS AT 100% DF 2700 WATTS
REMAINDERS AT 35% DF (0.35 x 600) 210 WATTS 5. ALL FLUORESCENT LAMPS SHALL BE
PROVIDED WITH RAPID START/
3810 WATTS 2,700 WATTS PRE-HEAT BALLAST.
TOTAL
6. ALL MATERIALS SHALL BE NEW AND
OF THE APPROVED TYPE FOR THE
OTHER LOAD : OTHER LOAD : LOCATIONS AND PURPOSES INTENDED
TO.
ACU 2 HP AT 80% DEMAND FACTOR 1193.60 ACU 2 HP AT 80% DEMAND FACTOR 1193.60
7. ALL WORKS SHALL BE EXECUTED
1193.60 WATTS 1193.60 WATTS UNDER THE DIRECT SUPERVISIONS OF
3810 WATTS 2700 WATTS A DULY REGISTERED PROFESSIONAL
ELECTRICAL ENGINEER.
TOTAL COMPUTED LOAD 5003.06 WATTS TOTAL COMPUTED LOAD 3893 WATTS
8. CONFORM THE ARCHITECT, THE
TYPE AND COLOR RENDERING
TOTAL CATALOGS/INDEX OF LIGHTING
FIXTURES BEFORE FINAL
IT = 5003.6 IT = 3893 WATTS
INSTALLATION.
220 VOLTS 220 VOLTS
9. VERIFY ARCHITECTURAL DRAWINGS
IT = 17.69 AMPERES FOR LIGHTING FIXTURES AND WIRING
IT = 22.74 AMPERES
DEVICES INCLUDING EXACT
LOCATIONS AND MOUNTING HEIGHTS.
THEREFORE USE:
THEREFORE USE:
40 AMP MOULDED CASE CIRCUIT BREAKER, 230 VOLTS 10. REFER TO ELECTRICAL TECHNICAL
40 AMP MOULDED CASE CIRCUIT BREAKER, 230 VOLTS SPECIFICATIONS FOR FURTHER
2-8.0 MM SQ. THHN COPPER WIRE ON INSTRUCTIONS.
2-8.0 MM SQ. THHN COPPER WIRE ON
20 MM DIA. RSC. 11. NO REVISIONS IN THE DESIGN NOR
20 MM DIA. RSC.
ADDITIONAL LOADS SHALL BE DONE
WITHOUT THE PRIOR KNOWLEDGE OR
APPROVAL OF THE BUILDING
ENGINEER AND THE DESIGNER, ANY
SUCH REVISION WITHOUT APPROVAL
SHALL CAUSE RESPONSIBILITY OF THE
DESIGNER TO CEASE AS A WHOLE.

THIS SITE NOTE:


FOR BARE UNITS UP TO STUB
OUT ONLY

VICINITY MAP
NOT TO SCALE

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio ENGR. ROMEO V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
26
ARCHITECTURE & ELECTRICAL ENGINEER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0002709

TIN:
PTR NO. 4550197A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
A B C D E
20.00
5.00 5.00 5.00 5.00

1
SYMBOLS
M WATER METER

3.50
WC WATER CLOSET
4.00

LAV LAVATORY
CO CLEANOUT
SS SOIL STACK
2 DS DOWNSPOUT
7.00

FD FLOOR DRAIN
F FAUCET
1.00 1.00 1.00
9.00

WC LAV GV GATE VALVE


CV CHECK VALVE

3.50
LAV
4"Ø PVC SOIL PIPE
WC
LAV 2"Ø PVC WASTE & VENT PIPE
UR
WC PPR PN 20 DISTRIBUTION/SUPPLY LINE
3 DS
DS
DS DS DS
2.00

2.00
GV
CV

DS
M
2.10 FROM PRIVATE WATER SOURCE

CB

SEPTIC OIL AND WATER


VAULT SEPARATOR
PUBLIC
SEWER PLUMBING LAYOUT PLAN
SCALE 1:100M

PUBLIC PUBLIC
SEWER SEWER

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. ROMEL V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
27
ARCHITECTURE & MASTER PLUMBER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
0006122 PTR NO. 4550198A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
SPECIFICATIONS
1. ALL PLUMBING PLAN SPECIFICATIONS AND SHOP DRAWINGS SHALL MEET ALL REQUIREMENTS SET BY THE
NATIONAL BUILDING CODE,NATIONAL PLUMBING CODE, AND THE LOCAL CODE OF THE CITY.

2. CONSTRUCTION NOTES AND TYPICAL DETAILS APPLY TO ALL DRAWINGS UNLESS OTHERWISE SHOWN OR NOTED,
MODIFY TYPICAL DETAILS AS DIRECTED TO MEET SPECIAL CONDITIONS.

3. SHOP DRAWINGS WITH THE ERECTION AND PLACING OF PLUMBING MEMBERS SHALL BE SUBMITTED FOR THE
ENGINEER/DESIGNER'S APPROVAL BEFORE FABRICATION.

4. ALL PIPES SHALL BE INSTALLED AS INDICATED ON PLANS, ANY RELOCATIONS REQUIRED PROPER EXECUTION OF
OTHER TRADES SHALL BE WITH PRIOR APPROVAL OF THE ARCHITECT OR ENGINEER.
3.00m
5.PROPOSED PLUMBING UTILITIES SHALL CONFORM TO THE ACTUAL LOCATION, DEPTH AND INVERT ELEVATION OF 0.75m 0.75m 1.50m
ALL EXISTING PIPES AND STRUCTURES AS VERIFIED BY THE CONTRACTOR. INLET
0.10M THICK CONCRETE SLAB WITH
6. PLUMBING INSTALLATION SHALL NOT IMPAIR THE STRENGTH OF ANY STRUCTURAL MEMBER, COORDINATE WITH 0.50m 0.50m 0.50m
STRUCTURAL PLANS AND DETAILS. 10MMØ BARS SPACE AT O.25M.O.C
BOTHWAYS

0.50m
7. MATERIALS USED IN INSTALLATIONS SHALL BE OF APPROVED BRAND, FREE FROM ANY DEFECTS AND PASSED
THE QUALITY SET FORTH BY THE BUREAU OF PHIL. STANDARDS.

8. ALL PIPES AND UTILITIES SHALL BE ANCHORED TO A FIXED SUPPORT.

0.50m
1.50m
MANHOLE MANHOLE MANHOLE
9. ALL SLOPE FOR SEWER HORIZONTAL BRANCHES SHALL MAINTAIN A 2% SLOPE MINIMUM UNLESS OTHERWISE
SPECIFIED.

0.50m
10. SIZE OF WATER SUPPLY PIPES TO FIXTURES SHALL BE IN ACCORDANCE WITH THE MANUFACTURERS
INSTRUCTIONS.
PLAN
11. THE CONTRACTOR SHALL VERIFY ALL EXISTING UTILITIES AT SITE AND COORDINATE THE WORKS WITH THE
SEWER LINE EFFLUENT DISPOSAL POINT AND WATER LINE SERVICE CONNECTION POINT.

12. CONNECT ALL SEWER INSTALLATION TO A STANDARD SEPTIC TANK IN THE ABSENCE OF SEWER SYSTEM.
OUTLET
13. MINIMUM EARTH COVER OF 300MM SHALL BE OBSERVED FOR ALL PLUMBING PIPES.

14. CONNECT ALL PLUMBING INSTALLATIONS WITH THE APPROPRIATE FITTINGS USING PROCEDURES. SEE 3.00m
MANUFACTURERS SPECIFICATIONS.
0.75m 0.75m 1.50m
15. CONDUCT PROPER ROUGHING-INS AND/OR WATER TEST PRIOR TO POURING TO ENSURE AGAINST LEAKAGE. 0.10M THICK CONCRETE SLAB WITH
10MMØ BARS SPACE AT O.25M.O.C
16. ALL PLUMBING FIXTURES SHALL BE AS PER ARCHITECTS SPECIFICATIONS. BOTHWAYS
MANHOLE MANHOLE MANHOLE
17. ALL PLUMBING INSTALLATIONS AS INDICTED HEREIN SHALL BE DONE AS PER PLANS AND SPECIFICATIONS; NO
ALTERNATIONS SHALL BE DONE WITHOUT THE APPROVAL OF THE DESIGNER; CONSULT DESIGNER AND/OR HIS
REPRESENTATIVE ON THIS REGARD. AIRSPACE

18. ALL WATER SUPPLY PIPES SHALL BE POLYPROPYLENE RANDOM (PPR) PN 20. OUTLET

19. ALL SOIL AND WASTE PIPES AND FITTINGS SHALL BE PVC SERIES 1000. 4"THICK CHB WALL PLASTER

1.50m
FINISHED
10MMØ VERTICAL BAR SPACE LEACHING LEACHING DIGESTIVE CHAMBER
AT 0.60M. O.C. CHAMBER CHAMBER
10MMØ HORIZONTAL BAR
SPACE AT 0.60M. O.C.

10% SLOPE

0.10M THICK CONCRETE SLAB WITH


10MMØ BARS SPACE AT O.30M.O.C
BOTHWAYS

SEPTIC VAULT DETAILS


SCALE NTS

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. ROMEL V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
28
ARCHITECTURE & MASTER PLUMBER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0006122

TIN:
PTR NO. 4550198A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
DS
D1

DS
D1

DS
DS
D1
3.00

D1
DS
DS

D1 S
OW 0.40
DS
DS

0.40
1.50
IC MANHOLE MANHOLE MANHOLE
BL ER
PU EW
S

DS
V AV
LA L
WC LA
V PLAN
WC UR
WC
CB
DS
IC
BL ER ELBOW INVERT AT BAFFLE TO SLOW STORM WATER
PUSEW PERMANENT WATER SURFACE MANHOLE WITH STEPS ON EACH CHAMBER
DS ELEVATION,EXTENDED 3' BELOW SURFACE
PERMANENT WATER
IC
E PTULT SURFACE ELEVATION
S VA

IC
U BL ER
P SE W

.60
INLET
2.10

PLUMBING ISOMETRIC VIEW

4' MINIMUM
TRASH RACK OVER EVERY
OUTLET
SCALE 1:100M OPENING
4"THICK CHB WALL PLASTER
FINISHED
10MMØ VERTICAL BAR SPACE
AT 0.60M. O.C.
10MMØ HORIZONTAL BAR
SPACE AT 0.60M. O.C.

SECTION 0.10M THICK CONCRETE SLAB WITH


INSTALL A 6"Ø ORIFICE FOR EVERY 10MMØ BARS SPACE AT O.30M.O.C
15" BASIN WIDTH BOTHWAYS

OIL AND WATER SEPARATOR TANK DETAIL


SCALE NTS

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. ROMEL V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
29
ARCHITECTURE & MASTER PLUMBER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0006122

TIN:
PTR NO. 4550198A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
FROM ROOF GUTTER

DS INLET

6 "Ø PVC
4" THK CHB CEMENT
PLASTER FINISHED

SECTION

DS PUBLIC
CB
SEWER

6 " Ø PVC
4" THK CHB CEMENT
PLASTER FINISHED

DS INLET

PLAN

SYMBOLS

0.100.15
0.25
PLUMBING LAYOUT PLAN

300
SCALE 1:50
SS SOIL STACK

0.10
DS DOWNSPOUT 0.10

0.10
CB CATCH BASIN
4"Ø PVC SOIL PIPE

CATCH
SCALE
BASIN
NDTS
DETAIL DRAIN
SCALE
TRENCH
NDTS
DETAIL

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
30
ARCHITECTURE & OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO.

TIN:
PTR NO.
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] DATE ISSUED: OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
IC
BL ER
TE
R PU EW
T S
F GU
ROO CB
O M
FR

DS

PLUMBING ISOMETRIC VIEW


SCALE 1:50

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio AR. ROMEL V. ELTANAL MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
31
ARCHITECTURE & MASTER PLUMBER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0006122

TIN:
PTR NO. 4550198A
REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 412-27-326 DATE ISSUED: 01-03-2020 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE
20.00

1
4
9.00 2HP ACU 2HP ACU 2HP ACU 2HP ACU 2HP ACU 2HP ACU 2HP ACU 2HP ACU

1HP ACU

GROUND FLOOR PLAN AIRCON LAYOUT 2ND FLOOR PLAN AIRCON LAYOUT

3000KVA
GEN.SET

30.00
100MM CONCRETE SLAB WITH
9mm Ø TEMP. BARS SPACED
@ 0.60M O.C. BOTH WAYS
21.26

24KL 16KL 8KL

UNDERGROUND TANK IN
BRICK MAS. PIT WITH RCC TOP
SLAB(1:2:4) TANK SIZE TBD

FP

3HP FUEL PUMP


OUT OUT
IN IN
2
3

19.57

SITE PLAN
SCALE 1:200

PREPARED BY : SEAL THE COPYRIGHT OF THIS APPROVED BY : SHEET TITLE: DRAWN BY: EMA SHEET NO.
DRAWINGS REMAINS THE MECHANICAL
PROPERTY OF AR. EPHREM PROPOSED RMCC PETROL STATION AND DATE:
e.Aparicio ORIEL PETE R. WAGA MARX B. APARICIO WHOSE
PERMISSION MUST BE
PROJECT 2-STOREY COMMERCIAL BUILDING CONTENTS AS SHOWN
32
ARCHITECTURE & PROFESSIONAL MECHANICAL ENGINEER OBTAINED BEFORE ANY USE CADD BY: MIKE
INTERIORS OF IT CAN BE MADE.
CELL# 0997 624 3204
PRC REG. NO. 0002709

TIN:
PTR NO. 4540252

DATE ISSUED: 01-06-2020


REPUBLIC ACT 9266
LOCATION POBLACION, DANGCAGAN, BUKIDNON, MIN. PH. RMCC GROUP OF COMPANIES DATE: 10-26-2020 32
EMAIL:[email protected] 132 291 781 OWNER RMCC GROUP OF COMPANIES OWNER'S SIGNATURE

You might also like