0% found this document useful (0 votes)
171 views2 pages

HZ 56 AC/DC Current Probe: Accessories For Oscilloscopes

The document describes various accessories for oscilloscopes, including current probes, coaxial cables, wideband probes, interface devices, and a scope tester. The HZ 56 AC/DC current probe measures current from 5mA to 30A with ±1% accuracy using Hall effect technology. The HO79-6 interface supports GPIB, RS-232, and parallel ports to transfer oscilloscope data to peripheral devices. The HZ60-3 scope tester accurately tests important oscilloscope characteristics using 7 crystal-controlled frequencies from 1Hz to 1MHz.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
171 views2 pages

HZ 56 AC/DC Current Probe: Accessories For Oscilloscopes

The document describes various accessories for oscilloscopes, including current probes, coaxial cables, wideband probes, interface devices, and a scope tester. The HZ 56 AC/DC current probe measures current from 5mA to 30A with ±1% accuracy using Hall effect technology. The HO79-6 interface supports GPIB, RS-232, and parallel ports to transfer oscilloscope data to peripheral devices. The HZ60-3 scope tester accurately tests important oscilloscope characteristics using 7 crystal-controlled frequencies from 1Hz to 1MHz.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

ACCESSORIES FOR OSCILLOSCOPES

HZ 56 AC/DC Current Probe


Utilising Hall Effect technology to provide a broad frequency response, the
probe will accurately measure AC, DC and complex waveforms. The compact
clip-on design conforms to the IEC1010 safety standard and allows non-
intrusive measurement of current from 5mA to 30A peak to an accuracy of
±1%. The probe gives a voltage output directly proportional to the measured
current which is compatible with a wide range of measuring instruments.

Specifications:
Current range: 20A DC / 30A AC Frequency range: DC-100kHz
Accuracy: ± 1% ± 2mA Resolution: ±1mA
Dielectric strength: 3.7kV, 50Hz, 1min. Load impedance: >100kΩ
Output sensitivity: 100mV/A Divers: BNC-cable, 2m.

Sparepart Kit HZ 40
HZ38

HZ 72/S/L
HZ36

HZ 33 Accessories
HZ26 HZ51
supplied

HZ27 HZ52
HZ 32
HZ20

HZ 34S HZ53
HZ22

HZ23
HZ 31 HZ54

HZ24

HZ20 Adaptor BNC to 4mm binding posts


HZ22 50Ω BNC Feed-through termination 1GHz, 1W
HZ23 Attenuator 2:1, BNC male to BNC female, for oscilloscope service only.
HZ24 Set of 4 BNC 50Ω attenuators; 3/6/10/20dB; 1GHz, 1W, incl. 1x HZ22
HZ27 Adaptor BNC female to BNC female
HZ28 Adaptor BNC male to 2 BNC female
Test Cables
HZ31 Coaxial cable BNC/BNC, 50Ω, 40 inch, elbow
HZ32 Test cable BNC to single stacking banana plugs; 40 inch
HZ33 Coaxial cable BNC/BNC, 50Ω, 20 inch
HZ33S Coaxial cable BNC/BNC, 50Ω, 20 inch, insulated
HZ34 Coaxial cable BNC/BNC, 50Ω, 40 inch
HZ34S Coaxial cable BNC/BNC, 50Ω, 40 inch, insulated
HZ72S IEEE-488-Bus-Cable, 40 inch. double shielded
HZ72L IEEE-488-Bus-Cable, 60 inch, double shielded
Wide Band Probes with RF alignment HZ97 Carrying Case for
Attenuation Max. HM303, 304, 305, 604-3, 1004 and
Type Ratio Bandwidth Risetime Input Impedance Input Voltage HM5005 / 6 / 10.
HZ36 1:1/10:1 10/100MHz <35/3.5ns 1/10MΩII57/12pF (10:1) 600V (DC+peak AC) The carrying case provides protection
HZ51 10:1 150MHz <2.4ns 10MΩII12pF 600V (DC+peak AC) during transportation of an oscil-
HZ52 10:1 250MHz <1.4ns 10MΩII10pF 600V (DC+peak AC) loscope. It is made of a durable vinyl-
HZ53 100:1 100MHz <3.5ns 100MΩII4.5pF 1200V (DC+peak AC) coated material that is designed to
HZ54 1:1/10:1 10/150MHz <35/2.4ns 1/10MΩII57/12pF (10:1) 600V (DC+peak AC) withstand the stress and wear and
tear of field use.
Special Probes
HZ38 Demodulator Probe 0.1 - 500MHz max. 200V (DC)
HZ47 Viewing Hood for Oscilloscopes HM205, 408, 604-1+2, 1005 and 1007 Subject to change without notice 05/99

14

Farbe S.14 Seitenhöhe 285 von oben


INTERFACE FOR OSCILLOSCOPES

Multifunction Interface HO79-6 HO79-6 supports: In its TALK-ONLY configuration the HO79-6
acts:
GPIB (IEEE-488) – RS232C – Parallel 1. as transmitting device for listen-only
(Centronics) instruments (for example: HPGL plotters)
2. as automatic controller when the os-
The HO79-6 processes commands (accor- cilloscope is being operated in SINGLE mode.
ding to the SCPI standard) that will be received In case of a trigger event the oscilloscope
via the GPIB or the RS232C port. In its digitizes the signal(s). Then the HO79-6
stand alone mode the HO79-6 is able to trans- transfers the data as configured and resets the
mit data to an attached device after pressing oscilloscope again.
the START button, for example to print a
RS 232C - bidirectional -
graphic document.
This port is used to transfer data and com-
The following formats are supported for all mands from/to the serial interface of a PC. The
ports: HO79-6 supports transfer rates from 1200 Bd
Designed for HAMEG Analog/Digital to 38400 Bd.
Oscilloscopes with Serial Interface PostScript - HPGL - PCL - EPSON Parallel - unidirectional -
This port is used for printers with a Cen-
The HO79-6 interface enables the user to GPIB (IEEE-488) - bidirectional -
tronics type cable.
transfer data from the oscilloscope to peri- In this mode the adapter can be configured
pheral devices for documentation purposes as normal BUS or as TALK-ONLY DEVICE. Attachment to the oscilloscope
and to transmit reference signals to the
oscilloscope in its digital mode. Additionally the The HO79-6 accepts commands from any When the HO79-6 is fastened to the back
attached oscilloscope can be remotely GPIB controller and executes them. In this case panel of the oscilloscope the connections for
controlled via the HO79-6 in its digital as well the HO79-6 has to be configured as BUS the data transfer as well as for the power
as in its analog operating mode. DEVICE. supply will be built up automatically.

Scope Tester HZ60-3 than 1%, and can be recalibrated at any time
using any DMM. To prevent power line inter-
The HZ60-3 is currently the world's only ference, the Scope Tester is powered by 4
reasonably priced instrument for accurate AA-type batteries, which are automatically
and reliable testing of the most important switched off after three minutes.
characteristics of oscilloscopes and pro- 7 crystal-controlled frequencies,
bes. In view of the fact that many oscillo-
1-10-100Hz, 1-10-100kHz and 1MHz.
scopes actually have poor signal transfer
DC calibration voltage.
characteristics, this tester is an indispensable
piece of equipment. In addition, such an Rise time: typical <1ns.
instrument is an absolute must for RF adjust- 3 output voltages: 25mVpp at 50Ω
ment of high frequency probes or for matching termination, 0.25Vpp and 2.5Vppo.c.
probes to the oscilloscope input. Battery operated with 4x1.5V (AA)
For all tests, the HZ60-3 generates precise incl. 3 min. economizing circuit
square-wave signals at 7 crystal-controlled Dimensions: 125x80x42mm.
frequencies with a rise time of approx. 1ns.
This permits precise measurements of the
Accessories supplied
horizontal deflection coefficients of oscil- Operating instructions, 50Ω-cable,
precise 1MHz signal 1MHz signal with improperly
from tester HZ60 adjusted probe loscopes. The amplitude accuracy is better 50Ω-through termination

Component Tester HZ65 of current through any components. It is also


very important to disconnect common ground,
The Component Tester HZ65 permits non- because any additional connections between
destructive testing of semiconductors, components and the tester may cause incorrect
resistors, capacitors, and inductors, either pattern display. Connects to all Oscilloscopes
individually or in-circuit. The resulting display
on the scope screen will show the characte-
ristic voltage/current diagram of the com-
ponent under test, enabling its functionality to Test voltage: approx. 8.2Vrms
be interpreted. Two 3-point sockets are pro-
Test currents: max. 3.7-37-320mArms
vided for testing transistors, permitting selec-
tion of any two contacts. Components with Power supply: 115V and 230V ±10%
larger diameter leads and ICs are connected Power consumption: max. 4 Watt.
using two test leads. The test voltage and
current are limited, so that no components can Dimensions: 125x80x42mm.
be damaged.
It is possible to rapidly locate faults in Subject to change without notice 05/96
complex circuits by comparing test patterns of
a known good circuit and the circuit under test. Accessories supplied
Before starting the test, all circuits must be Operating instructions,
Transistor junction parallel connection
base / emitter diode/resistor disconnected from power to prevent passage 2 test leads (red and black)

15

Seitenhöhe 285 von oben Farbe S.15