Microstep: System Manual
Microstep: System Manual
Manual Content
Microstep 1. Foreword
2. Overview
SH-HC30
Flame / Plasma Cutting Torch 3. Installation
Height Controller
4. Fast Operation
6. Operating guide
7. Control Panel
8. Troubleshooting
9. Initial positioning
1
SH-HC30 Height Controller System Manual
Disclaimer
We already made a consistency inspect between the content of the printed file and the hardware & software
described. We can’t guarantee absolute accuracy due to the inaccuracy can’t be eliminated completely. We
will check the information in the file regularly and make some necessary amendments afterwards. We are
pleased to accept any suggestions on the amendments. The company will reserve all the rights to make
some amends technically or on the base of amended files.
2
SH-HC30 Height Controller System Manual
Contents
1. Preface .................................................................................................................................... 1
1.1 Purpose.............................................................................................................................. 1
1.4 Terms................................................................................................................................. 2
2. Overview ................................................................................................................................. 3
3. Installation ............................................................................................................................. 5
4. Quick Operation Guide for Capacitance and Arc Voltage height Controller.......................... 17
4.1 The control operation of electrical operation panel: (external switch mode) ................. 17
4.2 SH-2002AH/SH-2200H CNC system output interface operation (I / O control mode) ... 18
4.3 The communication interface of the CNC system is used to complete the operation
(RS232 communication mode) .............................................................................................. 19
5 Operating Guide..................................................................................................................... 21
6. Debugging............................................................................................................................. 21
3
SH-HC30 Height Controller System Manual
8 Troubleshooting..................................................................................................................... 25
4
SH-HC30 Height Controller System Manual
1. Preface
Either flame cutting or plasma cutting mode the stability of the distance (height) between the cutting torch
and the cutting board in cutting is essential, which will directly affect the cutting speed and cutting quality.
1.1 Purpose
SH-HC30 flame / plasma cutting torch height controller is the automatic control module for cutting torch
height with the integration of mechanical increase and electric control specially designed for portable flame
and plasma cutting machine, and another new product in the aspect of industrial automation control of
Beijing Start Microstep Control Technology Co., Ltd.
SH-HC30 flame / plasma cutting torch height controller is easy to use; debugging is convenient; and the
price is low; it inherits the characteristics of Microstep products: "The performance of imported product;
Domestic price." It is the ideal accessory product for welding and cutting equipment manufacturers.
Please comply with the actual instrument if there is any discrepancy between the
SH-HC30 flame / plasma cutting torch height controller and the content of the
manual. We won’t inform you particularly if some amendments about the product
and its accessories are made. If you want to know more updated content, please
go to our website http://www.startsh.com, or call Beijing Start Microstep Control
Technology Co., Ltd.
Page 1
SH-HC30 Height Controller System Manual
Please read the safety warning and attentions to avoid any accidents due to
incorrect operations.
Please operate the machines strictly following the manual and its detailed
instructions before you install and use this machine.
All the responsibilities will be undertaken by the users if any particular illegal
utilization of SH-HC30 flame / plasma cutting torch height controller or manual is
made for it doesn’t represent our position and we refuse to admit the legal
responsibility.
The safety warning is to avoid any accidents to the human body or properties.
For any quality problems during the utilization of the SH-HC30 flame / plasma
cutting torch height controller, the customers can call the service center of our
company or authorized agents, distributors to get service and help.
It’s not allowed to copy, transmit or utilize any content of this manual without the
specific permission. Any offenders will undertake all the responsibilities for the
loss.
1.3 Warning
Please read and strictly comply with the following instructions before operating the product to reach the
design control accuracy of product and avoid any damage and accident.
Installation must be carried out by technical personnel of related industry or
having relevant experiences.
Please thoroughly read the instructions before installation.
Confirm that the selected power supply complies with the required specifications.
Installation, inserting and pulling of plugs are prohibited when the current is
switched on.
Keep away from heat for the installation position.
The controller shell must be grounded well to avoid electric shock or affecting the
controller.
The cutting board must be grounded well, and maintain a good grounding with
the controller shell in order to ensure the accuracy of height control.
!
Note: If the controller shell and the cutting board are not grounded well, the height controller will not work
normally.
Take care when transporting and never make some fierce collision or tremble for
damage may occur.
Please don’t disconnect the SH-HC30 flame / plasma cutting torch height
controller or change its internal construction for any accidents or fault may occur.
1.4 Terms
Page 2
SH-HC30 Height Controller System Manual
One key height calibration: when the capacitance height measurement is
adopted, the specific inductive capacity between the capacitance detection ring
and the cutting board may affect the accuracy of height measurement due to
temperature, pressure, humidity, gas composition and many other factors on site.
In addition, the serious non-linear relationship exists between capacitance value
and height value. Our company has developed the intelligent program of "a key
height calibration". You only need to press a key on site, you can set various
factors of change automatically. And within 3-30mm, the display and control of
high accuracy, high precision and high linearity are realized.
High speed zone: When the difference between the actual height and the set
height is bigger, in order to reach the set value at the fastest speed, the cutting
head advances for the set value at the highest speed; this zone is called high
speed zone.
Speed Regulating Zone: When the cutting head reaches the set value at high
speed, severe oscillation may be caused so that the height control is unstable. In
order to achieve a smooth transition, the speed regulating zone is set. This zone
is located between the high-speed zone and dead zone. In this zone, when it is
farther away from the set value, the cutting head moves at higher speed; if not,
at a lower speed. The range value in this zone may be set. When it is too big, the
transition is smooth, but the track time is too long; when it is too small, the
tracking is conducted in time, but oscillation may be caused easily.
Dead zone: When the cutting head is within certain height value, the height of
the cutting head will not be adjusted any more. The range is called dead zone.
When the dead-zone value is too large, the control precision is too low; when it is
too small, the cutting head may oscillate up and down easily. The appropriate
value of dead zone not only can guarantee the control precision but also do not
generate oscillation.
E-mail:[email protected]
2. Overview
Page 3
SH-HC30 Height Controller System Manual
Stepper motor instead of the traditional DC motor
SH-HC30 flame / plasma cutting torch height controller uses the unique stepper
motor control technology of Start Microstep Company. It subverts the traditional DC
motor height control mode and makes it become fast and smooth, and the life of the
product is increased greatly.
The height of cutting nozzle is displayed directly in the mode of
Page 4
SH-HC30 Height Controller System Manual
Total weight of Arc Voltage height: 1.645kg
Detection system: capacitance-type detector, arc voltage height detector
3. Installation
The name and position of relevant components of the height controller are shown in Figure 3-1.
Among them, capacitive sensor connecting components are only added in flame .
Lift stepper
Standard high frequency
Detector ring
Operating display
panel
Cutting torch holder
Detector ring holder
Flame cutting torch
Detector ring
Figure 3-1 The position, name and function of various components of controller
6 screw holes M6 on the back of the height controller are used to fix the box body
to the support. Their position and size are shown in Figure 3-2.
Page 5
SH-HC30 Height Controller System Manual
Note:
Pay attention to the depth of six mounting
holes in installation so as not to affect the
stroke.
2. The distance from the shell of the height
controller to the interior should be less than
8mm, namely the length inserting into the
interior of the height controller shell must not
exceed 8mm.
Figure 3-2 Position for installation of screw holes on the back of the controller
Left view installation drawing of the height controller and related dimensions, as shown in Figure 3-3.
Back view installation drawing of the height controller and related dimensions, as shown in Figure 3-4.
Page 6
SH-HC30 Height Controller System Manual
Figure 3-5 Installation diagram of the connecting components of the height controller
Page 7
SH-HC30 Height Controller System Manual
K2
Manual rise
K3
Manual falling
Ground
The electrical installation of capacitive detection height controller is shown in Figure 3-6.
The high-frequency cables and plugs are special parts. The high-frequency cables of 1000mm can
be configured according to different demands.
The connection to height control (15-pin connector) and the numerical control system (25-pin
connector) may be made by the user. The connection mode is shown in Figure 3-7. For the detailed
pin definition of 15-pin and 25-pin see Table 3-1 and Table 3-2.
Page 8
SH-HC30 Height Controller System Manual
Figure 3‐6 capacitive controller electrical installation diagram
Note: The diameter of 24 V power wire and ground wire should be larger than 0.75 mm2
Manual rise
Manual falling
Ground
Page 9
SH-HC30 Height Controller System Manual
Table 3-1 25-pin connector of numerical control system for the pin definition of the height control system
6 Power Supply Power supply 24V ground, height controller power supply
12, 13 Power Supply Power supply 24 V positive, height controller power supply
24, 25 Power Supply Power supply 24 V positive, height controller power supply
Note: 25-pin plugs of the numerical control system that do not list the pin serial number will not be used.
Note: 15-pin plugs of the numerical control system that do not list the pin serial
number will not be used.
The electrical installation of arc voltage detection-type height controller is shown in Figure 3-8.
The cables connecting to height control (15-pin connector), numerical control system (25-pin connector)
and voltage divider board (9-pin connector) are made by the user. For the pin definition of 15-pin,
Page 10
SH-HC30 Height Controller System Manual
25-pin connector and 9-pin connector see Table 3-1, Table 3-2 and Table 3-3
Table 3-3 The pin definition of 9-pin connector of voltage divider board
6 Output Arc voltage signal, height signal of the plasma cutting nozzle
Page 11
SH-HC30 Height Controller System Manual
Note: Those that do not list the pin serial number will not be used.
9‐pin connector of voltage divider board
15‐pin connector of height 25‐pin connector of numerical control system
Figure 3-9 Wiring diagrams of arc-type height controller, voltage divider board and numerical control system
Note: The wire diameter of 24V power cord and ground wire should be greater than 0.5 square millimeter.
Page 12
SH-HC30 Height Controller System Manual
15-pin
High-frequen
分压板 9 芯接头
25pin
Page 13
SH-HC30 Height Controller System Manual
Automatic open
24V GND
This figure is kept on standby – automatic connecting method by using arc voltage and capacitance
(RS232 control)
The control mode of communication interface of CNC system is conducting the software debugging
The voltage divider board is to reduce the voltage after arc starting of plasma cutting torch in a certain
proportion, and is separated and converted to the functional module reflecting the low-voltage signal of
cutting nozzle and cutting board. It is the indispensable accessory in the height monitoring and control
of plasma cutting. The voltage dividing ratio of the voltage divider board of standard configuration is 50:
1.
The description of various interfaces of the voltage divider board is shown in Figure 3-10.
Page 14
SH-HC30 Height Controller System Manual
2 Power supply Power supply 24V ground, height controller power supply
5 Power supply Power supply 24V ground, height controller power supply
6 Output Arc voltage signal, the height signal of plasma cutting nozzle
9 Power supply Power supply 24V positive, height controller power supply
Page 15
SH-HC30 Height Controller System Manual
Note: Those without pin number will not be used.
Note: push the orange button inside and insert the stripped cable into the wiring hole and then release.
The voltage divider board may choose the installation position as required, but note: J1 interface is
low-voltage signal; J2 is the high-voltage signal. In order to prevent the interference of
high-pressure and high-frequency signals on the low-voltage signal and improve the stability of the
system, the wire laying of J1 and J2 should be carried out independently.
Page 16
SH-HC30 Height Controller System Manual
switch mode)
For the wiring of electrical connection of capacitance height control see the "Electrical
Connection" of section 3.2
For the wiring of electrical connection of arc voltage height control see the "Electrical
Connection" of section 3.3
Operation steps are as follows:
1. The automatic / manual control switch is set to manual mode.
Cutting gun control
Automatic Rise fall
The automatic / manual
control switch is set to
manual mode
Manual
2.The direction switch of the cutting gun is used to adjust its rise and fall .
Manual
Page 17
SH-HC30 Height Controller System Manual
Now the mechanical lift device of the height controller realizes the automatic height control. If the height of
the cutting gun is inappropriate, repeat the above steps 1-3. In automatic mode, the up / down switch of the
cutting gun does not work.
O control mode)
For the wiring of electrical connection of capacitance height control see the
"Electrical Connection" of section 3.2
For the wiring of electrical connection of arc voltage height control see the
"Electrical Connection" of section 3.3.
The operation steps are as follows
1. Adjust the rise and fall of cutting gun to a suitable height directly by pressing the keys for rise and fall of
the cutting gun on CNC panel.
KEY USB
Page 18
SH-HC30 Height Controller System Manual
Usually, I / O of the numerical control system is in the manual control mode of the height controller. When
the processing starts, I / O of the numerical control system converts to the automatic control mode of the
height controller. Now the mechanical lifting device of the height controller realizes the automatic height
control.
The function is being developed. For the final functions see the additional remarks after the functions are
completed.
The flow is
Figure 4-1 The operation flow using or needing the replacement of detection mode for the first time
Page 19
SH-HC30 Height Controller System Manual
auto-detection of "manual
/auto" status
Yes No
Manual
When the manual rise signal The cutting torch adjusts the
is low level, the cutting height automatically
torch moves upward according to the set height
Page 20
SH-HC30 Height Controller System Manual
5. Operating Guide
After turn-on, the height controller has three states: manual, automatic and parameter editing states.
In the manual or automatic mode, press the key “Enter” for a long time, enter the parameter editing
state. Click the key “Enter” in the editing state, you can exit to the manual or automatic state. The
exited state depends on the state before entering.
In the editing state, press the function key, switch the edited parameters circularly. The switching
sequence is: H (upper limit value) → L (lower limit value) → A (set value of height) → E (dead-zone
value) → d (speed regulating zone value) → C (detector mode selection) → b (non-board reduction
parameters) → H (upper limit value). (See 7.3)
Click the up arrow, the selected parameter value plus 1 (for the selective range of parameter values see
7.1).
Click the down arrow, the selected parameter value minus 1 (for the selective range of parameter values
see 7.1).
Manual / automatic signal: at low level, the controller is in the automatic state.
In the automatic state, the controller controls the cutting head automatically according to the set height
by the user.
Press the key "↑" on the operation panel; the set value of height plus 1; hold it, plus 1 continuously.
Press the key“↓” on the operation panel; the set value of height minus 1; hold it, minus 1 continuously.
6. Debugging
The capacitance height measurement is to detect the distance through the capacitance between the
capacitance detection ring and the cutting board, namely, the height measurement mode, thereby to
achieve the height control.
Page 21
SH-HC30 Height Controller System Manual
When the capacitive height measurement is adopted, the specific inductive capacity (SIC) between the
capacitance detection ring and the cutting board may affect the height measurement accuracy due to the
temperature, pressure, humidity, gas composition and many other factors on site. In addition, the serious
non-linear relationship exists between the capacitance value and the height value. Our company has
developed the intelligent program of "a key height calibration ". On site you only need to press a key, you
can set various change factors automatically on site and realize the display and control of high accuracy, high
precision and high linearity within 3-30mm.
In the following situations, the height calibration is needed.
1. When the equipment is used for the first time;
2. When the use environment of equipment changes;
3. When you find that the actual height of capacitance detection ring is not consistent with its display height.
Because "a key height calibration" is very simple, you only need to press a key, the users may calibrate at
any time.
Check: the circular ring at the bottom of capacitance detection ring must be parallel to the cutting
board.
Turn on the cutting torch height controller.
Set the detector mode as the capacitance detector mode (for the method see 7.3).
In manual mode, the cutting nozzle is adjusted to be connected with the cutting board.
Press the key "down arrow" on the height control panel for about two seconds "; a key height
calibration” starts automatically, as follows:
1.Rise to about 30mm high in five steps;
2. And then fall to about 10mm from the cutting board and stop;
3. All the calibration is completed.
The initial debugging is finished.
For the height control operation see 5.2 and5.3.
7. Controller Panel
There are display and keys on the height controller panel. Through the panel operation, you can modify
relevant parameters and monitor operation status.
Set value (A: Accuracy Height): the expectation value of the space (height) between the cutting nozzle
and the cutting board, set by the user. For the set range and factory value see Table 7-1.
Dead zone value (E: Error Area): When the actual height is A ± E, the cutting torch height is not
adjusted any more (see 1.4). For the set range and factory value see Table 7-1
Speed regulating zone (d: Down Speed Area): the speed regulating zone is between AEd ~ AE, and A
+ E ~ A + E + d (see 1.4). For the set range and factory value see Table 7-1.
High limit place (H: High Limit): When the cutting torch position is higher than the set value, display
alarm, and moving-up stops. For the set range and factory value see Table 7-1.
Low limit place (L: Low Limit): When the cutting torch is lower than the set value, display alarm, and
moving-down stops. For the set range and factory value see Table 7-1.
Page 22
SH-HC30 Height Controller System Manual
Selection of detector (C: capacitance): 0 is the arc voltage detection; 1 is capacitive detection. For the
set range and factory value see Table 7-1.
No board drop parameter (b):
In the capacitive detection mode, when the detected height is higher than value b, the cutting torch
stops; when the height returns to the value below it, the automatic height control continues;
In the arc voltage detection mode, when it falls manually, it encounters the zero signal, the cutting torch
rises to b mm in the opposite direction. For the set range and factory value see Table 7-1.
H L A E d C b
Set range
100~300 10~40 20~200V 0~20 0~100 0~1 0~50
(V)
Arc voltage
Factory
280 10 80 3 5 1 5
value(V)
Set range
20.0~30.0 3.0~10.0 6.0~25.0 0.0~4.0 0.0~4.0 0~1 2.0~30.0
(mm)
Capacitance
Factory
value 25.0 4.0 10.0 0. 3 2. 0 1 25.0
(mm)
Display
Up arrow
Enter key
function
down arrow
Page 23
SH-HC30 Height Controller System Manual
Enter key: enter or exit the editing state.
Function key: in the manual state, implement the function of “a key height
calibration”; in the editing state, switch the current editing parameters.
Up arrow: in manual and automatic state, the set height value plus 1; in the
editing state, the current parameter plus one.
Down arrow: in manual and automatic state, the set height value minus 1; in the
editing state, the current parameter minus 1.
Display: the display functions are as follows:
1. Manual operation status: Display detector mode, operation status, set value of
height.
2. Automatic operational state: display detector mode, running state, the current
height value.
3. Editing parameter status: Display the editing parameter names and the
corresponding editing parameter values.
Manual operation state: The first one displays the detection mode; the second one
displays the operation state; the last 3 digits display the set value of height.
The first one: C: the capacitance detector mode, U: the arc voltage detector mode.
The second one: no operation, flash between and ; manual rising: ; manual
falling: .
The last 3 digits: in the capacitance mode, a decimal; unit: of mm; in arc voltage
mode, there is no decimal place; unit: V.
Automatic operation state: The first one displays the detection mode (as shown
above); the second one displays the operation state; the last 3 digits display the set
value of height (as shown above). The second one is described as follows:
When is the fixed display, the cutting torch is adjusted up at high speed.
When is the flashing display, the regulating speed of the cutting torch is
increased.
When is the fixed display, the cutting torch is adjusted down at high
speed.
When is the flashing display, the regulating speed of the cutting torch is
reduced.
When is the flashing display, the cutting torch is adjusted to the place.
When the last 3 digits are and the height value flashes, it is the high
alarm
When the last 3 digits are and the height value flashes, it is the low
alarm
When the last 4 digits are and display, it is the upper limit position.
When the last 4 digits are and display, it is the lower limit position.
Editing parameter status: The first one displays the parameter name; the second one
displays the equal sign ; the last 3 digits display the parameter value in the
flashing mode. In the capacitance mode, there is a digit after decimal; unit: mm; in
Page 24
SH-HC30 Height Controller System Manual
arc voltage mode, there is no decimal point position; unit: V. The first one is
described as follows:
H: the upper limit value. When the height is larger than this value, it is the
high alarm. The cutting torch can only move down and cannot move up.
L: lower limit value. When the height is lower than this value, it is the low
alarm. The cutting torch can only move up and cannot move down.
A: the set value of height; in the automatic mode, this value is used as the
given value to adjust height automatically.
E: Dead zone value (see 7.1).
D: Speed regulating zone value (see 7.1).
C: selection of detector mode (see 7.1).
b: No board falling parameter value (see 7.1)
8. Troubleshooting
For the common faults, inspection methods and corrective measures see Table 8-1.
Table 8-1
Upper limit The running exceeds the upper limit value of Check the limit switch in
alarm machinery high position
Lower limit The running exceeds the lower limit value of Check the limit switch in
alarm machinery low position
Instable signal Whether the cutting board is grounded reliably Grounded firmly
Page 25
SH-HC30 Height Controller System Manual
The impact position switch is set in the height controller. When the cutting gun moves down and collides
with the cut workpiece, the internal switch is turned on without the need of special cutting gun and
"protection cap". Electrical loop must not be formed between the "protection cap" and the workpiece. This
approach applies to any plasma cutting gun.
How to use the positioning function: in the plasma mode, the signal of "manual down" of the external
control interface is valid. When the cutting gun moves down and collides with the steel plate, the internal
switch is turned on. It returns up to a certain height by automatic control of the height controller, and then
positioning is completed.
Parameter value B is the positioning height, unit: mm; note when detection collision occurs, overmuch
walking and certain deformation of workpieces and cantilever occur, so value B is generally set within
5-12mm.
9.3 Process
This function does not require additional relevant processes and instructions by the numerical control
system. It only needs to extend the time for falling of the cutting gun. Generally, the time for the falling of
the cutting gun is longer than its rise; 2-6 seconds are OK.
Before NC implements the perforating process, the cutting gun will rise or fall. Because the falling time will
be longer than that of rise, and then the cutting nozzle may collide with the workpiece, at this time, the
height controller can detect the collided workpiece and will return up to a certain distance immediately, thus
the initial positioning is realized. Note even if the falling signal for the cutting gun has not been removed by
NC system, the cutting torch will not continue to fall, waiting for falling delay of the cutting gun of NC to end.
Why special attention should be paid to the collection of arc voltage? Because even
the plasma power of different manufacturers cuts in the same environment, the arc
column voltage is not necessarily the same. Fill in parameters A with the test results
(see control parameters 7.1). If the value A is not tested, the current value is smaller
than the current actual voltage for plasma power cutting, then the plasma cutting
gun will fall rapidly until it collides with the workpiece in automatic cutting, if not, it
will always rise until the arc breaks.
For the new plasma power that is newly used and is not familiar, when it is equipped
with the height controller for the first time, the actual starting arc testing must be
made for the actual arc voltage of the plasma power supply. The normative power
supply may be based on the "cutting speed chart" provided by the supporting
instruction book by plasma power supply.
Simple test method: adjust the distance of the cutting torch and steel plate to the
appropriate value manually (according to the power process requirements). In the
Page 26
SH-HC30 Height Controller System Manual
manual mode of plasma, the height controller carries out the manual starting arc
perforation, after perforation, the cutting gun moves (through the numerical control
system ) for actual cutting, at this time, the value on the nixie tube display of the
height controller is the actual arc voltage of the plasma power supply in the current
environment.
M14/M15 switch for rising of cutting gun, M14 (on), M15 (off)
M16/M17 switch for falling of cutting gun, M16 (on), M17 (off)
M38/M39 automatic / manual switch of the height controller M38 (auto) M39 (manual)
Page 27
SH-HC30 Height Controller System Manual
M08
1. Close the cutting oxygen (M13);
2. Turn off the height controller (M39);
3. The cutting gun rises (M70);
The plasma cutting operation sequence is as follows:
M08
1. Turn off the arc voltage switch;
2. Turn off the height controller (M39);
3. The cutting gun rises (M70).
M50 perforation action:
1. The cutting gun rises (M72); when the plasma operation is carried out, there is no such action;
2. Open the cutting oxygen (M12); or plasma starting arc starts and the signal of "arc voltage success" is
detected.
3. The cutting gun falls (M73), when the plasma operation is carried out, there is no such action;
4. Turn on the height controller (M38)
M70 Fixed cycle of the cutting gun rise:
It is used when the procedure starts and the cutting procedure of a stage ends, the cutting gun is lifted so
that it can move to the next cutting position quickly. Operation sequence: turn on the cutting gun rise switch
(M14), cutting gun rise delay is delayed; turn off the switch for the cutting gun rise (M15).
M71 Fixed cycle of cutting gun fall:
It is used before perforation. Its action is contrary to M70, but the value is smaller, because of the action of
gravity, falling is faster than rising. Operation sequence: turn on the switch of cutting gun fall (M16), cutting
gun fall delay is delayed, turn off the switch of the cutting gun fall (M17).
M72 Perforation cutting gun rise cycle:
It is used after preheating. The cutting gun is lifted to a certain extent. Avoid that sprayed steel slag blocks
the muzzle of the cutting gun when the cutting oxygen is opened. Operation sequence: turn on the switch of
the cutting gun rise (M14); perforation cutting gun rise delay is delayed; turn off the switch of cutting gun
rise (M15).
M73 Falling cycle of perforation cutting gun:
It is used after the preheating. After the implementation of M72, open the cutting oxygen, the cutting gun is
placed in the cutting position, the reverse action of M72, but the value is smaller. Because of the action of
gravity, falling is faster than rising.
Operation sequence: turn on the switch of the cutting gun (M16); the perforation cutting gun delay is
delayed; turn off the switch of the cutting gun (M17).
M75 Cutting gun positioning delay:
When the plasma gun is positioned, first the cutting gun falls (M16), when it comes to the lower limit place
(see the input port XXW 8), the falling of the cutting gun stops (M17). Then, the cutting gun rise is started
(M14); after the cutting gun positioning delay, the rising of the cutting gun stops (M15);
In order to make the users be far away from the cutting site in operation, and make them use it easily,
simply and intuitively, our company provides the users with the dedicated remote controller, as shown in
Figure X-1.
Page 28
SH-HC30 Height Controller System Manual
Graphic model of remote controller
Figure X‐1 Outside view of the height adjustment remote controller
The remote controller uses the computer core design and can implement the information communication
RS232 with the master controller. The adjustment of the height and the sensitivity adopts the simple knob
design so that it has the operation conveniences of analog circuit and accuracy and reliability of digital
circuit.
Wiring unit 1 Back terminal of the remote controller
Wiring unit 2
DB15 plug of height controller
The functions of the back terminal of the height remote controller are shown in Table X-1.
Page 30
SH-HC30 Height Controller System Manual
Table X-1 Function definition of the back terminal of the controller
9 Power supply Power supply 24V ground, height controller power supply
15 Power supply Power supply 24V positive, height controller power supply
16 Power supply Power supply 24V ground, height controller power supply
96X48mm
48
48mm
45
12
68
96mm
Page 31