100% found this document useful (1 vote)
311 views

Parapet Capacity

This document contains design calculations for the superstructure of Junction 3A Bridge 23/MB/3AA, specifically for the transverse deck slab and parapet post capacity. It analyzes the required loading and provides the dimensions, reinforcement, material properties, and calculations for the moment and shear capacities of a 3 meter parapet panel strip. The calculations show that the provided reinforcement yields a moment capacity of 518 kN.m and a shear capacity of 587 kN, both exceeding the respective nominal design loads of 450 kN.m and 495 kN.

Uploaded by

Jemicah Yumena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
100% found this document useful (1 vote)
311 views

Parapet Capacity

This document contains design calculations for the superstructure of Junction 3A Bridge 23/MB/3AA, specifically for the transverse deck slab and parapet post capacity. It analyzes the required loading and provides the dimensions, reinforcement, material properties, and calculations for the moment and shear capacities of a 3 meter parapet panel strip. The calculations show that the provided reinforcement yields a moment capacity of 518 kN.m and a shear capacity of 587 kN, both exceeding the respective nominal design loads of 450 kN.m and 495 kN.

Uploaded by

Jemicah Yumena
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

DOCUMENT No. (Project/Doc) SHEET No.

EXW-P023-3332-SE-QBJ-CC-00113

SUBJECT
JUNCTION 3A BRIDGE 23/MB/3AA DESIGN CALCULATIONS
SUPERSTRUCTURE

Reference CALCULATIONS OUTPUT

2.2 TRANSVERSE DECK SLAB

2.2.1 PARAPET POST CAPACITY CHECK

Parapet Post Concrete Strength, fcu 50 MPa


Reinforcement Characteristic Strength, fy 500 MPa
Provided Reinforcement B16 - 150

Loading:

Parapet Type 2: High Level of Containment


Length per Parapet panel, L 3.0 m.
Height of Parapet, H 1.5 m.

Design Load:
Nominal Moment, (180 + 40L)*H 450 kN.m
Nominal Shear, (90 + 50H)*L 495 kN

Parapet Section:
Breadth, b 3000 mm.
Height, h 370 mm.
DOCUMENT No. (Project/Doc) SHEET No.

EXW-P023-3332-SE-QBJ-CC-00113

SUBJECT
JUNCTION 3A BRIDGE 23/MB/3AA DESIGN CALCULATIONS
SUPERSTRUCTURE

Reference CALCULATIONS OUTPUT


DOCUMENT No. (Project/Doc) SHEET No.

EXW-P023-3332-SE-QBJ-CC-00113

SUBJECT
JUNCTION 3A BRIDGE 23/MB/3AA DESIGN CALCULATIONS
SUPERSTRUCTURE

Reference CALCULATIONS OUTPUT

Moment Capacity (3m. Strip):


Longitudinal Bar Diameter, Ø 16 mm.
Total number of longitudinal bars, n 20
Area of Reinforcements, As 4021.24 mm2
Concrete cover, c 50 mm.
Effective depth, d 312 mm.
Lever arm, z = [1-(1.1fyAs / fcubd)]*d 297 mm.
should be less than 0.95d 296.4 mm.
Moment capacity based on concrete, Mu = 0.15fcubd2 2190.24 kN.m
Moment capacity based on steel, Mu = 0.87fyAsz 518 kN.m
Moment capacity of the section, Mu 518 kN.m

Shear Capacity check (3m. Strip):


Links Bar Diameter, Ø 16 mm
Number of legs 2 leg(s)
Material Partial Factor, γm 1.25
Shear stress, v = VU/ bd 0.53 MPa
Allowable Shear stress0.75 sqrt(fcu) = 5.303 MPa
4.75 MPa
Depth Factor, ξS = (500/d)1/4 1.13
Ultimate shear stress, vc = (0.27/γm)(100As/bwd)1/3(fcu)1/3 0.56 MPa
Allowable shear stress, ξS vc 0.63 MPa
Critical Shear Force, Vc 587 kN
DOCUMENT No. (Project/Doc) SHEET No.

EXW-P023-3332-SE-QBJ-CC-00113

SUBJECT
JUNCTION 3A BRIDGE 23/MB/3AA DESIGN CALCULATIONS
SUPERSTRUCTURE

Reference CALCULATIONS OUTPUT