IF-800 Terminal
IF-800 Terminal
Connection to power supply voltage and initial operation may therefore only be carried out by people
trained in electrical engineering.
The electrical installation, in which the device is to be operated, must comply with national standards. To
guarantee trouble-free operation, we recommend carrying out the electrical installation according to the
principles of a TN-S system, which means using separate neutral and grounding conductors.
Secure the power cable with a strain relief.
The device must be equipped with an external separator to ensure that the device can be de-energized.
The device must be equipped with an external fuse protection with a maximum nominal current of 16 A.
3 Function
Access terminals of the series IF-800 are part of an access control system. They are preferably installed
directly next to locking devices. In general, they are connected with an RS485 data cable to a master
terminal, access manager or terminal controller. Terminals of the series IF-800 are designed for controlling
the access of persons, who identify themselves with RFID credentials, as well as for controlling and
monitoring locking devices.
We recommend:
installing a separate, fuse-protected circuit.
keeping a distance of 30 cm between the device and other systems with RFID readers.
keeping a distance of 10cm between connecting cables and power lines.
5 Shielded Cables
To guarantee trouble-free operation, we recommend the use of shielded cables.
Operation, however, is also possible with unshielded cables. Data transfer problems must be examined on a
case-by-case basis. Where necessary, a shielded cable must be used for the corresponding devices.
The I/O controller board must not be installed inside the appliance case due to the
risk of manipulation or tampering.
Install the I/O controller board in a secured area.
Install the power supply line in duplicate (one conductor pair each). The protective
ground conductor should likewise be installed in duplicate and, in doing so, the drain wire can also be
installed.
A shielded cable with a core diameter of at least 0.6 mm² must be used for the connection between the
terminal strip board and the I/O controller board.
For security reasons, the I/O controller board should be mounted in a secured area.
Switch 1 2 3 4
Address 1 OFF OFF OFF OFF (not required if connected to a master terminal)
Address 2 ON OFF OFF OFF
Address 3 OFF ON OFF OFF
Address 4 ON ON OFF OFF
Address 5 OFF OFF ON OFF
Address 6 ON OFF ON OFF
Address 7 OFF ON ON OFF
Address 8 ON ON ON OFF
1 Anti-tamper switch
2 RFID board
3 Design kit
4 Large cutouts for latching the front panel
5 Metal retaining clips for fastening in the front panel
6 7-wire cable from terminal to terminal strip board
7 Protective cover
1 Adjusting screw
2 3-pin DIP switch for setting the LEDs
IF design OFF ON ON
Third-party design OFF OFF OFF
To protect the I/O controller board against manipulation, it should be installed in a secured area.
It can, for example, be installed in a junction box together with the power supply. In such case, the terminal
strip board must be connected directly to the terminal.
A shielded cable should be used for the connection between the terminal strip board and the I/O
controller board.
The cable length may not exceed 100 m.
Adhesive tape for fastening the terminal strip board in the appliance case is included in delivery.
Power Supply
Low-voltage 12 - 24 VAC/DC measured directly at the terminal
Power consumption Max. 4 VA
Protection Via PTC resistor
Interfaces RS485; 9600/ 19200 baud (automatic configuration)
Reader RFID reader, MIFARE or LEGIC (depending on order)
Read range Up to 50 mm
Sensor inputs 4 floating sensors (2 per I/O controller board)
Output relays 2 relays with max. 30 V 2 A (1 per each I/O controller board)
User information Buzzer; Green and red LEDs (white and blue are not visible)
General Data
Anti-tamper switch Activated when front panel (design kit) is removed
Ambient temperature -25º C to +55º C
Humidity Max. 95%, non-condensing
Product safety EN 60950-1
Compatibility (EMC) EN 300330-1/-2 EN 301489-1/-3
Dimensions (H x W x D) 71 x 71 x 27 mm
Weight Approx. 0.35 kg
9 Disposal
Once its service life comes to an end, the device must be disposed of properly as
electronic waste. The owner can dispose of the device himself or return it to the
supplier.