Evaporator Temperature Sensor Diagnose

This document provides instructions for removing, inspecting, and installing an evaporator temperature sensor for an air conditioning unit. It describes removing the air conditioning radiator and evaporator temperature sensor. It specifies how to inspect the sensor by measuring its resistance at different temperatures, with a graph showing how resistance decreases as temperature increases. It advises replacing the sensor if inspection results are not within specified ranges. Finally, it describes reinstalling the sensor and air conditioning unit.

Uploaded by

John Dare
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
2K views

Evaporator Temperature Sensor Diagnose

This document provides instructions for removing, inspecting, and installing an evaporator temperature sensor for an air conditioning unit. It describes removing the air conditioning radiator and evaporator temperature sensor. It specifies how to inspect the sensor by measuring its resistance at different temperatures, with a graph showing how resistance decreases as temperature increases. It advises replacing the sensor if inspection results are not within specified ranges. Finally, it describes reinstalling the sensor and air conditioning unit.

Uploaded by

John Dare
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

AC–234 AIR CONDITIONING – EVAPORATOR TEMPERATURE SENSOR

EVAPORATOR TEMPERATURE
SENSOR
REMOVAL
1. REMOVE AIR CONDITIONING UNIT
(a) Remove the air conditioning radiator (see page AC-
185).
2. REMOVE EVAPORATOR TEMPERATURE SENSOR
(See page AC-193)
INSPECTION
1. INSPECT EVAPORATOR TEMPERATURE SENSOR
Sensor (a) Measure the resistance of the sensor.
Standard resistance
Tester Connection Condition Specified Condition
1-2 -10°C (14°F) 7.30 to 9.10 kΩ

Resistance (kΩ) 1-2 -5°C (23°F) 5.65 to 6.95 kΩ


1-2 0°C (32°F) 4.40 to 5.35 kΩ
10.0
1-2 5°C (41°F) 3.40 to 4.15 kΩ
9.0
8.0 1-2 10°C (50°F) 2.70 to 3.25 kΩ
7.0 1-2 15°C (59°F) 2.14 to 2.58 kΩ
6.0 1-2 20°C (68°F) 1.71 to 2.05 kΩ
5.0 1-2 25°C (77°F) 1.38 to 1.64 kΩ
4.0 1-2 30°C (86°F) 1.11 to 1.32 kΩ
3.0
2.0 Temperature (°C) NOTICE:
1.0 (°F) • Even slightly touching the sensor may
0.0 change the resistance value. Be sure to hold
-10 0 10 20 30
AC 14 32 50 68 86
the connector of the sensor.
E126546E01 • When measuring, the sensor temperature
must be almost the same as the ambient
temperature.
HINT:
As the temperature increases, the resistance
decreases (see the graph).
If the result is not as specified, replace the sensor.
AIR CONDITIONING – EVAPORATOR TEMPERATURE SENSOR AC–235

INSTALLATION
1. INSTALL EVAPORATOR TEMPERATURE SENSOR
(See page AC-193)
2. INSTALL AIR CONDITIONING UNIT
(a) Install the air conditioning unit (see page AC-197).

AC