Diffuse Double Layer

1. The model simulates a diffuse double layer using the Poisson-Nernst-Planck equations to account for mass transfer and charge transfer near an electrode surface. 2. The results show the potential and ion concentration profiles predicted by Gouy-Chapman theory, with anion accumulation and cation depletion near the positively polarized electrode. 3. The surface charge density agrees with the low-potential analytical solution of the Gouy-Chapman-Stern model of the diffuse double layer.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
53 views

Diffuse Double Layer

1. The model simulates a diffuse double layer using the Poisson-Nernst-Planck equations to account for mass transfer and charge transfer near an electrode surface. 2. The results show the potential and ion concentration profiles predicted by Gouy-Chapman theory, with anion accumulation and cation depletion near the positively polarized electrode. 3. The surface charge density agrees with the low-potential analytical solution of the Gouy-Chapman-Stern model of the diffuse double layer.
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

Created in COMSOL Multiphysics 5.

Diffuse Double Layer

This model is licensed under the COMSOL Software License Agreement 5.5.
All trademarks are the property of their respective owners. See www.comsol.com/trademarks.
Introduction
Close to an electrode surface, ions in the electrolyte are attracted and repelled by
unscreened excess charge on the electrode. This region is called the diffuse double layer.
Its size is normally a few nanometers away from the electrode surface. The electrical
interactions here mean that charge separation can occur, and the assumption of local
electroneutrality is not valid. The study of the diffuse double layer is important to
applications that consider very thin layers of electrolyte, such as electrochemical capacitors,
atmospheric corrosion problems, ion-selective field effect transistors (ISFETs), and
nanoelectrochemistry.

This example shows how to define a double layer model by combining the Transport of
Diluted Species and Electrostatics physics to account for mass transfer and charge transfer
respectively. The model contains one charged electrode adjacent to bulk solution.

One of the simplest physical models of the double layer is the Gouy-Chapman-Stern
(GCS) model. In Gouy-Chapman theory (Ref. 1, Ref. 2), the diffuse double layer is
treated as a multiphysics coupling of the Nernst-Planck equations for mass transport of all
of the ions, with the Poisson equation (Gauss’s law) for the charge density and electric
field. The combination of these equations is frequently referred to as the Poisson-Nernst-
Planck (PNP) equations or Nernst-Planck-Poisson (NPP) equations.

Gouy-Chapman theory predicts the spatial extent of the diffuse double layer to be of the
same order as the Debye length for the solution, defined for a monovalent binary
electrolyte with concentration cbulk and solvent relative permittivity r:

RT r  0
xD = ---------------------
- (1)
2
2F c bulk

The Stern modification (Ref. 3) to the Gouy-Chapman theory additionally considers the
electric field inside a plane called the outer Helmholtz plane (OHP). This is the plane of
closest approach to the electrode for dissolved ions in solution, due to the finite size of the
ions and surrounding solvent molecules. In the distance of a fraction of a nanometer
between this plane and the electrode surface, Stern’s theory describes the electrolyte as a
dielectric of constant permittivity. This uncharged region of the double layer is sometimes
called the compact double layer.

When there is a low applied potential (< RT/F ~ 25 mV), the Gouy-Chapman-Stern
theory has an analytical solution. The capacitance is predicted to be the same as for a
parallel plate capacitor whose electrode separation is equal to the sum of the Stern layer
size and the Debye length:

2 | DIFFUSE DOUBLE LAYER


r 0
C dl  ------------------- (2)
xD + xS

Model Definition
The model geometry is in 1D (a single interval between 0 and L) and consists of a single
domain, representing the electrolyte phase from the electrode through the diffuse double
layer, as far as the electroneutral bulk solution. The compact component of the double
layer is handled using a boundary condition set at x = 0.

DOMAIN EQUATIONS
The concentrations, ci (SI unit: mol/m3, i=+,-), of two ions of opposite charge (+1/-1)
are solved for in the electrolyte phase. The fluxes (Ji, SI unit: mol/(m2·s)) of the ions are
described by the Nernst-Planck equation

J i = – D i c i – u m i z i Fc i 

with Di (SI unit: m2/s) being the diffusion coefficient, um,i (SI unit: s·mol/kg) the
mobility, F (SI unit: C/mol) the Faraday constant, and  (SI unit: V) the electric potential
in the electrolyte phase.

We assume no homogeneous reactions of the ions in solution. Then, conservation of mass


requires that, for both species:

  Ji = 0

For the potential, the Poisson equation (Gauss’s law) states

   –   = 

where  is the permittivity (SI unit: F/m) and  the charge density (SI unit: C/m). The
charge density depends on the ion concentrations according to:

 = F  c+ – c- 

BOUNDARY CONDITIONS
We choose the bulk solution as the ground condition for the electrolyte potential:

 = 0

which is set at the outer boundary.

3 | DIFFUSE DOUBLE LAYER


The ion concentrations are set to their bulk values at the outer boundary. Because bulk
solution is electroneutral, the positive and negative ions have equal concentrations here.

From Gauss’s law, the electric field inside the compact double layer is constant because this
layer is uncharged and has a uniform permittivity. Hence, according to the Stern theory
for a compact double layer of a constant thickness, S (SI unit: m), the following Robin-
type boundary condition applies for the electrolyte potential:

 +  S  n    =  M

where  M (SI unit: V) is the applied potential of the electrode, as measured against bulk
solution.

For the case of a nonzero Stern layer thickness, the condition can be reformulated as a
surface charge condition that depends on the potential difference,   (SI unit: V),
between the electrode potential and the electrolyte potential at the outer Helmholtz plane
(x = 0):

 
n   –   = – ---------
S

where

 = M – 

The Surface Charge Density condition in Electrostatics is used to define the above condition.
The problem is solved for a sweep of values of  M from 1 mV to 10 mV.

If the electrode is inert to electrolysis of the ions at the electrolyte-electrode interface, no


flux of the ions into the electrode surface can occur. Hence, No Flux conditions are used
for both ion concentrations at the electrode boundary.

4 | DIFFUSE DOUBLE LAYER


Results and Discussion
Figure 1 shows the potential profile in the electrolyte as a line graph and the potential at
the electrode as a point.

Figure 1: Electrolyte potential profile (blue line) and 10 mV applied electrode potential vs bulk
solution (red dot).

The potential difference between the red dot (electrode surface) and the value of the blue
line at x = 0 represents the potential difference over the compact double layer. The
electrolyte potential falls off exponentially on the Debye length scale (Equation 1), as
predicted by Gouy-Chapman theory.

Figure 2 shows the concentrations of the two ionic species. Because the electrode is
polarized positively against bulk solution, it is positively charged and attracts anions while
repelling cations. The concentration profiles confirm that the anion in the electrolyte is
accumulated at the surface, while the cation is depleted.

5 | DIFFUSE DOUBLE LAYER


Figure 2: Concentration profile for the two ions, showing cation depletion (blue line) and
anion accumulation (green line).

Figure 3 shows the surface charge dependence on the applied potential. This agrees
precisely with the low potential analytical expression (Equation 2) for the smaller
potentials. At 10 mV applied potential, a small deviation is observed as the low potential
approximation becomes less precise.

6 | DIFFUSE DOUBLE LAYER


Figure 3: Surface charge density as a function of applied potential difference between the
electrode and bulk solution, comparing simulation results with analytical theory derived in
the limit of low applied potential.

References
1. L.G. Gouy, Comptes Rendues Hebdomadaires des Séances de l’Académie des Sciences,
vol. 149, pp. 654–657, 1909.

2. D.L. Chapman, Philosophical Magazine, vol. 25, pp. 475–481, 1913.

3. O. Stern, Zeitschrift für Elektrochemie, vol. 30, pp. 508–516, 1924.

4. A.J. Bard and L.R. Faulkner, Electrochemical Methods: Fundamentals and


Applications, 2nd ed., Hoboken, 2001.

Application Library path: Batteries_and_Fuel_Cells_Module/


General_Electrochemistry/diffuse_double_layer

7 | DIFFUSE DOUBLE LAYER


Modeling Instructions
From the File menu, choose New.

NEW
In the New window, click Model Wizard.

MODEL WIZARD
1 In the Model Wizard window, click 1D.
2 In the Select Physics tree, select Chemical Species Transport>Nernst-Planck-
Poisson Equations.
3 Click Add.
4 In the Electric potential text field, type phi.
5 In the Added physics interfaces tree, select Transport of Diluted Species (tds).
6 In the Number of species text field, type 2.
7 In the Concentrations table, enter the following settings:

cA
cX

8 Click Study.
9 In the Select Study tree, select General Studies>Stationary.
10 Click Done.

GLOBAL DEFINITIONS
Start by loading some parameters from a text file.

Parameters 1
1 In the Model Builder window, under Global Definitions click Parameters 1.
2 In the Settings window for Parameters, locate the Parameters section.
3 Click Load from File.
4 Browse to the model’s Application Libraries folder and double-click the file
diffuse_double_layer_parameters.txt.

DEFINITIONS
Proceed by adding some variable expressions from a text file.

8 | DIFFUSE DOUBLE LAYER


Variables 1
1 In the Model Builder window, under Component 1 (comp1) right-click Definitions and
choose Variables.
2 In the Settings window for Variables, locate the Variables section.
3 Click Load from File.
4 Browse to the model’s Application Libraries folder and double-click the file
diffuse_double_layer_variables.txt.

GEOMETRY 1
Build the geometry as a single interval.

Interval 1 (i1)
1 In the Model Builder window, under Component 1 (comp1) right-click Geometry 1 and
choose Interval.
2 In the Settings window for Interval, locate the Interval section.
3 In the table, enter the following settings:

Coordinates (m)
0
L_cell

4 Click Build All Objects.

ELECTROSTATICS (ES)

Charge Conservation 1
Now start setting up the physics, begin with the Electrostatics physics (Poisson’s
equation).

1 In the Model Builder window, under Component 1 (comp1)>Electrostatics (es) click


Charge Conservation 1.
2 In the Settings window for Charge Conservation, locate the Constitutive Relation D-E
section.
3 From the r list, choose User defined. In the associated text field, type eps_H2O.

Surface Charge Density 1


1 In the Physics toolbar, click Boundaries and choose Surface Charge Density.
2 Select Boundary 1 only.

9 | DIFFUSE DOUBLE LAYER


3 In the Settings window for Surface Charge Density, locate the Surface Charge Density
section.
4 In the s text field, type rho_surf.

Ground 1
1 In the Physics toolbar, click Boundaries and choose Ground.
2 Select Boundary 2 only.

TRANSPORT OF DILUTED SPECIES (TDS)


Now set up the model for the transport of the ions.

Transport Properties 1
1 In the Model Builder window, under Component 1 (comp1)>
Transport of Diluted Species (tds) click Transport Properties 1.
2 In the Settings window for Transport Properties, locate the Diffusion section.
3 In the DcA text field, type DA.
4 In the DcX text field, type DX.
5 Locate the Migration in Electric Field section. In the zcA text field, type zA.
6 In the zcX text field, type zX.

Initial Values 1
1 In the Model Builder window, click Initial Values 1.
2 In the Settings window for Initial Values, locate the Initial Values section.
3 In the cA text field, type cA_bulk.
4 In the cX text field, type cX_bulk.

Concentration 1
1 In the Physics toolbar, click Boundaries and choose Concentration.
2 Select Boundary 2 only.
3 In the Settings window for Concentration, locate the Concentration section.
4 Select the Species cA check box.
5 In the c0,cA text field, type cA_bulk.
6 Select the Species cX check box.
7 In the c0,cX text field, type cX_bulk.

10 | DIFFUSE DOUBLE LAYER


GLOBAL DEFINITIONS

Default Model Inputs


Set up the temperature value used in the entire model.

1 In the Model Builder window, under Global Definitions click Default Model Inputs.
2 In the Settings window for Default Model Inputs, locate the Browse Model Inputs section.
3 In the tree, select General>Temperature (K) - minput.T.
4 Find the Expression for remaining selection subsection. In the Temperature text field, type
T0.

MESH 1
Edit the default meshing sequence. The mesh parameters are dependent of the Debye
length to make sure the mesh is always a well resolved.

1 In the Model Builder window, under Component 1 (comp1) click Mesh 1.


2 In the Settings window for Mesh, locate the Mesh Settings section.
3 From the Sequence type list, choose User-controlled mesh.

Size 1
1 In the Model Builder window, right-click Edge 1 and choose Size.
2 In the Settings window for Size, locate the Element Size section.
3 Click the Custom button.
4 Locate the Element Size Parameters section. Select the Maximum element size check box.
5 In the associated text field, type h_max.

Size 2
1 Right-click Edge 1 and choose Size.
2 In the Settings window for Size, locate the Geometric Entity Selection section.
3 From the Geometric entity level list, choose Boundary.
4 Select Boundary 1 only.
5 Locate the Element Size section. Click the Custom button.
6 Locate the Element Size Parameters section. Select the Maximum element size check box.
7 In the associated text field, type h_max_surf.
8 Click Build All.

11 | DIFFUSE DOUBLE LAYER


STUDY 1

Step 1: Stationary
Solve the problem using an Auxiliary sweep for a range of potentials.

1 In the Model Builder window, under Study 1 click Step 1: Stationary.


2 In the Settings window for Stationary, click to expand the Study Extensions section.
3 Select the Auxiliary sweep check box.
4 Click Add.
5 In the table, enter the following settings:

Parameter name Parameter value list Parameter unit


phiM (Voltage of electrode vs range(1,1,10) mV
PZC)

6 In the Home toolbar, click Compute.

RESULTS

Electric Potential (es)


Reproduce the figures from the Results and Discussion section as follows:

1 In the Settings window for 1D Plot Group, locate the Data section.
2 From the Parameter selection (phiM) list, choose Last.
3 Locate the Plot Settings section. Select the y-axis label check box.

Line Graph 1
1 In the Model Builder window, expand the Electric Potential (es) node, then click
Line Graph 1.
2 In the Settings window for Line Graph, locate the x-Axis Data section.
3 From the Parameter list, choose Expression.
4 In the Expression text field, type x/xD.
5 Select the Description check box.
6 In the associated text field, type Length (unit Debye lengths).

Point Graph 1
1 In the Model Builder window, right-click Electric Potential (es) and choose Point Graph.
2 Click the Zoom Extents button in the Graphics toolbar.
3 Select Boundary 1 only.

12 | DIFFUSE DOUBLE LAYER


4 In the Settings window for Point Graph, locate the y-Axis Data section.
5 In the Expression text field, type phiM.
6 Locate the x-Axis Data section. From the Parameter list, choose Expression.
7 In the Expression text field, type x/xD.
8 Select the Description check box.
9 In the associated text field, type Length (unit Debye lengths).
10 Click to expand the Coloring and Style section. Find the Line style subsection. From the
Line list, choose None.
11 From the Color list, choose Red.
12 Find the Line markers subsection. From the Marker list, choose Point.
13 From the Positioning list, choose In data points.
14 In the Electric Potential (es) toolbar, click Plot.

Concentrations, All Species (tds)


1 In the Model Builder window, click Concentrations, All Species (tds).
2 In the Settings window for 1D Plot Group, locate the Data section.
3 From the Parameter selection (phiM) list, choose Last.
4 Click to expand the Title section. From the Title type list, choose None.

Species A
1 In the Model Builder window, expand the Concentrations, All Species (tds) node, then
click Species A.
2 In the Settings window for Line Graph, locate the x-Axis Data section.
3 From the Parameter list, choose Expression.
4 In the Expression text field, type x.
5 From the Unit list, choose nm.
6 Click to expand the Legends section. From the Legends list, choose Manual.
7 In the table, enter the following settings:

Legends
A<sup>+</sup> Concentration

Species X
1 In the Model Builder window, click Species X.
2 In the Settings window for Line Graph, locate the x-Axis Data section.

13 | DIFFUSE DOUBLE LAYER


3 From the Parameter list, choose Expression.
4 In the Expression text field, type x.
5 From the Unit list, choose nm.
6 Locate the Legends section. From the Legends list, choose Manual.
7 In the table, enter the following settings:

Legends
X<sup>-</sup> Concentration

8 In the Concentrations, All Species (tds) toolbar, click Plot.

1D Plot Group 5
1 In the Home toolbar, click Add Plot Group and choose 1D Plot Group.
2 In the Settings window for 1D Plot Group, type Surface Charge Density in the Label
text field.
3 Locate the Title section. From the Title type list, choose None.

Point Graph 1
1 Right-click Surface Charge Density and choose Point Graph.
2 Select Boundary 1 only.
3 In the Settings window for Point Graph, locate the y-Axis Data section.
4 In the Expression text field, type rho_surf.
5 Locate the x-Axis Data section. From the Parameter list, choose Expression.
6 In the Expression text field, type phiM.
7 Locate the Coloring and Style section. Find the Line style subsection. From the Line list,
choose None.
8 Find the Line markers subsection. From the Marker list, choose Circle.
9 From the Positioning list, choose In data points.
10 Click to expand the Legends section. Select the Show legends check box.
11 From the Legends list, choose Manual.
12 In the table, enter the following settings:

Legends
Surface charge density (simulation)

13 In the Surface Charge Density toolbar, click Plot.

14 | DIFFUSE DOUBLE LAYER


Global 1
1 In the Model Builder window, right-click Surface Charge Density and choose Global.
2 In the Settings window for Global, locate the y-Axis Data section.
3 In the table, enter the following settings:

Expression Unit Description


Cd_GCS*phiM C/m^2 Surface charge density (theory)

4 Locate the x-Axis Data section. From the Parameter list, choose Expression.
5 In the Expression text field, type phiM.
6 Click to expand the Coloring and Style section. Click to expand the Legends section.

Surface Charge Density


1 In the Model Builder window, click Surface Charge Density.
2 In the Settings window for 1D Plot Group, locate the Plot Settings section.
3 Select the y-axis label check box.
4 In the associated text field, type Charge density (C/m<sup>2</sup>).
5 Locate the Legend section. From the Position list, choose Upper left.
6 In the Surface Charge Density toolbar, click Plot.

15 | DIFFUSE DOUBLE LAYER