FRLM With Internal Autodrain
FRLM With Internal Autodrain
Features
Modular type for easy and fast maintenance
Suitable for wall mounting
Filter - Bronze filtering element
- Separator and shield for efficient moisture separation
Internal Autodrain - Float type, no electrical connections required.
- Manual drain is also provided / possible.
- Provision for drain tube connection, to take the
condensate away from the unit, to keep the working
area clean.
Regulator - Diaphragm operated, relieving type
- Pressure compensated by balanced poppet
- Flow compensated (with venturi) for faster response.
- Non raising 'Press to lock' adjusting knob for locking
at any set pressure
Lubricator - Fog / Mist type Lubricator
- Fine adjustment of lubrication
- Lubrication proportional to flow
Steel bowl guard, bayonet type on FRLM14, FRLM15 & FRLM17 models
Good flow and regulating characteristics
Technical Specifications
Model FRLM14…A FRLM15…A FRLM17…A FRLM17…A
Installation Any position for Regulator. Vertical for Filter and Lubricator
Materials of construction Aluminium, Bronze, Brass, Steel, Acetal, Polycarbonate, SS, Nitrile
Optional accessories * Pressure gauge
@ Supply pressure 7 bar , Set pressure 6 bar , Pressure drop ∆ p = 1bar ( For standard models )
# For details see " How to order "
4.14.1
AIR PREPARATION UNITS
FRL MODULAR Series FRLM1A
Cat No FRLM1A - 01 - A
Model FRLM14...A, FRLM15...A
E GØ
Model FRLM17...A GØ
E
Model W V A B E F GØ J L T J2 H1 H2
Precautions
1. Note the direction of flow before installation and connect piping accordingly.
2. Flush pipings for dirt, dust, rust and other foreign particles.
3. Install in clean atmosphere.
4. Nipples of taper threads ( R ) to be used with teflon tape. Ensure teflon tape doesnot enter the unit during tightening.
Nipples of straight threads ( G ) to be used with sealing washer.
5. Polycarbonate bowls may get damaged and possibly fail if exposed to synthetic oils, thinner, solvents, trichloroethylene,
kerosene or other aromatic hydrocarbons.
Pressure Setting
Pull the knob and adjust by turning the knob clockwise to increase the pressure. Push the knob back to its locked position.
( Turning the knob counter clockwise will reduce the pressure )
4.14.2
AIR PREPARATION UNITS
FRL MODULAR Series FRLM1A
Cat No FRLM1A - 01 - A
Flow Graphs
3/8" FRLM 1/2" FRLM
6 6
5 5
Secondary Pressure, bar
3 3
2 2
1 1
6 6
Secondary Pressure, bar
5 5
4 4
3 3
2 2
1 1
0 2000 4000 6000 8000 10000 12000 0 2500 5000 7500 10000 12500 15000
How to order
FRLM1 A
Ordering example : Filter Regulator Lubricator Modular - 3/8 ( with G3/8 port size ) with 5µm Filter and pressure range
0.5 - 7 bar with Internal Autodrain: Ordering No: FRLM146213-A
If ordered as 3/8 FRLM with Internal Autodrain, our standard model FRLM146234-A, with 40µm Filter and
pressure range 0.5 - 10 with Internal Autodrain will be supplied.
Subject to change
4.14.3