Compressor Settle-Out Calculation

This document provides specifications for a compressor system including: 1. Dimensions and volumes for the suction vessel, suction line, compressor casing, anti-surge line, discharge line, cooler, and separator tank. 2. It notes that half of the air cooler and compressor casing volumes are attributed to the suction side and half to the discharge side. 3. Settle-out calculations are noted to consider the normal liquid level in the suction drum and dimensions of the air cooler tubes.

Uploaded by

Wicky
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
190 views

Compressor Settle-Out Calculation

This document provides specifications for a compressor system including: 1. Dimensions and volumes for the suction vessel, suction line, compressor casing, anti-surge line, discharge line, cooler, and separator tank. 2. It notes that half of the air cooler and compressor casing volumes are attributed to the suction side and half to the discharge side. 3. Settle-out calculations are noted to consider the normal liquid level in the suction drum and dimensions of the air cooler tubes.

Uploaded by

Wicky
Copyright
© © All Rights Reserved
Available Formats
Download as XLSX, PDF, TXT or read online on Scribd
You are on page 1/ 4

520083-SONATRACH-Compressor S

Inputs
I.D. of Suction Vessel , m 2.895
Length of Suction Vessel (T-T), m 4.267
Volume of Suction Vessel, m3 28.08727848807
Volume occupied by Liquid in suction drum , m3 3.02792315549853
Volume occupied by Gas in suction drum, m3 25.0593553325715
I.D. of Compressor Suction Line, m 0.4064
Length of Compressor Suction Line, m 50

Volume of gas in Compressor Casing, m3 0.25

Compressor Anti-Surge Line Dia., m 0.254


Compressor Suction Line Length downstram of anti-surge valve, m 10
Volume of Gas in Anti-surge Line downstream of Anti-surge valve 0.5067022124
Volume of Suction Line, m3 6.48585573244797
Total Suction Volume (Line+Vessel), Gas Side, m3 32.3019132774195
I.D. of Discharge Line, m 0.254
Length of Discharge Line, m 10
Volume of Discharge Line, m3 0.506707479097498

Volume of Gas in Cooler to be considered on compressor discharge side


5.3840661527379
(Half of total air cooler volume is included on suction side), m3

Total Compressor Discharge Volume, m3 6.1407736318354

Volume of Gas in Cooler to be considered on cooler discharge side, m3 5.3840661527379


I.D. of Cooler discharge line, m 0.254
Length of Cooler Discharge Line, m 10
Volume of Cooler discharge line, m3 0.506707479097498
Compressor Anti-Surge Line Dia., m 0.254
Compressor Suction Line Length downstram of anti-surge valve, m 10
Volume of Gas in Anti-surge Line upstream of Anti-surge valve, m3 0.5067022124
I.D. of Three Phase Separator at discharge of cooler , m 2.135
Length of Three Phase Separator (T-T), m 6.405
Volume of Three Phase Separator, m3 22.9300379851717
Volume occupied by liquid (50 % Volume of Boot+Discharge Piping) 0.14604925
Total Volume of Cooler Discharge, m3 (Gas Side) 29.1814645794071

Total Volume
(Compressor Suction+Compressor
Discharge+Cooler Discharge), m3 65.1640577414226
Compressor Settle-Out Calculation
Remarks

Considering Normal Liquid Level in Suction Drum, m 0.46

Half casing volume to be included on suction side and half


on discharge side (Total casing volume 0.5 m3)

Air Cooler Tube OD, m 0.0254


Thickness of Tube, m 0.001254

Length of Tube, m 19
Total No. of Tubes 1377

Compressor Casing Volume is included


Boot Dia. 610 mm, Boot Length 1000 mm
Neglecting liquid in Boot Liq. Discharge line