0% found this document useful (0 votes)
139 views

TDR20003-TDR2010-TDR2050 - Data Sheet

The document describes advanced dual channel Time Domain Reflectometers (TDRs) for locating faults on metallic cables. The TDR2000/3, TDR2010, and TDR2050 models have features like a color screen, distance-dependent gain, step TDR, 600V input protection, and trace storage and downloading. They are suited for telecom, power, and other cable fault location applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
139 views

TDR20003-TDR2010-TDR2050 - Data Sheet

The document describes advanced dual channel Time Domain Reflectometers (TDRs) for locating faults on metallic cables. The TDR2000/3, TDR2010, and TDR2050 models have features like a color screen, distance-dependent gain, step TDR, 600V input protection, and trace storage and downloading. They are suited for telecom, power, and other cable fault location applications.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

TDR2000/3, TDR2010 and TDR2050

Advanced Dual Channel TDR

„ 600 V CAT IV Input Protection filter built in


„ Step and Pulse TDR selections
„ Distance Dependant Gain
„ Test straight from the box
„ Trace Tagging
„ 2ns pulse width
„ Designed for use on all metallic paired cables

DESCRIPTION 600 V CAT IV input protection


The Megger® TDR2000/3, TDR2010 and TDR2050 are TDR2050 is the first TDR in this class to include a built-
state of the art, dual channel, high resolution, compact in 600 V input protection filter. The ability to connect to
Time Domain Reflectometers with a colour screen for potentially live circuits means a more flexible instrument
locating faults on paired metallic cables. suited for a wider range of applications.
All TDRs in this series have a minimum resolution of 0.1 m / Trace Storage
0.3 ft and a 20 km / 65 kft maximum range depending on 100 internal trace memories provide for the storage and
the velocity factor selected and the cable type. recall of test results. The traces can be recalled to the display
Various output impedances are available (TDR2000/3 and for analysis or compared with an active display to aid in
2010: 25, 50, 75, 100, 125 ohm + AUTO. TDR2050: 25, fault location.
50, 75, 100, 140 ohm + AUTO) and an auto impedance Alternatively the stored results can be downloaded to a
matching feature. The velocity factor can be set between computer, via the USB port, using the TraceXpert software
0.2 and 0.99 to meet any cable test requirements. and USB lead provided.
Step TDR function
FEATURES AND BENEFITS
The Dead Zone effect of a standard pulse TDR can mask
The TDR2000 series have a large, high resolution, colour,
near end faults and make them undetectable. The addition
WVGA display with easy set up features. Directional control
of a step function on the TDR2050 eliminates this problem.
buttons, together with soft keys, provide intuitive and easy
operation for the user. Step TDR technology means that the signal is injected at full
strength and stays there until a disturbance is detected. This
An AUTO selection option ensures that the most effective
makes step TDR technology perfect for detecting near end
parameters are selected depending on the range required,
faults that standard pulse TDRs can miss.
aiding rapid diagnosis of the TDR trace. The ability to
manually override the auto function allows fine tuning to Distance dependant gain
enable identification of hard to determine faults. This feature, built into the TDR2050, eliminates the drop off
of signal attenuation on longer lines by gradually increasing
Dual trace and dual cursor capabilities allow full flexibility,
the gain along the returned signal, enabling a more even
giving the operator full control and instant indication of
representation of the relative attenuation at all points along
distance between two points.
the trace.
A trace comparison feature also allows close examination
between trace conditions. Extra high resolution together
with a white-light backlight, user definable colour schemes
give the graphical display a vibrance, aiding the user in
identifying key events on the trace.
TDR2000/3, TDR2010 and TDR2050
Advanced Dual Channel TDR
Fault identification Models
Megger’s own built-in AutoFind mode allows for speedy The TDR2000 series is available in 4 models.
identification of faults. One press of the AutoFind key TDR2000/3
automatically adjusts the range and gain, and positions A fully featured high resolution TDR with backlit colour
the cursor to the first major event on the cable. Press the display and powered by Li-ion rechargeable battery
AutoFind key again and the cursor will jump to the next batteries. This model comes complete with 2 pairs of mini-
detected disturbance. clip Test Leads.
FindEnd function TDR2000/3P
TDR2050 also incorporates a FindEnd function, which The same as the TDR2000/3 but with Dual fused test leads
allows the user to automatically search the trace to identify replacing the mini-clip leads
the end of the cable under test. This is useful in situations TDR2010
where a fast cable length measurement is required. The same as the TDR2000/3 but with Trace Tagging and
For those who wish to maintain manual control, manual additional Colour Scheme selection.
operation allows full override access to refine the response TDR2050

for easy fault identification. The same as TDR2010 but with the addition of 600 V CAT
Colour schemes IV rating, Step, DDG and FindEnd functions.
The very different light conditions that could be present
when using the TDR2050, combined with the limitations
of eye conditions such as colour blindness, makes the
BENEFITS
addition of set colour schemes in the instrument extremely
■ Backlit graphics colour LCD (800x480)
important.
■ Adjustable display contrast
TDR2010 and TDR2050 have 6 additional set colour ■ Resolution to 0.1 m
schemes on top of the Default and Outdoor schemes ■ AutoFind guide to potential fault location
included on other Megger TDRs. There are also 2 custom ■ 100 trace on board memory
slots where the user can specify their own scheme by ■ USB connection to PC allowing upload and download of traces

setting up to 7 screen elements to their own choice of ■ “TraceXpert” PC software analysis tool

colour. ■ For use on Telecom TNV-3 circuit, or 150 V CAT IV power circuits
(TDR2000/3 and TDR2010 only)
Trace Tagging
■ For use on power circuits to 600 V CAT IV (TDR2050 only)
TDR2010 and TDR2050 also incorporate a Trace Tagging
■ Power blocking filter built-in
feature which allows the user to add a name to saved
■ Environmental protection to IP54
traces. This could be the circuit ID, building name or any ■ Selectable output impedance
other identifying text the user wishes to save with the trace. TDR2000/3 and 2010: 25, 50, 75, 100, 125 ohm + AUTO.
A text string of up to 32 alphanumeric characters can be TDR2050: 25, 50, 75, 100, 140 ohm + AUTO.
■ 2ns pulse for near end fault location
stored against each trace and this can consist of upper case
■ AUTO option selecting gain and pulse for each range
letters including accents.
■ AUTO option matches output impedance to cable
TraceXpert PC software
■ Display distance in metres or feet
The TDR2000/3, TDR2010 and TDR2050 come complete
■ Li-ion rechargeable battery (12 hours typical life)
with the Megger TraceXpert software which gives full
control over downloading, reporting and uploading of
saved trace results. Designed around a database and
programmed for ease of use and simplicity, TraceXpert
offers the ideal application for all your data processing
requirements.
TDR2000/3, TDR2010 and TDR2050
Advanced Dual Channel TDR
SPECIFICATIONS 125 ohm + AUTO.
Except where otherwise stated, this specification applies at an ambient TDR2050: 25, 50, 75, 100, 140 ohm +
temperature of 20°C AUTO.
Power down User programmable auto power off timer
GENERAL 1, 5, 10 mins or never.
Range Battery Li-ion rechargeable battery
Up to 20000 m with a minimum resolution of 0.1 m Battery charge time 6 hours at 0 °C to 40 °C
(Maximum range dependent on cable type)
Battery life 12 hours typical
m ft ns
Safety These instruments comply with
10 30 125 IEC61010-1 for connections to live
25 80 250 systems up to 150 V CAT IV or 300 V CAT
III (TDR2000/3 and 2010 only).
50 160 500
 TDR2050 is rated at 600 V CAT IV.
100 320 100 Fused leads must be used if the voltage
250 800 2500 between terminals exceeds 300 V.
500 1600 5000 Compliant with EN60950-1, EN61010-1,
UN38.3 and EN62133
1000 3200 10000
EMC Complies with Electromagnetic
2500 8000 25000
Compatibility Specifications (Light
5000 16000 50000 industrial) BS EN 61326-1, with a
minimum performance of ‘B’ for all
10000 32500 100000
immunity tests.
20000 65000 200000
Accuracy ±1% of range ±1 pixel at 0.67 VF MECHANICAL
[Note - The measurement accuracy is for IP rating The instrument is designed for use
the indicated cursor position only and is indoors or outdoors and is rated to IP54.
conditional on the velocity factor being
correct. Case ABS
Dimensions 290 mm (11.4 in) x 190 mm (7.5 inches)
x 55 mm (2.2 inches)
Resolution 1% of range
Weight 1.7kg (3.8lbs)
Input protection This instrument complies with IEC61010-
1 to protect the user in the event of Connectors Four 4mm-safety terminals and two
connection to live systems. TDR2050 is F connectors. Other standard push
rated at 600 V CAT IV whilst all other on adapters will fit. F connectors not
models are rated at 150 V CAT IV. available on TDR2050.
TDR2050 is specifically designed to allow Test lead  DR2000/3 and TDR2010 -
T
use on energised systems up to the rated 2 pairs 2 meters long consisting of 2 x
voltage. 4 mm shrouded connector to miniature
All models are designed for use on de- crocodile clips
energised systems and Megger fused
 DR2000/3P and TDR2050 -
T
leads must be used on power cables and
2 pairs 1.5 meters long retractable sheath
fused leads must be used if the potential
leads
voltage between terminals could exceed
300 V or when connected to CATIV Display 800 x 480 pixel colour graphics LCD,
systems. viewable in external environments.
Output pulse Up to 20 volts peak to peak into open Colour Schemes
circuit. Pulse widths determined by range, Selectable
cable and model used. TDR2000/3 x2
Gain Set for each range with user selectable TDR2010, TDR2050 x8
steps (in Manual operating mode). Custom
Velocity factor Variable from 0.2 to 0.99 in steps of TDR2000/3 x1
0.01. TDR2010, TDR2050 x2

TX null Automatic Backlight Permanent backlight with all colour


Trace Tagging - 32 characters chosen schemes (adjustable brightness)
from upper case letters including accents
Colour schemes - Default, Outdoor, ENVIRONMENTAL
Custom Operating temperature
Step TDR - Eliminates the Dead Zone range and humidity -15 °C to +50 °C (5 °F to 122 °F)
effect.
DDG - Available in ranges 1000 m and Storage temperature
above in 0.5 dB steps range and humidity -20 °C to 70 °C (-4 °F to 158 °F)
Cable Impedance
TDR2000/3 and 2010: 25, 50, 75, 100,
TDR2000/3, TDR2010 and TDR2050
Advanced Dual Channel TDR

ORDERING INFORMATION
Description Order Code Description Order Code
TDR2050 UK Power TDR 1005-021 Included accessories
TDR2050 EU Power TDR 1005-022 TDR2000/3P and TDR2050 Lead sets
TDR2050 US Power TDR 1005-023 Retractable sheath fused test lead (2 pairs) 1006-511
TDR2050 INT Power TDR 1005-024 Download kit 1003-353
TDR2010 UK Dual Channel Comms 1007-077 Carry case 1003-217
TDR2010 EU Dual Channel Comms 1007-079 AC-DC charger 1003-352
TDR2010 US Dual Channel Comms 1007-078 User guide CD
TDR2010 INT Dual Channel Comms 1007-080
TDR2000/3 UK Time Domain Reflectometer 1007-061 Optional accessories
TDR2000/3 US Time Domain Reflectometer 1007-062 Miniature clip test lead set (1 pair) 6231-652
TDR2000/3 EU Time Domain Reflectometer 1007-063 Split conductor fused test lead set (1 pair) 1002-015
TDR2000/3 INT Time Domain Reflectometer 1007-064 Replacement battery 1002-552
CLF535G Dual channel US 1007-069 Terminal adaptor kit 1003-218
TDR2000/3P UK Time Domain Reflectometer 1007-065 AC power lead - UK 25970-028
TDR2000/3P US Time Domain Reflectometer 1007-066 AC power lead - EU 6180-334
TDR2000/3P EU Time Domain Reflectometer 1007-067 AC power lead - US 25970-002
TDR2000/3P INT Time Domain Reflectometer 1007-068 Red and black probes and clips - for use with
all Megger TDR Fused Test Leads. 1002-491
Retractable sheath fused test lead (1 pair) 1006-511

SALES OFFICE TDR20003--TDR20003P--TDR2010--TDR2050_DS_en_V11


Megger Limited www.megger.com
Archcliffe Road Dover ISO 9001
CT17 9EN England The word ‘Megger’ is a registered trademark
T +44 (0) 1304 502101