Bit Sub New Report Xo 005........

This is an inspection report for a bit sub. The report details the inspection and condition of the boxes, connections, and body. The inspection found the boxes, connections, and body to be free of defects and acceptable for service.

Uploaded by

Khalil Chabbouh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
36 views

Bit Sub New Report Xo 005........

This is an inspection report for a bit sub. The report details the inspection and condition of the boxes, connections, and body. The inspection found the boxes, connections, and body to be free of defects and acceptable for service.

Uploaded by

Khalil Chabbouh
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as DOC, PDF, TXT or read online on Scribd
You are on page 1/ 1

CUSTOMER: Weatherford INSPECTION REPORT

Work location: Weatherford base 2 SPECIFICATION: DS-1 STANDARD CATEGORY 3-5


Report N°: 0503CH18-658 X Visual Inspection connections
WO N°:- X UV Inspection connections
Page: 1 OF 1 X Visual Inspection body
Date: 28 APRIL 2020 X Mag. Particle Insp body
Next inspection due date: 6 months if not use X dimension connections

DESCRIPTION : BIT SUB Serial Number : XO 005 PN°: 294786

BOX BOX BODY


Conn Condition BB/ CONN Condition Condition
Box OD B.B/API BOX OD BOX ID
F.B dia F.B len Type MPI VISUAL DIM2 API TYPE MPI VISUAL DIM2 MPI VISUAL

4 3/4” API N-A N-A 3 ½ IF OK OK OK 4 3/4” 1½” API OK OK OK OK OK
REG
INSPECTION RESULT
3 ½ IF BOX CONNECTION COND: FREE OF DEFECT ACCEPTED
A R
3 ½ REG BOX CONNECTION COND: FREE OF DEFECT ACCEPTED
Float bore Float bore
Total Length
(m) length Diameter BODY COND : FREE OF DEFECT ACCEPTED

0.79 N-A N-A ACCEPTABLE FOR SERVICE AS AT THE TIME OF INSPECTION

Measuring & Test Equipment SN: Cal. Date Measuring & Test Equipment SN: Cal. Date Magnetic Particle Inspection: CONSOMMABLE
UV Light Meter 1320005430 10 10 2019 Vernier Caliper 6M0030 10 10 2019 Magnetizing Process: Continuous X Residual White contrast paint type : pfinder 280 Batch N°: L1101604

Visible Light Meter 1320005430 10 10 2019 Depth Caliper 0501111030 10 10 2019 Magnetizing Process: DC Coil
X AC Yoke X
Black magnetic ink type : pfinder250 Batch N°: L1101278

Electric Coil 176 10 10 2019 Steel Ruler N-A N-A Dry Wet X Wet fluorescent type : pfinder150 Batch N°: L1101539
MPI Technique: Particle fluorescent 0.4/100ml
AC Yoke 7973 10 10 2019 yoke test weight A 205 10 10 2019 fluorescent X visible X
consontration : black ink  2.4/100ml

Magnetic Field Strength Demagnetization: YES X NO Intensity show before visible Intensity: 1200 LUX
UV Light 180 10 10 2019 MNQ3 10 10 2019 strips
Indicator Field Indicator Type: Ac yoke/ pull 1o lbs: yes inspection Black Intensity: 1000 μ watts/cm2 min

INSPECTOR: KHALIL CHABBOUH CUSTOMER REPRESENTATIVE :