Q SERIES Control Network Modules
Q SERIES Control Network Modules
capabilities are packaged into the network product they have selected.
From top to bottom in the network hierarchy, from open architecture Sensor Sensors,
Valves,
Level
protocols to seamless engineered systems, from sensor to enterprise level, etc.
we offer a host of powerful network solutions for users to choose from. While bus speed is a critical factor in measuring performance,
The one common denominator with all Mitsubishi Electric network products there are several other reasons why Mitsubishi Electric network
is unmatched performance. In relative performance data comparisons, solutions excel over others. Easy connectivity, seamless
all our network solutions meet, exceed or dramatically outperform most integration, synergistic performance characteristics of a
competitive networks available on the global market today. Mitsubishi Electric controlled network and above all else -
maximum levels of uptime without sacrificing performance or
productivity. Whether you have an entire factory floor or just an
individual machine to network, you’ll find Mitsubishi Electric’s
expansive range of network options to be the superior choice.
Enterprise Level
Specifications Ethernet (100base-TX) Ethernet (10base-T) Ethernet (10base-5) Ethernet (10base-2)
Network Level Enterprise Enterprise Enterprise Enterprise
Architecture Star (via hub) Star (via hub) Bus Bus
Communications Media Cat. 5 (UTP/STP) Cat. 5 (UTP/STP) via AUI transceiver Coax
Transmission Speed 100Mbit/s 10Mbit/s 10Mbit/s 10Mbit/s
Two levels of cascade connections Four levels of cascade connections
Number of Stations 100/segment 30/segment
via hubs via hubs
Maximum Distance (m) 100/segment 100/segment 500/segment 185/segment
Remote I/O N/A N/A N/A N/A
Control Level
Specifications CC-Link IE Control CC-Link IE Field MELSECNET/H
Network Level Control Control and Device Control
Architecture Loop Bus/Loop/Star (via hub) Bus/Loop
Communications Media Fiber Cat. 5 Fiber/Coax
10/25Mbit/s (depends on
Transmission Speed 1Gbit/s 1 Gbit/s
module used)
Number of Stations 120 120 64 (fiber)/32 (coax)
Maximum Distance (m) 66,000 12,000 30,000 (fiber)/500 (coax)
Remote I/O No Yes Yes
Note: MELSECNET/H is backwards compatible with MELSECNET/10. CC-Link IE was formerly known as MELSECNET/G.
Device Level
Specifications CC-Link DeviceNet PROFIBUS-DP MODBUS/TCP MODBUS/RTU
Network Level Device Device Device Device Device
Architecture Bus Bus Bus Star (via hub) Bus
Communications Media STP Thick/thin trunkline STP Cat. 5 (UTP/STP) STP
12Mbit/s (depends on
Transmission Speed 10Mbit/s (all devices) 0.5Mbit/s 100Mbit/s 115kbps
devices used)
Number of Stations 64 64 60 64 64
1200/segment (extend up to
Maximum Distance (m) 500 1200 100 1200
13.2km with repeaters)
Remote I/O Yes Yes Yes Yes Yes
Sensor Level
Specifications CC-Link/LT AS-i
Network Level Sensor Sensor
Architecture Bus Star, bus or tree
Communications Media Dedicated mechanically keyed cable
Transmission Speed 2.5Mbit/s 172kbit/s
Number of Stations 64 31
Maximum Distance (m) 700 100
Remote I/O Yes Yes
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Q Series Programmable Logic Controllers 1
n Q SERIES PROGRAMMABLE LOGIC CONTROLLERS
Max. Number of Link Points Per Station [LW+LB+LY<=2000 bytes (cyclic communication)]+[LW+LB+LY<=2000 bytes (low-speed cyclic communication)]
Transient Transmission Capacity Max. 1920 bytes/frame
Transmission Speed 10Mbps/25Mbps (depending on switch setting) (*1) 10Mbps 10Mbps
Optical (AS-1000M-B Optical (AS-1000M-B
Cable Type Optical (GI-50/125) Optical (GI-62.5/125)
(SI, 200/250)) (*2) (SI, 200/250)) (*2)
Max. Number of Networks 239
Max. Number of Groups 32
Number of Stations Connected 64 stations (1: control station, 63: normal station)
Overall Distance 30km (98360.67 ft.)
Transmission Speed
Cable Type
10Mbps 25Mbps
Station to Station Distance SI 500m (3278.69 ft.) 200m (1312.33 ft.) 2km (6557.38 ft.)
H-PCF 1km (3278.69 ft.) 400m (1312.33 ft.)
Broadband H-PCF 1km (3278.69 ft.) 1km (3278.69 ft.)
QSI 1km (3278.69 ft.) 1km (3278.69 ft.)
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Q Series Programmable Logic Controllers 3
n Q SERIES PROGRAMMABLE LOGIC CONTROLLERS
MELSECNET/H Control Level Master/Local Network Modules
Model Number QJ71BR11 QJ71NT11B
Stocked Item S S
Certification UL • cUL • CE
Connection Form Simplex bus type Token bus
MELSECNET/H Mode,
MELSECNET/H Mode MELSECNET/10 Mode
MELSECNET/H Extended Mode (*1)
LX/LY 8192 points (8k bits) 8192 points (8k bits)
Max. Number of Link Points Per Network LX/LY 8192 points
LB 16384 points (16k bits) 8192 points (8k bits)
LB 16384 points
W 16384 points (16k words) 8192 points (8k words)
W 16384 points
[LW+LB+LY<=2000 bytes (cyclic MELSECNET/H mode: {(LY+ LB) /8 + (2 × LW)} ≤ 2000 bytes (*2)
Max. Number of Link Points Per Station communication)]+[LW+LB+LY<=2000 bytes MELSECNET/H Extended mode: {(LY+ LB) /8 + (2 × LW)} ≤ 35840
(low-speed cyclic communication)] bytes (*2)
Transient Transmission Capacity Max. 1920 bytes/frame
156kbps/312kbps/625kbps/1.25Mbps/2.5Mbps/5Mbps/10Mbps
Transmission Speed 10Mbps
(Switched by network parameters)
Cable Type Coaxial 75Ω; RG-59B/U RG-11A/U Twisted pair cable or CC-Link Ver.1.10-compatible cable (*4)
Max. Number of Networks 239
Max. Number of Groups 32
Number of Stations Connected 32 stations (1: control station, 31: normal station)
Overall Distance 500m (1639.34 ft.); RG-11A/U) / 300m; (983.61 ft.) (RG-59B/U)
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Q Series Programmable Logic Controllers 5
n Q SERIES PROGRAMMABLE LOGIC CONTROLLERS
CC-Link Device Level Master/Local Network Module (continued)
Model Number QJ61BT11N
Local Local
Remote I/O Remote I/O station or station or
Master
station or station or Intelligent Intelligent
station
Remote device Remote device device device
station station station station
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Q Series Programmable Logic Controllers 7
n Q SERIES PROGRAMMABLE LOGIC CONTROLLERS
MODBUS/TCP Network Module
The QJ71MT91 module offers a full MODBUS/TCP network communications facility to any Q Series system. Use this module to establish
control of a MODBUS/TCP network of devices from a Q Series based system.
QJ71MT91
Model Number
10BASE-T 100BASE-TX
Stocked Item S
Certification UL • cUL • CE
Data Transmission Rate 10Mbps 100Mbps
Maximum Node-To-Node Distance 200m
Maximum Segment Length Between a Hub and Node 100m (Indicates the number of TCP connections that can be established simultaneously)
Number of Cascade Connection Stages Max. 4 stages Max. 2 stages
Transmission
Max. Number of Connections Between a Hub and Node 64 connections (Indicates the number of TCP connections that can be established simultaneously)
Specifications
Number of Routers That Can Be Set 1 default router + any 8 routers
10BASE-T Standard (unshielded twisted pair 100BASE-TX Standard (shielded twisted pair
Cable (Cable compliant with the IEEE802.3)
cable (UTP cable), Category 3, 4, 5) cable (STP cable), Category 5)
Connector Applicable For External Wiring RJ45
Automatic Number of Slaves 64 slaves (Maximum number of slaves that can be communication targets)
Communication Input Area Size 4k words
Function Output Area Size 4k words
Master
Function Number of Instructions That Can Up to 8 instructions (maximum number of dedicated instructions that can be started simultaneously
Be Executed Concurrently from a sequence program)
Dedicated Instruction
Input Area Size Max. 253 bytes per instruction
Output Area Size Max. 253 bytes per instruction
Coil 64k points
Input 64k points
MODBUS
Device Size Input Register 64k points
Slave Function
Holding Register 64k points
Extended File Register Max. 4086k points
No. of Simultaneously Acceptable Request Messages 64
Number of Simultaneously Connectable MELSOFT PCs Max. 8
I/O Device Points Occupied 32 points
5VDC Internal Current Consumption 0.52A
Weight (kg) 0.11
Base Unit Slots Occupied 1
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Q Series Programmable Logic Controllers 9
n Q SERIES PROGRAMMABLE LOGIC CONTROLLERS
PROFINETTM Real Time Master Module
The PROFINET Real Time (RT) communication master for the the Q Series is suitable for PROFINET IO applications. The ME1PN1FW-Q
includes the Q12DCCPU-V hardware, Compact Flash card and license. GX Configurator PN configuration software needs to be purchased
separately using the part number GX-CONFIG-PN-C1.
Model Number ME1PN1FW-Q
Stocked Item S
Certification UL • cUL • CE
Max. Number of Total Cyclic Output Data 9900 Bytes
Max. Number of Cyclic Input Data 1437 Bytes/Device (= IOCR data length)
Max. Number of Cyclic Output Data 1437 Bytes/Device (= IOCR data length)
Max. Number of Configured Devices 128
Min. Cycle Time 1 ms
Max. Cycle Time 512 ms
RT Communication RT Class 1
Acyclic Communication Read/Write Records (< 5448 Bytes/Request)
Alarm Processing Yes
DCP (Discovery & Configure Protocol) Yes
RPC (Remote Procedure Call) Yes (up to 4 fragments 5448 Bytes)
Baud Rate 100MBits/s (Full-Duplex Mode)
Data Transport Layer ETHERNET II (IEEE 802.3)
LLDP Sender Yes
Selection Guide Edition 19 • Revised April 1, 2019 Mitsubishi Electric Automation | Q Series Programmable Logic Controllers 11
n Q SERIES PROGRAMMABLE LOGIC CONTROLLERS
PC Network Cards
Many of our larger scale controller systems are typically integrated into large-scale plant wide networks that require integration with PC based
systems. Mitsubishi Electric addresses this requirement with a range of PC compatible network cards that allow a PC to be directly connected
to a number of our networks. These boards are typically used as the physical network interface for a PC system written in third party
applications such as Microsoft® Visual Basic ™, Visual C++™, etc.
Q80BD- Q80BD- Q80BD- Q81BD- Q80BD- Q80BD- Q80BD- Q80BD- Q81BD-
Model Number
J71GP21-SX J71GP21S-SX J71LP21-25 J71LP21-25 J71LP21G J71LP21GE J71BR11 J61BT11N J61BT11 (*1)
Stocked Item - - S - - - S S -
Certification UL • cUL • CE CE UL • cUL • CE
Network Type CC-Link IE Control MELSECNET/H CC-Link
Optical Fiber Multi-mode Optical Fiber Optical Fiber
Media Type Optical Fiber (62.5 micron) Coax Twisted Pair
(200 micron) Optical Fiber (50 micron) (62.5 micron)
Configuration Type Dual loop Bus
Station Type Master/local
External Power
No Yes No
Supply
Note 1: Supports PCI Express bus.