Rexroth 2-2V - RGC1
Rexroth 2-2V - RGC1
05 1/8
Electric amplifier
for proportional cartridge
throttle valves
Type VT-VRPA1-527-2X/V0/RTS-2/2V
Unit series 2X
Ordering data
VT V R P A 1 527 2X V0 RTS-2/2V
Preferred types
Front panel
Function
– Three setpoint inputs – Internal ramp time adjustment using potentiometer on the
UEI differential input front panel
(b20 = 0...±10 V z20 = 0 V) Accelerate – Decelerate
– UEII relative to control zero (z10) – External ramp time adjustment using voltage-controlled
}
– UEIII cumulative effect (z12) differential inputs UT
– Selection of internal and external ramp time adjustment Accelerate (b16) – Decelerate (b18)
via control input UText. (z6) – Signal output “ramp completed” on UE = 0
LED display on front panel (z18, open collector output to +UA)
– Ramp rise time can be set to LED display on front panel
∆ T 0.1...3 s or – Adjustment: sensitivity
∆ T 0.3...10 s, using the switch on the front panel Qa – limited in the range 100...50 % Qmax
– Ramp function switched on and off via the “Ramp off”
control input (z14)
LED display on front panel indicates the operating mode
4/8 Bosch Rexroth AG Hydraulics VT-VRPA1-527-2X/V0/RTS-2/2V RE 30053/09.05
Technical data
Characteristic values
P.C.B. format mm (100 x 160 x approx. 35) / (W x L x H) Europe card format with front panel
(7 modular spacings)
Plug connector DIN 41612–F32
Ambient temperature °C 0...+70, storage temperature min. –20, max. +70
Power supply Nominal 24 V DC
UB at z2 – b2 Battery voltage 21 ... 40 V, rectified AC voltage
Ueff = 21...28 V (single-phase, full-wave rectification)
Smoothing capacitor, separately to b4, z4 4700 µF/63 V DC, only required if U B ripple > 10 %
Max. valve solenoid A/VA 2.7/40
Current rating A 1.5
The current rating may rise on min. UB and if cable to control
solenoid is extremely long
Power consumption (typical) W 37
Input signal (setpoint) b20: 0...+10 V Differential
z20: 0 V } amplifier
(Ri = 100 kΩ)
Signal source Potentiometer 10 kΩ
Supply +10 V from z32 (10 mA) or external signal source
Output stage enable At z16, U = 8.5...40 V, Ri = 100 kΩ, LED (green) on front panel lights up
Position transducer Power supply b30: –15 V (25 mA)
z30: +15 V (35 mA)
Feedback signal b26: 0...–10 V, RL > 10 kΩ
Feedback reference b28
Solenoid output Clocked current regulator
b6 – b8 A Imax = 2.7
Length of cables between amplifier Solenoid cable: up to 20 m 1.5 mm2
and valve 20 to 60 m 2.5mm2
Position transducer: 4 x 0.5 mm2 (shielded)
Special features Open-circuit protection for feedback signal cable
Closed-loop position control with PID action
Clocked output stage
Rapid energizing and de-energizing for fast response times
Short-circuit-proof outputs
Adjustment Zero via trimming potentiometer ± 5 %
LED displays Green: Enable
Yellow: Feedback signal open circuit
Red: Under-voltage (UB too low)
Fault signal z22: Open collector output to +UK
– Feedback signal open circuit max. 100 mA, no fault: +UK
– UB too low
– ± 15 V stabilization
Note
Connect power zero b2 and control zero b12, b14 or z28 separately to central ground (neutral point).
RE 30053/09.05 VT-VRPA1-527-2X/V0/RTS-2/2V Hydraulics Bosch Rexroth AG 7/8
Notes
Bosch Rexroth AG © This document, as well as the data, specifications and other information
Hydraulics set forth in it, are the exclusive property of Bosch Rexroth AG. It may not be
Zum Eisengießer 1 reproduced or given to third parties without its consent.
97816 Lohr am Main, Germany The data specified above only serve to describe the product. No state-
Telefon +49 (0) 93 52 / 18-0 ments concerning a certain condition or suitability for a certain application
Telefax +49 (0) 93 52 / 18-23 58 can be derived from our information. The information given does not release
[email protected] the user from the obligation of own judgement and verification. It must be
www.boschrexroth.de remembered that our products are subject to a natural process of wear and
aging.