Combined Footing Design
Combined Footing Design
5' X17")
Long Direction
200 b d
Minimun Steel As min =
fy
= 5.928 in²
b = 12 in
As = 0.002 b h
= 0.384 in²/Ft
Select 20 mm ; Ab= 0.487011 in2
Ab x12
Spacing = = 15.219 in²
As
20mmØ @6"c/c
16mmØ @6"c/c
20mmØ @8"c/c
COMBINED FOOTING DESIGN FOR (9.33' X 7.5' X17")
Footing Length,L = 16 Ft
Footing Width,b = 8.5 Ft
Footing Thickness, h = 14 in
Footing Effictive Thickness, d = 11 in
Concrete crushing strength,f'c = 3000 psi
Steel yield strength,fy = 50000 psi
Column Size = 10 in
Long Direction
200 b d
Minimun Steel As min =
fy
= 4.488 in²
b = 12 in
As = 0.002 b h
= 0.336 in²/Ft
Select 20 mm ; Ab= 0.487011 in2
Ab x12
Spacing = = 17.393 in²
As
20mmØ @6"c/c
16mmØ @6"c/c
20mmØ @8"c/c
COMBINED FOOTING DESIGN FOR (9.33' X 7.5' X17")
Footing Length,L = 17 Ft
Footing Width,b = 12 Ft
Footing Thickness, h = 14 in
Footing Effictive Thickness, d = 11 in
Concrete crushing strength,f'c = 3000 psi
Steel yield strength,fy = 50000 psi
Column Size = 16 in
Long Direction
200 b d
Minimun Steel As min =
fy
= 6.336 in²
b = 12 in
As = 0.002 b h
= 0.336 in²/Ft
Select 20 mm ; Ab= 0.487011 in2
Ab x12
Spacing = = 17.393 in²
As
20mmØ @6"c/c
16mmØ @6"c/c
20mmØ @8"c/c
COMBINED FOOTING DESIGN FOR (9.33' X 7.5' X17")
Footing Length,L = 23 Ft
Footing Width,b = 14 Ft
Footing Thickness, h = 22 in
Footing Effictive Thickness, d = 19 in
Concrete crushing strength,f'c = 3000 psi
Steel yield strength,fy = 50000 psi
Column Size = 16 in
Long Direction
200 b d
Minimun Steel As min =
fy
= 12.768 in²
b = 12 in
As = 0.002 b h
= 0.528 in²/Ft
Select 20 mm ; Ab= 0.487011 in2
Ab x12
Spacing = = 11.068 in²
As
20mmØ @6"c/c
16mmØ @6"c/c
20mmØ @8"c/c