ASCE 7-10 Load Combination: 2.3.2 Ultimate Stress

This document outlines load combinations and equations for ultimate stress and allowable stress design according to ASCE 7-10 and AS1170 standards. For ultimate stress design, it lists 14 load combinations (U100-U305) involving factors for dead, live, wind, and seismic loads. It also provides an equation for combining horizontal and vertical earthquake effects. For allowable stress design, it lists 13 load combinations (A100-A303) involving factors for dead, live, and wind loads. For AS1170, it summarizes 7 load combinations (U100-U301) involving factors for dead, live, wind, and seismic loads.

Uploaded by

gerald romero
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
78 views

ASCE 7-10 Load Combination: 2.3.2 Ultimate Stress

This document outlines load combinations and equations for ultimate stress and allowable stress design according to ASCE 7-10 and AS1170 standards. For ultimate stress design, it lists 14 load combinations (U100-U305) involving factors for dead, live, wind, and seismic loads. It also provides an equation for combining horizontal and vertical earthquake effects. For allowable stress design, it lists 13 load combinations (A100-A303) involving factors for dead, live, and wind loads. For AS1170, it summarizes 7 load combinations (U100-U301) involving factors for dead, live, wind, and seismic loads.

Uploaded by

gerald romero
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 3

ASCE 7-10

LOAD COMBINATION:

2.3.2 Ultimate Stress

U100 1.4D
U101 1.2D + 1.6L + 0.5Lr
U102 1.2D + 1.6Lr + L
U200 1.2D + 1.6Lr ± 0.5WLx
U201 1.2D + 1.6Lr ± 0.5WLy
U202 1.2D ± 1.0WLx + L + 0.5Lr
U203 1.2D ± 1.0WLy + L + 0.5Lr
U204 0.9D ± 1.0WLx
U205 0.9D ± 1.0WLy
U300 (1.2 + 0.2SDs)D ± ρE + L
U301 (0.9 - 0.2SDs)D ± ρE

E shall be:

E = SRSS or 100%Ex ± 30%Ey and 100%Ey ± 30%Ex

Refer to ASCE 7 for notes

2.4.1 Allowable Stress

A100 D
A101 D + L
A102 D + Lr
A103 D + 0.75L + 0.75Lr
A200 D ± 0.6WLx
A201 D ± 0.6WLy
A202 D + 0.75L ± 0.75(06WLx) + 0.75Lr
A203 D + 0.75L ± 0.75(0.6WLy) + 0.75Lr
A300 D ± 0.7Ex
A301 D ± 0.7Ey
A302 0.6D ± 0.7Ex
A303 0.6D ± 0.7Ey
Load Cases
AS1170
G - Dead Load/SDL
LOAD COMBINATION: Q - Live Load
WLx/y - Wind load on walls
4.2.2 Strength Wu/d - Wind lod on roof (Up/Down)
Eq - Seismic
U100 1.35G
U101 1.2G + 1.5Q
U102 1.2G + 1.5 Q
U200 1.2G + WLx + Wu + Q
U201 1.2G + WLy + Wu + Q
U202 0.9G - WLx - Wd
U203 0.9G - WLy - Wd
U300 1.0G + Eqx + Q
U301 1.0G + Eqy + Q

4.3 Serviceability

Combination of actions for the serviceability limit states shall be


appropriate for the serviceability condition being considered.
Appropriate combinations may include one or a number of the following
using the short-term and long-term values given in Table 4.1:

(a) G
(b)
(c)
(d) Ws
(e) Es
(f) Serviceability values of other actions, as appropriate.