Cygnus Instruments

MK5 Ultrasonic Thickness Gauge - Cygnus 4+ General Purpose

The Cygnus 4+ General Purpose MEASUREMENT STABILITY INDICATOR (MSI™)


thickness gauge is a light, tough Exclusive to Cygnus, MSI™ ensures stable and
multi-mode thickness gauge. It features therefore reliable measurements are displayed in
an A-scan display and simple sequential Echo-Echo and Single-Echo modes.
data logging. The gauge also boasts a
large and bright colour LCD display (with BASIC DATA LOGGING
grayscale option for sunlight readability). Ÿ Linear based data logging
Ÿ Eight user-defined comments to attach to any
measurement point
KEY FEATURES Ÿ Add additional radial points to any measurement
Ÿ Uses single and twin crystal probes
point for extra detail
Ÿ Auto-log feature
Ÿ Measures using Multiple-Echo, Single-Echo and
Echo-Echo Ÿ Saves the A-scan display
Ÿ One and two point calibration Ÿ Records stored on SD card
Ÿ Basic data logging Ÿ CygLink used to transfer and manage data.
Ÿ A-scan display CYGLINK SOFTWARE
Ÿ Manual gain mode CygLink is a Windows® based application used to
Ÿ Large front mounted LCD transfer and manage data logger records, A-scans,
Ÿ Explosive atmosphere: Safe operation, tested to MIL B-scans, templates, measurement comments and
STD 810G Method 511.5 Procedure I material velocity tables. The program can generate PDF
reports and export to Excel. It also displays A-scans and
Ÿ Shock and impact to US MIL STD 810G
B-scans, allowing for after-the-event analysis of logged
Ÿ Environmental sealing (water and dust proof) to IP67 measurements.
– US MIL STD 810G.
VARIETY OF PROBES
THREE VERSATILE MEASURING MODES
Cygnus Stainless Steel INOX Probes (Single Crystal)
Multiple-Echo (Single Crystal Probes) uses three Used in Multiple-Echo mode, these probes include
error checked back wall echoes to provide the most replaceable membranes for long life, require no zeroing
reliable and accurate remaining thickness and have a high linear accuracy.
measurements, with no need to remove coating (up to
20 mm thick (0.8 inch)).

Multiple-Echo Diagram
Cygnus Stainless Steel INOX Probes (Twin Crystal)
Used in Echo-Echo and Single-Echo modes, these
probes have improved measurability on extreme back
wall corrosion and pitting.

Echo-Echo (Twin Crystal Probes) measures through


coatings of up to 1 mm (0.04 inch) thick, ideal for
measuring painted metals with back wall corrosion. DURABLE CABLES
Single-Echo (Twin Crystal Probes) ideal for measuring Using standard industry connectors our probe leads
uncoated metals with heavy back-wall corrosion. Also offers superior flexibility and resistance to oils and
effective on a range of cast metals, plastics and ultraviolet light. The cable will not stiffen after exposure to
composites. ultraviolet light.

www.cygnus-instruments.com
Cygnus Instruments Ltd (UK Headquarters) Tel: +44 (0) 1305 265 533 Email: [email protected]
02/19
CB35UK ISS 5 Cygnus Instruments Inc. (USA) Tel: +1 (410) 267 9771 Email: [email protected]
Cygnus Instruments Middle East (UAE) Tel: +971 50 3459305 Email: [email protected]
Cygnus Instruments (S) Pte Ltd (Singapore) Tel: +65 6252 5909 Email: [email protected]
Cygnus Instruments
MK5 Ultrasonic Thickness Gauge - Cygnus 4+ General Purpose

STANDARD KIT CONTENTS


Cygnus 4+ ultrasonic thickness gauge; padded carry case; operating manual; adjustable neck strap and loops; wrist
strap; accessory pouch; spare membranes; surface and membrane couplant; test block; 3 x AA batteries; mini USB -
USB cable and instruction manual; optional Krusell® belt clip and attachments accessory.
SPECIFICATION
Gauge Cygnus 4+ General Purpose
Measuring Modes Multiple-Echo using 3 sound pulses to ignore coatings up to 20 mm (0.8 inch) thick
Echo-Echo using 2 sound pulses to ignore coatings up 1 mm (0.04 inch) thick
Single-Echo using 1 sound pulse
Materials Sound velocities from 1,000 - 9,000 m/s (0.0390 - 0.3543 in/us)
Accuracy ±0.1 mm (±0.004 inch) or 0.1% of thickness measurement, whichever is greatest, when calibrated in accordance with
Cygnus Instruments calibration procedure
Resolution Multiple-Echo mode - 0.1 mm (0.005 inch) or 0.05 mm (0.002 inch)
Single-Echo and Echo-Echo modes - 0.1 mm (0.005 inch) or 0.5 mm (0.002 inch) or 0.01 mm (0.001 inch)
Probe Diameters Single crystal probes: Twin crystal probes:
and Frequencies Ÿ 6 mm (0.25 inch) - 5 MHz (S5A) Ÿ 5 mm (0.2 inch) - 7.5 MHz (T7A)
Ÿ 13 mm (0.5 inch) - 2.25 MHz (S2C (standard)), Ÿ 8 mm (0.32 inch) - 5 MHz (T5B (standard))
3.5 MHz (S3C) or 5 MHz (S5C) Ÿ 12 mm (0.5 inch) - 2 MHz (T2C (for attenuative materials,
Ÿ 19 mm (0.75 inch) - 2.25 MHz (S2D) cast metals, plastics and composites))
Measurement Single crystal probes: Twin crystal probes (Single-Echo): Twin crystal probes (Echo-Echo):
Range in Steel Ÿ 1 - 250 mm (0.040 - 10.00 inch) Ÿ 0.8 - 250 mm (0.031 - 10.00 inch) Ÿ 3 - 50 mm (0.120 - 2.000 inch)
Connector Twin Lemo 00
Power 3 x AA batteries
Battery Life 10 hours minimum
Electronics Dual channel pulser
Display 2.4 inch quarter VGA LCD
Display Info. Thickness value and A-scan
Size 132 x 82 x 34 mm (3.3 x 5.1 x 1.4 inch) (W x H x D)
Weight 300 grams (10.5 oz.) (inc. batteries)
Operating Temp. -10°C to 55°C (14°F to 131°F)
Data Logging 500,000 measurement points, including A-scan (5,000 readings per record, soft limit of 100 records)
Computer Software CygLink allows remote logging and viewing of A-scan graphs
Survey and report generation to PDF file
Graphic analysis of data and statistical calculations
Designed for Windows® 7 and Windows® 8
Environmental IP67
Rating Explosive Atmosphere: Safe operation as defined by Class I, Division 2, Group D, as found in the National Fire Protection Association
Code (NFPA 70), Article 500, and tested using MIL STD 810G Method 511.5, Procedure I
MIL STD 810G Method 501.6 (high temp +55°C (131°F))
MIL STD 810G Method 502.6 (low temp -20°C (-4°F))
MIL STD 810G Method 507.6 (humidity 95%)
MIL STD 810G Method 512.6 (immersion - 1 metre for 30 mins)
Shock and Impact MIL STD 810G Method 514.7 (vibration - 1 hour each axis)
MIL STD 810G Method 516.7 (shock 20g - 11ms half sine shock pulse, 40g 11ms in each axis)
MIL STD 810G Method 516.7 (26 drops - transit drop 1.22m)
Standards Designed for EN 15317
Environmental RoHS, WEEE compliant
CYGNUS GAUGE
Warranty 3 years on gauge and 6 months on probes WARRANTY

www.cygnus-instruments.com
Cygnus Instruments Ltd (UK Headquarters) Tel: +44 (0) 1305 265 533 Email: [email protected]
02/19
CB35UK ISS 5 Cygnus Instruments Inc. (USA) Tel: +1 (410) 267 9771 Email: [email protected]
Cygnus Instruments Middle East (UAE) Tel: +971 50 3459305 Email: [email protected]
Cygnus Instruments (S) Pte Ltd (Singapore) Tel: +65 6252 5909 Email: [email protected]