The document provides information about Danfoss's CO2 product offerings. It discusses CO2 transcritical booster systems that can achieve high efficiency through heat reclaim and are suitable for cold to mild climates. It also discusses CO2 cascade systems that are efficient for hot climates and can use various refrigerants for the high side. The document aims to educate about CO2 systems and refrigerants while promoting Danfoss products for CO2 applications.

Uploaded by

miguel callata
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
59 views16 pages

Catalogo de Controles CO2

The document provides information about Danfoss's CO2 product offerings. It discusses CO2 transcritical booster systems that can achieve high efficiency through heat reclaim and are suitable for cold to mild climates. It also discusses CO2 cascade systems that are efficient for hot climates and can use various refrigerants for the high side. The document aims to educate about CO2 systems and refrigerants while promoting Danfoss products for CO2 applications.

Uploaded by

miguel callata
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 16

CO2 Controls Catalog

A full line of field-tested CO2 controls,


stocked for your convenience

7000+
CO2 systems built
with Danfoss
products

www.danfoss.us/aftermarket
Why choose Danfoss for CO2?
Danfoss has pioneered CO2 technologies for both transcritical and
subcritical systems for more than ten years and has gained valuable
experience from thousands of installations across six continents.
We offer the widest range of field tested CO2 controls available today.

Want to learn more about CO2?


Danfoss offers a series of CO2 modules in our free, online education
platform. The course catalog includes a full range from refrigeration
basics, to component function, to other new refrigerants. For more
information, visit learning.danfoss.com

Curious about the future of refrigerants?


Our refrigerants website offers an abundance of information about
refrigerants, energy efficiency, sustainability, and the future. Visit
refrigerants.danfoss.com.

Danfoss offers a wide range of products for CO2 . Products included


in this catalog are those used in typical installations. If you need a
product not included in this catalog, please contact us to discuss
other options.

For more information on other Danfoss products visit


choose.danfoss.com
CO2 Transcritical CO2 transcritical booster systems enable high is divided in to three pressure sections: the high
Booster System efficiency heat reclaim and are one of the pressure section, the intermediate pressure
best systems for cold to mild climates. Energy section, and the low pressure section. Controls
consumption is about the same or better than for a transcritical system can be divided into four
R-404A systems and the design is relatively groups: gas cooler controls, receiver controls,
simple. A typical CO2 transcritical booster system injection controls and compressor capacity controls.

AKS 11 GD/DGS
AK-PC 781
AKS 2050

AKS 11

Oil
Separator

AKS 21
NRV NRV
CCMT
(ICMTS)
DMT AKS 2050
AKS 2050
GBC CCM GBC

FC 103

AKS 11

AKS 2050

NRV
AK-SM 8XX/
AKVH AK-SM 350/
AK-SM 720/
AKS 2050 AKA 245
NRV
GBC
DCR AK-CC 550A AKS 11

GBC

AK-PC 781 GD/DGS

AKS 11

AKS 2050

FC 103
NRV
AKVH
AKS 11
AKS 32R NRV
AK-CC 550A AKS 2050
GBC AKS 11
R64-2105.11
Danfoss

GBC

HP High Pressure (1740–2030 psi)


HP Receiver Pressure (870–1305 psi)
LP Suction Pressure MT (508–798 psi)
LP Suction Pressure LT (363–435 psi)

CO2 Controls Catalog 3


Food retail cascade CO2 cascade systems are highly efficient in system controls can be divided into five groups:
HC/HFC- CO2 System hot climates, use a relatively small amount of condenser capacity control, compressor capacity
refrigerant, experience a low temperature change control, cascade injection control, MT evaporator
in the heat exchanger, and can use HC, HFC, or CO2 flow control, and LT evaporator injection
ammonia as the high side refrigerant. Cascade control.

R64-2106.11
Danfoss
FC 103
AK-PC 783

AKS 32R

AKS 11

FC 103
DCR
AKS 11 AKS 11

AKS 32R AKS 32R AK-SM 8XX/


ETS EVR
GD/DGS AK-SM 350/
AK-SM 720/
AKA 245
AKS 2050
AKS 11

AK-CC 450

AKS 2050

AKS 11
AKS 11
Pump

EVRH
SGN

FC 103
AKS 32 R AK-CC 550 A
DCR
AKS 11
GD/DGS AKS 32R
AKVH

AKS 11

HP vapour refrigerant
HP Liquid refrigerant
LP vapour refrigerant

4 CO2 Controls Catalog


Table of Contents

High Pressure Ball Valves...................................................................................................................... 6


GBC H Ball Valves.......................................................................................................................................................................................... 6

Filter Driers............................................................................................................................................ 6
DCR Filter Driers............................................................................................................................................................................................ 6
DCR Cores & Gaskets................................................................................................................................................................................... 6

Pressure Switches.................................................................................................................................. 7
Type KP............................................................................................................................................................................................................. 7

Check Valves.......................................................................................................................................... 7
Type NRV......................................................................................................................................................................................................... 7

Solenoid Valves...................................................................................................................................... 8
EVR Valves....................................................................................................................................................................................................... 8
EVRH Valves.................................................................................................................................................................................................... 8

CO2 Leak Detector................................................................................................................................. 9


Type DGS......................................................................................................................................................................................................... 9

Flash Gas Bypass Valve.......................................................................................................................... 9


Type CCM......................................................................................................................................................................................................... 9
CCM Spare Parts and Accessories........................................................................................................................................................... 9

Electronic Expansion Valves............................................................................................................... 10


Type AKVH....................................................................................................................................................................................................10
High MOPD BX/BJ Coils............................................................................................................................................................................10
AKVH Orifices...............................................................................................................................................................................................10

Small Capacity Gas Cooler Expansion Valve...................................................................................... 11


Type CCMT....................................................................................................................................................................................................11
CCMT Spare Parts and Accessories.......................................................................................................................................................11

Large Capacity Gas Cooler Expansion Valve..................................................................................... 12


Type ICMTS...................................................................................................................................................................................................12
ICAD 600TS Actuator.................................................................................................................................................................................12
ICMT Spare Parts and Accessories........................................................................................................................................................12

Electronic Controllers, type AK.......................................................................................................... 13


Type AK-PC....................................................................................................................................................................................................13
Type AK-CC...................................................................................................................................................................................................13
Type AK-SM...................................................................................................................................................................................................13

Electronic Controllers, type EKC......................................................................................................... 13


Type EKC........................................................................................................................................................................................................13

Temperature Transducers................................................................................................................... 14
Type AKS........................................................................................................................................................................................................14
AKS Spare Parts and Accessories..........................................................................................................................................................14

Temperature Sensors, type AKS......................................................................................................... 14


Type AKS........................................................................................................................................................................................................14

CO2 Controls Catalog 5


High Pressure Ball Valves, GBC H ball valves have been designed and tested to meet the high pressure requirements of CO2.
type GBC These manually operated shut-off valves are suitable for bi-directional flow and can be used in
liquid, suction and hot gas lines. Features include: ball status indicator on spindle top, laser welded
construction, burst-proof spindle design, holes for panel mounting, and sealing materials developed
specifically for CO2.

GBC H Ball Valves


Danfoss Danfoss Inlet Size Cv Value MWP
Inlet Type Outlet Type Outlet Size (in).
Type Code No. (in.) (gpm) (psi)

GBC 6s H 009G7415 solder, ODF 1


⁄4 solder, ODF 1
⁄4 1.09 1305

GBC 10s H 009G7416 solder, ODF 3


⁄8 solder, ODF 3
⁄8 3.52 1305

GBC 12s H 009G7417 solder, ODF 1


⁄2 solder, ODF 1
⁄2 8.05 1305

GBC 16s H 009G7418 solder, ODF 5


⁄8 solder, ODF 5
⁄8 11.11 1305

GBC 18s H 009G7419 solder, ODF 3


⁄4 solder, ODF 3
⁄4 17.88 1305

GBC 22s H 009G7420 solder, ODF 7


⁄8 solder, ODF 7
⁄8 24.64 1305

Filter Driers, type DCR, DCR filter driers with replaceable solid cores are used in liquid and/or suction lines in refrigeration and
and Cores, type DM air conditioning systems. The shells featured below have been designed for high pressure refrigerants.
DM cores contain 100% molecular sieve. They provide high moisture adsorption and protect against
system impurities.

DCR Filter Driers


Danfoss Danfoss Connection Connection Type Weight Max. Pressure Temperature Drying Capacity Liquid Capacity
Type Code No. (in.) (psig) Range (°F) (TR) for CO2 (TR) for CO2
20°F 75°F
DCR 0489 023U7453 1 butt weld/solder, ODF 10 lbs, 6 oz. 667 −40° to 160° 165.1 151.9 27.2
DCR 0969 023U7459 1 butt weld/solder, ODF 13 lbs, 12 oz. 667 −40° to 160° 330.3 303.6 31.7
DCR 09617 023U7464 2 ⁄8
1
butt weld/solder, ODF 14 lbs, 9 oz. 667 −40° to 160° 330.3 303.6 57.0

DCR Cores & Gaskets


Danfoss Type Danfoss Code No. Material
48-DM Core DCR 023U1391 100% molecular sieve
48-DM Solid Core I/P=8 023U1392 100% molecular sieve
DCR Gasket for core shell 023U0058 various

6 CO2 Controls Catalog


Pressure Switches, KP pressure switches protect against excessively low suction or excessively high discharge pressure
type KP and are typically used for starting and stopping compressors and condenser fans. Features include: a
single-pole double-throw (SPDT) switch; ultra-short bounce time, which reduces wear to a minimum
and increases reliability; a manual trip function (an electrical contact function that can be tested
without the need for tools); a fail-safe double bellows element that is fully-welded; vibration and shock
resistance; compact design; and high electrical and mechanical reliability.

KP Pressure Switches
Danfoss Danfoss Pressure Weight Reset Regulation Range Range Differential Max. Working
Type Code No. Connection Type (oz.) Function (psig) (°F) (psi) Pressure (psig)
KP 6W 060-519066 Flare – ¼, male 11 Auto 116 – 610 −15° to 150° 58 – 145 675
KP 6B 060-519166 Flare – ¼, male 10 Man. 116 – 610 −15° to 150° 58 675

Check Valves, NRV check valves can be used in liquid, suction, and hot gas lines in refrigeration and air conditioning
type NRV applications. They ensure that refrigerant flows in the correct direction. A built-in damping piston
makes the valve suitable for installation in lines where pulsation can occur, such as in the discharge line
from the compressor. The NRV 10s H is specifically designed with a high maximum working pressure to
permit use in CO2 applications.

NRV Pressure Check Valves


Danfoss Danfoss Inlet Type Inlet Size Outlet Type Outlet Size Cv Value MWP
Type Code No. (in.) (in.) (gpm) (psi)
NRV 10s H 020-4000 solder, ODF 3
⁄8 solder, ODF 3
⁄8 1040 1305

CO2 Controls Catalog 7


Solenoid Valves, type EVR and EVRH solenoid valves are direct or servo operated for liquid, suction and hot gas lines.
EVR/EVRH, and Standard They are available in both normally closed (NC) and normally open (NO) versions and feature
Coils, type BX/BJ interchangeable AC and DC coils. In standard applications standard BX/BJ coils are suitable to apply
to EVR and EVRH valves; however, in applications with significant pressure differentials high MOPD
BX/BJ coils are recommended. These can be found on page 10.

EVR Valves
Danfoss Danfoss Inlet Type Inlet Size Outlet Type Outlet Size Cv Value Weight w/o Coil
Type Code No. (in.) (in.) (gpm) (oz.)
EVR 2 (NC) 032F7100 solder, ODF 1
⁄4 solder, ODF 1
⁄4 0.18 6
EVR 3 (NC) 032F7105 solder, ODF 1
⁄4 solder, ODF 1
⁄4 0.31 6
EVR 3 (NC) 032F1157 solder, ODF 3
⁄8 solder, ODF 3
⁄8 0.31 6
EVR 4 (NC) 032F7110 solder, ODF 3
⁄8 solder, ODF 3
⁄8 0.70 6 1⁄2
EVR 4 (NC) 032F7111 solder, ODF 1
⁄2 solder, ODF 1
⁄2 0.70 6
EVR 6 (NC) 032F7115 solder, ODF 3
⁄8 solder, ODF 3
⁄8 0.92 6 1⁄2
EVR 6 (NC) 032F1162 solder, ODF 1
⁄2 solder, ODF 1
⁄2 0.92 6 1⁄2
EVR 6 (NC) 032F7117 solder, ODF 5
⁄8 solder, ODF 5
⁄8 0.92 7
EVR 8 (NC) 032F7121 solder, ODF 1
⁄2 solder, ODF 1
⁄2 1.30 11 1⁄2
EVR 8 (NC) 032F7122 solder, ODF 5
⁄8 solder, ODF 5
⁄8 1.30 8 1⁄2
EVR 6 (NO) 032F1164 solder, ODF 3
⁄8 solder, ODF 3
⁄8 0.92 8

EVRH Valves
Danfoss Danfoss Inlet Type Inlet Size Outlet Type Outlet Size Cv Value Weight w/o Coil
Type Code No. (in.) (in.) (gpm) (oz.)
EVRH 10 (NC) 032G1077 solder, ODF 1
⁄2 solder, ODF 1
⁄2 2.20 13 1⁄2
EVRH 15 (NC) 032G1078 solder, ODF 5
⁄8 solder, ODF 5
⁄8 3.01 22 1⁄2
EVRH 20 (NC) 032G1079 solder, ODF 7
⁄8 solder, ODF 7
⁄8 5.80 46

Standard BX/BJ Coils


Danfoss Danfoss Voltage Frequency Power Coil Connection Wire Length Weight
Type Code No. (V) (Hz) Consumption (W) (in.) (oz.)
BX024CS 018F4102 24 50/60 14 1
⁄2 in. conduit hub 18 11 1⁄2
BX024CS 018F4103 24 50/60 14 1
⁄2 in. conduit hub 71 11 1⁄2
BX024CS 018F4104 24 50/60 14 1
⁄2 in. conduit hub 98 11 1⁄2
BX120CS 018F4112 110 50/60 16 1
⁄2 in. conduit hub 18 11 1⁄2
BX120CS 018F4113 110 50/60 16 1
⁄2 in. conduit hub 36 11 1⁄2
BX120CS 018F4114 110 50/60 16 1
⁄2 in. conduit hub 71 11 1⁄2
BX120CS 018F4115 110 50/60 16 1
⁄2 in. conduit hub 98 11 1⁄2
BX240CS 018F4122 230 50/60 17 1
⁄2 in. conduit hub 18 11 1⁄2
BX240CS 018F4123 230 50/60 17 1
⁄2 in. conduit hub 98 11 1⁄2
BJ024CS 018F4100 24 50/60 14 junction box 7 13 1⁄2
BJ120CS 018F4110 110 50/60 16 junction box 7 13 1⁄2
BJ240CS 018F4120 230 50/60 17 junction box 7 13 1⁄2

8 CO2 Controls Catalog


CO2 Leak Detector, Utilizing either Semi-Conductor (SC) or Infrared (IR) technologies, DGS leak detectors give a rapid
type DGS response when detecting a wide range of different refrigerants, including CO2. The DGS sensors can
be used in stand-alone or integrated systems where continuous real-time, automatic monitoring is
required. The DGS complies with environmental regulations and Health & Safety requirements on new
or existing systems.

Type DGS
Danfoss Danfoss Refrigerant Temperature Range Supply Voltage Alarm Set Point
Type Code No. (°F) (V) (ppm)
DGS CO2 Low Temp 080Z2996 CO2 (R744) −40° to 120° 12 – 24 5000
DGS CO2 Standard Temp 080Z2995 CO2 (R744) −4° to 120° 12 – 24 5000

Flash Gas Bypass Valve, The CCM is an electrically operated valve designed specifically for operation in CO2 systems and is
type CCM capable of functioning both as an expansion valve and as a gas bypass valve with back-pressure
regulation in subcritical applications. Additional features include: precise positioning for optimal
control of intermediate pressure in transcritical CO2 systems or liquid injection in heat exchangers,
combined stainless steel butt weld and solder connections for installation in copper piped systems
and a standard M12 connector for simple and flexible connection to the motor driver.

CCM Valves
Danfoss Danfoss Connection Solder Weld Cv Value MWP
Type Code No. Standard Connection Size Connection Size (gpm) (psig)
(in.) (in.)
CCM 10 027H7188 EN10220 5
⁄8 1
⁄2 0.81 1305
CCM 20 027H7187 EN10220 7
⁄8 3
⁄4 2.14 1305
CCM 30 027H7186 EN10220 1 ⁄8 1
1 3.22 1305
CCM 40 027H7185 EN10220 1 1 ⁄8 1 5.55 1305

CCM Spare Parts and Accessories


Danfoss Type Danfoss Code No.
Actuator CCM CO2 valve 027H7184
Wire 4 x 0.5 8000 w/M12 female 034G2323
AST-G driver manual box 034G0013

CO2 Controls Catalog 9


Electronic Expansion The AKVH is a pulse modulating electrically operated expansion valve designed for CO2 refrigeration
Valves, type AKVH, and applications. It features a replaceable coil, wide range of coils for both DC and AC, quiet operation,
High MOPD Coils, type energy efficient operation and long valve life, and the ability to operate as both an expansion and
BX/BJ solenoid valve. AKVH valves should be paired with high MOPD BX/BJ coils.

AKVH Valves
Danfoss Danfoss Inlet Type Inlet Size Outlet Type Outlet Size Rated Capacity Orifice Kit MWP
Type Code No. (in.) (in.) (TR) (psi)
AKVH 10-1 068F4079 solder, ODF 3
⁄8 solder, ODF 1
⁄2 0.37 Kit 0 – 3 1305
AKVH 10-2 068F4080 solder, ODF 3
⁄8 solder, ODF 1
⁄2 0.60 Kit 0 – 3 1305
AKVH 10-3 068F4081 solder, ODF 3
⁄8 solder, ODF 1
⁄2 0.97 Kit 0 – 3 1305
AKVH 10-4 068F4082 solder, ODF 3
⁄8 solder, ODF 1
⁄2 1.51 Kit 4 – 6 1305
AKVH 10-5 068F4083 solder, ODF 3
⁄8 solder, ODF 1
⁄2 2.36 Kit 4 – 6 1305
AKVH 10-6 068F4084 solder, ODF 3
⁄8 solder, ODF 1
⁄2 3.75 Kit 4 – 6 1305

High MOPD BX/BJ Coils


Danfoss Danfoss Voltage Frequency Power Consumption Coil Connection Wire Length Weight
Type Code No. (V) (Hz) (W) (in.) (oz.)

BJ120BS 018F4130 120 60 16 junction box 7 11 1⁄2


BJ208BS 018F4132 208 60 16 junction box 7 11 1⁄2
BJ240BS 018F4134 240 60 16 junction box 7 11 1⁄2
BX120BS 018F4131 120 60 16 1
⁄2 in. conduit hub 98 11 1⁄2
BX208BS 018F4133 208 60 16 1
⁄2 in. conduit hub 98 11 1⁄2
BX240BS 018F4135 240 60 16 1
⁄2 in. conduit hub 98 11 1⁄2

AKVH Orifices
Danfoss Type Danfoss Code No.
Orifice Kit #0-#3 068F5283
Orifice Kit #4-#6 068F5284

10 CO2 Controls Catalog


Small Capacity Gas Cooler The CCMT is an electronically operated valve designed specifically for CO2 systems and can function
Expansion Valve, either as an expansion valve, a pressure regulator for the gas cooler, or a gas bypass valve with
type CCMT back-pressure regulation in transcritical applications. Additional features include: compatibility
with PAG, POE and PVE oils; combined butt weld and solder connections; and a light weight and
compact design.

CCMT Valves
Danfoss Danfoss Temperature Range Connection Solder Weld Cv Value Diff. Range
Type Code No. (°F) Standard Connection Size Connection Size (gpm) (psi)
(in.) (in.)
CCMT 2 027H7200 −40° to 40° EN10220 5
⁄8 1
⁄2 0.19 1305
CCMT 4 027H7201 −40° to 40° EN10220 5
⁄8 1
⁄2 0.52 1305
CCMT 8 027H7202 −40° to 40° EN10220 5
⁄8 1
⁄2 0.92 1305
CCMT 16 027H7231 −40° to 40° EN10220 1 1 ⁄8 1 1.85 1305
CCMT 24 027H7232 −40° to 40° EN10220 1 ⁄8 1
1 2.77 1305
CCMT 30 027H7233 −40° to 40° EN10220 1 1 ⁄8 1 3.70 1305
CCMT 42 027H7234 −40° to 40° EN10220 1 ⁄8 1
1 5.32 1305

CCMT Spare Parts and Accessories


Danfoss Type Danfoss Code No.
Cable with M12 connector 034G2323
EKD 316–converter box 084B8040
EKA–164A Display 084B8563
AKA 211–Cable filter 084B2238
AST-G Manual driver box 034G0013

CO2 Controls Catalog 11


Large Capacity Gas Cooler The ICMTS is a direct operated motorized valve designed to regulate the flow of transcritical gas or
Expansion Valve, subcritical liquid from the gas cooler in a transcritical CO2 system. The ICMTS is driven by actuator type
type ICMTS ICAD 600A-TS.

ICMTS Valves
Danfoss Danfoss Connection Inlet Type Inlet Size Outlet Type Outlet Size Cv Value
Type Code No. Standard (in.) (in.) (gpm)

ICMTS 20-A33 027H1084 EN 10220 butt weld 1 butt weld 1 0.23


ICMTS 20-A 027H1085 EN 10220 butt weld 1 butt weld 1 0.69
ICMTS 20-B 027H1086 EN 10220 butt weld 1 butt weld 1 2.78
ICMTS 20-C 027H1087 EN 10220 butt weld 1 butt weld 1 5.32

ICAD 600TS Actuator


Danfoss Danfoss Cable Supply Supply Analog Input Analog Input Analog Output Dig. Output/ext.
Type Code No. Length Voltage DC Voltage Load Voltage Options Current Options Options Supply Voltage DC
(V) (A) (V) DC (mA) (mA) (V)
ICAD 600A-TS 027H9078 4 ft. 11 in. 24 1.2 0 - 10 / 2 - 10 0 - 20 / 4 - 20 0 - 20 / 4 - 20 5 - 24
ICAD 600A-TS 027H9123 — 24 1.2 0 - 10 / 2 - 10 0 - 20 / 4 - 20 0 - 20 / 4 - 20 5 - 24

ICMT Spare Parts and Accessories


Danfoss Type Danfoss Code No.
Multi-function tool 027H0181
ICMT/S 20-A33 top part w/cone & orifice 027H1088
ICMT/S 20-A top part w/cone & orifice 027H1080
ICMT/S 20-B66 top part w/cone & orifice 027H1094
ICMT/S 20-B top part w/cone & orifice 027H1081
ICMT/S 20-C top part w/cone & orifice 027H1082

12 CO2 Controls Catalog


Electronic Controllers, The AK series of controllers are stand-alone refrigeration system controls. The AK-PC 700 series of
type AK controllers offers rack-level control for various designs including standard HFC systems, transcritical
CO2 systems, and cascade designs. The AK-CC 550A is a single evaporator electronic expansion valve
controller. The AK-SM 800 series is Danfoss’ newest system manager and features “case to cloud”
connectivity for enterprise level data sharing.

AK-PC Controllers
Danfoss Danfoss Function Supply Voltage Communication No. of Compressors
Type Code No. (V) Types (max.)
medium-large transcritical
AK-PC 781 080Z0186 24 LON RS485 8
(single suction)
medium-large transcritical
AK-PC 781 A 080Z0191 24 LON RS485 10
(single suction)
AK-PC 783 080Z0196 cascade system (dual suction) 24 LON RS485 4×4
AK-PC 772 080Z0200 small transcritical (dual-suction) 24 LON RS485 3×2

AK-CC Controllers
Danfoss Danfoss Supply Voltage Communication
Type Code No. (V) Types
AK-CC 550A 084B8036 115 LON RS485, Modbus
AK-CC 550A 084B8030 230 LON RS485, Modbus

AK-SM Controllers
Danfoss Danfoss Function Frequency Communication
Type Code No. (HZ) Types
AK-SM 850 080Z4001 refrigeration 50/60 LON RS485, Modbus
AK-SM 880 080Z4008 refrigeration & HVAC 50/60 LON RS485, Modbus
AK-SM 880 080Z4009 refrigeration & HVAC 50/60 LON TP78, Modbus

Electronic Controllers, The EKC 326A controller, when paired with an ICMTS valve, can be used in transcritical and CO2 systems
type EKC to regulate gas cooler (condenser) pressure and ensure that the system achieves optimal efficiency.

EKC Controllers
Danfoss Danfoss Function Supply Voltage Communication No. of Compressors
Type Code No. (V) Types (max.)
EKC 326A 084B7252 gas cooler for CO2 24 EKA 174 8

CO2 Controls Catalog 13


Temperature Transducers, AKS 2050 ratiometric pressure transmitters convert measured pressure to a linear output and are
type AKS designed specifically for CO2 pressure ranges.

AKS Temperature Transducers


Danfoss Danfoss Operating Range Allowable Working Pressure PB Compensated Pressure Connection
Type Code No. (psi) (psi) Temperature Range Type
(°F)
AKS 2050 060G6342 −14.5 to 855 1450 −22° to 104° ¼ – 18 NPT
AKS 2050 060G6344 −14.5 to 2305 3625 32° to 176° ¼ – 18 NPT

AKS Spare Parts and Accessories


Danfoss Type Danfoss Code No.

Mating plug with 15 ft cable 060G1034

Temperature Sensors, AKS PT1000 temperature sensors utilize a platinum element to ensure optimal accuracy.
type AKS

AKS Temperature Sensors


Danfoss Danfoss Purpose Maximum Ambient Measurable Range Cable Cable Type
Type Code No. Temperature (°F) Temperature Range
(°F) (°F)
superheat
AKS 11 084N0029 212° −58° to 212° −40° to 212° PVC
measurement
AKS 21 084N2003 multipurpose 356° −94° to 356° −60° to 392° silicon

14 CO2 Controls Catalog


CO2 Controls Catalog 15
80 years
The industry’s widest
expertise at your
disposal. We’ve been
looking ahead since
1933.

Danfoss can accept no responsibility for possible errors in catalogs, brochures, and other printed material. Danfoss reserves the right to alter its products without notice.
This also applies to products already on order provided that such alterations can be made without subsequent changes being necessary in specifications already agreed.
All trademarks in this material are property of the respective companies. Danfoss and the Danfoss logotype are trademarks of Danfoss A/S. All rights reserved.

USCO.PK.000.A1.02 © Danfoss | DCS | 2016.11

You might also like