Reference Card - Chromeleon 7.2
Reference Card - Chromeleon 7.2
Chromeleon 7
Chromatography Data System
Chromeleon Software Components
Some Thermo Scientific™ Dionex™ Chromeleon™ 7 components are visible applications with which you interact directly. Other
components run in the background as Windows Services and manage tasks such as instrument control and secure data transfer.
LEGEND: Blue background = Basic component Red background = Advanced component
Chromeleon Objects
Folder: A container for objects. Use folders to organize data in a data vault.
Query: A data vault search to find injections that match certain criteria
Sequence: This is the basic unit of data in Chromeleon. It comprises a set of injections that belong together and contains all
the data and meta-data necessary to recreate sample analysis results.
Instrument Method: A set of timed commands for an instrument to be executed during chromatographic analysis
Processing Method: A collection of parameters (including parameters for peak detection and calibration) that are used for
evaluating a chromatogram
Report Template: Spreadsheet file that defines how data that is related to a sequence is printed or exported.
View Settings: These include settings for displaying the chromatogram, calibration curve, and interactive result tables.
Electronic Report: An electronic version of the results of a sequence
UV Spectral Library: A collection of spectra used for peak identification
Generate and Start Sequence using eWorkflows
Starting an Analysis using any Starting an Analysis using an Editing an eWorkflow
eWorkflow eWorkflow for a Specific Instrument
1. In Chromeleon Console, click the 1. In Chromeleon Console, click the 1. In Chromeleon Console, click
eWorkflows category. Instruments category. the eWorkflows category.
2. In the navigation pane, click the 2. In the navigation pane, select your 2. In the navigation pane, click the
eWorkflow of your choice. instrument. eWorkflow of your choice.
3. In the work area, click the instrument of 3. In the toolbar above the ePanel, click Launch 3. In the toolbar above the list of
your choice. eWorkflow. instruments, click Edit.
4. In the toolbar above the list of 4. Select the eWorkflow of your choice. 4. Modify the eWorkflow as
instruments, click Launch. needed.
5. Follow the wizard and provide the necessary input.
6. Review/edit the sequence that the wizard generates.
7. In the sequence toolbar (above the injection list), click Start.
You can now monitor the running sequence from the Instruments category bar.
Control Instruments
1. In Chromeleon Console, click the Instruments category.
2. In the navigation pane, select the instrument of your choice.
Direct Control/Monitoring via Control the Queue Check Instrument Audit Trails
ePanels
3. In the work area, click the relevant 3. In the work area, click the Queue tab to 3. In the work area, click the Audit tab
tab to see the corresponding see the list of sequences currently waiting to see all the commands sent to and
ePanels. for analysis. parameters received from the
4. Use the controls on the ePanels to 4. You can now add/remove/sort sequences instrument via Chromeleon.
monitor and control the instrument. and start/stop the queue. 4. You can group, filter, and search for
commands of interest.
View Data
1. Open the sequence in Chromatography Studio.
2. Click the Data Processing category.
3. Click the Data Processing Home tab in the ribbon at the top of the screen.
5. Select the Component Table Wizard 5. Activate the Add Component option 5. Select a Peak Window in the
in the Component Table group. in the Component Table group. chromatogram and shift it to the
6. Follow the wizard to define the Time 6. Drag a rectangle around the peak to correct location using the left
range and peak Filter. add it to the component table. mouse button.
7. Enter the component names in the 7. Double click the peak window in the Grab one of the delimiters to
table at the Review stage or add peaks chromatogram and enter the extend or narrow the peak
individually. component name. window.
Data Processing – Calibration
1. Open the sequence in Chromatography Studio.
2. Click the Injection List category. 2. Click the Data Processing category.
3. Assign injection type Calibration Standard to all calibration 3. Click the Data Processing Home tab in the ribbon at the top
standards. of the screen.
4. For each calibration standard, click the Level field and: 4. Activate the Processing Method in the Panes group.
● Assign the correct level, or 5. In the Processing Method, select the Component Table
● Click Create new level to create a new calibration level. tab*.
6. In the calibration Level columns, update the concentrations.
* Processing methods can have different layouts, consisting of different tabs and names. Some of the options might therefore be at
different locations than described here.
Reporting
1. Open the sequence in Chromatography Studio.
2. Click Report Designer.
Helpful Keys
F1 Opens context-sensitive Help
F2 Enables edit mode (e.g. for changing text in table cells)
Ctrl + I Chromeleon Console: Opens Instruments category
Ctrl + D Chromeleon Console: Opens Data category
Ctrl + W Chromeleon Console: Opens eWorkflow category
F4 Chromatography Studio: Takes you to the next injection
Shift + F4 Chromatography Studio: Takes you to the previous injection
F9 Fills a column with the content of the current cell down to the last cell of the column or to the last cell in a
selection
F10 Chromatography Studio: Takes you to the next channel
Shift + F10 Chromatography Studio: Takes you to the previous channel
Ctrl + C Copy selection to clipboard
Ctrl + V Paste clipboard content to selected location
ALT + TAB Switches between open items on the taskbar and can be used to conveniently toggle between Chromeleon
Console and Chromatography Studio windows
Rev. 1.8, P/N 7229.0005 © 2009-2018 Thermo Fisher Scientific Inc. All rights reserved.