GE - Record Plus - MCCB - Selective and Current Limiting
GE - Record Plus - MCCB - Selective and Current Limiting
Industrial Solutions
GE imagination at work
GE imagination at work
Record Plus
GE imagination at work Ed. 6
GE imagination at work
Record Plus
Performance figures
Intro
Contents F
A complete line of selective and current limiting breakers
Protection with flexible and interchangeable trip units G
Common accessories - safe and easy to mount
Wide range of electrical and mechanical operators X
Versatile installation options
5
Record Plus
A complete line of
selective and current limiting breakers
FG400 and FG630 FK800, 1250 and 1600
Rated at 400 and 630A, the FG frame size Rated at 800, 1250 and 1600A, the FK frame
includes all of the advanced features of the sizes are designed for use with the FG400
FD and FE frame sizes. and 630 frame sizes. The design uses
Performance figures
The FG connection area features easy-to- electronic trips units available in a number of
access busbar connections. Cable lugs for performance ranges and allowing a wide
use with single or multiple copper or variety of setting options and groundfault
aluminum conductors are optionally protection. If needed thermal-magnetic and
available. The breaker is designed for use magnetic only trip units are also available.
with interchangeable electronic units that The FK connection area features easy-to-
can be easily adapted to multiple levels of access busbar c onnections or cable lugs for
protection. use with single or multiple copper or
aluminum conductors.
Intro
7
Record Plus
Record Plus™ circuit breakers are designed to protect, isolate and switch circuits in low voltage
istribution networks. Circuit protection is provided by a combination of the devices unique current
d
limiting properties and integrated protection devices commonly referred to as trip units.
The trip units are designed to protect circuits and/or the equipment connected to these circuits and
exist as electromechanical or electronic devices. Numerous electromechanical types are available
as thermal magnetic devices with overload and short-circuit protection or magnetic-only types
providing short-circuit protection. Electronic devices offering wide setting ranges and a more
sophisticated level of protection are available in several versions. Each trip unit has a setting area
finished with a sealable transparant trip unit door.
1250A as single, two, three or four pole are available with rigorously designed and
devices. The electromechanical trip units tested electronic trip units in three and four pole
exist as thermal magnetic, magnetic-only versions with a current range of 25 to 1600A.
and generator protection models. The high-
performance thermal magnetic trip units PremEon
exist as selective and non-selective versions Is an interchangeable electronic trip unit
and are equipped with a fault indicator that designed to offer uncompromising reliability
Intro distinguishes between overload and short- in all network environments in a current
circuit events in accordance with HD 384(1). range of 25-630A.
This patented safety feature allows users to
A reduce downtime by resetting the breaker The first of the line, the PremEon S combines
directly after an overload event. sophisticated 32-bit technology with a built-in
temperature sensor and a complete set of
B protection functions.
- An overload protection (LT) with a range of
0.3 to 1 times the chosen trip unit rating.
C - A delayed short circuit protection (ST) with
a wide setting range and I2t band.
- A selective instantaneous device (I) that uses
D waveform recognition to assure selectivity.
- An optional ground fault protection device
(residual principle) that can be used with
E multiple delay and or I2t settings.
8
Record Plus
Performance figures
current devices are available as side or
bottom mounted units with ratings up to
630A and sensitivities of 30mA to 10A.
The devices slide on to the breaker easily
and are fixed by simply tightening the main
electrical connections. Designed to meet the
latest s tandards, they each have a
mechanical and electrical test option and
share a common cut out.
A de-electric disconnect plug unit and setting
SMR2 areas with transparent, tamper-free cover
Designed to provide a flexible solution for all are standard for the whole line. Intro
protection scenarios in a current range of For ratings above 630A, seperate sensors
250-630A. The device provides an extensive and relays are available, or an integrated
set of protection features as: ground fault protection can be used. A
- An overload protection (LT) with a range of
0.4 to 1 times the chosen trip unit rating.
- A delayed short circuit protection (ST) with B
a wide current and time setting range and
optional I2t bands.
- A selective instantaneous device (I) with a C
wide setting range.
SMR1e, 1s and 1g
The FK Frame can be supplied with a fixed
X
electronic trip unit available in three different
versions.
- SMR1e for selective simplicity.
-S MR1s for a broad range of settable devices.
- SMR1g which is basically an S type with an
additional ground fault device.
9
Record Plus
FG Frame
Breaking capacities
Protection
A
250 N, H, L N, H, L
FG400 350 - N, H, L
400 N, H, L N, H, L
400 N, H, L N, H, L
FG630 500 N, H, L N, H, L
630 N, H, L N, H, L
PremEon S
Selective electronic protection.
Intro SMR2 Number of poles /
protected poles (trips)
Modular electronic protection with
enhanced functionality
3 pole 3 trips N, H, L N, H, L
Y
A Non Automatic or switch
4 pole 3 trips
4 pole 4 trips
N,
N,
H,
H,
L
L
N,
N,
H,
H,
L
L
(not mentioned in tables) 4 pole 3.5 trips (N = 50%) N, H, L N, H, L
6
6 6
7
A.24
Record Plus
FG630 - Circuit breaker in components
Breaker frame without Trip Unit
3 pole 4 pole(1)
50kA In (A) Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no. Cat. no. Ref. no.
FGN
400 FGN306F400NF 431488 FGN406F400NF 431554
630 FGN306F630NF 431491 FGN406F630NF 431560
80kA
400 FGH306F400NF 431067 FGH406F400NF 431153
FGH
Breakers in components
630 FGH306F630NF 431073 FGH406F630NF 431156
Type line 0.625 - 1 x In Adjustable Rating Plugs for Trip Units SMR1
In (A) 3 pole 3 trips 4 pole(1) 4 pole 4 trips(1) 4 pole 3.5 trips (N=50%)(1)
400A 250 FGRJ3NL0250 433148 FGRJ43NL0250 433160 FGRJ4NL0250 433184 FGRJ45NL0250 433172
400 FGRJ3NL0400 435182 FGRJ43NL0400 435188 FGRJ4NL0400 435200 FGRJ45NL0400 435194
630A 400 FGRJ3NN0400 433154 FGRJ43NN0400 433166 FGRJ4NN0400 433190 FGRJ45NN0400 433178
630 FGRJ3NN0630 433157 FGRJ43NN0630 433169 FGRJ4NN0630 433193 FGRJ45NN0630 433181 Intro
Type line/Motor
0.4 - 1 x In Switchable Rating Plugs for Trip Units SMR1
In (A) 3 pole 3 trips 4 pole 3 trips(1) 4 pole 4 trips(1) 4 pole 3.5 trips (N=50%)(1)
400A 400 FGRS3NL0400 433235 FGRS43NL0400 433241 FGRS4NL0400 433253 FGRS45NL0400 433247
A
500(3) 500 FGRS3NN0500 434512 FGRS43NN0500 434521 FGRS4NN0500 434542 FGRS45NN0500 434530
F
Extension modules for the SMR2 Electronic trip unit
Plug-in types replacing the filler module (1 pc max.)
Other Modules
SMR2 External communication and contact module (4 contacts, 1A/400V)(4) FAMECM 434013
One code covers: Module and connection hardware
(1) Neutral on the left. If neutral on the right is needed, please contact us.
(2) 630A trip unit limited to 5 LTD band settings(SMR2), a maximum ST setting of 10 x Ir and a maximum instantaneous setting of 11 x Is.
(3) Specifically configured for Motor Protection
(4) Is needed for Modbus communication (1 per breaker).
A.51
Record Plus
Time Current Curves
Breaker FG630 - SMR1 - Ict = 400A Breaker FG630 - SMR1 - Ict = 500A
10000 10000
2 hr. Influence of current limitation
2 hr. Influence of current limitation
on maximum tripping time on maximum tripping time
100 100
10 10
Millisec (mS)
Millisec (mS)
1000 1000
1 1
10 100 10 100
X Sensor Rating (Ict=400A) X Sensor Rating (Ict=500A)
SMR1 - FG frame
Rating plug set at 1 x sensor rating (Ir=400A). Rating plug set at 1 x sensor rating (Ir=500A).
100 Motor protection mode. 100 Motor protection mode.
Im set a 13 x Ir. Im set a 13 x Ir.
Rating plug set at 1 x sensor rating Rating plug set at 1 x sensor rating
(Ir=400A). (Ir=500A).
Line protection mode. Line protection mode.
Im set a 6 x Ir. Im set a 6 x Ir.
10 10
1 1
0,1 0,1
Intro
Rating plug set at 0.4 x sensor rating (Ir=160A). Rating plug set at 0.5 x sensor rating (Ir=250A).
Line protection mode. Line protection mode.
Im set a 2 x Ir. Im set a 2 x Ir.
0,01 0,01
A
Seconds (S)
Seconds (S)
Class 10 Class 10
0,001 0,001
0,1
X sensor rating (Ict=400A)
1,0 7.2 10,0 100,0 0,1
X sensor rating (Ict=500A)
1,0 7.2 10,0 100,0
B
Breaker FG630 - SMR1 - Ict = 630A Breaker FG630 - SMR1 Magnetic Only - Ict=500A
10000
2 hr. Influence of current limitation
10000
Influence of current limitation
C
on maximum tripping time on maximum tripping time
100 100
D
10 10
Millisec (mS)
Millisec (mS)
1000 1000
1 1
10 100 10 100
X Sensor Rating (Ict=630A) X Sensor Rating (Ict=500A)
100 100
E
Rating plug set at 1 x sensor rating
(Ir=630A).
Line protection mode.
Im set a 10 x Ir. Thermal Withstand Line
Allowing up to Class 30 protection
10 10
F
1 1
Setting range 2 -13 x Ict (500A)
G
0,1 0,1
X
Rating plug set at 0.64 x sensor rating (Ir=400A).
Line protection mode.
Im set a 2 x Ir.
0,01 0,01
Seconds (S)
Seconds (S)
0,001 0,001
0,1 1,0 10,0 100,0 1,0 7.2 10,0 100,0
X sensor rating (Ict=630A) X sensor rating (Ict=500A)
B.17