Product Submittal Sheet

Technical Services: 888-437-3244 Sales: 800-543-7140


Engineering Services: 877-832-3206 clarkdietrich.com

Product category: ProSTUD® 30MIL Drywall Stud 09.22.16 (Non-Structural Metal Framing)
Product name: 550PDS125-30 33ksi G40EQ - Punched
5-1/2" ProSTUD 30MIL (30mil)
Coating: G40EQ
Color coding: Pink
Geometric Properties
Web depth 5.500 in Weight 0.879 lb/ft
Flange width 1.250 in Punchout width 1.500 in
Stiffening lip 0.250 in Punchout length 2.500 in
Design thickness 0.0312 in Minimum thickness 0.0296 in
Yield stress, Fy 33 ksi

Gross Section Properties of Full Section, Strong Axis


Cross sectional area (A) 0.258 in2
Moment of inertia (Ix) 1.072 in4
Radius of gyration (Rx) 2.037 in
Gross moment of inertia (Iy) 0.042 in4
Gross radius of gyration (Ry) 0.404 in
* Embossments in web are only placed on sections 2-1/2"
and wider.
Effective Section Properties, Strong Axis
Effective area (Ae) 0.109 in2 ASTM & Code Standards:
Moment of inertia for deflection (Ixe) 1.048 in4 • AISI S100-12 & S220-15
Section modulus (Sxe) 0.307 in3 • Meets or exceeds ASTM C645 & C754
Allowable bending moment (Ma) 5,544 in-lbs • ASTM E119, E72 & E90
Allowable shear force in web (Unpunched) (Vag) 505 lb • Intertek CCRR-0207, LA RR 26019
Allowable shear force in web (Punched) (Vanet) 505 lb • ProSTUD complies with the SFIA Code
Compliance Certification Program
• Multiple UL® Design Listing including: V438,
Torsional Properties V450 & U419
St. Venant torsion constant (J x 1000) 0.0838 in4 • SDS & Product Certification Information
Warping constant (Cw) 0.248 in6 available at www.clarkdietrich.com
Distance from shear center to neutral axis (Xo) -0.680 in • U.S. Patent No. 9,010,070
Radii of gyration (Ro) 2.185 in
Torsional flexural constant (Beta) 0.903

Unbraced Length (Lu) 28.9 in

Notes:
• Calculated properties are based on AISI S100-12, North American Specification for Design of Cold-Formed Steel Structural Members and AISI S220-15, North American
Standard for Cold-Formed Steel Framing - Nonstructural Members.
• Effective properties incorporate the strength increase from the cold work of forming as applicable per AISI A7.2.
• Tabulated gross properties, including torsional properties, are based on full-unreduced cross section of the studs, away from punchouts.
• For deflection calculations, use the effective moment of inertia.
• Allowable moment includes cold work of forming.
• Allowable moment is taken as the lowest value based on local or distortional buckling. Distortional buckling strength is based on a k-phi = 0.

• East Coast Punch Pattern: Center of knockouts are 12" from the leading edge then 48" o.c.
• West Coast Punch Pattern: Center of knockouts are 24" from the leading edge then 24" o.c.

Sustainability Credits:
For more details and LEED letters contact Technical Services at 888-437-3244 or visit www.clarkdietrich.com/LEED
LEED v4 MR Credit -- Building Product Disclosure and Optimization: EPD (1 point) - Sourcing of Raw Materials (1 point) - Material Ingredients (1 point) - Construction and
Demolition Waste Management (up to 2 points) - Innovation Credit (up to 2 points).
LEED 2009 Credit MR 2 & MR 4 -- ClarkDietrich's steel products are 100% recyclable and have a national average recycled content of 34.2% (19.8% post-consumer and
14.4% pre-consumer). If seeking a higher number to meet Credit MR 5, please contact us at ([email protected] / 888-437-3244)

Project Information Contractor Information Architect Information


Name: Name: Name:
Address: Contact: Contact:
Phone: Phone:
Fax: Fax:

CD-PDS © 07/18 ClarkDietrich Building Systems


Product Submittal Sheet
Technical Services: 888-437-3244 Sales: 800-543-7140
Engineering Services: 877-832-3206 clarkdietrich.com

Product category: ProSTUD® 30MIL Drywall Stud


Product name: 550PDS125-30 33ksi G40EQ - Punched
5-1/2" ProSTUD 30MIL (30mil)

5-1/2" ProSTUD 30MIL (30mil) Drywall Stud - COMPOSITE Limiting Heights (AC86-2015)
(1 layer) 5/8" Type X Gypsum Board
Spacing 5 psf 7.5 psf 10 psf
(inches) L/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360
12 34'-9" 27'-7" 24'-1" 30'-5" 24'-1" 21'-1" 27'-7" 21'-11" 19'-2"

16 31'-7" 25'-1" 21'-11" 27'-7" 21'-11" 19'-2" 25'-1" 19'-11" 17'-4"

24 27'-7" 21'-11" 19'-2" 24'-1" 19'-2" 16'-7" 21'-11" 17'-4" -

Composite Table Notes:


• Allowable composite limiting heights were determined in accordance with ICC-ES AC86-2015.
• Additional composite wall testing and analysis requirements of the SFIA Code Compliance Certification Program were observed.
• In accordance with current building codes and AISI design standards, the 1/3 Stress Increase for strength was not used.
• The composite limiting heights provided in the tables are based on a single layer of type X gypsum board from the following manufacturers: American, CertainTeed,
Georgia Pacific, Continental, National, PABCO, and USG.
• The gypsum board must be applied full height in the vertical orientation to each stud flange and installed in accordance with ASTM C754 using minimum No. 6 Type S
Drywall screws spaced as listed below:
• Screws spaced a minimum of 16 in on-center to framing members spaced at 16 in or 12 in on-center.
• Screws spaced a minimum of 12 in on-center to framing members spaced at 24 in on-center.
• No fasteners are required for attaching the stud to the track except as detailed in ASTM C754.
• Stud end bearing must be a minimum of 1 inch.
• f: Adjacent to the height value indicates that flexural stress controls the allowable wall height.
• s: Adjacent to the height value indicates that shear/end reaction controls the allowable wall height.

5-1/2" ProSTUD 30MIL (30mil) Drywall Stud - NON-COMPOSITE Limiting Heights (FULLY BRACED)
Spacing 5 psf 7.5 psf 10 psf
(inches) L/120 L/240 L/360 L/120 L/240 L/360 L/120 L/240 L/360
12 27'-2" 23'-11" 20'-11" 22'-2" 20'-11" 18'-3" 19'-3" 19'-0" 16'-7"

16 23'-7" 21'-9" 19'-0" 19'-3" 19'-0" 16'-7" 16'-8" 16'-8" 15'-1"

24 19'-3" 19'-0" 16'-7" 15'-8" 15'-8" 14'-6" 13'-7" 13'-7" 13'-2"

Non-Composite Table Notes:


• Heights are based on AISI S100-12, North American Specification, and AISI S220-15, North American Standard for Cold-Formed Steel Framing - Nonstructural Members,
using steel properties alone.
• Above listed Non-Composite Limiting Heights are applicable when the unbraced length is less than or equal to Lu.
• Heights are limited by moment, deflection, shear, and web crippling (assuming 1" end reaction bearing).

Project Information Contractor Information Architect Information


Name: Name: Name:
Address: Contact: Contact:
Phone: Phone:
Fax: Fax:

CD-PDS-LH © 07/18 ClarkDietrich Building Systems