Plate Bearing Test
Plate Bearing Test
This paper presents details of a plate bearing test and report from a site visit in Kuching, Malaysia. Technical
details of a plate bearing test will be presented, including standards and procedures concerned. A sample
method statement will also be discussed. Photos and results from a site visit will conclude the paper.
TECHNICAL DETAILS
Introduction
The Plate Bearing Test is done when shallow foundations are to be used, or when temporary work structures
such as piling rigs or cranes would be required on site. This test checks the bearing capacity of the soil near the
surface of the ground. It also checks the possible settlement under a certain load. The standards applicable to
this test are British Standard (BS) 1377 Part 9 and American Society for Testing and Materials (ASTM) D1194.
Frequency
The Plate Bearing Test may be done at one or several spots at a site, at the discretion of the design engineer.
Sometimes, an experienced contractor may propose additional test locations which shall also depend on the
engineer’s approval.
Test Setup
Figure 1 shows how this test is set up. Basically, it contains a plate, loading column, jack, counter weight,
pressure gauge and settlement gauge.
Figure 1: Plate Bearing Test Setup
The test is done either on ground surface or in a shallow pit where the foundation would sit. The width of the pit
is 4 to 5 times the plate diameter. When digging the pit, care should be taken so that the soil is minimally
disturbed. An excavator without teeth is recommended, and the last 0.2m to 0.5m shall be hand-dug. Retaining
structures shall be installed if necessary.
When the desired pit depth is achieved, the pit bottom is levelled as much as possible. Then, 10mm to 15mm of
sand shall be placed at pit bottom to ensure the levelness of the plate as it is seated. Then, the loading column
and jack will be installed above the plate, approaching the counter weight. It should be made sure that no
eccentricity exists in the setup.
Plate diameter for this test varies from 300mm to 1000mm. It is important to note that the “stress influence
zone” is twice the diameter of the plate, as shown in Figure 2.
Figure 2: Relationship between Plate Size and Stress Influence Zone
Therefore, a bigger plate is desirable when available. The bigger the plate, the better it mimics the actual
conditions. The plate thickness is normally 25mm.
Loading Schedule
The load range that needs to be tested has to be determined. Typically, the maximum load to be tested is 2 to
2.5 times the working load, depending on the factor of safety that needs to be achieved. Loading shall be done
in at least 5 more or less equally spaced increments until the maximum load is reached. Each load shall be
maintained until the average settlement rate is less than 0.02mm per 5 minute interval, or until primary
settlement has ceased. This can be judged from a compression vs log time plot. An example is shown in Figure
3.
Table 1 shows a sample loading step where the working load is 200 kN/m 2. The maximum load to be tested is
2.5 times the working load.
Loading (% of working load) 0, 25, 50, 75, 100, 125, 150, 175, 200, 225, 250
In this loading schedule, the load is increased by 25% or 50 kN/m 2 until it reaches the maximum load to be
tested, which is 500 kN/m2. Each load is held at constant pressure for 15 minutes. Then, unloading is done by
reducing the pressure by 50 kN/m 2 every 15 minutes.
Allowable Settlement
The allowable settlement has to be determined by the design engineer. Although the soil’s bearing capacity
might be satisfactory, caution has to be taken that the settlement is within allowable range. If the soil sinks
rapidly, it is deemed to have passed its ultimate bearing capacity.
The ultimate bearing capacity is sometimes considered as the load at which settlement of 25mm occurs. The
allowable bearing capacity, with a factor of safety of 2, would be one half of the ultimate bearing capacity.
ASTM vs BS
The American and British standards for the Plate Bearing Test are similar. However, there are some differences
that will be discussed here. According to ASTM, the width of a test pit being dug has to be at least 4 times of the
plate diameter. However, BS says this width has to be limited between 4 to 5 times the plate diameter.
ASTM also says that the plate diameter or width is between 300mm – 1000mm. BS specifies 300mm – 600mm.
Key Points
Standard used
ASTM Test D1194-72 – Standard Test Method for Bearing Capacity of Soil for Static Load and Spread Footing.
Instruments
Loading Jack: 10 tonnes hydraulic (Enerpac RC106)
Pressure Gauge: 0 – 10,000 psi
Settlement Gauge: 0 – 50mm with 0.01mm least count
Plate: 300mm diameter
Test Criteria
Working Load: 200 kN/m2
Maximum Load on Plate: 400 kN/m2
Preloading bearing pressure before actual testing: 20 kN/m 2
Test Setup
1. The test pit and reaction load which is sufficiently more than the test loads are prepared.
2. The bottom surface of the pit shall be levelled and the plate is placed at the centre over an evenly spread
sand bed of not more than 10mm.
3. Loading column of sufficient length shall be placed at the centre of the plate and the jack shall be set at
the top of the loading column without any eccentricity to the reaction load.
4. Two settlement gauges with magnetic bases are positioned diagonally over the edges of the plate.
These gauges will measure settlement with reference to a datum bar supported away from the load
influence zone.
Loading Schedule
The table below shows a loading schedule where the working load is 200 kN/m 2 and the maximum load is twice
the working load. At maximum load, the pressure is maintained for 3 hours.
Increment Load as Bearing Applied Load for Jack Gauge Minimum Remarks
% of Working Load Pressure 300mm dia. Plate Reading (psi) Holding
(%) (kN/m ) 2
(kN) Time
(Minutes)
0 0 0 0 15
SITE VISIT
Below are a few points I would like to discuss from the site visit. The site was located at 9th mile, Kuching. It was
a commercial shop lot project. The visit was made in the morning of 12 February 2014.
Test Pit
The test pit was dug using an excavator with teeth. After excavating to the approximate depth required, the
operator was asked to lightly compact the soil with the excavator bucket. Then, the excavator was parked above
the pit as the counter weight.
One problem faced here was that the pit depth was not accurate enough. Therefore, the excavator operator had
to re-dig several times, delaying the test. In my opinion, the testing company should have dug the last 0.2m-0.5m
manually using a spade to achieve the desired depth. Alternatively, suitable extensions could have been used to
adjust the height of the loading column set up. Also, by using the bucket with teeth, the soil in the pit would have
loosened. This will affect the settlement readings. Thus, digging the last few hundred millimetres manually is
highly recommended so as to minimise soil disturbance.
Plate Size
A round plate with a diameter of 300mm was used in this test. Therefore, the effective depth tested was up to
600mm beneath the test pit. This seems quite shallow. Therefore, it is important that the test pit is being dug to
the level where the footing might sit. However, when large plates exists, they are always desirable.
Loading Schedule
The loading schedule as in Table 2 was used at this site. The working load was 200 kN/m2, and the maximum
load tested was 400 kN/m2.
Test Results
The test results are tabulated as follows:
The test was stopped at the bearing pressure of 400 kN/m 2 without proceeding with unloading because the
settlement had exceeded the allowable limit of 30mm, which was predetermined by the design engineer. At 350
kN/m2, the settlement was 29.85mm and at 400 kN/m2 the settlement had increased to 35.77mm. We can
therefore deduce that the ultimate bearing capacity is approximately 350 kN/m 2 and the allowable bearing
capacity (with a Factor of Safety of 2) is 175 kN/m2. The loading vs settlement graph is plotted below.
From the graph, it can be seen that between 100 kN/m 2 to 200 kN/m2 and 300 kN/m2 to 400 kN/m2, the
settlement rate was about the same. Between 200 kN/m2 to 300 kN/m2, the settlement rate was slightly higher.
This implies that as soon as construction completes, a higher settlement rate would be experienced if additional
loads are added.
CONCULSION
The Plate Bearing Test is done when shallow foundations are to be used, or when temporary work structures
would be used at a site. It checks the bearing capacity of the soil and possible settlement at a given load.
Caution has to be exercised when following test standards. Factors to be considered by the engineer include
number of tests needed at the site, load range to be tested, size of the plate, and allowable settlement.
In some cases, although not recommended, the design engineer has to modify the standard procedure to suit
local conditions. Nonetheless, sound judgment is needed whenever deviations from the standards are deemed
necessary.
APPENDIX
Pit preparation – laying of sand to ensure levelness at the bottom of the pit for test plate and loading column to
sit on
A tarpaulin is used to cover the apparatus from inclement weather