Lynx L210-F2G-EX: Industrial Ethernet 10-Port Switch
Lynx L210-F2G-EX: Industrial Ethernet 10-Port Switch
com
Lynx
L210-F2G-EX
Industrial Ethernet
10-port Switch
WeOS
2 6643-22601
General information
Legal information
The contents of this document are provided “as is”. Except as required by applicable law,
no warranties of any kind, either express or implied, including, but not limited to, the
implied warranties of merchantability and fitness for a particular purpose, are made in
relation to the accuracy and reliability or contents of this document. Westermo reserves
the right to revise this document or withdraw it at any time without prior notice.
Under no circumstances shall Westermo be responsible for any loss of data or income or
any special, incidental, and consequential or indirect damages howsoever caused.
More information about Westermo can be found at the following Internet address:
www.westermo.com
Software tools
Related software tools are available in the folder software tools under technical support
on the Westermo website.
Upon request, the applicable source code will be provided. A nominal fee may be charged
to cover shipping and media. Please direct any source code request to your normal sales
or support channel.
6643-22601 3
Safety
Before installation:
Read this manual completely and gather all information on the unit. Make sure that
you understand it fully. Check that your application does not exceed the safe operating
specifications for this unit.
This unit should only be installed by qualified personnel.
This unit should be built-in to an apparatus cabinet, or similar, where access is restricted
to service personnel only. Refer to Specific Conditions of Use.
The power supply wiring must be sufficiently fused, and if necessary it must be possible
to disconnect manually from the power supply. Ensure compliance to national installation
regulations.
This unit uses convection cooling. To avoid obstructing the airflow around the unit, follow
the spacing recommendations (see Cooling section).
"Note that this unit can be connected to two different power sources."
Before mounting, using or removing this unit:
Prevent access to hazardous voltage by disconnecting the unit from power supply.
Warning
Do not open connected unit. Hazardous voltage may occur within this unit when
connected to power supply.
Note that this unit can be connected to two different power sources.
When this unit is operated at an ambient temperature above +55°C (+131°F),
the External Surface of Equipment may exceed Touch Temperature Limit according to
EN/IEC/UL 60950-1.
To reduce the risk of fire, use only No. 26 AWG or larger telecommunication
line cord.
For more information see General safety 100-5001.
Care recommendations
Follow the care recommendations below to maintain full operation of unit and to fulfil
the warranty obligations.
This unit must not be operating with removed covers or lids.
Do not attempt to disassemble the unit. There are no user serviceable parts inside.
Do not drop, knock or shake the unit, rough handling above the specification may cause
damage to internal circuit boards.
Do not use harsh chemicals, cleaning solvents or strong detergents to clean the unit.
Do not paint the unit. Paint can clog the unit and prevent proper operation.
Do not expose the unit to any kind of liquids (rain, beverages, etc). The unit is not
waterproof. Keep the unit within the specified humidity levels.
Do not use or store the unit in dusty, dirty areas, connectors as well as other mechanical
part may be damaged.
If the unit is not working properly, contact the place of purchase, nearest Westermo
distributor office or Westermo Tech support.
A readily accessible disconnect device shall be incorporated external to the equipment.
This unit may have hot surfaces when used in high ambient temperature.
4 6643-22601
Maintenance
No maintenance is required, as long as the unit is used as intended within the specified
conditions.
Product disposal
This symbol means that the product shall not be treated
as unsorted municipal waste when disposing of it. It needs
to be handed over to an applicable collection point for
recycling electrical and electronic equipment.
6643-22601 5
ATEX certification
Standards
EN 60079-0, EN 60079-15
Certification code
Ex nA IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
ATEX code
II 3G
6 6643-22601
SFP option approved transceivers
6643-22601 7
ATEX-Zertifizierung
ATEX-Zulassungsnummer
Baseefa12ATEX0119X
Standards
EN 60079-0, EN 60079-15
Zertifizierungscode
Ex nA IIC T3 Gc (–40 °C ≤ Ta ≤ +70 °C)
ATEX-Code
II 3G
Spezifische Einsatzbedingungen
Die Geräte müssen in einem Bereich welcher einem maximalen Verschmutzungsgrad der
Stufe 2 gemäß IEC/EN 60664-1 entspricht und in einem Gehäuse, das einen Schutzgrad
von mindestens IP54 bietet und die relevanten Anforderungen von N 60079-0 und EN
60079-15 erfüllt, installiert werden.
Alle äußeren Anschlüsse des Gerätes und auch die SFP-Module dürfen nur dann
verbunden oder getrennt werden, wenn entweder der Bereich, in dem das Gerät
installiert ist, nachweislich ungefährlich ist, oder die verbundenen Stromkreise
spannungsfrei sind.
Die Netzwerkkabel müssen nach der Installation mithilfe von Kabelbindern oder
ähnlichem Material ordnungsgemäß befestigt werden, um ein versehentliches Abziehen
der Stecker zu verhindern.
8 6643-22601
Für SFP-Option zugelassene Transceiver
6643-22601 9
Certification ATEX
Normes
EN 60079-0, EN 60079-15
Code de certification
Ex nA IIC T3 Gc (–40°C ≤ Ta ≤ +70°C)
Code ATEX
II 3G
10 6643-22601
Transmetteurs optionnels SFP certifiés
6643-22601 11
Agency approvals and standards compliance
FCC Part 15.105 This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
Notice:
reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction
manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the
user will be required to correct the interference at his own expense.
Corrosive This product has been successfully tested in a corrosion test according to IEC 60068-
2-60, method 3. This means that the product meets the requirements to be placed in an
environment environment classified as ISA-S71.04 class G3.
Notice: Note! If the product is placed in a corrosive environment, it is important that all
unused connector sockets are protected with a suitable plug in order to avoid
corrosion attacks on the gold plated pins in connectors.
12 6643-22601
Declaration of Conformity
EU Declaration of Conformity
The manufacturer Westermo Network Technologies AB
SE-635 35 Stora Sundby, Sweden
Herewith declares that the product(s)
Type of product Model 1
Industrial Ethernet Switch Lynx Lx10-F2G-y
is in conformity with the following EU directive(s).
No Short name
2014/30/EU Electromagnetic Compatibility (EMC)
2014/35/EU Low Voltage Directive (LVD)
2014/34/EU Equipment Explosive Atmospheres (ATEX)
2011/65/EU Restriction of the use of certain hazardous substances in electrical and electronic equipment
(RoHS)
References of standards applied for this EU declaration of conformity.
No Title Issue
EN 61000-6-1 Electromagnetic compatibility – Immunity for residential environments 2007
EN 61000-6-2 Electromagnetic compatibility – Immunity for industrial environments 2005 + AC:2005
EN 61000-6-4 Electromagnetic compatibility – Emission for industrial environments 2007 + A1:2011
EN 50121-4 Railway applications - Electromagnetic compatibility Emission and 2016
immunity of the signalling and telecommunications apparatus
EN 60950-1 Information technology equipment - Safety - Part 1: General 2006
requirements + A11: 2009
+ A1: 2010
+ A12: 2011
+ A2: 2013
EN 60079-02 Explosive atmospheres Equipment – General requirements 2018
EN 60079-152 Electrical apparatus for explosive gas atmospheres – Construction, test 2010
and marking of type of protection “n”
EN 50581 Technical documentation for the assessment of electrical and electronic 2012
products w.r.t the restriction of hazardous substances
Pierre Öberg
Technical Manager
25th November 2019
1
x = 1 or 2 and indicates Software Class. y = optional and may indicate customer specific models.
2
Only valid for y = EX model(s). Certificate: Baseefa12ATEX0119X. Issued by: SGS Baseefa Limited, Rockhead Business
Park, Staden Lane, Buxton, Derbyshire, SK17 9RZ, United Kingdom.
Org.nr/
Postadress/Postal address Tel. Telefax Postgiro Bankgiro Corp. identity number Registered office
S-635 35 Stora Sundby 016-428000 016-428001 52 72 79-4 5671-5550 556361-2604 Eskilstuna
Sweden Int+46 16428000 Int+46 16428001
6643-22601 13
Type tests and environmental conditions
Environmental phenomena Basic standard Description Test levels
ESD EN 61000-4-2 Enclosure Contact: ±6 kV
Air: ±8 kV
Fast transients EN 61000-4-4 Power port ±2 kV
Signal ports ±2 kV
Earth port ±1 kV
Surge EN 61000-4-5 Power port L-E: ±1 kV, 12 Ω, 9 μF
L-L: ±1 kV, 2 Ω, 18 μF
L-E: ±2 kV, 42 Ω, 0.5 μF
L-L: ±2 kV, 42 Ω, 0.5 μF
L-E: ±2 kV, 12 Ω, 9 μF
L-L: ±1 kV, 12 Ω, 9 μF
Signal ports L-E: ±1 kV, 2 Ω
L-E: ±2 kV, 42Ω, 0.5 μF
Power frequency magnetic field EN 61000-4-8 Enclosure 300 A/m; 0, 16.7, 50 Hz
Pulsed magnetic field EN 61000-4-9 Enclosure 300 A/m
Radiated RF immunity EN 61000-4-3 Enclosure 20 V/m @ (80 – 2700) MHz
10 V/m @ (2700 – 6000) MHz
1 kHz sine, 80% AM
Conducted RF immunity EN 61000-4-6 Power port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Signal ports 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Earth port 10 V, 80% AM, 1 kHz; (0.15 – 80) MHz
Radiated RF emission CISPR 16-2-3 Enclosure Class A
ANSI C63.4 Class A
(FCC Part 15)
Conducted RF emission CISPR 16-2-1 Power port Class B
ANSI C63.4 Signal ports Class B
(FCC Part 15b)
Dielectric strength EN 60950-1 Power port to all 1.5 kVrms, 50 Hz, 1 min
other ports
Signal ports to all 1.5 kVrms, 50 Hz, 1 min
other ports
Environmental
Temperatures EN 60068-2-1 Operating –40 to +70°C (–40 to +158°F)*
EN 60068-2-2 Storage and transport –50 to +85°C (–58 to +185°F)
Humidity EN 60068-2-30 Operating 5 to 95 % relative humidity
Storage and transport 5 to 95 % relative humidity
Altitude Operating 2 000 m / 70 kPa
Service life Operating 10 year
Reliability prediction (MTBF) MIL-HDBK- 217F Operating 630 000 hours
Vibration IEC 60068-2-6 Operating 3 – 13.2 Hz: 1mm 5.5 – 30 Hz: 1.5 g
(sine) 13.2 – 100 Hz: 0.7 g 30 – 50 Hz: 0.42 mm
50 – 500 Hz: 4.2 g**
Shock IEC 60068-2-27 Operating 30 g, 11 ms
100 g, 6 ms**
Bump IEC 60068-2-27 Operating 10 g, 11 ms
Packaging
Enclosure EN 60950-1 Zinc Fire enclosure
Dimension W x H x D 52.5 x 100 x 101 mm
With connectors 52.5 x 119 x 101 mm
Weight 0.7 kg
Degree of protection EN 60529 Enclosure IP 40
Cooling Convection
** Refer to “Safety” section.
** Might require Ethernet cables to be fastened close to the unit.
14 6643-22601
Description
Lynx is an Industrial switch made for harsh enviroments. The switch can be used in ether
100 Mbit or Gigabit networks due to our multi-rate SFP solution. Lynx can also be used
together with our previous Lynx-series of switches. Our unique FRNT
(Fast Recovery of Network Topology) technology is the fastest protocol on the market
to re-configure a network in the event of any link or hardware failure. That is why Lynx
is used in safety critical applications such as tunnels, traffic signal control and railway
systems.
Installations in harsh environments and places with heavy electrical interference require
the use of a reliable media. Lynx provides a number of solutions using fibre optic
transceivers. Multi- or singlemode transceivers can be used to build point-to-point or
redundant ring networks with ranges up to 120 km between each switch. Our BIDI
transceiver, which transmits and receives data on a single fibre can be used in applications
where the number of fibre cores are limited.
Real-time properties are implemented in the switch in order to achieve determinism
for real time critical applications. Lynx supports QoS (Quality of Service) with four
priority queues and strict priority scheduling as well as HoL (Head of Line Blocking
Prevention). All to assure that the data network is deterministic.
6643-22601 15
Interface specifications
Power
Operating voltage Rated: 24 to 48 VDC
Operating: 19 to 60 VDC
Rated current 240 mA @ 24 VDC
120 mA @ 48 VDC
Rated frequency DC
Inrush current, I2t 22.7·10-3 A2s @ 48 VDC
Startup current* 2 x Rated current
Polarity Reverse polarity protected
Redundant power input Yes
Isolation to All other
Connection Detachable screw terminal
Conductor cross section 0.2 – 2.5 mm2 (AWG 24 – 12)
Stripping length cable 7 mm
Tightening torque, terminal screw 0.5 -0.6 Nm
Tightening torque, screw flange 0.3 Nm
Shielded cable Not required
* External supply current capability for proper start-up
Ethernet TX
Electrical specification IEEE std 802.3. 2005 Edition
Data rate 10 Mbit/s, 100 Mbit/s, manual or auto
Duplex Full or half, manual or auto
Circuit type TNV-1
Transmission range Up to 150 m with CAT5e cable or better*
Isolation to All other
Connection RJ-45, auto MDI/MDI-X
Shielded cable Not required, except when installed in Railway applications as
signalling and telecommunications apparatus and located close
to rails.**
Conductive housing Yes
Number of ports 8
* Refer to Safety section.
** To minimise the risk of interference, a shielded cable is recommended when the cable is located inside 3 m
boundary or the cable is longer than 30 m and inside 10 m boundary to the rails and connected to this port.
16 6643-22601
I/O / Relay output
Maximum voltage/current 60 VDC / 80 mA
Contact resistance Max 30 Ω
Isolation to All other
Connection Detachable screw terminal
Conductor cross section 0.14 – 1.5 mm2 (AWG 28 – 16)
Stripping length cable 7 mm
Tightening torque, terminal screw 0.22 -0.25 Nm
Tightening torque, screw flange 0.3 Nm
Console
Electrical specification TTL-level
Data rate 115.2 kbit/s
Data format 8 data bits, no parity, 1 stop bit, no flow control
Circuit type SELV
Connection 2.5 mm jack, use only Westermo cable 1211-2027
SFP Transceivers
Supported transceivers
Firmware prior to 4.4.0 accepts Westermo branded
transceivers only. From 4.5.0 other transceivers are accepted with a notice and the
unit will no longer be UL approved. Temp.specifications are also depending on the
used transeivers.
Note: To comply with UL60950-1 only UL recognized SFP transceivers should be used.
Deviations
With copper transceiver 1100-0148 the specified operating temperature on Lynx
is 0 to +50ºC (32 to +122°F).
FRNT reconfiguration times can not be guaranteed with copper transceivers.
6643-22601 17
Safety control drawing
Location of interface ports and LED’s
SFP transceivers
(for details see page 4, 9 and 10)
Bottom view
Connection to console port
The console port can be used to connect to the CLI
(Command Line Interface).
The following steps needs to be taken
1. Connect the serial diagnostic cable to the console port
(use only Westermo cable 1211-2027).
2. Connect cable to your computer (USB port, if drivers are needed they can be downloaded
from our Web page).
3. Use a terminal emulator and connect with correct speed and format (115200, 8N1)
to the assigned port.
For more information about the CLI, see the WeOS management guide.
18 6643-22601
Safety control drawing
Power connection
4-position Product Direction Description Input values
marking
1 No. 1 +DC1 Input Supply voltage input DC1
2
3 No. 2 +DC2 Input Supply voltage input DC2 Uin = (19 – 60) VDC
4 Iin = 240 mA @ 24 VDC
No. 3 -COM Input Common PIn = 5.8 W @ 24 VDC
No. 4 -COM Input Common
Lynx supports redundant power connection. The positive inputs are +DC1 and +DC2, the negative input for
both supplies are –COM. Connect the primary voltage (e.g. +24 VDC) to the +DC1 pin and return to one of the
–COM pins on the power input.
I/O connection
Product
4-position Direction Description Input / Output values
marking
1 No. 1 Status + Output Alarm relay (status) contact Uin = 60 VDC max
2
3 No. 2 Status – Output Alarm relay (status) contact Iin = 80 mA max
4
No. 3 Digital in + Input Digital in + Uin = 60 VDC max
The Status output is a potential free, opto-isolated normally closed solid-state relay.
This can be configured to monitor various alarm events within the Lynx unit, see WeOS Management Guide.
An external load in series with an external voltage source is required for proper functionality.
For voltage/current ratings, see Interface Specification section.
Console port
Position Direction* / description Input/output values
No.1 In / out / GND
U = 3.3 VDC max
No. 2 Out / Tx I = 24 mA max
No. 3 In / Rx
* Direction relative to this unit.
2 V Status
3
+
V Digital In
4
–
6643-22601 19
LED indicators
LED Status Description
ON OFF Unit has no power.
GREEN All OK, no alarm condition.
RED Alarm condition, or until unit has started up.
(Alarm conditions are configurable,
see ''WeOS Management Guide'').
BLINK Location indicator ("Here I am!").
Activated when connected to IPConfig Tool,
or upon request from Web or CLI.
DC1 OFF Unit has no power
GREEN Voltage present on DC1*
RED No voltage present on DC1
DC2 OFF Unit has no power
GREEN Voltage present on DC2*
RED No voltage present on DC2.
FRNT OFF FRNT disabled.
GREEN FRNT OK.
RED FRNT Error.
BLINK Unit configured as FRNT Focal Point.
RSTP OFF RSTP disabled.
GREEN RSTP enabled.
BLINK Unit elected as RSTP/STP root switch.
USR1 OFF
GREEN Configurable, see WeOS Management Guide.
RED
1 to 10 OFF No Link.
GREEN Link established.
GREEN Data traffic indication.
FLASH
YELLOW Port alarm and no link. Or if FRNT or RSTP
mode, port is blocked.
*Note: Supply voltage levels must be ensured externally. A green LED
may not guarantee a valid operating voltage level.
20 6643-22601
Mounting
This unit should be mounted on 35 mm DIN-rail, which is horizontally mounted inside an
apparatus cabinet or similar. It is recommended that the DIN-rail is connected to ground.
Snap on mounting, see figure.
Removal
Removing Lynx with integrated DIN-clip:
Press down the support at the back of the unit using a screwdriver. See figure.
Configuration
Configure the unit via Web browser
The unit can easily be configured via a Web browser.
Open the link http://192.168.2.200 in your web browser, and you will be prompted with
a Login screen, where the default settings for Username and Password are:
Username: admin
Password: westermo
Once you have logged in, you can use the extensive integrated help function describing
all configuration options. Two common task when configuring a new switch is to assign
appropriate IP settings, and to change the password of the admin account.
The password can be up to 64 characters long, and should consist of printable ASCII
characters (ASCII 33-126); 'Space' is not a valid password character.
Note! Version of IP Config tool must be 10.3.0 or higher.
22 6643-22601
Referring documents
Type Description Document number
Management Guide Westermo OS management guide 6101-3201
6643-22601 23
Dimensions
Measurements are stated in millimeters.
96 ±1
52 ±1 92 ±1
34 ±1
100 ±1
Max 7,5mm
Min 4mm
24 6643-22601
Westermo • SE-635 35 Stora Sundby, Sweden
Tel +46 16 42 80 00 Fax +46 16 42 80 01
E-mail: [email protected]
www.westermo.com