Released

NEW FEATURES – Release 3.6


∙ VDE-AR-N 4110
∙ G99 Issue 1 Amendment 3

HighPROTEC Protection technology


made simple
∙ Wattmetric Ground Fault Protection
∙ IEC 60870-5-104
∙ SCADApter for Retrofit
MRU4 Voltage and
Frequency RelaY
∙ Usability improvements
∙ IT Security
∙ Improved Frequency and ROCOF precision*

Applic ation

The MRU4 is a protection relay which uses the latest Dual-Core-Processor Technology
to provide precise and reliable protective functions and is very easy to operate.
It is designed to protect electrical equipment from dangerous voltage fluctuations.
For example protection against under voltages caused by mains shortcircuits, or
overvoltages due to load shedding or failure of a generator voltage controller.
Its compact design makes the MRU4 ideal for installation within the LV terminal
compartments of compact SF6-insulated MV systems.
The protection functions of the MRU4 have been adapted to comply with the require-
ments of the VDE‑AR‑N‑4110:2018.

All i n clus i v e: s y n ch ch eck Co m m iss i o n i n g su pp o r t


All protection features inclusive Generator-to-System, System-to-System USB connection
Parameter setting software Options to switch onto dead bus bars Customizable Display (Single-Line, ...)
Disturbance analysis software Customizable Inserts
T wo E le m e n t s r e s i d ual Copy and compare parameter sets
Co m pr e h e n s i v e fr eq u e n c y vo ltag e pr ot ec t i o n Configuration files are convertible
pr ot ec t i o n pack ag e VE> Forcing and disarming of output relays
Each of the six elements can be used as: Fault simulator
f< or f> (over- and Six Elements voltage Graphical display of tripping characteristics
underfrequency supervision) asymme try super vision 8 languages selectable within the relay
 df/dt (ROCOF) 
Under- and overvoltage in
Rate of change of frequency positive phase sequence system, Co m m u n i c at i o n o p t i o n s
 (f< and df/dt) or (f> and df/dt) overvoltage in negative phase IEC 61850, IEC 60870-5-103, Profibus DP
Combination of over-, under- and sequence system IEC60870-5-104
rate of change of frequency (ROCOF) Modbus RTU and/or Modbus TCP
(f< and DF/DT) or (f> and DF/DT) P ow e r Q uali t y DNP 3.0 (RTU, TCP, UDP)
Combination of over-, under- and THD-protection SCADApter for Retrofit
increase of frequency
Delta Phi (Vector surge) Su pe rv i s i o n IT S ecu r i t y
Voltage transformer supervision Menu for the activation of BDEW-
SIX E le m e n t s vo ltag e Trip circuit supervision Whitepaper-compliant security settings
pr ot ec t i o n CBF via position indicators (e. g. hardening of interfaces)
Under- and overvoltage IT Security Logger
Programmable time dependent r eco r d e r s Syslog (to centralized server)
undervoltage tripping characteristic Disturbance recorder: 120 s non volatile Encrypted connection with Smart view
Wattmetric Ground Fault Protection Fault recorder: 20 faults
Event recorder: 300 events Ad d i t i o nal h i g h li g h t s
S li d i n g - m e an -sq uar e Trend recorder: 4000 non volatile entries Plausibility checks
su pe rv is i o n Status display
Adjustable (VDE-AR 4105) PC To o l s Comprehensive measured values
Setting and analyzing software and statistics
FRT (LRVT ) Smart view for free Masking of unused functions
Adjustable LVRT-profiles Including page editor to design own pages Multi-Password-Level
Optionally AR-controlled
Lo g i c Co n t r o l
Fle xi b le Fo u r t h Vo ltag e Up to 80 logic equations for protection, One breaker
m e a su r i n g i n pu t control and monitoring Breaker wear
2 elements VE> or VX (for Synch Check)
T i m e s y n ch r o n i sat i o n
*5 mHz from 45-55 Hz SNTP, IRIG-B00X, Modbus,
DNP 3.0, IEC 60870-5-103/-104
Released

MRU4 Voltage and


Frequency Relay

Fun c tional over vie w


Elements ANSI
Protective Functions
V>, V<, V<(t) under- and overvoltage protection, programmable time dependent
6 27, 59
undervoltage tripping characteristic
FRT (optional coordination with AR-feature) 1 27 (t, AR)
Synchronism check 1 25
Each of the six frequency protection elements can be used as: 6
f< or f> (over- and under frequency supervision) 81U/O
df/dt rate of change of frequency (ROCOF) 81R
(f< and df/dt) or (f> and df/dt) combination of over-, under- and rate of change of frequency (ROCOF)
(f< and DF/DT) or (f> and DF/DT) combination of over-, under- and increase of frequency
Delta Phi (Vector surge) 78
VE, residual voltage protection 2 59N
Voltage asymmetry supervision (V012)
V1, under and overvoltage in positive phase sequence system 6 47
V2, overvoltage in negative phase sequence system
ExP, External alarm and trip functions 4
10-Minutes-Mean-Square-Sliding Supervision: adjustable according to VDE-AR 4105

Control and Logic


Control: Position indication, supervision time management and interlockings for 1 breaker
Logic: Up to 80 logic equations, each with 4 inputs, selectable logical gates, timers and memory function

Supervision Functions
CBF, circuit breaker failure protection (via position indicators) 1 62BF
TCS, trip circuit supervision 1 74TC
VTS, voltage transformer supervision by comparing phase and residual voltages 1 60FL
VTS, fuse failure protection via digital input 1 60FL
THD supervision

www.woodward.com
Released

Fun c tional over vie w in ANSI form

Option

1(0)

MRU4
MET (Measured and
calculated values)

delta phi
74 TC LVRT 62BF

25
VE

V1

3(4)
Recorders:

SER (Event)
47 27 59 59N 81 U/O 81R 60FL 78
DDR (Disturbance)

DFR (Fault)

Statistic
CLK (IRIG-B00X) Control LGC (Programmable Logic)
Trend
SNTP Switchgear Wear Intertripping

Option Standard

APPROVALS Connec tions ( Exa m p le)

certified regarding UL508


(Industrial Controls)

certified regarding
CSA-C22.2 No. 14
(Industrial Controls)

certified by EAC
(Eurasian Conformity)

Type tested (and certified)


regarding IEC60255-1

Component certificate regarding


the German grid code standard
VDE-AR-N 4110 (2018-11)

KESCO

(Declaration of Identity) Complies with “Engineering Recommendation G99 Issue 1 Amendment 3 – July 2018”.
Complies with IEEE 1547-2003.
Type Approval Certificate from Amended by IEEE 1547a-2014.
CQC China Complies with ANSI C37.90-2005.
Released

MRU4 Voltage and


Frequency Relay
19 “ Variants Available! **

O rder form mrU4

Voltage and Frequency supervision MRU4 -2 A 0 http://wwdmanuals.com/hpt-2


Version 2 with USB, enhanced communication and user options
Digital Binary Large CO ntac t:
Housing
Inputs output relays display
8 6 B1 -
North & Central America
Hardware variant
Phone: +1 970 962 7272
Standard
+1 208 278 3370
Housing and mounting
E-mail: [email protected]
Housing suitable for door mounting A
Housing suitable for 19” rack mounting ** B
South America
Communication protocol
Phone: +55 19 3708 4760
Without protocol A*
E-mail: [email protected]
Modbus RTU, IEC 60870-5-103, DNP3.0 RTU | RS485/terminals B*
Modbus TCP, DNP 3.0 TCP/UDP, IEC 60870-5-104 | Ethernet 100 MB/RJ45 C*
Europe
Profibus-DP | optic fiber/ST-connector D*
Phone (Kempen): +49 2152 145 331
Profibus-DP | RS485/D-SUB E*
Phone (Stuttgart): +49 711 78954 510
Modbus RTU, IEC 60870-5-103, DNP 3.0 RTU | optic fiber/ST-connector F*
E-mail: [email protected]
Modbus RTU, IEC 60870-5-103, DNP 3.0 RTU | RS485/D-SUB G*
IEC 61850, Modbus TCP, DNP 3.0 TCP/UDP, IEC 60870-5-104 | Ethernet 100MB/RJ45 H*
Middle East & Africa
IEC 60870-5-103, Modbus RTU, DNP 3.0 RTU | RS485/terminals
I* Phone: +971 2 678 4424
Modbus TCP, DNP 3.0 TCP/UDP, IEC60870-5-104 | Ethernet 100 MB/RJ45
IEC 61850, Modbus TCP, DNP 3.0 TCP/UDP, IEC 60870-5-104 | Optical Ethernet 100MB/LC duplex connector K* E-mail: [email protected]
Modbus TCP, DNP 3.0 TCP/UDP, IEC 60870-5-104 | Optical Ethernet 100MB/LC duplex connector L*
IEC 60870-5-103, Modbus RTU, DNP 3.0 RTU | RS485/terminals Russia
T* Phone: +49 711 78954 515
IEC 61850, Modbus TCP, DNP 3.0 TCP/UDP, IEC60870-5-104 | Ethernet 100 MB/RJ45
Harsh Environment Option E-mail: [email protected]
None A
China
Conformal Coating B
Phone: +86 512 8818 5515
Available menu languages (in every device)
E-mail: [email protected]
English / German / Spanish / Russian / Polish / Portuguese / French / Romanian
India
* Within every communication option only one communication protocol is usable.
Smart view can be used in parallel via the Ethernet interface (RJ45). Phone: +91 124 4399 500
The parameterizing- and disturbance analyzing software Smart view is included in the delivery of HighPROTEC devices.
E-mail: [email protected]

ASEAN & Oceania


Phone: +49 711 78954 510
E-mail: [email protected]
Subject to alterations, errors excepted.
For more information please contact:

Voltage inputs 4 (0– 800 V) with automatic CT Disconnect


Digital inputs Switching thresholds adjustable via software
Power supply Wide range power supply
24 VDC – 270 VDC / 48 VAC – 230 VAC (−20/+10%)
Terminals All terminals plug type
Mounting Door mounting
Type of enclosure (Front) IP54
Dimensions of housing 19“ flush mounting: 141.5 mm × 173 mm × 209 mm
(W × H × D) 5.571 in. × 6.811 in. × 8.228 in.
|

Door mounting: 141.5 mm × 183 mm × 209 mm


DOK-FLY-MRU4-2E_Rev. K

5.571 in. × 7.205 in. × 8.228 in.


Weight (max. components) approx. 2.4 kg