Liebert® EXS

from 10 to 80 kVA

Optimized and integrated


three-phase UPS solution
with high efficiency
power protection
Liebert® EXS from 10 to 80 kVA

About Vertiv™
Vertiv brings together hardware, software, analytics and ongoing services to ensure its customers’ vital
applications run continuously, perform optimally and grow with their business needs. Vertiv solves the
most important challenges facing today’s data centers, communication networks and commercial and
industrial facilities with a portfolio of power, cooling and IT infrastructure solutions and services that
extends from the cloud to the edge of the network. Headquartered in Columbus, Ohio, USA, Vertiv
employs around 20,000 people and does business in more than 130 countries. For more information,
and for the latest news and content from Vertiv, visit Vertiv.com.

Vertiv.com

OUR PURPOSE
We believe there is a better way to meet the world’s accelerating demand for data - one driven by passion and innovation.

OUR GLOBAL PRESENCE


Manuf. and Assembly Locations 19
Service Centers 270+
Service Field Engineers 2,700+
Technical Support/Response 330+
Customer Experience Centers/Labs 17

US AND CANADA LATIN AMERICA EUROPE, MIDDLE EAST AND ASIA PACIFIC
Manuf. and Assembly Locations 7 Manuf. and Assembly Locations 1 AFRICA Manuf. and Assembly Locations 6
Service Centers 120+ Service Centers 20+ Manuf. and Assembly Locations 5 Service Centers 60+
Service Field Engineers 850+ Service Field Engineers 300+ Service Centers 70+ Service Field Engineers 950+
Technical Support/Response 120+ Technical Support/Response 25+ Service Field Engineers 600+ Technical Support/Response 90+
Customer Experience Centers/Labs 4 Customer Experience Centers/Labs 2 Technical Support/Response 95+ Customer Experience Centers/Labs 5
Customer Experience Centers/Labs 6
Liebert® EXS from 10 to 80 kVA
Compact design and improved
performances
The new Liebert® EXS is a monolithic 97,00%
transformer-free UPS which brings
exceptional features for mission-critical 96,50%
applications. Its extraordinary double
conversion efficiency up to 96.2% 96,00%
ensures remarkable operational cost
savings, reducing both the Total Cost of 95,50%
Ownership (TCO) and the environmental
impact. 95,00%
At the same time, with its unity
output power factor and high power 94,50%
density, Liebert EXS is able to provide
the utmost active power possible 94,00%
in a compact footprint. In fact, its 20% 30% 40% 50% 60% 70% 80% 90% 100%
improved design reduces its footprint to
a minimum, providing continuous power
Liebert EXS 10-20 kVA efficiency curve
protection with optimized internal
runtime in a standalone solution, making
the Liebert EXS perfect for both IT
installations and other mission critical
applications, such as transportation,
emergency lighting, healthcare, retail and
government facilities.

FEATURES AND CENTRAL POWER SUPPLY SYSTEM (CPSS)


PERFORMANCES Liebert EXS can be used for CPSS applications* as defined in
the EN 50171 standard, and is hence capable of supplying the
•• Output power factor up to 1 necessary emergency power to essential safety equipment.
•• Double conversion efficiency In fact, the unit can be used to power emergency escape
up to 96.2% lighting in case of normal supply failure and may also be
•• ECO mode efficiency up to suitable for powering other safety systems such as automatic
99% fire extinguishing installations, signaling safety installations and
smoke extraction equipment.
•• Compact footprint with
* Subject to additional prescriptions
multiple internal runtime
configurations (10-60 kVA)
•• Available in 3/3 and 3/1
versions (10-20 kVA) RAILWAYS APPLICATIONS
•• Integrated maintenance Liebert EXS can be used for railways applications as defined
bypass in the EN 50121 standard, and it's hence capable of supplying
•• Integrated input and output power to specific systems in urban stations and ensure high
breakers/switches reliability to critical buildings.
In fact, the unit can be used to power on passenger information
•• Parallel capability for capacity
panels, safety signaling equipment, ticket machines as well as
and redundancy
IT rooms and administration and control offices.

3
Liebert® EXS from 10 to 80 kVA

Flexibility

To ensure superior protection for critical Integrated Autonomy (10-60 kVA) Full Galvanic Isolation
loads, the Liebert® EXS range has been Liebert EXS offers integrated full galvanic
Liebert EXS provides an optimized
designed to optimize specific rating isolation, meaning that an isolation
integrated autonomy which results in
requirements, thus enhancing flexibility transformer may be housed inside the
back up times in a compact footprint.
and installation space needs. UPS cabinet. This greatly reduces the
Its internal architecture is able to house
Liebert EXS’s flexibility is further up to four battery strings, further system footprint, thus providing space
enhanced through: optimizing integrated autonomy and saving advantages.
••Single and three phase output delivering the added advantage of The transformer may be connected to
configurations up to 20 kVA virtually eliminating the need for an the input or to the output of the UPS,
••Integrated parallel capability up to 4 external battery cabinet. providing:
units This furthermore reduces installation ••Full galvanic isolation for medical and
••Common or distributed battery bank costs and minimizes the demand on other critical applications
••Internal and external battery physical space. In addition, Liebert EXS’s ••Installation with two independent
configurations for optimized back up powerful battery charger ensures rapid input sources (with different neutrals)
time management recharge, increasing its ability to manage ••Installation in distribution without
••Casters for easy UPS repositioning longer back up times. neutral.

Output Configuration EXS 10-20 kVA with EXS 10-20 kVA with EXS 30-40 kVA with EXS 60 kVA with EXS 80 kVA
integrated battery integrated battery strings integrated batteries integrated batteries
Liebert EXS models up to 20 kVA can (up to two strings) (up to four strings)
be configured on-site to deliver three
(3/3) or single (3/1) phase output giving UPS UPS UPS UPS

it the flexibility to adapt to changes in


1300
1300

1600

1600

1600
UPS
installation environments. Battery Battery
Battery Battery

VERTIV™ TRELLIS™
650 650
750 850 850
335 242 335 440 600 600

Liebert EXS architecture


Vertiv Trellis platform is a
real-time infrastructure optimization
In The Field
platform that enables the unified
Parallel Ready The loop parallel connection used in
management of data center IT and
paralleling the system delivers ultimate
facilities infrastructure. Liebert EXS can be connected with up
The Vertiv Trellis platform software reliability and eliminates the possibility
to four units in parallel. A single unit
can manage capacity, track of a single point of failure, ensuring
can be upgraded to parallel operation
inventory, plan changes, visualize perfect load sharing and fast detection
via easy to modify software settings,
configurations, analyze and calculate of any variation in the system status.
allowing the system to be customized for
energy usage, and optimize cooling
and power equipment as well as
the requested configuration.
enable for virtualization. Automatic AC Bypass
The Vertiv Trellis platform monitors
AC Normal AC Normal AC Normal AC Normal
the data center, providing a
thorough understanding of system
dependencies to help IT and
facilities organizations keep the data
center running at peak performance.
This unified and complete solution,
delivers the power to see the real
situation in your data center, make
the right decision and take action
with confidence.
Load

Liebert EXS - Parallel configuration

4
Communication
Liebert® EXS features a multi-lingual Serviceability This architecture considerably minimizes
LCD user interface allowing close the time needed for repairs and
The architecture of the Liebert EXS is
control and monitoring of system status optimizes serviceability.
designed to optimize installation and
and performance. The UPS offers the Liebert EXS also comes equipped with
simplify service with its easily removable
following communication features: casters to facilitate ease of movement
power assembly.
••Voltage-free contacts and relocation.
••Intellislot for SNMP, Modbus or Relay
communication
••USB interface
These communication capabilities make
Liebert EXS compatible with any
building management system.

Software Connectivity
Vertiv™ shutdown software offering
prevents unexpected server shutdowns
and minimizes downtime warning of
pending power losses and initiating
safe shutdown of operating systems
if required. Vertiv Nform™ network
communications system enables
customers to leverage the distributed
monitoring capabilities of network
connected equipment, providing
centralized management of distributed
systems. Connectivity card Liebert EXS 10 - 80 kVA

Vertiv LIFE™ Services Remote Diagnostic and Preventive Monitoring


Vertiv's service program is designed to First Time Fix Rate Fast Incident Response
ensure that your critical power protection Vertiv LIFE Services allow for immediate
Pro-active monitoring and data
system is maintained in an optimum state definition of the best course of action,
measuring ensure that when our
of readiness at all times. as a result of the regular communication
customer engineers are dispatched on-
The Vertiv LIFE™ Services remote between your Liebert EXS system and
site, they arrive prepared for first time
diagnostic and preventive monitoring our Vertiv LIFE Services centers.
resolution.
service provides early warning of UPS
conditions and out of tolerances. Proactive Analysis Reporting
This allows effective proactive
From Vertiv LIFE Services centers, our You will receive a comprehensive
maintenance, fast incident response
experts proactively analyze the data and report detailing the working order of
and remote trouble shooting, giving
trends of your equipment, to recommend your equipment and its operational
customers complete security
actions to ensure their best performance. performance.
and peace of mind.
With Vertiv LIFE Services you will benefit
Minimized Total Cost of Ownership of
from:
Your Equipment
Uptime Assurance The continuous monitoring of all relevant
parameters in turn maximizes unit
Constant monitoring of UPS parameters,
performance, reduces on-site maintenance
thus maximizing the system’s availability.
and extends the life of your equipment.

5
Liebert® EXS from 10 to 80 kVA

Liebert® EXS Specifications

Technical Characteristics

Ratings (kVA) 10 15 20 30 40 60 80

Input

Nominal input voltage (V) 380/400/415 (three-phase + N + PE)

Input voltage range without battery discharge (V) 173 to 498* 228 to 475*

Nominal frequency (Hz) 50/60

Input frequency range (Hz) 40 to 70

Input power factor at full load (kW/kVA) 0.99

Current THD at full linear load (THDI%) ≤ 3%*

Bypass voltage tolerance (%) selectable from +20 to -40

Bypass frequency tolerance (%) ±20 (±10 selectable)

Battery

Battery blocks per string 24-40* 24-40*

Voltage temperature compensation (mV/°C/Cell) -3.0

Battery charger max. current (A) 13 12.5 25

Output
380/400/415 (three-phase + N + PE) or
Nominal output voltage (V) 380/400/415 (three-phase + N + PE)
220/230/240 (single-phase + N + PE)

Nominal output frequency (Hz) 50/60

Maximum active power (kW) 10 15 20 30 40 60 80

THDv at full linear load (%) 2

105% for 60 min; 125% for 5 min; 150% for 1 min; >150% 105% for 60 min; 125% for 10 min; 150% for 1 min; >150%
Inverter overload capacity
for 200ms for 200ms

Double conversion efficiency Up to 96.2%

ECO mode efficiency (%) Up to 99%

Dimensions and weight


335 x 650 x 1300 (standard version)
Dimensions (W x D x H) mm 440 x 750 x 1600 600 x 850 x 1600 600 x 850 x 1600
577 x 650 x 1300 (extended version)

Net/Shipping weight (excluding battery) kg 85/115 (standard version) 200/250 215/265 230/270

Net/Shipping weight (including 2*32 batteries) kg 285/315 (standard version) 600/650 700/750 NA

General

Noise at 1 m (dBA) ≤58 <60 <60

Maximum altitude 1500 m without derating (max. 3000 m)

Operating Temperature (°C) up to 50* up to 40

Protection level IEC (60529) IP20

General and safety requirements for UPS EN/IEC/AS 62040-1

EMC requirements for UPS EN/IEC/AS 62040-2

UPS classification according to CEI EN 62040-3 VFI-SS-111

* Conditions apply

6
Customer Experience Center
Vertiv™ state-of-the-art Customer complete power systems, with the added ••
Demo - carried out on new products to
Experience Center located in Castel possibility of the customer’s switchgear demonstrate UPS performance
Guelfo (Bologna - Italy), enables support systems being connected, thus ••
Standard - validation test showing
our customers to experience guaranteeing smooth, rapid installation UPS standard technical performances
first-hand a wide variety of data and commissioning of large power in compliance with UPS catalogue and
center technologies, supported by systems. IEC 62040-3 standards
constant consultation from R&D and Testing is also customized based on ••
Customized - session tailored
engineering specialists. the complexity, size and number of UPS to validating customer’s specific
components in the configuration. technical performance needs.
Customers visiting the center will Our Customer Experience Center offers
be able to witness pre-installation three validation experiences:
demonstrations, covering the technical
performance, interoperability and
efficiency of Vertiv UPS systems
under real field conditions. These
processes can be experienced from
the facility’s control room, where real-
time performance measurements and
reporting will be available while providing
full visibility of the demonstration area.
The center can host simultaneous tests
at full load of up to 4000 A.

The customer validation area specifically


dedicated to UPS consists of four
testing stations, each one providing
up to 1.2 MVA of capacity. Testing
includes individual modules, as well as

7
Vertiv.com | Vertiv Infrastructure Limited, George Curl Way, Southampton, SO18 2RY, VAT Number: GB188146827
© 2019 Vertiv Group Corp. All rights reserved. Vertiv™ and the Vertiv logo are trademarks or registered trademarks of Vertiv Group Corp. While every precaution has been taken to ensure accuracy and completeness herein, Vertiv Group Corp. assumes no
responsibility, and disclaims all liability, for damages resulting from use of this information or for any errors or omissions. Specifications are subject to change without notice.

MKA4L0UKEXS Rev.4-07-2019

You might also like