0% found this document useful (0 votes)
224 views

Sensonode Parker

Uploaded by

Edu Zamalloa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
224 views

Sensonode Parker

Uploaded by

Edu Zamalloa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 48

Condition Monitoring and Diagnostic Solutions

SensoNODE™ Sensors and Software


Sensors, Software, and Accessories
Catalog 3864 USA | March 2019
Quick Coupling Division Locations

Minneapolis, MN Grantsburg, WI

Chetek, WI Union City, PA

WARNING
FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS
CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE.

• This document and other information from Parker Hannifin Corporation, its subsidiaries and authorized distributors
provide product or system options for further investigation by users having technical expertise.

• The user, through its own analysis and testing, is solely responsible for making the final selection of the system and
components and assuring that all performance, endurance, maintenance, safety and warning requirements of the
application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or
its subsidiaries or authorized distributors.

• To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon
data or specifications provided by the user, the user is responsible for determining that such data and specifications are
suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

Offer of Sale
The items described in this document are hereby offered for sale by Parker Hannifin Corporation, its subsidiaries or its
authorized distributors. This offer and its acceptance are governed by the provisions stated in the “Offer of Sale.”

© 2018, Revised September 2018, Parker Hannifin Corporation, All Rights Reserved.
2 Parker Hannifin Corporation
Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Mobile App


Table of Contents
Introduction.................................................................. 4-5
Product Comparison....................................................... 6
Route-Based Monitoring - SensoNODE™ Blue.................... 7
Pressure Sensors............................................................. 8-9
Temperature Sensors................................................... 10-11
Humidity Sensors......................................................... 12-13
Flexible Displacement Sensors.................................... 14-15
Analog Connector......................................................... 16-17
ServiceJunior™ CONNECT........................................... 18-19
Wired Power Supply........................................................... 20
Voice of the Machine™ Mobile App.................................. 21-23
Continuous Remote Monitoring - SensoNODE™ Gold.... 24-25
Pressure Sensors......................................................... 26-27
Temperature Sensors................................................... 28-29
Humidity Sensors......................................................... 30-31
Current Sensors........................................................... 32-33
Flexible Displacement Sensors.................................... 34-35
Vibration Sensors......................................................... 36-37
Analog Connector......................................................... 38-39
Gateway System............................................................ 40-41
Wired Power Supply............................................................42
Voice of the Machine™ Cloud Software...................................43
Voice of the Machine™ Edge Software....................................44
Accessories..................................................................... 45-46
Notes.......................................................................................47

Cloud

3 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Parker’s IoT-Empowered Solutions

The Internet of Things (IoT) has changed the way manufacturing works, and you can’t afford to be left
behind. Global competitiveness drives companies to find new ways to improve efficiency and product
quality, and incorporating IoT-enabled solutions into your operations ensures your company is moving
forward.

Traditional condition monitoring means taking measurements on certain pieces of equipment or


processes one at a time, either for diagnostics or performance analysis. While reliable, it can be an
inaccurate, labor-intensive process that takes up valuable man-hours and creates potentially
dangerous situations for workers…in short; it costs companies time and money.

Parker’s SensoNODETM Sensors and Voice of the Machine™ Software are IoT-empowered solutions
that create new, advanced condition monitoring possibilities to reduce downtime and decrease mainte-
nance costs, helping you to maintain production and improve efficiency.

Voice of the Machine is a centralized strategy to ensure standardization across all Parker
IoT-empowered products. Voice of the Machine solutions assure you of component-level
IoT that is interoperable, secure, scalable and easy-to-use.

Parker’s advanced condition monitoring solutions listen to the


Voice of the Machine, allowing you to:
• Reduce your risk, maintenance costs, and unplanned downtime
• Uncover operational and performance improvements
• Make informed, more confident decisions and enjoy greater peace of mind
• Leverage Parker’s expertise to employ easy, cost-effective condition monitoring

4 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Streamline Your Work with Advanced
Condition Monitoring and Diagnostics
Advanced condition monitoring replaces the laborious, time-consuming process of walking from asset
to asset, checking manual gauges, taking hand-written notes, and then spending the time to crunch
those numbers.

Wirelessly get measurements without interrupting production.


• Identify issues before they escalate • Avoid dangerous situations
• Reduce downtime • Make better, more informed decisions
• Decrease maintenance costs • Improve labor efficiency

When used together, SensoNODE Sensors and Voice of the Machine Software create an advanced
condition monitoring solution that delivers vital measurement data to help drive optimal tactical,
operational, and strategic decisions, leading to maximum uptime.

Route-Based Monitoring - No network required Continuous Remote Monitoring - Network-based


(SensoNODE Blue and Mobile App) (SensoNODE Gold and Cloud/Edge)
• Short-term monitoring when you need it • Long-term and immediate health of machines
• Aids diagnostic efforts and processes are viewable around the globe
• Take measurements from individual machines • Ideal for environments where assets are mission
• Wireless solution for on-site monitoring critical, and shutdowns are costly
• Export recorded measurements • User selectable measurement data storage
• Remote solution accessible anywhere, anytime
• Get notified automatically of discrepancies

5 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Condition Monitoring Solutions
SensoNODE Blue SensoNODE Gold SensoNODE Gold
SensoControl and Mobile App and Edge and Cloud

Primary Application
Wireless Continuous Remote Monitoring √ √
Wireless Route-Based Monitoring √
Diagnostics √ √
Communication Method
900 MHz Wireless √ √
Bluetooth Low Energy (BLE) √
Wires √
Key Features
Alert Notifications - Text, Email √ √
In-Use Alarms √ √ √
Export and Share Data √ √ √ √
Recordings √ √ √ √
View Historical Data √ √
Configurable Dashboards √ √ √
Functions or Calculations √ √ √ √
Configurable Units of Measure √ √ √ √
Multiple Visualizations √ √ √ √
Viewable on Multiple Devices √* √ √
Add Sensors Instantly √ √ √ √
Fastest Measurement Rate 1 millisecond ** 1 second 20 seconds 20 seconds
Pressure Spike and Drop Capturing √
Synchronization of Measurement Inputs √
Battery Life Use Dependent Rate Dependent Rate Dependent Rate Dependent
FCC, IC, &/or CE Certified √ √ √ √
IP Rating IP67/IP64/IP65*** IP65 IP65 IP65
Data Storage
Cloud √ √
Local Server √
Mobile Device √
Handheld Meter √
Interface
Desktop/Laptop √ √ √
Mobile App √
Handheld Meter √
Other
Software License √
Optional Cellular Subscription √
Internet/WiFi/LAN Required √ √
Collection Server Required √ √
Site Survey Required √ √

*In Broadcast Mode Only **0.1ms Available on ServiceMaster+ ***Varies with Handmeters
6 Parker Hannifin Corporation
Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Route-Based Monitoring and Diagnostics
Parker’s route-based monitoring and diagnostics allow workers to take instant measurements of
individual assets wirelessly, and record those measurements using their mobile device. Compared
to traditional, wired gauges, users spend less time getting measurements, and can avoid potentially
unsafe working conditions; e.g. monitoring mobile equipment.

Parker’s SensoNODE Blue Sensors and Voice of the Machine Mobile Software deliver an IoT solution
where hardware and software work together to provide measurements and diagnostics across multiple
applications and industries.

Ideal for quick, accurate diagnostics, SensoNODE Blue and Voice of the Machine help companies:

• Get accurate measurements


• Gather measurements from a distance without interrupting production
• Avoid potentially dangerous situations
• Diagnose issues quickly
• Improve work efficiency
• Share data direct from your mobile device

SensoNODE Blue Sensors and Voice of the Machine Software

SensoNODE Blue is Parker’s series of Voice of the Machine Mobile App allows users
Bluetooth-enabled sensors. Compact, energy- to receive measurements direct to their mobile
efficient, and wireless, they are designed devices. The app compiles the data and presents
to provide simple and useful solutions it in a way that makes sense to a user’s operation,
for diagnostic and condition monitoring allowing them to track data immediately, and
applications with mobile devices. SensoNODE receive user-defined alarms for unplanned con-
monitors asset measurements to help predict dition changes that may damage assets. Mapping
problems and prevent downtime. and dashboard functions allow you to customize
data visualization.
Why Blue?
• Accurate measurements Why Mobile App?
• Easy installation • Measurements delivered to your
• No network required mobile device
• Wireless installation removes challenges of • Easy-to-use interface
wired systems • Customizable dashboards
• No external power source required • Mapping function
• Ultra-low battery consumption for up to five • Set your own alarm thresholds of
years of battery life* measurements (min/max)
• Sealed sensor housing ideal for harsh • Alerted when outside of defined thresholds
environments • Name sensors so they are easily identifiable
• Compact lightweight design • Easy-to-understand trend charts
• LED indicators aid in identifying • Multiple users can access data from their
sensor status mobile device
• Export data for analysis, sharing, and
* Not continuous use retention

7 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Pressure

Features:
• Available in a variety of pressure ranges from
-14.5 psi to 8700 psi.
• User-definable measurement units (psi/bar)
for convenient and familiar data readings.
• Port options: Male NPT or SAE thread and EMA or
PD quick couplers for fast and easy connecting.
• Corrosion resistant materials for challenging
environments.
• Sensor also provides ambient temperature values.
• User selectable measurement and broadcast
intervals. Refer to Voice of the Machine Mobile App
for more information about capabilities
and modalities.

Sensor Technical Data

Housing Material Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate


Port 1/4” Male NPT 1/4” Male NPT -4 SAE -4 SAE -4 SAE -4 SAE
Wetted Parts Material 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless
and Nitrile and Nitrile and Nitrile and Nitrile
Measurement Range -14.5 to 14.5 psi 0-150 psi 0-1500 psi 0-3625 psi 0-5800 psi 0-8700 psi
(pressure) [-1 to 1 bar] [10 bar] [100 bar] [250 bar] [400 bar] [600 bar]
Max. Overload Pressure 29 psi 225 psi 2250 psi 5440 psi 8700 psi 13,050 psi
Burst Pressure 3x 4x 4x 4x 4x 4x
Accuracy (at 77°F/ 25°C) 1.5% 1.5% 1.5% 1.5% 1.5% 1.5%
Resolution .01 psi .1 psi 1 psi 1 psi 1 psi 1 psi
Measurement and Broadcast Interval User Selectable User Selectable User Selectable User Selectable User Selectable User Selectable
Response Time (min) 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec
Ambient Temperature* -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F
(battery limited) [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C]
Fluid Media Temperature -40°F to 185°F -40°F to 185°F -40°F to 185°F -40°F to 185°F -40°F to 185°F -40°F to 185°F
Range [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C]
Full Range Life Cycles > 1 million > 1 million > 1 million > 1 million > 1 million > 1 million
Certifications FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A CR123A CR123A CR123A CR123A CR123A
IP Rating IP65 IP65 IP65 IP65 IP65 IP65
Note: Consult QCD for other port options, pressure ratings, and port seal materials.
*Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-B)

8 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Pressure
Pressure Sensors
Part No.: SNPT2-10-B-4MP_catalog line dwg Rev No.
Part No.: SNPT2-100-B-4MO_catalog line drawing
Title: PRESSURE SENSOR (1500PSI)
Rev No.
A
Title: PRESSURE SENSOR (150PSI) A

D D

This line drawing is for:


SNPT2-10-B-4MP
SNHT2-10-B-4MP

H H

Part Number Pressure Rating psi [bar] Port D H


SNPT2-1-B-4MP -14.5 to 14.5 [-1 to1] 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm]
SNPT2-10-B-4MP 0-150 [10] 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm]
SNPT2-100-B-4MO 0-1500 [100] -4 SAE ø1.88” [48mm] 2.72” [69mm]
SNPT2-250-B-4MO 0-3625 [250] -4 SAE ø1.88” [48mm] 2.72” [69mm]
SNPT2-400-B-4MO 0-5800 [400] -4 SAE ø1.88” [48mm] 2.72” [69mm]
SNPT2-600-B-4MO 0-8700 [600] -4 SAE ø1.88” [48mm] 2.72” [69mm]
Quick Couplers
Part No.: SNPT2-EMA line drawing Rev No.
Part No.: SNPT2-PD line drawing Rev No.
Title:
Title:

D D

H = 3.84" H = 4.41"

H
H

Part Number Pressure Rating psi [bar] Port D H


SNPT2-100-B-4MO-EMA 0-1500 [100] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-250-B-4MO-EMA 0-3625 [250] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-400-B-4MO-EMA 0-5800 [400] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-600-B-4MO-EMA 0-8700 [600] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-100-B-4MO-PD 0-1500 [100] PD ø1.88” [48mm] 4.40” [112mm]
SNPT2-250-B-4MO-PD 0-3625 [250] PD ø1.88” [48mm] 4.40” [112mm]
SNPT2-400-B-4MO-PD 0-5800 [400] PD ø1.88” [48mm]
PX3-42H Thermistor Accuracy
4.40” [112mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For sales Max T. Error (°C) Typ T. Error (°C) Temperature Accuracy
information outside of these regions, please contact your Parker representative. 6
Temperature Measurement Error (°C)

2
How to Order:
1

0
10

20

30

40

50

60

70

80

90

110
15

25

35

45

55

65

75

85

95
-5

100
105
-40
-35
-30
-25
-20
-15
-10

0
5

Temperature (°C)

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

9 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Temperature

Features:
• User-definable measurement units (F°/C°)
for convenient and familiar data readings
• Port Options: Male NPTF and SAE
• Corrosion-resistant materials for challenging
environments.
• User-selectable measurement and broadcast
intervals. Refer to Voice of the Machine Mobile
App for more information about capabilities
and modalities.
• Available in unique foot and clamp designs
for quick attachment to pipe or hard tubing.

Sensor Technical Data

Housing Material Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate Nylon


Port 1/4” Male NPTF -4 SAE 1/4” Male NPTF -4 SAE Foot Clamp
Wetted Parts Material 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless Stainless Stainless
and Nitrile and Nitrile
Measurement Range -40°F to 230°F -40°F to 230°F -40°F to 230°F -40°F to 230°F -40°F to 257°F -40°F to 257°F
(Fluid Temperature) [-40°C to 110°C] [-40°C to 110°C] [-40°C to 110°C] [-40°C to 110°C] [-40°C to 125°C] [-40°C to 125°C]
Working Pressure 0-10k psi 0-9k psi 0-1500 psi 0-1500 psi N/A N/A
[0-700 bar] [0-630 bar] [0-100 bar] [0-100 bar]
Max. Overload Pressure 3x 3x 2x 2x N/A N/A
Burst Pressure 4x 4x 3x 3x N/A N/A
Accuracy (at 77°F/ 25°C) ±3.0% ±3.0% ±3.0% ±3.0% ±5.0% ±5.0%
Resolution (from 14°F to 120°F) 1°F [.56°C] 1°F [.56°C] 1°F [.56°C] 1°F [.56°C] 2°F [1.12°C] 2°F [1.12°C]
[-10°C to 44.8°C]
Measurement and Broadcast User Selectable User Selectable User Selectable User Selectable User Selectable Measurement Only (1
Intervals sec)
Response Time (minimum) 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec
Ambient Temperature (battery -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F
limited)* [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C]
Full Range Life Cycles > 1 million > 1 million > 1 million > 1 million > 1 million > 1 million
Certifications FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE
Battery (Panasonic is recommended CR123A CR123A CR123A CR123A CR123A CR2450
brand)
IP Rating IP65 IP65 IP65 IP65 IP65 IP65

Note: Consult QCD for other port options and port seal materials.
*Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-B)

10 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Temperature

Temperature Sensors – Ported


Part No.: SNT2-700-B-4MP_catalog line drawing Rev No.
Part No.: SNT2-700-B-4MO_catalg line drawing Rev No.
A
A
D
Title: TEMPERATURE SENSOR
Title: TEMPERATURE SENSOR

H H
L L

MO MP Probe

Part Number Fluid Temperature Range Port D H L


SNT2-700-B-4MO -40°F to 230°F [-40°C to 110°C] -4 SAE ø1.88” [48mm] 2.72” [69mm] 0.40” [10.16mm]
SNT2-700-B-4MP -40°F to 230°F [-40°C to 110°C] 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm] 0.40” [10.16mm]
SNT2-100-B-4MO-0335 -40°F to 230°F [-40°C to 110°C] -4 SAE/Probe ø1.88” [48mm] 2.72” [69mm] 3.35” [85mm]
SNT2-100-B-4MP-0335 -40°F to 230°F [-40°C to 110°C] 1/4” Male NPTF/Probe ø1.88” [48mm] 2.66” [68mm] 3.35” [85mm]
Temperature Sensors – Foot and Clamp
Part No.: SNT2-0-B-FT_catalog_drawing Rev No.
Title:

Part No.: Temp clamp catalog line drawing Rev No.


Title: TEMPERATURE CLAMP A

L
Part Number Fluid Temperature Range L H Optimal Clamping
SNT2-0-B-FT -40°F to 257°F [-40°C to 125°C] 2.42” [61.5mm] 2.31” [58.7mm] > Ø.25”+ [>Ø6.4mm]
SNT-0-B-CL-KB -40°F to 257°F [-40°C to 125°C] 5.24” [133.1mm] 3.06” [77.7mm] Ø.25” to Ø1.5” [Ø6.4mm-Ø38.1mm]
Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For UNG103F343F5 Thermistor Accuracy
Temperature Accuracy
sales information outside of these regions, please contact your Parker representative. Max T. Error (°C) Typ. T Error (°C)

4
Temperature Measurement Error (°C)

3.5

2.5

1.5

0 .5

How to Order: 0
110
100
105
-40
-35
-30
-25
-20
-15
-10

10

20

30

40

50

60

70

80

90
0
5

15

25

35

45

55

65

75

85

95
-5

Temperature (°C)

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

11 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Humidity

Features:
• 0-100% relative humidity.
• Ideal for ambient condition and inert
compressed gas monitoring applications.
• NPTF port to make plumbing and
connecting easier and faster.
• Optimal mounting orientation is vertical with
port facing down to prevent moisture collection.
• Sensor also provides ambient temperature values.
• User-selectable measurement and broadcast
intervals. Refer to the Voice of the Machine
Mobile App for more information about
capabilities and modalities.

Sensor Technical Data


Housing Material Polycarbonate
Port 1/4” Male NPTF
Wetted Parts Material Brass, Nitrile, Urethane, and GORE-TEX®
Measurement Range (Humidity) 0-100% RH
Working Pressure 0-150 psi [10 bar]
Max. Overload Pressure 150 psi Max [10 bar]
Burst Pressure 4x
Accuracy (77°F/25°C, 20% RH to 80% RH, at ambient pressure) ±5% RH Max
Resolution (at 77°F/25°C) 0.1% RH
Measurement and Broadcast Interval User Selectable
Response Time (from 33% to 75% RH) 10 secs
Ambient Temperature (battery limited)* -4°F to 158°F
[-20°C to 70°C]
Temperature Accuracy (from 14°F to 185°F [-10°C to 85°C]) ±1.0°F [±0.5°C]
Full Range Life Cycles > 1 million
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

*Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-B)

12 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Humidity

Humidity Sensors
Part No.: SNPT2-10-B-4MP_catalog line dwg Rev No.
Title: PRESSURE SENSOR (150PSI) A

This line drawing is for:


SNPT2-10-B-4MP
SNHT2-10-B-4MP

Part Number RH Range Port D H


SNHT2-10-B-4MP 0-100% 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For
sales information outside of these regions, please contact your Parker representative. RH Accuracy
Max. RH Error (±%) Typ. RH Error (±%)

10

9
RH Measurement Error (±%)

0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Relative Humidity (%)

Temperature Accuracy
Max. T Error (°C) Typ. T Error (°C)

1.2
Temperature Measurement Error (°C)

0.8

0.6

0.4

0.2

0
-40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100105110115120125
Temperature (°C)
How to Order:

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

13 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Flexible Displacement

Features:
• Magnetic base for tool free mounting.
• Threaded stud port provides alternative
mounting option where magnetic base is
not suitable.
• Soft, thin and conformable sensors.
• Reliable accurate measurements while being
strained up to 100% for millions of cycles.
• Resilient silicone rubber that can withstand
harsh environments.

Sensor Technical Data


Active Area Dimensions 50mm x 14mm 100mm x 14mm
Maximum Extension 100mm 200mm
Resolution ±0.1% strain FS (±50μm) ±0.1% strain FS (±100μm)
Sensitivity 0.026% strain FS (13μm) 0.026% strain FS (26μm)
Linearity ±1% FS ±1% FS
Hysteresis ±1% FS ±1% FS
Stiffness 0.15 N/mm 0.15 N/mm
Percent strain in 100ths of a percent of length of Percent strain in 100ths of a percent of length of
Measurement Outputs
active area; temperature in °C or °F active area; temperature in °C or °F
Sampling Rate 1Hz for standard configuration 1Hz for standard configuration
Ambient Temperatures -40°F to +185°F, [-40°C to +85°C] -40°F to +185°F, [-40°C to +85°C]
Full Range Life Cycles > 5 million > 5 million
IP Rating IP67 IP67

Transmitter Technical Data


Base Material Aluminum
Housing Material Polycarbonate
Measurement and Broadcast Interval User Selectable
Temperature Range with Wired Power -40�F-185�F
Temperature Range with Battery -4�F-158�F
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

14 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Flexible Displacement

Sensor Kit Sensors

Part Number Sensor Length (L) Sensor Width (W) Cable Length
EAPS-50HD 1.97” [50mm] 0.67” [17mm] 18” [457.2mm]
EAPS-100HD 3.94” [100mm] 0.67” [17mm] 18” [457.2mm]
Part Number Transmitter Sensors
SNES2-KIT-B-50 (1) SNES2-B (2) 50mm

Transmitter

Part Number Base Mounting Thread D H L


SNES2-B 1/4-28 UNF x 0.45” [11mm] 2.11” [54mm] 2.67” [68mm] 2.41” [61mm]
Note: Products in catalog are currently only for sale in the U.S., Canada and Europe.
For sales information outside of these regions, please contact your Parker representative.

How to Order:

HD

Sensor Type
HD: Heavy Duty

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

15 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Analog Connector

Features:
• Connects inline with any 4-20mA Sensor.
• Integrates hard wired sensors into wireless
Voice of the Machine Software.
• Does not require reprogramming of
existing control system
• Magnetic base for tool free mounting.
• Threaded stud port provides alternative
mounting options where magnetic
base is not suitable.
• Definable mapping feature in Voice of the
Machine Mobile App to present 4-20mA signal
in user defined units.
• Requires connection cable SCK-400-xx-xx
in conjunction with transmitter and
Transmitter Technical Data 4-20mA Sensor.
Base Material Aluminum
Housing Material Polycarbonate
Accuracy 0.5% (additive to
source)
Resolution 0.1%
Temperature Range with Wired Power -40�F-185�F
Temperature Range with Battery -4�F-158�F
Measurement and Broadcast Interval User Selectable
Full Range Life Cycles > 1 million
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

16 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Analog Connector

4-20mA Transmitter

Part Number Base Mounting Thread D H L


SN422-B 1/4-28 UNF x0.45” [11mm] 2.11” [54mm] 2.67” [68mm] 2.41” [61mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe.
For sales information outside of these regions, please contact your Parker representative.

Pin Assignment
PIN Connection Wire Color Transmitter Cable
1 No Connection Brown
2 4-20mA Signal In White
3 4-20mA Signal Out Blue
4 No Connection Black
5 No Connection Gray

M12 Connection Cable


Part Number Cable Length Plug-in Connector
SCK-400-02-45 6.5 ft [2m] M12 socket, straight
SCK-400-02-55 6.5 ft [2m] M12 socket, 90�
SCK-400-05-45 16 ft [5m] M12 socket, straight
SCK-400-05-55 16 ft [5m] M12 socket, 90�
SCK-400-10-45 32.5 ft [10m] M12 socket, straight
SCK-400-10-55 32.5 ft [10m] M12 socket, 90�

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

17 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoControlTM ServiceJunior™ CONNECT

Features:
• Wireless, remote readings
• Easy operation
• Hand-held digital pressure gauge
• Measure and display - pressure
• Backlit display
• User-adjustable pressure units
• Min/Max memory
• Battery life indicator
• Ranges for hydraulics and pneumatics
• Scanning rate of 10ms
• Fluid temperature: -4�F to 176�F
• Certifications: FCC, IC, CE

Why ServiceJunior Wireless?


Cover Color Code Digital pressure monitoring
Blue -14.5 to 230 psi (-1 to 16 bar) • Capture minimum/maximum pressure changes at a
Green 0 to 1500 psi (0 to 100 bar) rate of 10 ms
Orange 0 to 5800 psi (0 to 400 bar) • Digital readout more accurate than mechanical
Red 0 to 8700 psi (0 to 600 bar) • Exportable records and proof-of-work statements
• Set alarms, create/view trend graphs, create asset
records

Wireless operation
• Powered by Industrial Mobile Software
• Fast accurate readings
• No more wiring or hoses getting caught in machinery
• Line of sight is not needed to obtain measurement
• Allows users to be away from machinery while in use and
under full load, reducing safety risks
Scalable and expandable
• Increase or decrease the total number of gauges used
• No need to reconfigure wired infrastructure
• Works with SensoNODE™ Blue Sensors via Mobile App

18 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoControlTM ServiceJunior™ CONNECT
ServiceJunior CONNECT

\\\

ServiceJunior ServiceJunior ServiceJunior Overload


Resolution
CONNECT CONNECT CONNECT Measuring Range Pressure Accuracy
(psi)
(PD Coupler*) (EMA3 Coupler**) (1/4”NPT Port) (psi)
SCJR-0250-PD-BLE2 SCJR-0250-EMA-BLE2 SCJR-0250-4MP-BLE2 -14.5 to 230 psi (-1 to 16 bar) 460 0.1 0.5% FS
SCJR-1500-PD-BLE2 SCJR-1500-EMA-BLE2 SCJR-1500-4MP-BLE2 0 to 1500 psi (0 to 100 bar) 2,900 1 0.5% FS
SCJR-5800-PD-BLE2 SCJR-5800-EMA-BLE2 SCJR-5800-4MP-BLE2 0 to 5800 psi (0 to 400 bar) 11,600 1 0.5% FS
SCJR-8700-PD-BLE2 SCJR-8700-EMA-BLE2 SCJR-8700-4MP-BLE2 0 to 8700 psi (0 to 600 bar) 14,500 1 0.5% FS

Product Dimensions W D H L
ServiceJunior CONNECT 3.52” [89.40mm] 2.28” [57.91mm] 4.04” [102.61mm] 7.05” [179.07mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe.
For sales information outside of these regions, please contact your Parker representative.

Battery life is dependent upon wireless transmission rate:


1 second rate = 100 hours of battery life 2 second rate = 200 hours of battery life

* PD Couplers rated to 6,000 psi max


** EMA3 Couplers rated to 9,000 psi max
Note: To receive ServiceJunior with calibration certificate, add K- to the beginning of the part number. (i.e. K-SCJR-1500-PD)

Accessories
Part Number Description
PD240 PD Series Diagnostic Coupler
SCA-7/16-EMA-3 7/16 - 20UNF-2B female to M16X2.0 EMA3 female swivel
SCJA-1/4 7/16 - 20UNF-2B female to 1/4” NPT male adapter
PDH-19 19” PD Hose extension to be used with PD nipple
PDH-32 32” PD Hose extension to be used with PD nipple
SMA3-400 16” (400 mm) Hose assembly for EMA M16X2.0 interface
SCC-300 Storage case for three gauges and diagnostic adapters

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

19 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Blue Wired Power Supply

Features:
• Supplies continuous power to sensors.
• Used with IEC/UL 508 Class 2 power supply.
• Easy upgrade eliminates the need for
battery replacement.
• Extends temperature operating range over
batteries.
• FCC, IC, and CE certified when used with
SensoNODE products.

Technical Data
Part Number SNWP2-B
Wire Length 9.8 ft [3m]
Temperature Range -40�F-185�F
Input Power 5-36 Volts DC
Output Power 3 Volts DC
Connection Flying lead 24 AWG Wires
Form CR123A Battery

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

20 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Voice of the MachineTM Mobile App

Mobile App
Voice of the Machine Mobile App is used for diagnostics and condition monitoring for predictive
maintenance. The app allows users to connect to Parker’s SensoNODE™ Blue wireless sensors to gather
measurements for a wide range of fluid and gas applications.

Voice of the Machine Mobile App puts vital information in the palm of the user’s hand. It offers immediate
and historic trend information collected by SensoNODE™ Blue wireless sensors and presents it in a way
that makes sense to a user’s operation, providing the information needed to optimize asset performance.
Data can also be easily exported and shared.

Voice of the Machine Mobile App alerts users to unplanned condition changes that may damage components
and equipment. As levels rise above or fall below user-defined thresholds, users are alerted to these
events, giving them an opportunity to address potential issues that could harm the system over time,
helping to reduce unplanned downtime and increase productivity.

Capabilities:
• Mobile application designed for iOS and Android
• Connect and display SensoNODE Blue Sensors

Features:
• Intuitive design and user experience
• Auto recognition enables users to quickly add and
connect multiple sensors concurrently
• Easy readability of measurements with visualized data
in digital gauges and trend charts
• View immediate measurements that include current
values and minimum/maximum indicators in addition to
historical sensor information
• Configurable alarm thresholds with alerts when
thresholds are exceeded; monitoring continues while
sensors are unattended
• Customizable trend charts and dashboards
• Mapping function for pressure, 4-20mA and flexible
displacement sensors that correlates raw
measurements into your “specific” units
• Easily export and share data

21 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Voice of the MachineTM Mobile App

Compatibility:
• Requires iOS 9 or newer/Android 4.4 or newer

Languages:
• English

Supported Devices:
• iPhone (4S and newer)
• iPod Touch (5th Gen and newer)
• iPad 3, 4
• iPad Air and iPad Air 2
• iPad Mini (1st Gen and newer)
• iPad Pro
• Compatible with most Bluetooth Low
Energy (BLE) supported Android devices

22 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Voice of the MachineTM Mobile App

Sensor Inventory Measurement Detail


One touch access to sensors Focus on a single
that have been added to measurement with trend
your mobile device with their charts, digital gauge, alarm
latest measurements, alarm thresholds and other useful
status, and sensor features for the operational
mode - broadcasting professional.
or connected.

Sensor Setup Dashboard


Configure sensors with Simplify monitoring activities
individually programmed by grouping measurements
name, highlight color and that belong together and
modes of operation to suit compare the group’s trends
different use cases. and gauges.

Alarm Settings Record and Export


Define measurement Record and export
thresholds to get notified of measurements in CSV
important changes. Critical format for sharing with
thresholds are programmed peers or further analyzing
to sensor firmware for in other applications
exception monitoring (e.g. Excel).
between readings.

23 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Continuous Remote Monitoring
For more long-term condition monitoring
applications, continuous remote monitoring allows
you to track measurements to gauge the health
of your machines and processes. Whether you’re
at your desk or out visiting a customer, you can
monitor and collect data from multiple assets and
get alerts of deviations. This is ideal for large-scale
operations with production and assembly lines.

Parker’s Voice of the Machine Software and


SensoNODE Gold Sensors deliver a complete,
standalone solution that isn’t dependent on a
facility network or IT department. All you need is
an internet connection and browser to monitor your
asset measurements from anywhere.

With quick and simple data gathering from multiple
facilities, users can:
• Review data anywhere, anytime and make
better decisions
• Improve safety
• Get measurements without interrupting
production
• Monitor more assets and processes with
fewer staff
• Optimize machine performance and
service life
• Maintain production quality
• Immediate notification of deviations/
exceptions
• Analyze performance trends for indications
of pending failures

SensoNODE Gold and Voice of the Machine Software


Data Stream

SensoNODE Gold
Sensor Cloud and Edge
Edge Interface

24 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Sensors and Voice of the MachineTM Software
SensoNODE Gold is Parker’s series of networked, Voice of the Machine Cloud Software is Parker’s
wireless sensors that are developed for cloud-based continuous condition monitoring in-
continuous condition monitoring via the cloud terface that provides alerts, status, and analytics
or local enterprise applications. That means as for increased awareness of your processes and
long as you have an internet connection, you can assets.
get up-to-date measurements.
Why Cloud?
Why Gold? • Access to data anytime, anywhere
• Wireless sensors that are small in size • Easy to use web-based interface
• Simple sensor installation • No software download – no updates
• Provides accurate measurements • Receive alert notifications - email, text
• Place sensors at point of need message, or in-system
• Longer battery life • Visualize data in a way that makes most sense
• Longer range radio • Customize alerts, trend charts, and
• Durable construction for harsh environments dashboards
– IP65 rated • View measurement anomalies easily
• Support continuous improvement efforts with
trend data
• Multiple user access levels
• Remotely monitor multiple sites and sensors
• Export data

Voice of the Machine Edge Software


The Edge interface is designed to work seamlessly with a web browser-based user interface. Data is
ingested from virtually any industrial asset. The software allows you to run various applications utilizing
your data at the Edge, or send it securely to the Cloud for seamless enterprise integration.

Why Edge?
• App & Industrial Driver Marketplace • Easy to Use Graphical Programming Interface
• Security Monitoring • Industrial Device Connectivity
• Remote Device Management • Application Deployment
• 3rd Party Cloud Integration • Secure Access
• Private Marketplace

25 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Pressure

Features:
• Available in a variety of pressure ranges from
-14.5 psi to 8700 psi.
• User-definable measurement units (psi/bar)
for convenient and familiar data readings.
• Port options: Male NPT or SAE thread and EMA or
PD quick couplers for fast and easy connecting.
• Corrosion resistant materials for challenging
environments.
• Sensor also provides ambient temperature values.
• Configurable measurement and broadcast
intervals*. Refer to Voice of the Machine Cloud for
more information about capabilities and
modalities.

Sensor Technical Data

Housing Material Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate


Port 1/4” Male NPT 1/4” Male NPT -4 SAE -4 SAE -4 SAE -4 SAE
Wetted Parts Material 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless
and Nitrile and Nitrile and Nitrile and Nitrile
Measurement Range -14.5 to 14.5 psi 0-150 psi 0-1500 psi 0-3625 psi 0-5800 psi 0-8700 psi
(pressure) [-1 to 1 bar] [10 bar] [100 bar] [250 bar] [400 bar] [600 bar]
Max. Overload Pressure 29 psi 225 psi 2250 psi 5440 psi 8700 psi 13,050 psi
Burst Pressure 3x 4x 4x 4x 4x 4x
Accuracy (at 77°F/ 25°C) 1.5% 1.5% 1.5% 1.5% 1.5% 1.5%
Resolution .01 psi .1 psi 1 psi 1 psi 1 psi 1 psi
Response Time (min) 1 sec 1 sec 1 sec 1 sec 1 sec 1 sec
Ambient Temperature -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F
(battery limited)** [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C]
Fluid Media Temperature -40°F to 185°F -40°F to 185°F -40°F to 185°F -40°F to 185°F -40°F to 185°F -40°F to 185°F
Range [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C] [-40°C to 85°C]
Full Range Life Cycles > 1 million > 1 million > 1 million > 1 million > 1 million > 1 million
Certifications FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A CR123A CR123A CR123A CR123A CR123A
IP Rating IP65 IP65 IP65 IP65 IP65 IP65
Note: Consult QCD for other port options, pressure ratings, and port seal materials.
*Consult Subscription Agreement and Order Form or Parker QCD for any changes regarding data rates.
**Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-2)

26 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Pressure
Pressure Sensors
Part No.: SNPT2-10-B-4MP_catalog line dwg Rev No.
Part No.: SNPT2-100-B-4MO_catalog line drawing
Title: PRESSURE SENSOR (1500PSI)
Rev No.
A
Title: PRESSURE SENSOR (150PSI) A

D D

This line drawing is for:


SNPT2-10-B-4MP
SNHT2-10-B-4MP

H H

Part Number Pressure Rating psi [bar] Port D H


SNPT2-1-2-4MP -14.5 to 14.5 [-1 to1] 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm]
SNPT2-10-2-4MP 0-150 [10] 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm]
SNPT2-100-2-4MO 0-1500 [100] -4 SAE ø1.88” [48mm] 2.72” [69mm]
SNPT2-250-2-4MO 0-3625 [250] -4 SAE ø1.88” [48mm] 2.72” [69mm]
SNPT2-400-2-4MO 0-5800 [400] -4 SAE ø1.88” [48mm] 2.72” [69mm]
SNPT2-600-2-4MO 0-8700 [600] -4 SAE ø1.88” [48mm] 2.72” [69mm]
Quick Couplers
Part No.: SNPT2-EMA line drawing Rev No.
Part No.: SNPT2-PD line drawing Rev No.
Title:
Title:

D D

H = 3.84" H = 4.41"

H
H

Part Number Pressure Rating psi [bar] Port D H


SNPT2-100-2-4MO-EMA 0-1500 [100] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-250-2-4MO-EMA 0-3625 [250] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-400-2-4MO-EMA 0-5800 [400] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-600-2-4MO-EMA 0-8700 [600] EMA ø1.88” [48mm] 4.00” [101mm]
SNPT2-100-2-4MO-PD 0-1500 [100] PD ø1.88” [48mm] 4.40” [112mm]
SNPT2-250-2-4MO-PD 0-3625 [250] PD ø1.88” [48mm] 4.40” [112mm]
SNPT2-400-2-4MO-PD 0-5800 [400] PD ø1.88” [48mm]
PX3-42H Thermistor Accuracy 4.40” [112mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For sales Max T. Error (°C) Typ T. Error (°C)
Temperature Accuracy
information outside of these regions, please contact your Parker representative. 6
Temperature Measurement Error (°C)

How to Order: 0
10

20

30

40

50

60

70

80

90

110
15

25

35

45

55

65

75

85

95
-5

100
105
-40
-35
-30
-25
-20
-15
-10

0
5

Temperature (°C)

[FCC/IC]
3: 868 MHz [CE]

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

27 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Temperature
Features:
• User-definable measurement units (F°/C°)
for convenient and familiar data readings.
• Port Options: Male NPTF and SAE
• Corrosion-resistant materials for challenging
environments.
• Configurable measurement and broadcast
intervals*. Refer to Voice of the Machine Cloud
for more information about capabilities
and modalities.
• Available in unique foot design for quick
attachment to pipe or hard tubing.

Sensor Technical Data

Housing Material Polycarbonate Polycarbonate Polycarbonate Polycarbonate Polycarbonate


Port 1/4” Male NPTF -4 SAE 1/4” Male NPTF -4 SAE Foot
Wetted Parts Material 17-4 Stainless 17-4 Stainless 17-4 Stainless 17-4 Stainless Stainless
and Nitrile and Nitrile
Measurement Range -40°F to 230°F -40°F to 230°F -40°F to 230°F -40°F to 230°F -40°F to 257°F
(Fluid Temperature) [-40°C to 110°C] [-40°C to 110°C] [-40°C to 110°C] [-40°C to 110°C] [-40°C to 125°C]
Working Pressure 0-10k psi 0-9k psi 0-1500 psi 0-1500 psi N/A
[0-700 bar] [0-630 bar] [0-100 bar] [0-100 bar]
Max. Overload Pressure 3x 3x 2x 2x N/A
Burst Pressure 4x 4x 3x 3x N/A
Accuracy (at 77°F/ 25°C) ±3.0% ±3.0% ±3.0% ±3.0% ±5.0%
Resolution (from 14°F to 120°F)[-10°C 1°F [.56°C] 1°F [.56°C] 1°F [.56°C] 1°F [.56°C] 2°F [1.12°C]
to 44.8°C]
Response Time (minimum) 1 sec 1 sec 1 sec 1 sec 1 sec
Ambient Temperature -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F -4°F to 158°F
(battery limited** [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C] [-20°C to 70°C]
Full Range Life Cycles > 1 million > 1 million > 1 million > 1 million > 1 million
Certifications FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A CR123A CR123A CR123A CR2450
IP Rating IP65 IP65 IP65 IP65 IP65
Note: Consult QCD for other port options, pressure ratings, and port seal materials.
*Consult Subscription Agreement and Order Form or Parker QCD for any changes regarding data rates.
**Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-2)

28 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Temperature

Temperature Sensors – Ported


Part No.: SNT2-700-B-4MP_catalog line drawing Rev No.
Part No.: SNT2-700-B-4MO_catalg line drawing Rev No.
A
A
D
Title: TEMPERATURE SENSOR
Title: TEMPERATURE SENSOR

H H
L L

Part Number Fluid Temperature Range Port D H L


SNT2-700-2-4MO -40°F to 230°F [-40°C to 110°C] -4 SAE ø1.88” [48mm] 2.72” [69mm] 0.40” [10.16mm]
SNT2-700-2-4MP -40°F to 230°F [-40°C to 110°C] 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm] 0.40” [10.16mm]
SNT2-100-2-4MO-0335 -40°F to 230°F [-40°C to 110°C] -4 SAE/Probe ø1.88” [48mm] 2.72” [69mm] 3.35” [85mm]
SNT2-100-2-4MP-0335 -40°F to 230°F [-40°C to 110°C] 1/4” Male NPTF/Probe ø1.88” [48mm] 2.66” [68mm] 3.35” [85mm]
Temperature Sensors – Foot
Part No.: SNT2-0-B-FT_catalog_drawing Rev No.
Title:

L
Part Number Fluid Temperature Range L H Optimal Clamping
SNT2-0-2-FT -40°F to 257°F [-40°C to 125°C] 2.42” [61.5mm] 2.31” [58.7mm] > Ø.25”+ [>Ø6.4mm]

UNG103F343F5 Thermistor Accuracy


Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For Max T. Error (°C) Typ. T Error (°C) Temperature Accuracy
sales information outside of these regions, please contact your Parker representative.
4
Temperature Measurement Error (°C)

3.5

2.5

1.5

0 .5
How to Order: 0
110
100
105
-40
-35
-30
-25
-20
-15
-10

10

20

30

40

50

60

70

80

90
0
5

15

25

35

45

55

65

75

85

95
-5

Temperature (°C)

The products listed can expose you to chemicals including


Lead, which is known to the State of California to cause cancer,
and to cause birth defects or other reproductive harm.
[FCC/IC] For more information go to www.P65Warnings.ca.gov
3: 868 MHz [CE]

29 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Humidity

Features:
• 0-100% relative humidity.
• Ideal for ambient condition and inert
compressed gas monitoring applications.
• NPTF port to make plumbing and
connecting easier and faster.
• Optimal mounting orientation is vertical with
port facing down to prevent moisture collection.
• Sensor also provides temperature values.
• Configurable measurement and broadcast
intervals*. Refer to the Voice of the Machine
Cloud for more information about capabilities
and modalities.

Sensor Technical Data


Housing Material Polycarbonate
Port 1/4” Male NPTF
Wetted Parts Material Brass, Nitrile, Urethane, and GORE-TEX®
Measurement Range (Humidity) 0-100% RH
Working Pressure 0-150 psi [10 bar]
Max. Overload Pressure 150 psi Max [10 bar]
Burst Pressure 4x
Accuracy (77°F/25°C, 20% RH to 80% RH, at ambient pressure) ±5% RH Max
Resolution (at 77°F/25°C) 0.1% RH
Response Time (from 33% to 75% RH) 10 secs
Ambient Temperature (battery limited)** -4°F to 158°F
[-20°C to 70°C]
Temperature Accuracy (from 14°F to 185°F [-10°C to 85°C]) ±1.0°F [±0.5°C]
Full Range Life Cycles > 1 million
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65
*Consult Subscription Agreement and Order Form or Parker QCD for any changes regarding data rates.
**Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-2)

30 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Humidity

Humidity Sensors
Part No.: SNPT2-10-B-4MP_catalog line dwg Rev No.
Title: PRESSURE SENSOR (150PSI) A

This line drawing is for:


SNPT2-10-B-4MP
SNHT2-10-B-4MP

Part Number RH Range Port D H


SNHT2-10-2-4MP 0-100% 1/4” Male NPTF ø1.88” [48mm] 2.66” [68mm]
Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For sales information outside of
these regions, please contact your Parker representative.
RH Accuracy
Max. RH Error (±%) Typ. RH Error (±%)

10

9
RH Measurement Error (±%)

0
0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100
Relative Humidity (%)

Temperature Accuracy
Max. T Error (°C) Typ. T Error (°C)

1.2
Temperature Measurement Error (°C)

0.8

0.6

0.4

0.2

0
-40 -35 -30 -25 -20 -15 -10 -5 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100105110115120125
Temperature (°C)
How to Order:

[FCC/IC]
3: 868 MHz [CE]

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

31 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Current

Features:
• Fast installation over a variety of power lead
diameters.
• Easy installation with 1/2” conduit threaded
nipple mount.
• Standard CT opening width is 1.25” for 50A
through 600A service.
• CT with 0.75” opening width is available for
50A through 200A service by request.
• Configurable measurement and broadcast
intervals*. Refer to the Voice of the Machine
Cloud for more information about capabilities
and modalities.

Sensor Technical Data


Base Material Aluminum
Housing Material Polycarbonate
Port 1/2-14 NPSM Thread
Measurement Range (Amperes) 50-600
Accuracy 5% (Full Span)
Resolution 0.1% (Full Span)
Ambient Temperature (battery limited)** -4°F to 158°F
[-20°C to 70°C]
Full Range Life Cycles > 1 million
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

*Consult Subscription Agreement and Order Form or Parker QCD for any changes regarding data rates.
**Ambient temperature range can be broadened by installing Wired Power Adapter (SNWP2-2)

32 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Current

Current

Part Number Measurement Range Port D H W L


SNC2-050-2 10-50 Amps 1/2-14 NPSM 2.11” [54mm] 2.67” [68mm] 1.86” [47mm] .44” [11mm]
SNC2-100-2 20-100 Amps 1/2-14 NPSM 2.11” [54mm] 2.67” [68mm] 1.86” [47mm] .44” [11mm]
SNC2-200-2 40-200 Amps 1/2-14 NPSM 2.11” [54mm] 2.67” [68mm] 1.86” [47mm] .44” [11mm]
SNC2-300-2 60-300 Amps 1/2-14 NPSM 2.11” [54mm] 2.67” [68mm] 1.86” [47mm] .44” [11mm]
SNC2-400-2 80-400 Amps 1/2-14 NPSM 2.11” [54mm] 2.67” [68mm] 1.86” [47mm] .44” [11mm]
SNC2-600-2 120-600 Amps 1/2-14 NPSM 2.11” [54mm] 2.67” [68mm] 1.86” [47mm] .44” [11mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe. For
sales information outside of these regions, please contact your Parker representative.

How to Order:

[FCC/IC]
3: 868 MHz [CE]

10-50
20-100
40-200
60-300
80-400
120-600

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

33 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Flexible Displacement

Features:
• Magnetic base for tool free mounting.
• Threaded stud port provides alternative
mounting option where magnetic base is
not suitable.
• Soft, thin and conformable sensors.
• Reliable accurate measurements while being
strained up to 100% for millions of cycles.
• Resilient silicone rubber that can withstand
harsh environments.

Sensor Technical Data


Active Area Dimensions 50mm x 14mm 100mm x 14mm
Maximum Extension 100mm 200mm
Resolution ±0.1% strain FS (±50μm) ±0.1% strain FS (±100μm)
Sensitivity 0.026% strain FS (13μm) 0.026% strain FS (26μm)
Linearity ±1% FS ±1% FS
Hysteresis ±1% FS ±1% FS
Stiffness 0.15 N/mm 0.15 N/mm
Percent strain in 100ths of a percent of length of Percent strain in 100ths of a percent of length of
Measurement Outputs
active area; temperature in °C or °F active area; temperature in °C or °F
Sampling Rate 1Hz for standard configuration 1Hz for standard configuration
Ambient Temperatures -40°F to +185°F, [-40°C to +85°C] -40°F to +185°F, [-40°C to +85°C]
Full Range Life Cycles > 5 million > 5 million
IP Rating IP67 IP67

Transmitter Technical Data


Base Material Aluminum
Housing Material Polycarbonate
Temperature Range with Wired Power -40�F-185�F
Temperature Range with Battery -4�F-158�F
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

34 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Flexible Displacement

Sensor Kit Sensors

Part Number Sensor Length (L) Sensor Width (W) Cable Length
EAPS-50HD 1.97” [50mm] 0.67” [17mm] 18” [457.2mm]
EAPS-100HD 3.94” [100mm] 0.67” [17mm] 18” [457.2mm]
Part Number Transmitter Sensors
SNES2-KIT-2-50 (1) SNES2-2 (2) 50mm

Transmitter

Part Number Base Mounting Thread D H L


SNES2-2 1/4-28 UNF x 0.45” [11mm] 2.11” [54mm] 2.67” [68mm] 2.41” [61mm]
Note: Products in catalog are currently only for sale in the U.S., Canada and Europe.
For sales information outside of these regions, please contact your Parker representative.

How to Order:

HD

Sensor Type
HD: Heavy Duty

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

35 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Vibration Sensor

Features:
• Configurable acceleration amplitude
• +/- 2g, 4g, 8g or 16g
• 6.4 Khz sampling frequency
• 3 axis measurement
• RMS & Peak acceleration or velocity
• Temperature

Sensor Technical Data


Housing Material Polycarbonate
Base Material Aluminum
Mounting Options Magnet, 1/4-28 stud, Epoxy
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

Acceleration Technical Data


Acceleration Range +/-2,+/-4, +/-8, +/-16 g absolute [configurable]
Frequency Range 1 Hz to 3200hz
Sampling Frequency 6.4 KHz
Measurement Output Peak & RMS acceleration over frequency range;
Temperature
Measurement Axes X,Y, Z
Resolution (Peak) +/- 2 g range = 1 mg, +/-4 g range = 2mg,
+/-8 g range = 4mg, +/-16 g range = 8mg
Temperature Sensor -40 to +85 C
Samples Per Acquisition 800 samples
Filter Specs DC offset removal

Velocity Technical Data


Velocity Range 0 - 327 mm/sec
Frequency Range 7.5 Hz to 3200 Hz
Sampling Frequency 6.4 KHz
Measurement Output Peak & RMS velocity over frequency range;
Temperature
Measurement Axes X, Y, Z
Resolution 0.01 mm/sec
Temperature Sensor -40 to +85 C
Samples Per Acquisition 2200 samples
Filter Specs 7th order butterworth digital high pass filter,
60 dB down at 3 Hz, 3 db down at 7.5 Hz.

36 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Vibration Sensor

Transmitter

Part Number Base Mounting Thread D H


SNVT2-1632-2 1/4-28 UNF 1.88” [48mm] 2.05” [52mm]

Measurement Axes

How to Order:

V 16 32

[FCC/IC]
V: Vibration 3: 868 MHz [CE]
T: Temperature Effective Measurement Frequency Range
32: 3200kHz

Max Configurable Amplitude


16: ±16g Amplitude

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

37 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Analog Connector

Features:
• Connects inline with any 4-20mA Sensor
• Integrates hard wired sensors into wireless
Voice of the Machine Software
• Does not require reprogramming of existing
control system
• Definable mapping feature in Cloud to present
4-20mA signal in user defined units
• Magnetic base for tool free mounting
• Threaded stud port provides alternative
mounting options where magnetic base is not
suitable
Transmitter Technical Data
• Requires connection cable SCK-400-xx-xx in
Base Material Aluminum
conjunction with transmitter and 4-20mA
Housing Material Polycarbonate
Sensor
Accuracy 0.5% (additive to source)

Resolution 0.1%

Temperature Range with Wired Power -40�F-185�F
Temperature Range with Battery -4�F-158�F
Full Range Life Cycles > 1 million
Certifications FCC, IC, CE
Battery (Panasonic is recommended brand) CR123A
IP Rating IP65

38 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Analog Connector

4-20mA Transmitter (Battery Powered)

Part Number Base Mounting Thread D H L


SN322-2 1/4-28 UNF x0.45” [11mm] 2.11” [54mm] 2.67” [68mm] 2.41” [61mm]

Note: Products in catalog are currently only for sale in the U.S., Canada and Europe.
For sales information outside of these regions, please contact your Parker representative.

Pin Assignment
Transmitter Cable
PIN Connection Wire Color
1 No Connection Brown
2 4-20mA Signal In White
3 4-20mA Signal Out Blue
4 No Connection Black
5 No Connection Gray

M12 Connection Cable


Part Number Cable Length Plug-in Connector
SCK-400-02-45 6.5 ft [2m] M12 socket, straight
SCK-400-02-55 6.5 ft [2m] M12 socket, 90�
SCK-400-05-45 16 ft [5m] M12 socket, straight
SCK-400-05-55 16 ft [5m] M12 socket, 90�
SCK-400-10-45 32.5 ft [10m] M12 socket, straight
SCK-400-10-55 32.5 ft [10m] M12 socket, 90�

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

39 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Gateway System

Part Number Communication Connectors Compliance


SN-CS-5 LTE (AT&T), Ethernet, WiFi RS232, RS485, GPIO, CAN, USB, LAN FCC, IC, PTCRB

SN-CS-6 LTE (VZW), Ethernet, WiFi RS232, RS485, GPIO, CAN, USB, LAN FCC, IC, PTCRB

Specifications Description
System
Processor Intel® ATOMTM, E3815/1.46GHz, Single-core processor
On Board RAM DDR3L 2GB
SSD Internal Half-Slim SATA SSD Module Internal (16GB)
Display
Resolution 2560x1600 @ 60Hz for VGA
Interface 1xVGA (DB15)
Wireless Communication
WLAN 802.11 b/g/n Wireless Module, external antenna
Bluetooth Bluetooth 4.0 module, with external antenna
Cellular Data Module 4G/LTE CAT1 Cellular Module with SIM slot and two external antennas
RF Module Parker SensoNODE Low Power Wireless Module with external antenna
I/O
Ethernet 2x10/100/1000-BaseT(RJ45)
USB 2xUSB2.0 Host (Type A)
Audio HD Audio, 1xMIC in 3.5mm, 1xline Out 3.5mm
COM Port 1xRS232/422/485 (Full Function, DB9); 1xRS232/485 (2 wires on Green Terminal)
CAN 1xCAN 2.0b
Alarm Buzzer Out
SD card 1xSD card Slot
RTC Supported
Control Reset Button on the top
GPIO Reserved GPIO (terminal)
UART 1x full function UART use DB9
Accelerometer On Board Accelerometer, 3-Axis

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

40 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Gateway System

Specifications Description
Security
Security TPM module
Software
OS Secured Embedded Linux
Applications Parker Voice of the Machine Edge software
Power

Input DC12 / 24V(9-36V), Locked Power Jack


Consumption 6W (Pulse8W), Sleep 2W. (without LTE,GPS,WLAN)
Mechanical
Dimensions 176x101x52mm (Box)
Install Brackets 198x101x52mm
Weight 0.6Kg (1.2Kg package Kit)
Enclosure Aluminum Alloy with Black Color
Environment Condition
Temperature Operating: -20°C ~ +60°C, Storage:-40°C ~ +85°C
Humidity 5-95%RH at 25-35 (Non-Condensation)
Cooling Mode Fan less, Heat Sink
Approvals UL, FCC Class B, CE, RoHS, and PTCRB Compliance

Repeater

• Primary use as a network repeater (range extender)


for all sensors connected to mCard PRN
• Connects to gateway or power source via 2 meter USB cable
• Support for up to 500 sensors at one hop each
• Robust overmolded design for harsh environments

Part Number W D H L
SNPRN-2 2.75” [70mm] 1.81” [46mm] .53” [13mm] 3.12” [79mm]

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

41 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Gold Wired Power Supply

Features:
• Supplies continuous power to sensors.
• Used with IEC/UL 508 Class 2 power supply.
• Easy upgrade eliminates the need for
battery replacement.
• Extends temperature range over batteries.
• FCC, IC, and CE certified when used with
SensoNODE products.

Technical Data
Part Number SNWP2-2
Wire Length 9.8 ft [3m]
Temperature Range -40�F-185�F
Input Power 5-36 Volts DC
Output Power 3 Volts DC
Connection Flying lead 24 AWG Wires
Form CR123A Battery

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

42 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Voice of the MachineTM Cloud Software Software

Voice of the Machine Cloud Software


The Cloud interface is used for continuous remote Capabilities:
monitoring for long-term condition monitoring • Monitor multiple assets in multiple facilities
applications. The web-based interface allows users anywhere, anytime
to remotely retrieve data. • Connect with and display SensoNODE Gold
Sensors
SensoNODE Gold Sensors integrated into assets or
production lines collect the data and send it to the Features:
on-site collection server, which pushes the data to • Easy to use web-based interface
the cloud. Users access that data by logging into the • No software to download or update
software via their desktop anywhere they have an • Receive alert notifications via email, text, or
internet connection. The interface lets users monitor in-system
and collect data from multiple assets and receive • Visualize data in a way that makes most sense
alerts of deviations. • Customize alerts, trend charts, and dashboards
• View measurement anomalies easily
With increased awareness of processes and assets, • Support continuous improvement efforts with
users don’t have to be on-site to review data to trend data
optimize machine performance, extend service life, • Multiple user access levels
maintain production quality and reduce downtime. • Remotely monitor multiple sites and sensors
• Easily export data

43 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Voice of the MachineTM Edge Software Software

Edge Software
The industry’s most secure Edge-level solution.
Seamlessly connect to nearly all industrial
devices and systems, liberating, processing, and
integrating the data from the factory floor into
Cloud or on-premise, enterprise systems.

Key Benefits & Overview:


The Edge interface is designed to work seamlessly
with a web browser based user interface. Data is
ingested from virtually any industrial asset. The Features:
software allows you to run various applications Edge provides several key functionalities that
utilizing your data at the Edge, or send it securely are necessary for any IoT deployment. Using a
to the Cloud for seamless enterprise integration. management UI, Edge enables the distribution
of drivers at the gateway level to collect data
• App & Industrial Driver Marketplace from almost all legacy industrial protocols. Run
 Get started with free drivers such as applications locally (at the Edge) for quick and
Ethernet/IP, Modbus RTU, TCP, RS232, effective processing, so you don’t bombard your Cloud
RS485, and more. infrastructure with unnecessary data.
• Security Monitoring
Instantly find anomalies in access,
Industrial Device Connectivity
external hacking, and non-permitted
Using a simple drag and drop
data transmission.
interface, collect data from
• Remote Device Management
many different types of legacy
Gateways are capable of being provisioned
or modern systems with Flows.
to software or other system.
Many downloadable drivers are
• 3rd Party Cloud Integration
available for free.
Send your processed and filtered data
to the cloud interface or other 3rd party Cloud
Application Deployment
connectors to enable end-to-end solution
Includes an application
creation.
marketplace where you can
• Private Marketplace
effortlessly deploy and run
Edge provides OEMs and System Integrators
applications at the Edge.
with the ability to host a private marketplace of
Applications include: data
applications and drivers for their customers.
filtering, analytics, CEP, data
• Easy to Use Graphical Programming Interface
enrichment, rules and alerts
An extensive UI and flow-based
engine, and more.
configurations make solution building
simple and easy.
Secure Access
Login/password protected access
to gateway with the ability to setup
multiple levels of permissions.

44 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Sensors - Blue and Gold Accessories

SCC-255 SCC-260

SensoNODE Accessory Case


Part Number L W D Case
SCC-255* 14” 11.5” 5” Blow Molded Case
SCC-260* 16.5” 13” 7” Ruggedized Case with Room for Tablet
*Sensor products not included.

Battery (CR123A)
Part Number Technology Voltage
QX-008-121 Lithium Ion 3.00V

EMA3 Series – Test Port Couplings


Male Pipe Thread
Part Number Port Thread Size Wrench Flats Interface Thread Size Overall Length Weight
EMA3/1/8NPT 1/8-27NPT 17 M16X2.0 1.81” [46mm] 0.15lb [.07kg]
EMA3/1/4NPT 1/4-18NPT 17 M16X2.0 1.98” [50.3mm] 0.16lb [.07kg]

SAE Straight Thread


Part Number Port Thread Size Wrench Flats Interface Thread Size Overall Length Weight
EMA3/7/16-20UNF-2A* 7/16-20UNF 17 M16X2.0 1.88” [47.8mm] 0.15lb [.07kg]
EMA3/9/16-18UNF-2A* 9/16-18UNF 19 M16X2.0 1.88” [47.8mm] 0.17lb [.08kg]
*O-Ring seal on port

EMA Gauge Adapter


Part Number Port Thread Size Wrench Flats Interface Thread Size Overall Length Weight
MAVMD1/4NPT-MA3 1/4-18NPT 19mm M16X2.0 2.22” [56.4mm] 0.18lb [.08kg]
SCA-7/16-EMA-3 7/6-20 19mm M16X2.0 1.60” [40.64mm] 0.15lb [.45kg]
Note: Consult QCD or Catalog #3800 for additional accessories and port options.

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

45 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
SensoNODETM Sensors - Blue and Gold Accessories
PD Couplings

Couplers- Female Thread

Body
Part Number Thread Size Overall Length Wrench Flats Largest Diameter Weight
Size
1/8 PD240 7/16-20 UNF 2.12” 0.8” 0.96” 0.26lb
1/8 PD242 1/4-18 NPTF 2.12” 0.8” 0.96” 0.25lb

Nipples- Female Pipe Thread

Body Exposed Wrench Largest


Part Number Thread Size Overall Length Weight
Size Length Flats Diameter
1/8 PD322 1/8-27 NPTF 1.48” 0.78” 0.56” 0.65” 0.06lb
1/8 PD342 1/4-18 NPTF 1.63” 0.93” 0.75” 0.87” 0.12lb

Nipples- Male Pipe Thread

Body Exposed Wrench Largest


Part Number Thread Size Overall Length Weight
Size Length Flats Diameter
1/8 PD323 1/8-27 NPTF 1.55” 0.85” 0.69” 0.79” 0.17lb
1/8 PD343 1/4-18 NPTF 1.48” 0.78” 0.69” 0.79” 0.06lb
1/8 PD363 3/8-18 NPTF 1.50” 1.13” 0.81” 0.96” 0.09lb

Nipples- Male Straight Thread

Body Exposed Wrench Largest


Part Number Thread Size ORB Overall Length Weight
Size Length Flats Diameter
1/8 PD341 7/16-20 UNF 1.60” 0.90” 0.69” 0.79” 0.08lb
1/8 PD361 9/16-18 UNF 1.32” 0.62” 0.69” 0.79” 0.06lb

Note: Consult QCD or Catalog #3800 for additional accessories and port options.

The products listed can expose you to chemicals including Lead, which is known to the State of California to cause cancer, and to cause birth defects or other reproductive harm.
For more information go to www.P65Warnings.ca.gov

46 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Notes

47 Parker Hannifin Corporation


Quick Coupling Division
Minneapolis, MN
parker.com/conditionmonitoring
Parker Fluid Connectors Group

Your complete source for quality For more information on


tube fittings, hose & hose fittings, SensoNODE and Voice of the Machine
brass & composite fittings, quick- products:
disconnect couplings, valves, and
Visit: Parker.com/ConditionMonitoring
assembly tools, locally available from
a worldwide network of authorized Call: (763) 544-7781
distributors.
For more information on
Fittings:
Available in inch and metric sizes SensoControl Wired Diagnostic and
covering SAE, BSP, DIN, GAZ, JIS, Control products:
and ISO thread configurations,
Visit: Parker.com/SensoControl
manufactured from steel, stainless
steel, brass, aluminum, nylon, and Call: (763) 544-7781
thermoplastic.
Have questions or need help? Sign into
Hose, Tubing, and Bundles: our Condition Monitoring Service Desk.
Available in a wide variety of sizes
and materials including rubber, wire- Solutions.Parker.com/IoT-Support
reinforced, thermoplastic, hybrid and
custom compounds.

Worldwide Availability:
Parker operates Fluid Connectors
manufacturing locations and sales Sales of SensoNODE Sensors and Voice of the Machine Software in
offices throughout North America, U.S., Canada and Europe. Consult QCD for other regions.
South America, Europe, and Asia-
Pacific.

© 2019 Parker Hannifin Corporation Catalog 3864/USA 3/19

Parker Hannifin Corporation


Quick Coupling Division
8145 Lewis Road
Minneapolis, MN 55427
phone 763 544 7781
fax 763 544 3418
parker.com/conditionmonitoring

You might also like