Dental Studio Plus: User Manual
Dental Studio Plus: User Manual
Pag. 1
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 2
The state of the art for the modern dentists
Sommario
1. INTRODUCTION ........................................................................................................................... 5
INTRODUCTION ......................................................................................................................... 6
DESTINATION OF USE AND USER PROFILE.................................................................... 7
USER PROFILE ............................................................................................................................ 7
TRAINING ..................................................................................................................................... 7
UPDATE ......................................................................................................................................... 8
WARRANTY ................................................................................................................................... 8
COMPUTER REQUIREMENTS ................................................................................................. 8
HOW TO USE THIS MANUAL ............................................................................................... 13
2. INSTALLATION AND PACKAGING ........................................................................................ 14
PACKAGING ............................................................................................................................... 15
INSTALLATION.......................................................................................................................... 15
3. SOFTWARE INITIALIZATION .................................................................................................. 17
SOFTWARE INITIALIZATION ............................................................................................... 18
PASSWORD ADMINISTRATION .............................................................................................. 19
4. PROGRAM ACCESS .................................................................................................................... 21
PROGRAM ACCESS: Password and user administration .......................................... 22
PROGRAM ACCESS: Reset database selection. ........................................................... 22
PROGRAM ACCESS: Reset password. ........................................................................................ 22
PROGRAM ACCESS: Access to the software ................................................................. 23
PROGRAM ACCESS: New User ........................................................................................... 23
PROGRAM ACCESS: Delete User .................................................................................... 24
PROGRAM ACCESS: Display user access ................................................................... 25
PROGRAM ACCESS: Forgotten Password ................................................................... 26
PROGRAM ACCESS: Change Password ........................................................................... 26
5. DATABASE CONFIGURATION ................................................................................................ 27
DATABASE CONFIGURATION: Drive administration.................................................. 28
DATABASE CONFIGURATION: Add a drive to the used database ........................ 28
DATABASE CONFIGURATION: Disconnect a database ......................................... 29
DATABASE CONFIGURATION: Database Drive configuration .......................... 30
PATIENTS: Patient database ............................................................................................... 31
6. PATIENTS DATABASE .............................................................................................................. 32
PATIENTS: Create a new patient .................................................................................................. 33
PATIENTS: Compile all the patient’s data.................................................................................... 35
PATIENTS: Patient search ............................................................................................................ 36
PATIENTS: Create a new patient category ................................................................................... 38
PATIENTS: Modify patient ........................................................................................................... 39
PATIENTS: Choice of a patient .................................................................................................... 39
7. IMAGE MANAGEMENT ............................................................................................................. 42
IMAGES: IMAGES MANAGEMENT ......................................................................................... 43
IMAGES: Image toolbar function ...................................................................................... 44
IMAGE OPTIONS: Setting Image options ...................................................................... 46
Images: Dicom Viewer .......................................................................................................... 48
IMAGES: Import images ............................................................................................................... 50
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 3
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 4
The state of the art for the modern dentists
It points out one "NOTE"; particular attention recommend in the reading of the topics identified with
such icon.
It points out one "ADVICE"; the topics identified with this icon concern the safety aspects of the
patient and/or of the operator.
0051 This symbol certifies that the product "Dental Studio Plus" is conforming to the
European directive 93/42 CEE, as modified from 2007/47/CE.
Dental Studio Plus is a medical active device, not invasive type, in IIA class according to
the above mentioned directive.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 5
The state of the art for the modern dentists
1. INTRODUCTION
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 6
The state of the art for the modern dentists
NOTE:
The manual is updated to the state of the product with which it is sold for guaranteeing to the
consumer a suitable reference in the use of the instrument and every aspect to the safety of use.
The manual would be not reflected variations of product deprived of impact on the operational
formalities and on the safety of use
INTRODUCTION
First of all we would to congratulated for your purchase. This software is the most complete,
tastefully and at the same time simple to use, that is available on the market, for the
management of the Dental cabinet and for the filing of digital imagines.
NOTE:
Dental Studio Plus® is supplied in different versions that foresee the functionality of procedures
defined "advanced". Some functionalities listed in the manual are present only in the supplied modules
as additional option. Inside this manual it is indicated if the described function is not included in the
basic version.
This software will permits you to manage all the data of the Dental cabinet in a very simple
and intuitive way. Moreover, Dental Studio Plus® integrates calls to the acquisition software
of a lot of electronic devices: video radio X-Ray system, telecameras, digitals panoramic,
scanners, cameras, slides scanner, etc.
All the acquired images, independently from their origin, are automatically saved as acquired
by the software of the different devices. You can create a sequential archive for your images,
or you can group them to obtain systematics and photographic album.
With maths filters you can improve the contrast or the brightness for a better analysis; you
can also use the filters to exalt the edges or to transform in 3D your image and also to
rotate the 3D image in real time. The original image is always present and can be
displayed in every moment.
Moreover, with the virtual colorations, the few contrasted X-Ray examination it results very
simple.
An intelligent system will you clarify in every moment, in a very detailed way, the cause of a
malfunctioning or an error.
Remember that this software is fruit of the users collaboration. Please, do not hesitate to give
us your councils on the use and functioning of the software, and your desire of new
functionality also. We should be glad to add it, if necessary, in the future versions of the
program.
This software has been developed with 32 bits technology. For many users this is a negligible
information, but it indicates: further reliability, exclusive use on 32/64 bits Operative System
(Windows® NT/2000/XP/Vista/7), much more web reliability.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 7
The state of the art for the modern dentists
NOTE:
Dental Studio Plus® can also be used on operating systems to 64 bits like Windows Vista and Windows
7. Such peculiarity is specific of the product Dental Studio Plus and not of the devices connected to the
computer. Before purchasing a computer with an operating system to 64 bits verified that the
equipments to be connected to the personal computer (scanner, cameras, videoradiografy system,
digital panoramic, etc) foresees this possibility.
ADVICE:
The good quality of the monitor is an essential requirement for a correct diagnosis of the examination
through analysis of the image. A monitor that don't passed the scheduled verifications (see appendix
2, "Verification of the adequacy of the monitor") is not to consider diagnostic. The use of a monitor of
not diagnostic quality returns not diagnostic Dental Studio Plus® system
ADVICE:
The intraoral version (light version) of Dental Studio Plus is a limited version of the full one. Some
functionalities described in this manual may be not active for the light version
Dental Studio Plus® is an active medical device destined to be employed on the man to help to the
diagnosis, prevention, control of pathologies of the maxillo-facial complex.
1. The system is destined therefore to the acquisition, visualization and filing of radiographies of the
maxillo-facial complex, including both the examinations of the dental arcades, included the articulations
temporo-mandibular, the air sinuses, radiographies of the head in side to side projection and
antero/posterior, radiographies coming from systems CT and or ConeBeamComputed Tomography (CBCT).
2. The tool is destined to be used from personal qualified, dentists, radiologists or personal legally
qualified.
The typology of population of the patients depends in first place on the used equipment of radiology,
without limitation type, age, etc.
USER PROFILE
It is required to the operator to have familiarity in the use of Personal Computer (PC) and
relative software, so that to be able to use the present functions on the PC in easy way.
TRAINING
At the end of the installation of the system it will follow the training of the operator both on the
use of the system and of the acquisition and visualization software of the images.
The training doesn't ask to use particular tools.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 8
The state of the art for the modern dentists
ADVICE:
At the end of the operations of installation and training it is obligatory to perform the verification of
correct visualization of the images on the monitor in use.
The procedure is described in the appendix 2 - Controls to the installation and periodocal, which it is
postponed.
ADVICE:
The procedures of verification described in the appendix 2 must be perform with regularity, as
described in the paragraph related to the periodic controls.
This manual describes the necessary operations to perform intraoral radiographies, panoramics
and volumetrics (or 3D) with various types of digital sensors.
ADVICE:
The application of filters to the images, the calibration of the measures, the change of contrast and
brightness and all the functions that modify the images, can introduce artificials that compromise the
diagnosis. For this reason Dental Studio Plus® always preserves the original copy of the image to
which is had to make reference for the diagnosis
UPDATE
Dental Studio Plus® is a medical device. Before a software update of the product we invite you
to observe the specified following warning.
ADVICE:
Dental Studio Plus® is a software and therefore it can be updated with special procedures without the
presence of a specialized technician. Dental Studio Plus® is a medical device and the producer and/or
supplier have the duty to hold trace of all the installed versions with the purpose to be able to apply
possible call back following found defectiveness. For this reason we invite you not to update the
version of the software that has been delivered you if not following of a documented procedure from
your supplier of reference that guarantees the traceability of the product.
WARRANTY
This software is guarantee during 90 (ninety) days after the purchase date. Producer could
not be responsible for any direct or indirect damage deriving from the program use; partial or
total loss of data neither.
The program is assigned in use licence and could be give to thirds parties only upon written
authorization of Villa Sistemi Medicali S.p.a.
COMPUTER REQUIREMENTS
Minimal requirements of your computer are:
Windows® XP/2000
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 9
The state of the art for the modern dentists
1 GB RAM (2 GB suggested)
1024x768 pixels to 65.000 colours (1280x1024 pixels to 16 millions colours to 32 bits
optimized)
5GB HD (10GB suggested)
17” monitor (19” best or higher)
The Hard Disk size must be proportional with the archive size you create, and in particularly
with the images size that you save.
Every X-Ray image need, on the HD, a space that varies between 100KB (compressed) and
500KB (not compressed). A panoramic needs from 1MB (compressed) to 10MB (not
compressed). A telecamera pic occupies from 100KB (compressed) to 1MB (not compressed).
Your hard disk dimension have to be sufficient to contain the images you want to save. A TC or
CBCT exams need from 10 MB to 200 MB (it depends from the resolutions).
The necessary RAM (Random Access Memory) for Dental Studio Plus® is almost of 512 MB.
Windows® can manages the virtual memory, that is a RAM extension on the HD. This in case
the RAM in not sufficient, Windows® uses the Hard Disk like a RAM. This operation involves a
slowing down of the system, that because the hard disk is slowness than RAM.
Before to run Dental Studio Plus®, please verify the memory available. In Windows Vista®
proceed in the follow way
Click on Start icon than click, with right mouse button, on “Computer” than select the
menu item “Property”
Pic. 1.1
Check the Memory (RAM) available. The minimum value under Windows Vista is 1 GB (2 GB if
you use the 3D modules).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 10
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 11
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 12
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 13
The state of the art for the modern dentists
This manual is organized in cards. Every function is presented in his use and if possible with
utilize examples. Exist a paragraph “Description”, one “Operation” and one “Additional
Informations”.
Since this software uses electronics devices (computer, mouse, peripherals), are often used
terminologies or specific acronyms. We apologize if the reading can result little clear, but we
will here try to explain some terms used in the text.
The phrase “move the mouse…” means that you have to displace the monitor indicator
(normally an arrow) that indicates the mouse position, in a specific zone.
“Click with the mouse” means to bring the mouse in position, then press the right button
and release it.
The “buttons” represent the program function that you can activate clicking with the mouse
on the same.
You can also find “To recover the image…”; you have to open the archive window
(sequential or systematic), then select the image you want to elaborate and send it, using the
right buttons, to the elaborations window.
For using this software, we suggest a basilar knowledge of Windows®95 or later. If any
basilar concepts are not clear (what’s a window, how to recall a program, ecc) we advise you
to read a little Windows® manual, or make the Windows® exercises.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 14
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 15
The state of the art for the modern dentists
PACKAGING
When you receive the box with the application, you will receive a usb dongle. This dongle is
the software protection. You should connect this key after the full installation to ensure the full
application working. You can connect this key to any computer of the network. This key allows
you to use the application on 10 computer simultaneously.
INSTALLATION
When you insert the installation CD in the CD Rom reader the following window will be
displayed.
Pic. 2.1
1. Program installation
This option will install all the application. You can use this option to update an existing
installation also.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 16
The state of the art for the modern dentists
3. System driver.
Install the drivers for the system that you have, according to picture 2.2:
Videograph or Videograph HD Intraoral Drivers Installation in order to install the driver
intraoral unit sensor;
Scanograph Drivers Installation in order to install the driver for Scanograph intraoral
PSP plates scanner
Strato D, Rotograph D Drivers Installation in order to install the driver for 2D system;
Rotograph EVO Drivers Installation in order to install the driver for 2D system;
EVO 3D Drivers Installation in order to install the driver for 3D system with sensors of
first generation;
EVO 3D DX Drivers Installation in order to install the driver for 3D system with sensors
of second generation.
EVO 3D TS in order to install the driver for 3D system with partial volumes option.
for Rotograph Prime please use QuickVision CD to install the equipment drivers.
When you select one of this options a wizard user interface appears, and a sequence of dialog
boxes lead the user through a series of well-defined steps for getting a successful installation.
Make sure that you don’t install the wrong drivers.
If you are going to intall Videograph Intraoral Drivers make sure that the sensor is connected
via USB to the PC.
When you finish to install all the procedure, in same cases you need to restart the computer.
Pic. 2.2
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 17
The state of the art for the modern dentists
3. SOFTWARE INITIALIZATION
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 18
The state of the art for the modern dentists
SOFTWARE INITIALIZATION
Pic. 3.1
Before start working with Dental Studio Plus® you need to understand how the
software has been projected and then realized.
The basilar objective for the realization of this program, is the SEMPLICITY OF USE. To
obtain this purpose, we’ve started from the idea that a software is simpler to use if there are
few overlapping windows it contains. It is necessary to arrange in the monitor the maximum of
possible information, subdivided for argumentation.
Often, many software force to complex and long procedures, too difficult to remember. This
means that to complete a not frequently operation, it must make a big effort for find the
correct way. Our objective is: little clicks with the mouse to follow every procedure.
Dental Studio Plus® has been developed for a very intuitive use.
The main window of Dental Studio Plus® is like the picture here over. The photo can be easily
personalized.
The “Close session” button must be utilized every times you go away from the computer;
using this button you can standby the program; for being able to re-use it, it will be necessary
to insert again the password, in this way, during your absence, if nobody knows the password,
no one will be able to use it. This procedure guarantees the use of the software, in conformity
with the new dispositions in matter of privacy protection.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 19
The state of the art for the modern dentists
The program is divided in two big categories: Patients and Utilities. Clicking on one
of this button you will approach to three different windows:
identifying patients, managerial, usefulness of the program.
This three windows contain the button with which you can easily back to the main menu of the
program.
Pic. 3.2
PASSWORD ADMINISTRATION
PROGRAM ACCESS: First access to the program
Pic. 3.3
Click on OK and the program will automatically use the software starting drive as default
database.
Pic. 3.4
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 20
The state of the art for the modern dentists
Then, if you don’t have installed the demo database, this window will open
Pic. 3.5
Click on Yes and Dental Studio Plus® will automatically create the environment for begin
NOTE:
We recommend you to perform the functional verification of the monitor to verify that the the monitor is
proper for the visualization of the radiographic images. This procedures automatically started the first
time that is accessed the images module.
The procedure to perform this verification is available in the section "Utility" of the module "management
imagines", as from following image, pressing on the icon "Verification functionality of the monitor".
The procedure to perform this test is described in the chapter….. which is postponed.
If you don’t have registered the application yet, the follow window will be displayed.
Pic. 3.6
You can enter now your cabinet data. If you don’t want to write the data now, click on Close.
This window will be displayed everytime you open the application, until you insert the data.
Please remember that you cannot change the registration data after you store them in the
hardware protection key, so do not register any information before it is agreed with the
customer.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 21
The state of the art for the modern dentists
4. PROGRAM ACCESS
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 22
The state of the art for the modern dentists
First access at the program At the software start, you’ll see this window
Pic. 4.1
This button resets the configuration of active drives. Only the C drive will be preserved.
This procedure allows to reset the password bringing it to the initial value "12345678". The
password can be reset only by the administrator of the computer. Before proceeding to the
resetting of the password, Dental Studio Plus® asks the name of the administrator of the
computer and the password (credential of Windows). Only the correct insertion of these data
allows to perform the resetting of the password. This procedure guarantees the use of the data
if the administrator loses the password.
NOTE:
Dental Studio Plus® allows the zero resetting of the password only from the administrator of the
computer. The safety of the data of the administrator and the position of the access to the database is
assigned to the administrator of the net or the single computer
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 23
The state of the art for the modern dentists
If you are running for the first time Dental Studio Plus®, the password is 12345678. Right
after the program will you ask for change it, using this window
Pic. 4.2
Insert the old password one time, then the new for two times.
Click on OK then insert the new password in the previous window. (Pic. 4.2).
Click on Access to enter in the program. In conformity with the regulations in force, all the
accesses are memorized from the software.
To add a new user or to eliminate an existing one, after the Administrator password insertion,
click on Maintenance (Pic. 8)
Pic. 4.3
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 24
The state of the art for the modern dentists
Pic. 4.4
Insert the name, the password and select the access type. You can also insert a question and
an answer you only know, for recover your password in case you have forgot it.
Pic. 4.5
The Administrator is free to make all the operations in the software. The Standard User can
do managerial operations but he can’t visualize the amount of the same. The External
Consultant is an external collaborator who helps the Cabinet in the management accounting.
The Secretary is the cabinet secretary and the Limited Account is the one that can see only
some patients that the administrator has decided to show.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 25
The state of the art for the modern dentists
Pic. 4.6
You could have the possibility to select the user to remove. Click on OK then the user will be
deleted.
Pic. 4.7
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 26
The state of the art for the modern dentists
In this way you can see all the access occurred: date and hour, user name and computer
name.
Pic. 4.8
Simply answering to the question you have inserted at the registration time, the program will
indicate your current password.
Pic. 4.9
Insert your old password, then two times the new one. Click on OK and go to insert the
new password in the window of Pic. 4.9.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 27
The state of the art for the modern dentists
5. DATABASE CONFIGURATION
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 28
The state of the art for the modern dentists
One of the news of this software is the possibility of multi-task work. This option makes
Dental Studio Plus® the most exclusive software.
It means that you can subdivide the archives on more drive with the possibility to see all
of them contemporary.
Example:
If you want to let on the net drive (drive S) only the patients under treatment at the moment,
you can save them on drive S. All the others patients, for example the historic ones, can be
saved on drive T (general drive). Dental Studio Plus® can use all the archive (until 20 drives)
contemporary
Pic. 5.1
Click on Display or select the database to use or on the double arrow in the lower part of
main menu (Pic. 5.1)
Pic. 5.2
Click on Add drive and the software will show you the available drives.
Pic. 5.3
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 29
The state of the art for the modern dentists
NOTE:
Dental Studio Plus® verifies if the added disk contains the database. If the disk doesn't contain the
database it will asked you to create the environment of job. In affirmative case a driven procedure will
help you to create the database. In negative case, the disk won't be added.
Pic. 5.4
Right click on the drive you want to disconnect then click on Disconnect database.
Drag with left click the drive to eliminate into the bin on the lower right part.
A not more available drive, will be automatically removed. This to prevent the bad functioning
of the program.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 30
The state of the art for the modern dentists
Pic. 5.5
Assign a colour to this drive: assign the colour you want to the drive
Default drive for database: clicking on this option, a floppy disk icon will appear near the
selected drive. The default drive is used for: price list of treatments, tabs and prints, cabinet
data, access password and all the general data.
Default drive for notebook: clicking on this option, a notebook icon will appear near the
selected drive. In this way your notebook will be saved in this drive.
Hide the patients of this drive from the main list: in the general patients list will not be
visualized the patients of the selected drive.
Upgrade the database: clicking here the application will show this window
Pic. 5.6
At the next run of Dental Studio Plus® will be request the upgrade of the database
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 31
The state of the art for the modern dentists
Pic. 5.7
Pic. 5.8
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 32
The state of the art for the modern dentists
6. PATIENTS DATABASE
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 33
The state of the art for the modern dentists
Pic. 6.0
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 34
The state of the art for the modern dentists
Pic. 6.1
These informations are highlighted with a darkest colour: name, last name, birth date. It
is possible to complete these data in another moment too.
Before save a new patient you have to select the destination database (only if you have more
than one active database). Click on the destination database and an arrow near the database
icon will appear.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 35
The state of the art for the modern dentists
In Pic. 6.1 window, after the patient data insertion, click on Next.
Pic. 6.2
Clicking on the corresponding buttons you can acquire from: Fotocamera; Scanner,
Videocamera and Drive. Then click on Next.
Pic. 6.3 contains all the information for the patient card print.
Clicking on Print the patient’s card you can print a card for the patient, with his personal
codes. This card has a bar code for a fast activation of the patient on the dental chair
computer. We recommend to use a specific printer.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 36
The state of the art for the modern dentists
Pic. 6.3
Pic. 6.4
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 37
The state of the art for the modern dentists
To find a patient you can proceed using four ways or combining them together:
Insert Patient’s name or last name in the proper place; if you write only the first
letter of the name, or last name, the program will find all the patients whose last
name or name contains the inserted text.
Use the icon identification: clicking on Icons menu (Pic. 6.4) you can select the icon
associated to the patient you need find
Pic. 6.5
Advanced Search: you can insert the data of the patient you are searching in the
following window
Pic. 6.5.a
Use the categories: you can differentiate the patients in various categories to
simplify the acknowledgment operations. Clicking on Category menu (Pic. 6.4)
you can do the search in the wished category. The software will give you a list of
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 38
The state of the art for the modern dentists
Pic. 6.6
Pic. 6.7
Pic. 6.8
Click on OK.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 39
The state of the art for the modern dentists
To modify the personal data of a patient, click on Patient from main menu. Select the
patient you want to modify then click on Modify.
Pic. 6.9
Pic. 6.10
PATIENTS: Images
PATIENTS: Anamnesis
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 40
The state of the art for the modern dentists
Pic. 6.11
PATIENTS: REMEMBER
Trough this function you can insert a very important note to remember in anticipation of next
patient’s visit. It is possible to write everything you want. As an example to ask to the patient
if he has remembered to do the antibiotic treatment or any other important note.
Pic. 6.12
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 41
The state of the art for the modern dentists
PATIENTS: Worklist.
This function will connect the computer to a remote RIS. This option is available on if the
Dicom PACS module is enabled.
The RIS will give the patient list for the requested exams.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 42
The state of the art for the modern dentists
7. IMAGE MANAGEMENT
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 43
The state of the art for the modern dentists
NOTE:
We recommend you to perform the functional verification of the monitor to verify that the monitor is
suitable for the visualization of the X-ray images. This procedures will automatically starts the first time
that you will accessed to the images module.
The procedure to perform this verification is available in the section "Utility" of the form management
imagines, as from following image, pressing on the icon "Verification functionality of the monitor."
Pic. 7.1a
Pic. 7.1b
Pic. 7.1c
Pic. 7.1d
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 44
The state of the art for the modern dentists
The image toolbar is organized in four pages. The functions are the followings.
Start the image acquisition from the scanner using the twain interface
This option is enabled only in the version that not includes the 3D option. This
function allow the user to verify the 3D capability of the application.
Organize the images in a fixed layout where the user can save the images for a
global view, Each patient has one page and 20 images for each box.
Organize the images in a custom layout where the user can save the images for
a global view. This layout can be customizable by the user. Each patient has 10
different pages,
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 45
The state of the art for the modern dentists
IMAGES: Utilities
This option allow the user to import a TC or CBCT exam. This option is available
only when the 3D module is active.
This procedure allow the user to verify the monitor quality. We suggest to use
this procedure immediately after the installation and every 3 months.
IMAGES: Applications
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 46
The state of the art for the modern dentists
If you need to open the image configuration procedure click on as in Pict. 37a.
This page included the main option for the image modules.
This procedure selects the intraoral RVG equipment number “1” and number
“2”. The parameters for the specific RVG should be request from the hardware
developer. The application supports 2 different RVG at same times.
This procedure selects the Panoramic equipment. The parameters for the
specific Panoramic system should be request from the hardware developer.
This procedure selects the TC or CBCT equipment. The parameters for the
specific TC or CBCT system should be request from the hardware developer.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 47
The state of the art for the modern dentists
Select the intraoral RVG system to use. It is possible to select 2 RVG systems. The system are
identified as system 1 and system 2.
Select the Panoramic / Ceph system; you can select the system model from the drop-down
menu.
Select the option for the videocamera. The supported format for the scanner is the TWAIN
driver, file transfer or the direct acquisition using the VFW (Video for Windows) technologies.
Rendering engine.
Ray Cast (CPU): uses the CPU to process the 3D reconstruction. This option need a powerful
CPU and a powerful graphic board.
3d Texture (GPU): uses the GPU (Graphic Process Unit) to process the 3D reconstruction. This
option need a very powerful graphic board.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 48
The state of the art for the modern dentists
Ray Cast (Best) 3D Texture (Preview): uses the CPU to process the 3D reconstruction for the
best result when any 3D movements are finished. Uses the GPU for any 3D volume
movements.
Shading.
Set the shading value for the 3D volume. This option needs a lot of memory to work. Please
enable it only if you have at least 2 GB of RAM.
Cross Section.
Width: set the size of the cross image. The size is in millimetres.
Pano Section.
Surface reconstruction.
This function allows to show the images in DICOM format using a viewer that supports images
up to 65535 gray levels.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 49
The state of the art for the modern dentists
Pic. 7.2
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 50
The state of the art for the modern dentists
Check the option “Open all images in Dicom modality” to enable the Dicom viewer. If you want
to save a copy of the original image (by default is yes) check this option. This option allows
you to go back to the original image at any time. If you want a common toolbar check the
requested option.
Pic. 7.3
then click .
Pic. 7.4
If you want to show all file in the selected folder, check the box “Show all files”. To show the
dicom files check the box “Dicom Images”.
Click on and select the source folder from which you want to import the DICOM image.
Once selected the source and the image to save it will open the following window:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 51
The state of the art for the modern dentists
Pic. 7.5
Click on and the image will automatically be inserted in the file of the patient.
Pic. 7.6
Holding pressed the left button of the mouse on the image, it’s possible to move the image
inside the window.
Moving the small wheel of the mouse is possible to zoom the image.
Holding pressed the right button of the mouse and moving to the left or to the right the mouse
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 52
The state of the art for the modern dentists
Arrange windows: this function allows to open more images and to place side by side so that
contemporarily visualize.
Original image: this function restores the image where the filters have been applied to the
original state.
Pan Image: this function allows to move the image inside the window.
Cut image: this function allows to visualize only the part interesting of the image. Pressing
this button it will open the following window
Pic. 7.7
Positioning in one of the angles of the rectangle, and holding pressed the left button of the
mouse, it is possible to modify the size of the rectangle; holding pressed the left button of the
mouse inside the rectangle it is possible to move the rectangle in the point of the image that
interest. Press therefore the button and you will visualize the clipping selected of the
image enlarged.
Dicom TAGs: pressing this button it will appear all the information related to the image as
Dicom tags.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 53
The state of the art for the modern dentists
Toolbar: pressing this button the toolbar at the top of the window disappears and it will
appear the following window of the rapid tools
Pic. 7.8
Closing the image with this setting out, the software will remember at the next opening of the
image the same setting out.
Filters: this function allows to apply some filters at the image as shown following
Pic. 7.9
ADVICE:
The application of filters to the images can introduce artificials to compromise the diagnosis. For this
reason the diagnosis must exclusively have effected on the original image.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 54
The state of the art for the modern dentists
It is possible to create customized filter by entering in menu "Other". The following window will
be opened
Pic.7.10
Press the right button of the mouse on one of a “UNDEFINED” buttons and it will open the
following window
Pic. 7.11
ADVICE:
The personalization of the filters can give results that improve or worsen the quality of the image. Dental
Studio Plus cannot perform any control on the quality of the result. It is responsibility of the user to
create personalized filters that help to improve the quality of the image.
Insert in the "BUTTON CAPTION" field the name of the new filter. The name will be assigned to
the button previously selected.
Uses the drop down menu to customize the filters sequence (from 1 to 8).
Use the scrollbar on the lower side to modify the GAMMA CORRECTION value. Use the "Reset"
button to restore the default value.
The following examples of tables show different custom filters optimized for Panoramic images
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 55
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 56
The state of the art for the modern dentists
Every new customized filter creates a new entry in the following configuration file:
C:\Documents and Settings\All Users\AppData\ArchiMED Suite\CustomFilters\FilterList.ini
IMAGES: LUT
ADVICE:
The editing of contrast and brightness can introduce artificials that can compromise the diagnosis. For
this reason the diagnosis must exclusively have effected on the original image.
Pic. 7.12
Invert: it allows to reverse the image from positive to negative and vice versa.
W/Level ROI: this function allows to select, with the left button of the mouse, a region of the
image that interest to underline, and to modify the levels of ROI to improve the quality of the
image of the selected region.
Gamma Value: with this function it is possible to modify the value of the Gamma of the
image.
LUT: making click on this button it will open the following curtain menu that will allow to
choose the type of LUT.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 57
The state of the art for the modern dentists
Pic. 7.13
IMAGES: MEASURES
ADVICE:
The radiographies are a bidimensional representation of three-dimensional object places in the space,
therefore their representation can be deformed in function of various factors, what enlargement, relative
position of the object in comparison to the receptor of image, etc. These factors don't allow therefore a
precision quantifiable of the trial.
Dental Studio Plus® is not a tool of measure because, also after the procedure of calibration
of the measure in comparison to a known repere, the accuracy of the same measure cannot
be guaranteed, that therefore it has to be considered as indicative.
Pic. 7.14
To cancel an effected measurement is necessary to make click with the left button of the
mouse on the measurement to cancel and press the key Canc" of the keyboard.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 58
The state of the art for the modern dentists
Line/Width.: this function allows to effect the measure of the width of a part of the image.
To cancel an effected measurement is necessary to make click with the left button of the
mouse on the measurement to cancel and press the key Canc" of the keyboard.
Line and Width / Height.: this function allows to effect the measure of the width and the
height of a part of the image.
To cancel an effected measurement is necessary to make click with the left button of the
mouse on the measurement to cancel and press the key Canc" of the keyboard.
To cancel an effected measurement is necessary to make click with the left button of the
mouse on the measurement to cancel and press the key Canc" of the keyboard.
Angle: this function allows to calculate the angle of a part of the image.
To cancel an effected measurement is necessary to make click with the left button of the
mouse on the measurement to cancel and press the key Canc" of the keyboard.
Parallel lines: this function allows to calculate the distance among two parallel lines.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 59
The state of the art for the modern dentists
- put the cursor of the mouse in the point from which you want to start the measurement and
press the left key of the mouse;
- put the cursor of the mouse in the point of arrival of the measure and press the left button of
the mouse.
- proceed in the same way to draw the parallel straight line.
To cancel an effected measurement is necessary to make click with the left button of the
mouse on the measurement to cancel and press the key Canc" of the keyboard.
Calibrate: this function allows to calculate the correct measure of a part of image.
Pic. 7.15
IMAGES: IMPLANT
ADVICE:
The implant simulation doesn't owe a diagnostic tool but only a tool of visual evaluation.
Pic. 7.16
Pressing the button an implant will be added for the inferior arcade as shown by the
following figure:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 60
The state of the art for the modern dentists
Pic. 7.17
To move the implant in the correct position it is necessary to press the left button of the
mouse and, holding pressed the button, move the implant in the correct position.
To modify the inclination of the implant it is necessary to position the cursor of the mouse in
the low part of the implant, when it becomes an arrow, press the left button of the mouse and
change the inclination of the implant.
Pressing the right button of the mouse on the implant the following window will appear:
Pic. 7.18
Pic. 7.19
ADVICE:
Also in this case, the measures of the implant are to consider as indicative, not being possible to
guarantee its accuracy.
Choose the correct Diameter and Height of the implant and than press “Update”.
Pressing the button an implant will be added for the superior arcade as shown by the
following figure:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 61
The state of the art for the modern dentists
Pic. 7.20
Pressing the button you can add an object, choosing the folder from which you want to
import the object.
Pressing the button all the inserted implant will be eliminate. To confirm the effected
choice the following question will appear:
Pic. 7.21
Pic. 7.22
Arrow: this function allows to insert on the image arrows inserting besides a text that will
appear next to the arrow.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 62
The state of the art for the modern dentists
Pic. 7.23
To cancel the insertion of the arrow with the text is necessary to make click with the left
button of the mouse on the arrow to cancel and press the key Canc" of the keyboard.
To cancel the insertion of the text is necessary to make click with the left button of the mouse
on the text to cancel and press the key Canc" of the keyboard.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 63
The state of the art for the modern dentists
IMAGES: FILTERS
ADVICE:
The application of filters to the images can introduce artificials that compromise the diagnosis. For this
reason the diagnosis must exclusively have effected on the original image.
Pic. 7.24
Area Filter: pressing this button will open the following menu
Pic. 7.25
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 64
The state of the art for the modern dentists
Soft tissues DX: pressing this button it will be possible to underline the soft tissues of the
right part of the image. It will appear on the image a vertical straight line that can be moved
to the right or to the left according to the demands as shown in the following figure:
Pic. 7.26
Soft tissues SX: pressing this button it will be possible to underline the soft tissues of the left
part of the image. It will appear on the image a vertical straight line that can be moved to the
right or to the left according to the demands.
Selection rectangle: this function allows to select a rectangle of the image to filter.
Pic. 7.27
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 65
The state of the art for the modern dentists
Selection circle: this function allows to select a circle of the image to filter.
Also in this case there will be the possibility to select one of the followings filters
Pic. 7.28
IMAGES: ZOOM
ADVICE:
The dimension of the image represented to video never has to be considered as an exact report in
comparison to the real dimension of the image. it is not possible to measure the image with rulers or
other tools supported to the monitor.
Pic. 7.29
Zoom Area: this function allows to enlarge only the part selected of the image.
Lens: this function allows, holding pressed the left key of the mouse on the image, to enlarge
the parts of the image touched by the cursor of the mouse.
Fit to page: this function allows to fit the image to the page to visualize completely the
image.
Fit Vert.: this function allows to vertically fit the image to the page.
Fit Hor.: this function allows to horizontally fit the image to the page.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 66
The state of the art for the modern dentists
IMAGES: ORIENTATION
Pic. 7.30
Mirror horizontal: this function allows to effect the speculate horizontal of the image.
Mirror vertical: this function allows to effect the speculate vertical of the image.
Rotation 90° to the left: this function allows to rotate to the left the image of 90°.
Rotation 90° to the right: this function allows to rotate to the right the image of 90°.
IMAGES: UTILITIES
Pic. 7.31
Export: this function allows to export the image. It will open the following window
Pic. 7.32
Insert the name of the file and press "Save", the image will be saved. You can export an
image in dicom format.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 67
The state of the art for the modern dentists
Medical Report: this function allows to insert notes to the image as shown in the following
image
Pic. 7.33
Select the category of the image, insert the annotations and press .
Print: this function allows to print the visualized image. It will open a window of preview of
print in which it can be select the printer and the picture size. If you have the Dicom extension
of the application, you can print on a dicom printer also.
Send to CD: this function allows to send the image to the CD. The image is added at the other
sent before. When the application burn the CD it include a Viewer.
Send via email: this function allows to send the image via email. It will open the following
window
Pic. 7.34
NOTE:
Dental Studio Plus® doesn't send away directly the images via email but it prepares them so that can be
sent through your default e-mail program. The settings out of the account of e-mail and all the safety
settings out must be verify in your e-mail program.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 68
The state of the art for the modern dentists
Insert the name of the file and the format of the file, if Bit-map, JPEG or DICOM and press
, it will open the following window for the dispatch of the e-mail
Pic. 7.35
Send to PACS: this function allows to send the image to the PACS Server.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 69
The state of the art for the modern dentists
IMAGES DATABASE
Pic. 7.36
Pic. 7.37
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 70
The state of the art for the modern dentists
The batch file is the representation of the patient’s associated images, not
organized in a specify mode. The only organization is the sequence, without
dental association. The visualization is possible using the lateral scroll bar.
The ordination is by insertion date: the most recent will be the first of the
list.
Every time you select a patient, you can see the preview of all the images.
This operation should be slow if the images file is too big, so you can
organize the visualization in program setup.
To elaborate the images of the batch file you have to double click on the
image preview. In this way the image will be zoomed in the elaboration
window for a better visualization. The program allows the contemporary
zoom of more images. These will be showed all together in the elaboration
window, just like in Pic. 7.37.
Pic. 7.38
AVDICE:
Dental Studio Plus® deletes the images in irreversible way. Before deleting the images it will have asked
you a confirmation. If the delete is confirmed it won't be more possible to restore the deleted images
only from a backup copy.
Pic. 7.39 Slide show: it starts a full screen slide show of all the images. This
function is useful to create a collection of images o f a specific
treatments to the patient. It is possible to control the presentation
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 71
The state of the art for the modern dentists
b. IMAGES: Schematic
Click on
Pic. 7.40
Here you can find a box for every tooth. Every box can contain 20 images. Under every box
you can see the number of images inserted in. To insert an image in a box, you have to drag it
from the batch file
Clockwise rotation.
Flip vertical.
Mirror horizontal.
Negative/positive.
Delete image.
Pic. 7.41
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 72
The state of the art for the modern dentists
The preview window still opened for a few second. To let the window opened, you have to click
on the box, or clicking for a few second. To close a window click on another box or on any
other part.
the showed imaged will become the first in the preview window.
In the upper part (pic. 7.41) there is the navigation bar for the box images
iv. Fast rewind of images
v. Slow rewind of images
vi. Slow forward of images
vii. Fast forward of images
The number that compares in left bar indicate which is the image in box preview.
c. IMAGES: Status
Pic. 7.42
Disposal and dimension is free and you can change it in every moment, clicking on
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 73
The state of the art for the modern dentists
Pic. 7.43
Negative/positive
To move the box, simply drag it till the position you desire.
To change the box dimension, simply click on low right corner and drag till the dimension you
desire.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 74
The state of the art for the modern dentists
Pic. 7.44
Pic. 7.45
In left list appears the drive configuration. To find a configuration on another drive, you have
to select it in the lists above.
If you want to use this configuration as default, you have to confirm it clicking on Use
selection as default.
Save: save the disposal active on a file. The files name is free editable.
Print: print the active window. We suggest you the horizontal orientation of printer to obtain a
better result.
Option: change the printer margin, delete the status and select header.
d. Elaboration of images
ADVICE:
The application of filters to the images, the calibration of the measures, the change of contrast and
brightness and all the functions that modify the images, can introduce artificials that compromise the
diagnosis. For this reason Dental Studio Plus® always preserves the original copy of the image to
which is had to make reference for the diagnosis.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 75
The state of the art for the modern dentists
Pic. 7.46
Clicking here you can arrange the images windows, to view all of them without superimposition
of the images.
You can annotate all that you want. To save click on Ok.
The text written in the first line, will be reported in image preview. The images category will be
used for the previews visualization.
Pic. 7.47
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 76
The state of the art for the modern dentists
Pic. 7.48
Pic. 7.49
After the click on Zoom on images, you can activate the Zoom options function.
Zoom: it is possible to zoom 5 different images in contemporarily. If you select zoom x1 you
obtain the real dimension filter.
Negative: it applies the inversion of colours filer (from negative to positive or vice versa).
Contrast: it contrasts more the image in the portion visualized by the lens.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 77
The state of the art for the modern dentists
Emboss: it applies the emboss filter to the portion visualized by the lens.
Detail: it applies the detail filter to the portions visualized by the lens.
Detail and Virtual Colours: it applies the detail and virtual colours filter to the portion
visualized by the lens.
Contour detection: it applies the contour detection filter to the portion visualized by the lens
Pic. 7.50
It modifies the contrast and the brightness of the image using the “gamma factor”. This way is
much more definite than the simple contrast/brightness function. The gamma factor is an
exponential function and not a linear one, so it can better optimize the images. To modify the
contrast and the brightness bring the mouse in the middle of the image, then click and keep
clicked on with left click. Move the mouse to modify contrast and brightness.
Decrease contrast
Increase contrast
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 78
The state of the art for the modern dentists
IMAGE ORIENTATION
Click on
IMAGES: 3D SIMULATION
Using this function you can value the X-Ray as a 3D vision. The calculating of third dimension
is based on radio-opacity, that is the X radiation quantity that is passed trough the object.
The 3D image is visualized in a dynamic way, so you can change the point of view.
Click on
Pic. 7.51
- Bring the mouse in the middle of the image then left click;
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 79
The state of the art for the modern dentists
- Keeping pressed, move the mouse on horizontal/vertical axis to modify the point of
view;
- Modify the height with the cursor in the right part of the window;
- Click on close to go back to the starting image.
This function analyze the images RGB values. Moving the mouse on the image, it shows the RGB
value of one small portion under the mouse indicator.
IMAGES: MEASURE
ADVICE:
The radiographies are a bidimensional representation of three-dimensional object places in the space,
therefore their representation can be deformed in function of various factors, what enlargement, relative
position of the object in comparison to the receptor of image, etc. These factors don't allow therefore a
precision quantifiable of the trial.
Dental Studio Plus® is not a tool of measure because, also after the procedure of calibration
of the measure in comparison to a known repere, the accuracy of the same measure cannot
be guaranteed, that therefore it has to be considered as indicative.
Pic. 7.52
Measure an angle
This function permits the measure of the angle made between two segments
measure.
Measure a circle
Bring the mouse corresponding of the centre of the diameter you want measure;
Left click while drag the mouse to increase/decrease the diameter.
This function measure the density, or better the radio-opacity (grey level), of a line
indicated with the mouse
Grid
Pressing you can specify the greatness of the squares of the grate.
Delete
Calibrate
Zoom
Pic. 7.53
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 81
The state of the art for the modern dentists
This function permits to visualize the image to full screen. To go back left click or press ESC from
the keyboard.
From the Utilities menu press the Print button, a printing preview window will be opened.
Pic. 7.54
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 82
The state of the art for the modern dentists
Select Layout: allows you to select the correct layout according to the "Film Size" from a
drop-down menu;
Select the printer: allows you to select the preferred printer (Windows or Dicom) from a
drop-down menu;
Annotation: allows you to insert some comments that will be shown in the printing area.
Pic. 7.55
If no sensor has been indicated, the configuration will be appeared. Answering YES to this
question
Pic. 7.56
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 83
The state of the art for the modern dentists
Pic. 7.57
You have to select your sensor, with all them parameters. For more details on the sensor
functioning, ask to your technician.
You can open the configuration in a second time clicking on Options (Pic. 7.57).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 84
The state of the art for the modern dentists
Clicking on Videocamera, the software will try to find a videocamera connected to the
computer. If it will find it, it will try to utilize it using the typical configuration. Anyway it is
possible to personalize the configuration.
Pic. 7.58
Pic. 7.59
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 85
The state of the art for the modern dentists
Pic. 7.60
Change from single image modality to movie acquisition and vice versa
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 86
The state of the art for the modern dentists
Move the mouse on the lower bar to show the menu (Pic. 7.62)
Pic. 7.61
The lower part (Pic. 7.62) in subdivided in single images captured and videos. To save the
images or the videos you have to select with right click on the image then select Save.
The not saved images, are eliminated when you close the window.
The Panoramic to use must be configured from Options menu of images window. Here below an
example. If no digital panoramic is selected, the software will ask you:
Pic. 7.62
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 87
The state of the art for the modern dentists
Pic. 7.63
After you confirmation (in the example we have simulate the Rotograph EVO 3D Panoramic)
Pic. 7.64
The virtual keyboard allows to command the panoramic directly from your computer (except
all the mechanical movement, for the patient safety). Starting the image acquisition, the image
will be automatically moved to the patient’s archive, with a preview visualization during the
acquisition.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 88
The state of the art for the modern dentists
Pic. 7.65
It is necessary to select the scanner then click on Scan. The window will be opened, on
respective the scanner you have. For detailes please see to the Operative Manual of the
scanner.
Pic. 7.66
It is necessary to browse the drive and the fotocamera file (connected to the computer); verify
the image clicking on the image name then look to the preview. Click on Import to import a
single image or on Import all to import all the images in the directory. The images will be
saved in patient’s archive.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 89
The state of the art for the modern dentists
Pic. 7.67
It is necessary to browse the drive and the directory where the images are saved.
Verify the image is clicking on the image name then look to the preview. Click on
Import to import a single image or on Import all to import all the images in the directory.
The images will be saved in patient’s archive.
Clicking on Find you can select the directory you want to import: in the left part of the
window will be listed all the images in that directory. Left click on the image for look at the
selected image preview. Select the image then click on Import. The image will be saved in
patient’s archive.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 90
The state of the art for the modern dentists
Dicom size is for example the TAC format. Some Hospitals use this size to save all the Image
type.
Dicom size is also a filing method. It is possible to buy modules that save the data on a remote
server (Dicom store), or that print in remote (Dicom print), or that find again an image on a
remote server (Dicom retrive).
Pic. 7.68
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 91
The state of the art for the modern dentists
8. UTILITY
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 92
The state of the art for the modern dentists
UTILITY
Pic. 8.0
Pic. 8.1
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 93
The state of the art for the modern dentists
Program setup
Pic. 8.2
Click on your language button. If your language has not its button, select it from the dropdown
list.
Not all the languages are available.
Working parameters
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 94
The state of the art for the modern dentists
Remote control
At next start, the software will show the remote control (Pic. 8.3)
Pic. 8.3
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 95
The state of the art for the modern dentists
Pic. 8.4
This function allows to insert the header at the image and at the document of the cabinet.
IMAGES
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 96
The state of the art for the modern dentists
Pic. 8.5
Storage
The file format is ignore for the Dicom store file format option.
Image database fixed: WARNING! If you don’t know the exactly functioning of this
function, don’t active it!
This option makes you able to divide the image database from the personal data of the patient
database. The one reason for active this function, is little drive capacity. If you use a ZIP drive
or a USB drive as archive, it is possible that you fill in low time, if you save the image too. For
this reason you can decide to save the image in the internal hard disk, and the personal data
in an external one. When you active this function you have to specify the directory address to
save the images. Dental Studio Plus® will save all the images in this directory, separating for
patient.
Dental Studio Plus® will save all the patient data on the selected drive (F);
In C:\Images it will create a subdirectory that will have as name a code assigned from
the software;
All the images will be saved in the created file (C.\Images\Drive Code).
Important: after the activation of this option, Dental Studio Plus® will manage all the drive in
the same way. If in your drive, you just have some images, please call the customer care
service.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 97
The state of the art for the modern dentists
It permits the image management activation trough another software. Generally the external
software are the applicative supplied with the X-Ray system. For more details please contact
the customer care service.
NETWORK
Pic. 8.6
TERMINAL SERVER
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 98
The state of the art for the modern dentists
Pic. 8.7
DICOM
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 99
The state of the art for the modern dentists
Pic. 8.8
BACKUP DATABASE
Pic. 8.9
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 100
The state of the art for the modern dentists
ADVICE:
We advise you to perform the backup of the data every day. This will make your job more safe over
whether to make you to respect how it is foreseen by the norms on the privacy.
You have the possibility to make the Dental Studio Plus® data backup; in this way, in
critical moment, you can restore all your data.
Original source: it indicates the letter identification of the drive that contains the images to
save.
Destination drive: it indicates the letter of the drive where to save all the data.
Copy all the database: it specifics that the database will be copied in the destination
drive.
Tabs copy: it specifics the selected tab will be copied from the tabs list
Subdirectory copy: it permits to select the destination file.
Standard copy: it copies a database for time.
Multiple copy: it copies more database for time.
Start copy: it starts the copy with the parameters indicated.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 101
The state of the art for the modern dentists
DATABASE RESTORE
NOTE:
The restore of the database performs a backup copy of the data before the real
regeneration. In this way the safety of the data is preserved in case of failure of
the procedure of restore.
Pic. 8.10
Using this function you can make the upgrade of yours database. Simply selecting the drive
where create/upgrade the database, than click on Start. The software scans all the voices and
automatically upgrades. When the procedure is finished, click on Close.
This option is activable too from drive section. For more details, please look at “Drive
management” section.
REPAIR DATABASE
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 102
The state of the art for the modern dentists
Pic. 8.11
Using this function you can repair your database in case of damage. Simply selecting the drive
and choose if make the verify or directly start to repair. When the procedure is finished, click
on Close.
Repair Database
Repairs all the database of Dental Studio Plus®.
Repair Tables
Repairs all the tables used from Dental Studio Plus®.
PATIENT COPY
Pic. 8.12
Using this function, you can copy or move a patient from a drive to another one.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 103
The state of the art for the modern dentists
Proceed selecting the drive source; select the destination directory. Select a patient to
move/copy then click on Copy.
During the copy, if Dental Studio Plus® finds the patient already present in the
destination drive, it will ask you if you want to upgrade it or not. The same if it find a
planned treatment or a date.
The question has always more solutions. Make attention to select the corrected one, because the
operation is irreversible.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 104
The state of the art for the modern dentists
9. 3D IMAGES
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 105
The state of the art for the modern dentists
EVO 3D TS CONFIGURATION
To configure Dental Studio Plus to acquire images from Evo3D TS the following configuration
set up has to be done.
Pic. 9.a
6) In the “Panoramic configuration” windows select the Rotograph EVO 3D and set the proper
IP address of the DSPU board and the TSEVO Touch Screen.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 106
The state of the art for the modern dentists
Pic. 9.b
7) Click “OK”
8) press the button “TAC” to acquire an exam from Rotograph EVO 3D TS. The Virtual keyboard
is displayed.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 107
The state of the art for the modern dentists
Note: not all modules are active in every software some of them is optional depending on
license configuration. Check the module you selected in set-up is active for your license.
5)Confirm with OK
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 108
The state of the art for the modern dentists
Pic. 9.c
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 109
The state of the art for the modern dentists
Pic. 9.d
Use
The Dental Studio plus automatically opens OnDemand3D or Implant3D or Villa 3D Planner
software loading the 3D case selected by the user.
After acquisition
After a 3D exam acquisition the Dental Studio plus software automatically opens its 3D
module.
To open OnDemand3D or Implant3D or Villa 3D Planner software:
1)select the "Project" menu (figure B)
2)click on "OnDemand3D" or “Implant3d” or “Villa 3D Planner” button (NOTE this is the default
name of the button it may differ if a different text was typed at step 2) of set-up procedure).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 110
The state of the art for the modern dentists
Pic. 9.e
Pic. 9.f
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 111
The state of the art for the modern dentists
In a second time
To open OnDemand3D or Implant3D or Villa 3D Planner directly from the patient image folder
(figure D):
1)select the 3D exam with mouse left click;
2)right click on it and a menu is opened;
3)left click on "OnDemand3D" or “Implant3D” or “Villa 3D Planner” button (NOTE this is the
default name of the button it may differ if a different text was typed at step 2) of set-up
procedure).
Pic. 9.g
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 112
The state of the art for the modern dentists
Pic. 9.1
3D Module: 3D IMAGES
ADVICE:
The reconstruction of the paraxial images happens on the perpendiculars of the panoramic curve drawn
by the user. The distance among the reconstructed cuts and the dimension of the perpendicular segment
to the panoramic curve, that it determines the width of the cross section image, are configurable
parameters from the user.
The maximum error produced by the reconstruction is equal to two pixels. The error maximum convert
in measure is equal to the dimension of the voxel in the axial plan of the axial image multiplied for two.
The dimension of the voxel, converted in millimeters, it is accessible from the menu "Project" to the
voice "Information Project". The parameter "Thickness image" it points out the dimension in
millimeters of the voxel. Supposing a dimension of the voxel of 0.170 mms, the maximum error
introduced by the reconstruction will be equal to 0.170 xes 2 = 0.340 mms.
The error of the reconstruction is the theoretical error supposing that the patient has correctly been
positioned, according to the indications of the furnished by the producer of the radiograpic instrument,
and that the reconstruction has gone to good end.
Dental Studio Plus® is not a tool of measure because, also after the possible procedure of
calibration of the measure in comparison to a known repere, the accuracy of the same
measure cannot be guaranteed, that therefore it has to be considered as indicative.
Click this button to import the exam. The application will show the following window:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 113
The state of the art for the modern dentists
Pic. 9.2
Select the folder or the CD in which the images are saved and press the button “Starts
search”. The application will search in the selected path and in any subfolder for any exams. If
you won't find any exams, you can try to uncheck the option that allow to search only in file
with “.DCM” extension. If any exams will be found, the application will display all the found
exams with a short description. To open the preview of the exam you can double click on the
reference in the list.
Pic. 9.3
If you want to import the exam showed in the preview windows, please click on “Confirm”.
The application will import all the axials images of the selected exam. When it finish to import
the images in the patient's database, the application will automatically start the 3D
reconstruction.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 114
The state of the art for the modern dentists
Pic. 9.4
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 115
The state of the art for the modern dentists
ADVICE:
The information used by Dental Studio Plus® to perform the 3D reconstruction and the calculation of all
the view are acquired by the axial images. If these informations are wrong it will have been resulted not
forseeable.
3D Module: Warning.
The 3D reconstruction uses the information of the axial images. If this information are wrong
or they contain any mistake, unpredictable result are expected.
This module is intended only for evaluation and this is not a system fir surgery application.
The maximum error that this application will introduce is 2 pixels. The maximum linear error is
the pixel size * 2.
The first step of the 3D reconstruction is to draw the panoramic arc. The panoramic arc is a
curve that represent the position of the dental arc. Before you start drawing the panoramic
arc, please select an axial image with the bone. The optima position of the panoramic arc is in
the middle of the bone tissue.
To draw the panoramic arc on the axial image press the following button
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 116
The state of the art for the modern dentists
Move the mouse arrow on the image and press the left button to set all the points of the
panoramic arc. When you finish to draw the panoramic arc press again the button. The
application will calculate all the cross sections and the panoramic section.
You can also use this option to modify an existing panoramic arc. To modify any point, move
the mouse arrow on the point to move, click with the left mouse button and drag it to the new
position.
Moving the scroll bar of the cross images, you can show the cross images around the
panoramic arc. In the same time the application will draw the references of the selected cross
on the axial view and on the panoramic view. You can also change the active cross section
clicking on the panoramic view.
Pic. 9.6
If you need to hide the panoramic arc, uncheck the option “Display Arc”. If you want to hide
the cross image near the axial view uncheck the option “Display Cross.”
Press this button to delete the panoramic arc and to draw a new one.
NOTE:
The visualization of the axial images is orderly as if the patient was observed by the feet toward
the head.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 117
The state of the art for the modern dentists
- Scroll the images from top to bottom and bottom and from bottom to top. To scroll the
images you can use the scroll bar on the right of the axial images or you can use the mouse
wheel.
- Arrange the brightness and contrast. To modify these values click and hold the right mouse
button and move it on the axial image. These changes will affect all views.
- Press the CTRL key and hold it, than press the left mouse button. The application will display
the information for the pixel position and the pixel gray level value.
Create a snap shot of the current axial. The snap shot repository can be used to create
a medical report.
3D Module: 3D VIEW
- Rotate the orientation. Click and hold click the left mouse and move it. The volume
orientation will change according the mouse movement.
- Zoom in and out. You can use the mouse wheel to enlarge and reduce the 3D volume view.
- Click and hold the mouse wheel and move the mouse. The volume will move according the
mouse movements.
- Change the gray level represented. On the top of the 3D view the is a range selector that
allows you to select the minimum and the maximum gray level to display. This option is very
important to select the tissue density to display. You can display for soft tissue, moving the
range selector to the left, for metals, moving it to the right.
In the 3D menu “3D Options” there are al the function for the 3D view.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 118
The state of the art for the modern dentists
Pic. 9.7
3D Module: MPR.
This function allows to visualize the sections of the image moving the perpendicular lines.
Pic. 9.7a
Find a position for the range selector to display the most important informations.
Enable / Disable the stereo 3D option. When this option is enabled you can see a real 3D
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 119
The state of the art for the modern dentists
image. To get the correct effect you need special glasses with one red and one green glass.
3D Module: 3D MIP.
Display the 3D MIP (Maximum Intensity Projection). This option allow you to see inside the
volume.
Pic. 9.8
To crop the volume you should move the mouse near on of the green marker, press the left
mouse button, hold it and move the mouse to crop the volume.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 120
The state of the art for the modern dentists
Create a snap shot of the current volume. The snap shot repository can be used to
create a medical report.
- Scroll the images from top to bottom and bottom and from bottom to top. To scroll the
images you can use the scroll bar on the right of the axial images or you can use the mouse
wheel.
- Arrange the brightness and contrast. To modify these values click and hold the right mouse
button and move it on the cross image. These changes will affect all views.
- Press the CTRL key and hold it, than press the left mouse button. The application will display
the information for the pixel position and the pixel gray level value.
Create a snap shot of the selected cross images. To select the cross images click with
left mouse button in the top-left if the image box.
Pic. 9.9
The yellow marker inform you that the image is selected. To unselect the image click on the
yellow box.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 121
The state of the art for the modern dentists
If you want to zoom a single cross image check the box “Single”.
The application will display a single cross image.
Pic. 9.10
The panoramic view contains the panoramic section calculated around the panoramic arc.
Pic. 9.11
To change the panoramic arc of interest you can use the scroll bar on the right. If you want
know the position of the active panoramic section you can see the axial view.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 122
The state of the art for the modern dentists
Pic. 9.12
The green arc represents the original panoramic arc, the one created from the user. The red
arc represents the arc calculated and displayed the in current panoramic section view.
Create a MIP (Maximum Intensity Projection) of the Panoramic view. The final image is
created starting from all the panoramic arcs.
Pic. 9.13
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 123
The state of the art for the modern dentists
In the full cross view, the application creates two sections. Both sections are created from the
axial image dataset.
Pic. 9.14
The top section is created from the right to the left of the patient (L/L view). The bottom
section is created from the anterior to the posterior of the patient (A/P view)
The background colour helps the user to identify the reference line in the other view. Any line
create in any view has the same colour of the source data. For example in the axial view the
light green line represent the full cross A/P.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 124
The state of the art for the modern dentists
The 3D cross view is a very innovative 3D reconstruction. This reconstruction uses the cross
images to create a 3D volume.
Pic. 9.15
The 3D image is created using 18 cross frame. It is possible to use 9 frames also, unchecking
the option “Extend”.
In the top of the 3D View there is a range selector. Moving the minimum and the maximum
position of this selector, you can select the tissue density to evaluate. If you move it to the left
you will enhance the soft tissue. If you move it to the right you will enhance the hard tissue.
- Rotate the orientation. Click and hold click the left mouse and move it. The volume
orientation will change according the mouse movement.
- Zoom in and out. You can use the mouse wheel to enlarge and reduce the 3D volume view.
- Click and hold the mouse wheel and move the mouse. The volume will move according the
mouse movements.
If you check the option “MIP” you will see a transparent volume.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 125
The state of the art for the modern dentists
3D Modules: Hounsfield
The Housfield method display the cross using pseudo colours. These colours will help you to
better know the tissue quality. The classification is: D1, D2, D3, D4.
D1 represent the softest density and D4 the hardest density.
Pic. 9.16
If you double click on any images the application will move the images on a new window, In
this window you can zoom the images.
ADVICE:
The visualization of the Housfied (HU) unites doesn't reflect the corresponding visualization
of the HU unities obtainable with the TC system because the software has not been projected
for a correct visualization of HU unit-
The Ceph view create two Ceph projection: A/P and L/L.
The source data are the axial images. This projection are created using all axial frames.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 126
The state of the art for the modern dentists
3D Module:Menu Project
Pic. 9.17
Save the current project, It saves the panoramic arc and the view option. The cross images
and the panoramic images are not saved but they are created any time you will open again the
project. This method ensure to avoid any problem.
Restore the project to the original data. Any modification to the axial images are deleted. The
panoramic arc is deleted included any cross and panoramic sections.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 127
The state of the art for the modern dentists
Open a powerful editor to modify the axial images. This edit is very useful to clear the metal
artefact from the images.
Pic. 9.18
Select the image from which you want to start to make the changes and press “Tag Begin”.
Scroll the images using the scroll bar or the mouse wheel to select the last image that you
want to modify. Press the button “Rubber”, a green circle it will appear that represents the
size of the rubber that is wanted to use. To modify the rubber size select the size in the left
part of the following window:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 128
The state of the art for the modern dentists
Pic. 9.19
It is also possible to modify the threshold and the level of the rubber and its size. To work on a
single image just click the left mouse button and holding it move around the image. If you
want to word on multi image, holt the CTRL key before click the left mouse button.
To clear a parts of the image it is necessary to move the rubber on the point of the image that
you want to modify and, holding pressed the left button of the mouse, move the rubber on the
part of the image to cancel.
Export the slices (axial images) to a folder selected from the user. When the export process is
finished the application will open the destination folder automatically.
Report the project information. The tag DICOM of the acquired 3D image.
Send the image data to the PACS when a DICOM server is configurated
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 129
The state of the art for the modern dentists
Rebuild the acquired 3D image starting from the raw file with the filtering options setted in the
following menu:
This button opens the Implan3D or OnDemand3D software (see the SET UP paragraph )
NOTE:
Dental Studio Plus® effects the volumetric reconstruction (or 3D) of the maxillo-facial complex departing
from DICOM images gotten with special softwares (Dentascan or similar coming from TC) or that use the
technology ConeBeam CT.
The volumetric reconstruction effected by Dental Studio Plus® is checked by the contained parameters
in the DICOM images of departure.
Dental Studio Plus® performs an accurate control of such parameters but it cannot guarantee the
correctness and accuracy, that depend on the system that has performed the examination, therefore
the measures have to be considered as indicative.
The volumetric reconstruction can only be used in the systems of implant planning when the
instructions are followed given by the provider of the system of planning.
Particularly, the images used to this purpose have always to include the relative support used
by such systems for the calibration of the geometric ownerships of the system.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 130
The state of the art for the modern dentists
Pic. 9.20
The selected measure tool will work on many view: Axial view, Panoramic view, and cross
view.
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
- move the mouse cursor in the point from which you want to start the measurement and
press the left key of the mouse;
- move the mouse cursor in the final point of the measure and press the left key of the mouse;
it will appear the effected measure.
To finish the measurements process press the right button of the mouse.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 131
The state of the art for the modern dentists
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
Line/Width.: this function allows to take the measure of the width and the distance.
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
Line and Width / Height.: this function allows to take the measure of the width and the
height and the distance.
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
Angle: this function allows to calculate the angle included in two segments.
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 132
The state of the art for the modern dentists
Parallel lines: this function allows to calculate the distance among two parallel lines.
- move the mouse cursor in the point from which you want to start the first segment and click
with the left mouse button.
- move the mouse cursor at the end point of the first segment and click with the left mouse
button.
- move the mouse cursor in the first point of the first segment and click with the left mouse
button.
- move the mouse cursor at the end point of the second segment and click with the left mouse
button.
To delete an existing measurement it is necessary to click with the left mouse button on the
measure to remove cancel and press the key “Canc" from the keyboard.
Pic. 9.21
Arrow: this function allows to insert on the image arrows inserting besides a text that will
appear next to the arrow.
Pic. 9.22
Insert the text that you want to show near the arrow and press .
To delete an arrow with the text, click with the left button of the mouse on the arrow and
press the key “Canc" from the keyboard.
- move the mouse cursor on the bottom right position of the area where to insert the text and
to press the left button of the mouse;
- Insert the text and press .
To delete an text click with the left button of the mouse on the arrow and press the key “Canc"
from the keyboard.
Pic. 9.23
Full LUT: Select the standard lut to display the preset bone tissue.
Stereo 3D: Apply the elaboration to display a real 3D image. To have the 3D simulation you
need to uses special 3D glasses with a red glass and a green glass.
3D MIP: Apply the Maximum Intensity Projection calculation to display the image using the
transparence.
LUT Standard: this function allows to apply the LUT Standard, using the standard gray levels.
LUT Bones + Tissues: this function allows to apply the LUT to enhance the bone tissue and
the muscle tissue.
LUT Bones: this function allows to apply the LUT to enhance the bone tissue.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 134
The state of the art for the modern dentists
Pic. 9.24
This function allows to modify the size of the cross images. To apply a new value you need to
modify it and press “Regenerate Cross”
To save all the captured images you can use the button “Save All” in the top of the screen.
To delete all the captured images you can click on “Delete All” in the top of the screen.
To save all the captured image for the selected category you can click on “Save All” on the
right of the screen.
To delete all the captured image for the selected category you can click on “Delete All” on the
right of the screen.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 135
The state of the art for the modern dentists
Pic. 9.25
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 136
The state of the art for the modern dentists
Pic. 9.26
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 137
The state of the art for the modern dentists
Pic. 9.27
Pic. 9.28
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 138
The state of the art for the modern dentists
Pic. 9.29
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 139
The state of the art for the modern dentists
Pic. 9.30
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 140
The state of the art for the modern dentists
The “Capture image” button allows you (when you are in cross or axial windows) to
send a single image or a complete set of images from the current view to the “Image for
Report” temporary folder, in order to handle the printing capabilities in Dicom or Windows
mode.
Pressing the “Capture image” button the following popup menu will be displayed:
Pic. 9.31
Capture the current view: send the selected image from the current view to the “Image for
Report” temporary folder;
Capture all views: send all the images from the current view to the “Image for Report”
temporary folder;
Add rulers to captured images: allows you to enable or disable the ruler's view on the
selected image (or set of images);
Show all cross line reference on axial image: allows you to show over the axial image all
the reference cross lines, built from the panoramic arc.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 141
The state of the art for the modern dentists
- On the new window, press the “Captured Images” button in order to enter
to the “Images for Report” window:
Pic. 9.32
- Pressing the “Print” button the “Printer preview” window will be displayed.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 142
The state of the art for the modern dentists
Pic. 9.33
Select the layout: allows you to select the correct layout according to the “Film Size” from a
drop-down menu;
Select the printer: allows you to select the preferred printer from a drop-down menu;
Notes: allows you to insert some comments that will be shown in the printing area
NB: It's possible to create a report with multiple images on a single page only using the same
type of view (multiple axial, multiple cross, etc.). The most important Dicom tags (patient
informations, exposure parameters) will be automatically inserted into the print layout.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 143
The state of the art for the modern dentists
This operation permit to create a CD with a viewer. This allow you to open a 3D studies on
each PC without having licence key.
Pressing the "DICOM CD" button from the Dicom menu the following window will be displayed.
Pic. 9.34
Drag a single one or more than one study (according with the size of your phisical support, CD
or DVD) that you want to add to the temporary buffer into the “Dicom CD” window.
Click over the “Open Detail” button in order to see the previews list.
Pic. 9.35
Press the “Create CD” button then “Burn” and wait for the end of the job (a log message will
be showed when the burning process will be done).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 144
The state of the art for the modern dentists
If you want to rebuild a 3D study already acquired using different MAR settings than those
used during the acquisition, you can proceed as follows:
- open the 3D study;
- from the “Project” drop-down menu select “Rebuild Axials” function;
Pic. 9.37
NB: the “Rebuild Axials” function creates a new 3D study and the original one will be still
available under the patient examination list.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 145
The state of the art for the modern dentists
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 146
The state of the art for the modern dentists
For the details about these products refers to the specific User Manuals.
2. SENSOR SET-Up
To be able to use your Villa Intraorals system with the Dental Studio Plus imaging software
you have to configure your equipment as follows:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 147
The state of the art for the modern dentists
3. Press the button "Sensor1" to link your Villa Intraoral device to the button
"Intraoral 1" or "Sensor2" to link the to the button "Intraoral 2".
4. Set "Device type = Villa intraoral sensor". Press the button "Open
Configuration".
◄ Set the inlay and size of the date & time and exposure parameters in
the acquired image.
◄ Select the image treatment (*).
(*) When the “Film alike” option is activated, the contrast depends on the exposure time.
Adjust the X-ray dose on the generator to obtain a good image.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 148
The state of the art for the modern dentists
(*) When you select the option “Auto contrast” the contrast is constant. Exposure errors are
corrected automatically, which reveals noise in badly exposed images.
In both cases, the exposure bar (blue/green/red) helps to find the correct exposure of the
images.
In the Image Database window press “Intraoral 1 or 2” and the sensor toolbars will be
displayed as follows:
The colour of the sensor toolbars indicates the state of the unit:
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 149
The state of the art for the modern dentists
WARNING:
The unit automatically switches to standby mode after a few minutes of not being used;
the standalone toolbar turns red.
Check that the standalone toolbar is displayed in green before each acquisition.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 150
The state of the art for the modern dentists
11. APPENDIX
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 151
The state of the art for the modern dentists
Dental Studio Plus captures images directly from digital sensors, divided into the following tables
according to the type of sensors.
The table also specifies the versions of the computers’ systems that we have used to verified Dental
Studio Plus; this limitation depends on the manufacturer/supplier of the digital system and not on
the program.
ADVERTENCE:
For more safety, please contact our service center to check the compatibility of the image acquisition
system with Dental Studio Plus and with the computer system.
INTRAORAL VIDEORADIOGRAPHY
PANORAMICS
Windows 7 32 bits
Windows 8 32/64 bits
Windows 10 32/64 bits(1)
3D PANORAMICS
Manufacturer Version Type Computer Systems
Windows XP
1.0.0.0 Rotograph EVO 3D Windows Vista 32/64 bits
Windows 7 32/64 bits
Villa Sistemi Medicali
Windows 7 64 bits,
2.0.0 VSM Pano 3D Windows 8 64 bits
Windows 10 64 bits(1)
Windows XP
Bronnikov Algorithm 2.1.1.0 Rotograph Evo 3D Windows Vista 32 bits
Windows 7 32 bits
(1) The proven SDK version was not officially released for Windows 10 32/64 bits. The result is
defined based on the tests performed on a sample of at least 50 exams on two different computers.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 153
The state of the art for the modern dentists
Customizing prints.
ADVICE
This feature is designed for a user who is practical with prints and can create a
procedure containing fields and variables. The result of the creation of a print
template or modifying an existing one by a non-expert user, may cause
malfunction or may generate a print that is not consistent with the original image
and give unexpected results on the size. In any case, the image stored on the
hard disk remains unchanged.
Dental Studio Plus can only check the commands for correct syntax, but cannot
control the results of the customizations are correct.
Responsibility for the results of the press is exclusive of those who create it.
The access to this function is restricted to the administrator of the program.
Introduction.
To access to prints customization, please use the button SETTINGS that is in utilities page of the images module.
Fig. App2.1
At the top of the window you can select an existing template to check it or to change it. Selecting an existing model its
contents will be shown at the bottom of the window.
The "New" button allows you to create a new model.
The "Save" button allows you to save the model displayed. If the model does not have a name yet, you will be required
in the save phase. This name will be visible at print preview. We suggest you to save templates with names that are
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 154
The state of the art for the modern dentists
representative of their contents. For example the model "Ceph on A4 portrait" will indicate the pattern for Ceph print
images on paper in A4 portrait and so on.
The "Test Script" allows to visually verify the results of your script. In the simulation of the insertion of the image, the
program used always the same image. The result obtained in the printing phase may be different from that expected.
The customization of prints allows you to create any type of custom print format. You can print a single image, for
processing 2D prints, with the desired magnification and with the graphical presentation preferred. You can also create
customized printing for images from 3D processing.
The personalization of printing involves the use of:
Commands: a group of functions that is used to build the graphics printing pattern.
Variables: are values that change depending on the context of use of the print model.
Fields: are references to values associated with the images and the clinic.
Color: are the ones used in the context of the controls.
Commands
Here you are the commands that you can use to customize the printing format.
Box Draw a box to the coordinates specified, using the color set with the command
"CanvasColor"
CanvasColor Sets the color that will be used by the commands to draw
DefineMultiImageArea Draw a box to put the pictures to be printed in 3D elaboration
Font Set the font to use and its style
Line Draw a line in the required position
NewPage Set the size of the printing sheet
PenStyle Select the style of the pen used to draw lines
PutCenteredImage Inserts the image into the box indicated by the coordinates
PutExtLogo Insert the logo of the clinic by reading it from a bitmap file or a jpeg one
PutImage Inserts the image in the position shown with the features specified by the parameters
PutLogo Insert the logo of the clinic by reading it from a bitmap file or a jpeg one
TextCentered Writes a text in a rectangle, using the font style selected with the command "Font"
TextOut Writes a text, using the font style selected with the command "Font"
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 155
The state of the art for the modern dentists
Variables
Here you are the variables that you can use to customize the printing model.
PaperW It indicates the horizontal size of the paper read by the printer settings when
printing. During the creation of the model, this value is read from the setting
indicated by the command NewPage.
PaperH It indicates the vertical size of the paper read by the printer settings when printing.
During the creation of the model, this value is read from the setting indicated by the
command NewPage.
Fields
Here you are the fields that you can use to customize the printing model. These fields can be used in the text writing
commands.
<Patient> It represents the value of the last name and the name of the patient
<PatientBDate> It represents the value of the birth date of the patient
<PatientSex> It represents the value of the sex of the patient
<PatientAccNum> It represents the value of the Accession Number of the patient’s exam
<PatientCode> It represents the value of the patient’s code
<ExamDate> It represents the value of the exam date
<ExamTime> It represents the value of the exam hour
<ExamKV> It represents the value of the exam KV
<ExammA> It represents the value of the exam mA
<ExamDAP> It represents the value of the exam dose
<ExamUID> It represents the value of the exam UID
<ExamNotes> It represents the value of the exam notes
<ExamExpTime> It represents the value of the exposure time of the exam
<ExamType> It represents the value of the kind of exam
<ClinicName> It represents the value of the clinic name
<ClinicAddress> It represents the value of the clinic address
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 156
The state of the art for the modern dentists
Colors
Here you are the colors that you can use.
BLACK
MAROON
GREEN
OLIVE
NAVY
PURPLE
TEAL
GRAY
SILVER
RED
LIME
YELLOW
BLUE
FUCHSIA
AQUA
LTGRAY
DRGRAY
WHITE
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 157
The state of the art for the modern dentists
Command Box
Utilization Creation and execution of the script
Parameters Left: It indicates the position on the left of the box in millimeters
Top: It indicates the position on the top of the box in millimeters
Right: It indicates the position on the right of the box in millimeters
Bottom: It indicates the position on the bottom of the box in millimeters
Example Box (0.0, 0.0, PaperW, 20.0)
Draws a box from the upper left of the sheet, up to the width of the sheet to a height of 20
millimeters.
Description
This command draws a box at the coordinates specified using the color set with the command "CanvasColor". The edge
of the box will be drawn using the color "ForeG" set in the command "CanvasColor". The background of the box will
be drawn using the color "BackG" set in the command "CanvasColor". The definition of the coordinates can be of
numeric type, or the reference to variables: PaperW (page width) or PaperH (height of the page).
Parameters
Left: Indicates the position in millimeters of the far left point of the box. This value is expressed in the format xx.yy
(for example, 1.2 indicates that the box will be drawn at a distance of 1.2 mm from the left edge).
Top: it indicates the position in millimeters of the highest point of the box. This value is expressed in the format xx.yy
(for example 12:50 indicates that the box will be drawn at a distance of 12.50 mm from the upper edge).
Right: it indicates the position in millimeters of the far right point of the box. This value is expressed in the format
xx.yy (for example 100.0 indicates that the box will be drawn at a distance of 100.0 mm from the left edge).
Bottom: indicates the position in millimeters of the lowest point of the box. This value is expressed in the format xx.yy
(for example 200.0 indicates that the box will be drawn at a distance of 200.0 mm from the upper edge).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 158
The state of the art for the modern dentists
Command CanvasColor
Utilization Creation and execution of the script
Parameters ForeG: It indicates the position on the left of the box in millimeters
BackG: It indicates the position on the top of the box in millimeters
Example CanvasColor (Black, Red)
Draws a box from the upper left of the sheet, up to the width of the sheet to a height of 20
millimeters.
Description
This command sets the color that will be used by the commands for drawing. The colors to be selected are two:
foreground color and background color. The foreground color is used when drawing lines; the background color is used,
for example, to fill the box.
Parameters
ForeG: It indicates the color of the foreground (e.g.: Black).
BackG: It indicates the color of the background (e.g.: White).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 159
The state of the art for the modern dentists
Command DefineMultiImageArea
Utilization Creation and execution of the script
Parameters ImageZoom: it indicates the magnification to be applied to all images
ImageSpace: it indicates the horizontal and vertical space to leave between the images
Left: it indicates the position in millimeters on the left top of the box that contains the
images
Top: it indicates the position in millimeters on the top of the box that contains the
images
Right: it shows the position in millimeters on the right of the box that contains the
images
Bottom: it indicates the position in millimeters below the box that contains the images
Example DefineMultiImageArea (0.5, 2.0, 0.0, 25.0, PaperW, 200.0)
Defines a print area that will contain images with magnification of 50% (will be reduced by
half), with a space of 2 mm between each image and the coordinates of the area are: 0, 25,
PaperW (page width), 200.
Description
This command determines a box to insert pictures. This command can only be used for printing images captured with
the 3D module. It is used to print the axial, the cross, the panoramic cuts, etc. This command automatically determines
the number of pages you need to print all the selected images.
Parameters
ImageZoom: It indicates the magnification to be applied to all images. If you don’t want to apply any enlargement, you
must indicate "1.0". A value less than "1" reduces the image, while a higher value enlarges the image.
ImageSpace: It indicates the space that will be left between the images. This value is used for the horizontal and the
vertical space.
Left: It indicates the position in millimeters on the left of the box that includes images. This value is expressed in the
format xx.yy (for example, 1.0 indicates that the box of reference is at a distance of 1.0 mm from the left edge).
Top: It indicates the position in millimeters on the top of the box that includes images. This value is expressed in the
format xx.yy (eg 10.0 indicates that the box of reference is at a distance of 10.0 mm from the upper edge).
Right: It indicates the position in millimeters on the right of the box that includes images.
Bottom: It indicates the position in millimeters on the bottom of the box that includes images
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 160
The state of the art for the modern dentists
Command Font
Utilization Creation and execution of the script
Parameters Name: It indicates the name of the font you want to use. It must be included in the
installed ones.
Size: It indicates the size of the font you want to use
Color: It indicates the color of the font you want to use
Bold: It indicates if you want to use the bold option or not
0: not use; 1: use it
Italic: It indicates if you want to use the italic option or not
0: not use; 1: use it
Underline: It indicates if you want to use the underline option or not
0: not use; 1: use it
Example Font ("Trebuchet MS", 72, Red, 1, 0, 0)
Select the font “Trebuchet MS” with 72 size, using just the bold option.
Description
This command set the font you want to use and its style. The font choosen, will be used by all commands that provide
writing texts. To use more than one font in the same script, you have to use this command more than one time.
Parameters
Name: It indicates the name of the font you want to use (for example: Arial). The name of font must be written between
two apices. We suggest you to use “True type” fonts, that are scaled in a better way than other fonts.
Size: It indicates the size of the font you want to use (for example: 10).
Color: It indicates the color of the font you want to use (for example: Black). You can use the following colors: Black,
Maroon, Green, Olive, Navy, Purple, Teal, Gray, Silver, Red, Lime, Yellow, Blue, Fuchsia, Aqua, LTGray, DRGray,
White.
Bold: It indicates if you want to use the bold option or not. To select this option, you have to insert the value 1,
otherwise insert the value 0.
Italic: It indicates if you want to use the italic option or not. To select this option, you have to insert the value 1,
otherwise insert the value 0.
Underline: It indicates if you want to use the unerline option or not. To select this option, you have to insert the value
1, otherwise insert the value 0.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 161
The state of the art for the modern dentists
Command Line
Utilization Creation and execution of the script
Parameters Left: It indicates the position on the left of the line in millimeters
Top: It indicates the position on the top of the line in millimeters
Right: It indicates the position on the right of the line in millimeters
Bottom: It indicates the position on the bottom of the line in millimeters
Example Line (0.0, 110.0, PaperW, 110.0)
Draw an horizontal line starting from the left edge and at 110 millimeters from the top edge, for
the whole width of the paper.
Description
This command draws a line in the required position. Style and dimension of the line are set with the command
“PenStyle”, the color is determined by the command “CanvasColor” with the parameter “ForeG”.
Parameters
Left: It indicates the position in millimeters of the leftmost point of the line. This value is expressed in the format xx.yy
(for example, 1.2 indicates that the line will be drawn at a distance of 1.2 mm from the left edge).
Top: It indicates the position in millimeters of the highest point of the line. This value is expressed in the format xx.yy
(for example 12:50 indicates that the line will be drawn at a distance of 12.50 mm from the upper edge).
Right: It indicates the position in millimeters of the rightmost point of the line. This value is expressed in the format
xx.yy (for example 100.0 indicates that the line will be drawn at a distance of 100.0 mm from the left edge).
Bottom: It indicates the position in millimeters of the lowest point of the line. This value is expressed in the format
xx.yy (for example 200.0 indicates that the line will be drawn at a distance of 200.0 mm from the upper edge).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 162
The state of the art for the modern dentists
Command NewPage
Utilization During the creation of the script. It is ignored during printing
Parameters Width: It indicates the width in millimeters of the print area
Height: It indicates the height in millimeters of the print area
BGColor: It indicates the background color of the page
Example NewPage (210.0, 297.0, BLACK)
Creates a new A4 page with background color Black.
Description
This command is very important to create a print model. It must be listed as the first command of the script and must be
similar to the corresponding value of the paper you want to print. If you use many print formats you need to create
multiple scripts. This command is ignored during printing. The printer selected reads the actual size of the print area
automatically.
Parameters
Width: It indicates the width of the print area. This value is in millimeters, written in the format xxx.yyy (for example
210.0). To separate the decimal part from the integer part, use a point and not a comma.
Height: It indicates the height of the print area. This value is in millimeters, written in the format xxx.yyy (for example
210.0). To separate the decimal part from the integer part, use a point and not a comma.
BGColor: It indicates the background color of the page. You can set the background color you want to use. (for
example Black). Avaiable colors are: Black, Maroon, Green, Olive, Navy, Purple, Teal, Gray, Silver, Red, Lime,
Yellow, Blue, Fuchsia, Aqua, LTGray, DRGray, White.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 163
The state of the art for the modern dentists
Command PenStyle
Utilization Creation and execution of the script
Parameters Size: It indicates the thickness of the pen in millimeters
Style: It indicates the pen style
Example PenStyle (5.0, 0)
Select a pen thick 5mm and continuous
Description
This command set the style of the pen to draw lines. The settings of this command are used for all graphics command of
drawing.
Parameters
Size: It indicates the thickness of the pen in millimeters. This value is in millimeters, written in the format xx.yy (for
example 2.5 indicates that lines will be drawn with a thickness of 2.5 millimeters).
Style: It indicates the pen style to draw lines. You can use the following styles:
0: solid line
1: dashed line
2: dotted line
3: dash-dot line
4: line dash-dot-dot
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 164
The state of the art for the modern dentists
Command PutCenteredImage
Utilization Creation and execution of the script
Parameters ImageIndex: It indicates the image number. It must be always “0”.
Left: It indicates the position in millimeters on the left of the box that includes the
image
Top: It indicates the position in millimeters on the top of the box that includes the
image
Right: It indicates the position in millimeters on the right of the box that includes the
image
Bottom: It indicates the position in millimeters on the bottom of the box that includes the
image
Zoom: It indicates the magnification to be applied to the image
HorzRuler: It indicates whether to insert the horizontal ruler to the image
VertRuler: It indicates whether to insert the vertical ruler to the image
Example PutCenteredImage (0, 0.0, 20.0, PaperW, 150.0, 1.0, 1, 1)
Insert an image centering it in the rectangle with coordinates in millimeters: 0, 20, PaperW
(sheet width), 150. The magnification is 100% and both rulers are placed.
Description
This command inserts the image into the box indicated by the coordinates. If the image is smaller than the box
indicated, it will be centered within the box. If the image is larger than the box indicated, it will be trimmed by
centering it in the box indicated.
Parameters
ImageIndex: It indicates the image number. This number must be always “0”.
Left: It indicates the position in millimeters on the left of the box that includes the image. This value is expressed in the
format xx.yy (for example, 1.0 indicates that the box of reference is at a distance of 1.0 mm from the left edge).
Top: It indicates the position in millimeters at the top of the box that includes the image. This value is expressed in the
format xx.yy (eg 10.0 indicates that the box of reference is at a distance of 10.0 mm from the upper edge).
Right: It indicates the position in millimeters to the right of the box that includes the image.
Bottom: It indicates the position in millimeters to the bottom of the box that includes the image.
Zoom: It indicates the magnification to be applied to the image. If you don’t want to apply any enlargement, you must
indicate "1.0". A value less than "1" reduces the image, while a higher value to "1" enlarges the image. A value of -1
will adapt the image to the page size
HorizRuler: indicates if you want to enter the horizontal ruler. To enter the horizontal ruler indicate the value 1,
otherwise enter the value 0.
VertRuler: indicates if you want to enter the vertical ruler. To enter the vertical ruler indicate the value 1, otherwise
enter the value 0.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 165
The state of the art for the modern dentists
Command PutExtLogo
Utilization Creation and execution of the script
Parameters FileName: It indicates the file name where the logo is.
Left: It indicates the left position of the logo
Top: It indicates the top position of the logo
Right: It indicates the right position of the logo
Bottom: It indicates the bottom position of the logo
Example
Description
This command allows you to insert the logo of the clinic by reading it from a bitmap or jpeg files. The position of the
logo is indicated by the coordinates of the box that includes the logo. The logo will be printed at its actual size and
centered in the box indicated. If the evidence is too large, you can reduce it with a graphics program.
Parameters
FileName: It indicates the file name where the logo is (for example “C:\Loghi\ClinicLogo.bmp”).
Left: It indicates the position in millimeters on the left of the box that includes the image. This value is expressed in the
format xx.yy (for example, 1.0 indicates that the box of reference is at a distance of 1.0 mm from the left edge).
Top: It indicates the position in millimeters at the top of the box that includes the image. This value is expressed in the
format xx.yy (eg 10.0 indicates that the box of reference is at a distance of 10.0 mm from the upper edge).
Right: It indicates the position in millimeters on the right of the box that includes the image
Bottom: It indicates the position in millimeters on the bottom of the box that includes the image
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 166
The state of the art for the modern dentists
Command PutImage
Utilization Creation and execution of the script
Parameters ImageIndex: It indicates the image number. It must be always “0”.
Left: It indicates the left position of the image in millimeters
Top: It indicates the top position of the image in millimeters
Zoom: It indicates the magnification to be applied to the image
HorzRuler: It indicates whether to insert the horizontal ruler to the image
VertRuler: It indicates whether to insert the vertical ruler to the image
Example PutImage (0, 100.0, 25.0, 0.8, 1, 1)
Draw the image number "0" starting from 100 millimeters from the left edge and 25 from the
upper edge. The magnification of 80% is applied to the image (the image will be reduced) and
will be included both rulers.
Description
This command places the image in the position shown with the characteristics specified by the parameters. This
command has no control on the image size so the image may be cut off if it ends off the page. This magnification allows
you to print images in the format 1: 1.
Parameters
ImageIndex: It indicates the image number. This number must be always “0”.
Left: It indicates the position in millimeters on the left where the image is drawn. This value is expressed in the format
xx.yy (for example, 1.0 indicates that the image is drawn at a distance of 1.0 mm from the left edge).
Top: It indicates the position in millimeters on the top where the image is drawn. This value is expressed in the format
xx.yy (eg 10.0 it indicates that the image is drawn at a distance of 10.0 mm from the upper edge).
Zoom: It indicates the magnification to be applied to the image. If you don’t want to apply any enlargement, you must
indicate "1.0". A value less than "1" reduces the image, while a higher value to "1" enlarges the image. A value of -1
will adapt the image to the page size
HorizRuler: indicates if you want to enter the horizontal ruler. To enter the horizontal ruler indicate the value 1,
otherwise enter the value 0.
VertRuler: indicates if you want to enter the vertical ruler. To enter the vertical ruler indicate the value 1, otherwise
enter the value 0.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 167
The state of the art for the modern dentists
Command PutLogo
Utilization Creation and execution of the script
Parameters FileName: It indicates the file name where the logo is.
Left: It indicates the left position of the logo
Top: It indicates the top position of the logo
Example PutLogo (“C:\Loghi\ClinicLogo.bmp”, 2.0, 2.0)
Read the image contained in the file "C:\ Logos\ClinicLogo.bmp" and inserts it in the position 2
mm from the left edge and 2 mm from the top edge
Description
This command allows you to insert the logo of the clinic by reading it from a bitmap or jpeg files. The position of the
logo is indicated by the coordinates. The logo will be printed at its actual size. If it is too large, you can reduce it with a
graphics program.
Parameters
FileName: It indicates the file name where the logo is (for example “C:\Loghi\ClinicLogo.bmp”).
Left: It indicates the position in millimeters on the left where to draw the logo. This value is expressed in the format
xx.yy (for example, 1.0 indicates that the image is drawn at a distance of 1.0 mm from the left edge).
Top: It indicates the position in millimeters on the top where to draw the logo. This value is expressed in the format
xx.yy (eg 10.0 it indicates that the image is drawn at a distance of 10.0 mm from the upper edge).
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 168
The state of the art for the modern dentists
Command TextCentered
Utilization Creation and execution of the script
Parameters Left: It indicates the position in millimeters on the left of the box that includes the text
Top: It indicates the position in millimeters on the top of the box that includes the text
Right: It indicates the position in millimeters on the right of the box that includes the text
Bottom: It indicates the position in millimeters on the bottom of the box that includes the text
Text: It indicates what you want to write
Centered: It indicates if you want to center the text
Example TextCentered (0.0, 100.0, PaperW, 110.0, "Patient: <Patient>", 1)
Write the text, centering it, 0 millimeters from the left edge and 100 millimeters from the top
edge, ending at the right edge of the sheet and at 110 millimeters from the bottom. The written
text has a fixed part “Patient:” and a variable one “<Patient>”. This part will be replaced with
patient name and last name.
Description
This command writes a text, using the font style selected with the command "Font", within a rectangle. The reference
rectangle is not drawn but it serves only as a reference to the text placement. This command controls the final size of the
text and is able to wrap to a new line if the text exceeds the size of the paper. You can use this command to write lyrics
that do not change or texts with references to patient data (fields).
Parameters
Left: It indicates the position in millimeters of the leftmost point of the box that includes the text. This value is
expressed in the format xx.yy (for example, 1.2 indicates that the box will be calculated at a distance of 1.2 mm from
the left edge).
Top: It indicates the position in millimeters of the highest point of the box that includes the text. This value is expressed
in the format xx.yy (for example 12:50 indicates that the box will be calculated at a distance of 12.50 mm from the
upper edge).
Right: It indicates the position in millimeters of the rightmost point of the box that includes the text. This value is
expressed in the format xx.yy (for example 100.0 indicates that the box will be calculated at a distance of 100.0 mm
from the left edge).
Bottom: It indicates the position in millimeters of the lowest point of the box that includes the text. This value is
expressed in the format xx.yy (for example 200.0 indicates that the box will be calculated at a distance of 200.0 mm
from the upper edge).
Text: It indicates what you want to write. The text must be enclosed in double quotes and can include FIELDS.
Centered: It indicates if you want to center the text within the box indicated. To center the text, enter the value 1,
otherwise enter the value 0.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 169
The state of the art for the modern dentists
Command TextOut
Utilization Creation and execution of the script
Parameters Left: It indicates the position on the left of the text in millimeters
Top: It indicates the position on the top of the text in millimeters
Text: It indicates what you want to write
Example TextOut (5.0, 5.0, "Patient: <Patient>")
It writes the text starting at 5 mm from the left edge and at 5 mm from the top edge. The written
text has a fixed part “Patient:” and a variable one “<Patient>”. This part will be replaced with
patient name and last name.
Description
This command writes a text using the font style selected with the command "Font". This command does not control the
final size of the text and it is not able to wrap to a new line if the text exceeds the size of the paper. You can use this
command to write lyrics that do not change or texts with references to patient data (fields).
Parameters
Left: It indicates the position in millimeters of the left point where to start writing. This value is expressed in
millimeters in size xx.yy (eg 10.5 indicates that the text will be written from 10.5 mm from the left edge of the paper).
Top: It indicates the position in millimeters of the left point where to start writing.It indicates the position in
millimeters of the top point where to start writing. This value is expressed in millimeters in size xx.yy (eg 50.0 indicates
that the text will be written from 50.0 millimeters from the top edge of the sheet).
Text: It indicates what you want to write. The text must be enclosed in double quotes and can include FIELDS.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 170
The state of the art for the modern dentists
EXAMPLE
In the following picture, you can see the graphic result of the commands written above.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org
Dental Studio Plus®
Pag. 171
The state of the art for the modern dentists
The image used for the preparation of the preview sample is always the image shown in FIG. The result obtained from
the preview may be different due to the different size of the image.
© Copyright DIGITAL imaging sas – Via Alfieri 12 A B – 10142 Nichelino (TO) First edition: November 2006
www.digitalimaging.it Revision: September 2017
www.archimed.org