This quick reference guide provides an overview of the key buttons and main menu structure of the Delcos 1000 air compressor controller. The main selection menu can be accessed by pressing and holding the up and down buttons for 5 seconds and entering an access code. The main menu includes options to view operating times, maintenance requirements, operating mode settings, and factory pre-settings. Selections and values in the menus can be scrolled through and edited using the directional buttons and enter key.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
100% found this document useful (3 votes)
2K views2 pages

DL067AA - Delcos 1000

This quick reference guide provides an overview of the key buttons and main menu structure of the Delcos 1000 air compressor controller. The main selection menu can be accessed by pressing and holding the up and down buttons for 5 seconds and entering an access code. The main menu includes options to view operating times, maintenance requirements, operating mode settings, and factory pre-settings. Selections and values in the menus can be scrolled through and edited using the directional buttons and enter key.
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Quick Reference Guide

Delcos 1000

SM 1345

Key to Buttons Access Code


From "Press. & Temp." display:

START Press and hold & buttons


for 5 seconds

Enter Code:
STOP

Main Selection Menu


RESET: Resets Faults/Warnings
Mains Pressure: Network Pressure and
Pressure Settings

UP: Scrolls Up in Menu Routines Note: Not accessible on


pressure switch-controlled
models (L04 & L05)

Operating Times: Running and Loaded Hours


DOWN: Scrolls Down in Menu Routines
Maintenance: Service Times

Operating Mode: Operating Settings


MINUS: Scrolls Left/Decreases Values
Factory Pre-setting: Default Values

RIGHT: Scrolls Right/Increases Values

ENTER: Selects/Confirms Values See overleaf for details

DL067AA CompAir Drucklufttechnik GmbH, Argenthaler Straße 11, D-55469, Simmern/Hunsrück, Germany. 04/2007
Tel: +49 6761 8320 Fax:+49 6761 832409 Email: [email protected]
Training Enquiries: [email protected]
Delcos 1000 - Main Menu Structure (Examples Only)
Operating times Change of settings
if the settings are to be changed, select the corresponding menu point and press the key.
The setting value will flash and can now be changed with the or keys. This does not
Load hours apply to factory pre-settings, with the exception of the (Starts per hour) settings.
(see "Change coasting time" within the user manual).

Operating hours * Hold down for 5 seconds

Mains pressure Press. & Temp. display Maintenance Operating mode Factory pre-settings

Mains pressure display Remaining time air filter Operating mode Operating pressure
* Aut = Automatic operation
&
cnt = Continuous operation
Fault storage
Startup protection
Pressure band 1, cut-out pressure Remaining time oil filter
Local/remote control
Loc = Local control
Etn = Remote control Shutdown excess. comp. temp.

Pressure band 1, cut-in pressure Remaining time fine separator

Early warning excess. comp. temp.


Automatic re-start

Pressure band 2, cut-out pressure Remaining time oil change


Start-up blockage low temp.
Start delay for deferred startup(s)

Pressure band 2, cut-in pressure Shutdown at - 100 hours


Star/delta changeover time
Limited power failure time
The menu point for the additional
Fault message indicated automatic restart after power failure
(Er1 = latest entry) (PFt) is only displayed if this Max. number of starts per hour
function has been activated. See
The error codes in the right display chapter "additional automatic
Pressure band 2 can be configured can be found in the fault storage restart after power failure" within
via terminal block X2 table (see user manual). the user manual. Soft-stop time
SM 1346
Accessible and Visible on code entry only
Compressor number
Access Code
From Press. & Temp. display :-
Press and hold & buttons for 5 seconds
(display changes to: ) Protocol
Enter code: