96M13020 Precautions on Proper Use

• Do not use a voltage other than that described in the specifications with
the SR-1000 Series. Doing so may cause damage to the unit.
• Be sure to turn off the power to devices attached to the SR-1000 Series
Autofocus Code Reader (Fixed Type) when you plug in or unplug the cables. Failure to do so may cause damage
to the SR-1000 Series.

SR-1000 Series • Do not disassemble or modify the SR-1000 Series. Doing so may cause
damage to the unit.
• Place cables as far away as possible from high-voltage lines and power

Instruction manual
lines. Otherwise, electrical noise can be generated that may cause a
product failure or malfunction.
NOTICE
• The SR-1000 Series is a precision instrument. Do not impact or drop the
instrument. Pay particular attention when transporting or installing the unit.
• Do not carry the SR-1000 Series by holding its cables. This may cause cable
breaks or damage to the unit due to the impact of bumping each other.
Introduction • Do not allow water, oil, dust, or other foreign substances to stick to the
scanner. This may cause read errors. Use a soft, dry cloth to wipe any
Read this instruction manual before using the product in order to achieve substance from the scanner. (Do not use a cloth dipped in alcohol or other
cleaning agent.)
maximum performance. • Do not turn off the power of the SR-1000 Series while accessing files. The
After reading it, keep the manual always at hand for future reference. internal data may be corrupted.

„ Symbols
The following symbols alert you to important messages. Be sure to read Precautions on Proper Use
these messages carefully.
„ CE Marking
It indicates a hazardous situation which, if not avoided, will result in death or
DANGER
serious injury. Keyence Corporation has confirmed that this product complies with the
It indicates a hazardous situation which, if not avoided, could result in death essential requirements of the applicable EC Directive, based on the
WARNING
or serious injury. following specifications.
CAUTION
It indicates a hazardous situation which, if not avoided, could result in minor Be sure to consider the following specifications when using this product
or moderate injury. in the Member State of European Union.
It indicates a situation which, if not avoided, could result in product damage
NOTICE
as well as property damage. z EMC Directive (2004/108/EC)
• Applicable standards EMI : EN61326-1, Class A
Important It indicates cautions and limitations that must be followed during operation. EMS : EN61326-1
• The length of cable connected to the power supply connector must
Point It indicates additional information on proper operation.
be less than or equal to 30 m.
• This product is intended to be used in an industrial electromagnetic
Reference It indicates tips for better understanding or useful information. environment.
These specifications do not give any guarantee that the end-product with
Indicates the reference pages in this manual or the reference pages in separate manuals.
this product incorporated complies with the essential requirements of
Safety Information for SR-1000 Series EMC Directive. The manufacturer of the end-product is solely responsible
for the compliance on the end-product itself according to EMC Directive.
„ General Precautions
z Low-Voltage Directive (2006/95/EC)
• Do not use this product for the purpose to protect a human body or a part
of human body. • Applicable standard : EN62471
• This product is not intended for use as explosion-proof product. Do not
WARNING
use this product in hazardous location and/or potentially explosion
• Indoor use only.
atmosphere.
• You must verify that the SR-1000 Series are operating correctly in terms of
„ CSA Certificate
functionality and performance before the start and the operation of the This product complies with the following CSA and UL standards and has
CAUTION SR-1000 Series.
• We recommend that you take substantial safety measures to avoid any been certified by CSA.
damage in the event of a problem occurring.
• Applicable standard : CAN/CSA C22.2 No.61010-1
• KEYENCE never warrant the function or performance of the SR-1000
Series if it is used in a manner that differs from the SR-1000 Series
UL61010-1
specifications contained in this instruction manual of if the SR-1000 • Be sure to consider the following specifications when using this product
Series are modified by yourself.
NOTICE • When the SR-1000 Series is used in combination with other instruments, as a product certified by CSA.
functions and performance maybe degraded, depending on operating • Overvoltage category
conditions and the surrounding environment.
• If the equipment is used in a manner not specified by the manufacturer. • Use this product under pollution degree 2.
the protection provided by the equipment may be impaired.
• Use this product at the altitude of 2000 m or less.
• Indoor use only.
Safety Precautions on LED Product
• When using this product, use the following power supply.
CSA or UL certified power supply that provides Class 2 output as
• Use of controls or adjustments or performance of procedures other than
those specified herein may result in hazardous radiation exposure. defined in the CEC (Canadian Electrical Code) and NEC (National
• Follow the instructions mentioned in this manual. Otherwise, injury to the
human body (eyes and skin) may result. Electrical Code), Or CSA or UL certified power supply that has been
• Do not stare into the beam. evaluated as a Limited Power Source as defined in CAN/CSA-C22.2
CAUTION • Do not disassemble this product.
LED emission from this product is not automatically stopped when it is No. 60950-1/UL60950-1.
disassembled.
• Do not view directly with optical instruments. Viewing the LED output
with certain optical instruments (for example, eye loupes, magnifiers „ Radio Waves Act in South Korea
and microscopes) within a distance of 100 mm may pose an eye hazard. Class A Equipment
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Note: This caution is effective for the Korean Radio Act only.

A 급 기기 ( 업무용 방송통신기자재 )
이 기기는 업무용 (A 급 ) 전자파적합기기로서 판매자 또는 사용자는 이
점을주의하시기 바라며 , 가정외의 지역에서 사용하는 것을 목적으로 합
니다 .

1 E SR-1000-IM
Package Contents Startup Procedure

Package
Model Name Qty. Appearance
content Step 1
SR-1000/1000W Auto focus code reader Reader unit 1 SR-1000
SEL
MENU

(Fixed type)

Instruction 1 2D Code Reader (Fixed Type)


SR-1000 Series
96M13020 Precautions on Proper Use

• Do not use a voltage other than that described in the specifications with
the SR-1000 Series. Doing so may cause damage to the unit.
• Be sure to turn off the power to devices attached to the SR-1000 Series
when you plug in or unplug the cables. Failure to do so may cause damage
to the SR-1000 Series.
• Do not disassemble or modify the SR-1000 Series. Doing so may cause

manual
damage to the unit.
• Place cables as far away as possible from high-voltage lines and power
lines. Otherwise, electrical noise can be generated that may cause product
Instruction manual NOTICE
failure or malfunction.
• The SR-1000 Series is a precision instrument. Do not impact or drop the
instrument. Pay particular attention when transporting or installing the unit.
• Do not carry the SR-1000 Series by holding its cables. This may cause cable
breaks or damage to the unit due to the impact of bumping each other.
Introduction • Do not allow water, oil, dust, or other foreign substances to stick to the
scanner. This may cause read errors. Use a soft, dry cloth to wipe any
Read this instruction manual before using the product in order to achieve substance from the scanner. (Do not use a cloth dipped in alcohol or other
cleaning agent.)
maximum performance. • Do not turn off the power of the SR-1000 Series while accessing files. The
After reading it, keep the manual always at hand for future reference. internal data may be corrupted.

„ Symbols
The following symbols alert you to important messages. Be sure to read Precautions on Proper Use
these messages carefully.
„ CE Marking
It indicates a hazardous situation which, if not avoided, will result in death or
DANGER Keyence Corporation has confirmed that this product complies with the
serious injury.
It indicates a hazardous situation which, if not avoided, could result in death essential requirements of the applicable EC Directive, based on the
WARNING
or serious injury. following specifications.
CAUTION
It indicates a hazardous situation which, if not avoided, could result in minor Be sure to consider the following specifications when using this product
or moderate injury. in the Member State of European Union.
It indicates a situation which, if not avoided, could result in product damage
NOTICE
as well as property damage. z EMC Directive (2004/108/EC)
• Applicable standards EMI : EN61326-1, Class A
Important It indicates cautions and limitations that must be followed during operation. EMS : EN61326-1
• The length of cable connected to the power supply connector must
Point It indicates additional information on proper operation.
be less than or equal to 30 m.
These specifications do not give any guarantee that the end-product
Reference It indicates tips for better understanding or useful information. with this product incorporated complies with the essential
requirements of EMC Directive. The manufacturer of the end-product
Indicates the reference pages in this manual or the reference pages in separate manuals.
is solely responsible for the compliance on the end-product itself
Safety Information for SR-1000 Series according to EMC Directive.
z Low-Voltage Directive (2006/95/EC)
„ General Precautions
• Applicable standard : EN62471
• Do not use this product for the purpose to protect a human body or a part
of human body. • Indoor use only.
WARNING • This product is not intended for use as explosion-proof product. Do not
use this product in hazardous location and/or potentially explosion
atmosphere. „ CSA Certificate
• You must verify that the SR-1000 Series are operating correctly in terms of This product complies with the following CSA and UL standards and has
functionality and performance before the start and the operation of the been certified by CSA.
CAUTION SR-1000 Series.
• We recommend that you take substantial safety measures to avoid any • Applicable standard : CAN/CSA C22.2 No.61010-1
damage in the event of a problem occurring.
UL61010-1
• KEYENCE never warrant the function or performance of the SR-1000
Series if it is used in a manner that differs from the SR-1000 Series
• Be sure to consider the following specifications when using this product
specifications contained in this instruction manual of if the SR-1000 as a product certified by CSA.
NOTICE Series are modified by yourself.
• When the SR-1000 Series is used in combination with other instruments, • Overvoltage category
functions and performance maybe degraded, depending on operating • Use this product under pollution degree 2.
conditions and the surrounding environment.
• Use this product at the altitude of 2000 m or less.
Safety Precautions on LED Product • Indoor use only.
• When using this product, use the following power supply.
• Use of controls or adjustments or performance of procedures other than CSA or UL certified power supply that provides Class 2 output as
those specified herein may result in hazardous radiation exposure. defined in the CEC (Canadian Electrical Code) and NEC (National
• Follow the instructions mentioned in this manual. Otherwise, injury to the
human body (eyes and skin) may result. Electrical Code), Or CSA or UL certified power supply that has been
• Do not stare into the beam.
CAUTION • Do not disassemble this product. evaluated as a Limited Power Source as defined in CAN/CSA-C22.2
LED emission from this product is not automatically stopped when it is No. 60950-1/UL60950-1.
disassembled.
• Do not view directly with optical instruments. Viewing the LED output
with certain optical instruments (for example, eye loupes, magnifiers „ Radio Waves Act in South Korea
and microscopes) within a distance of 100 mm may pose an eye hazard.
Class A Equipment
This is a class A product. In a domestic environment this product may
cause radio interference in which case the user may be required to take
adequate measures.
Note: This caution is effective for the Korean Radio Act only.

Ͳ 匏͑匶匶͙͑ 櫋怺殯͑愯暧皻柦匶沖沲 ͚
決͑匶匶垚͑櫋怺殯͙͑Ͳ͑匏͚͑͑洊沖砒洇穯匶匶嵢昢͑砖廪沖͑嬖垚͑斲殯沖垚͑決
洖汊渂汞穞柢匶͑愚岂彶͑͑͝儆洛歾汞͑滆櫳櫖昢͑斲殯穞垚͑冉汊͑徯洇求嵢͑穯
城埪͑͟

1 E SR-1000-IM

POWER

Ethernet port 1
cover

Step 2
Option DC24V
Brown
Package
Model Name Qty. Appearance
content
Blue
SR-H4W Setup software DVD-ROM 1
(AutoID Network
Navigator)
Black tube
FG
OP-87224/ Control cable Cable 1
87225/87226 (2 m/5 m/10 m)

OP-87353/87354/ Control cable Cable 1 Step 3


87355 (NFPA-compliant) (2 m/5 m/10 m)

OP-87527/87528/ Control cable Cable 1


87529 (NFPA-compliant) (2 m/5 m/10 m)
D-sub connector type

OP-87230/87231/ Ethernet cable Cable 1


87232 (NFPA-compliant) (2 m/5 m/10 m)

OP-51580 USB cable Cable 1


(2 m)

Step 4
OP-87866 Mounting bracket Mounting 1
bracket

Screw (M4) 4

Part Names and Functions

Top
SEL

SR-10 00
MENU
Step 5
(2)
(3)
(1) SR-1000
(4)
(5)
(6)
Bottom
(7)
POWER
TEST MODE
ETHERNET
(8)
USB

No. Name Description Sample Code


(1) Scanner Section that reads codes.
(2) Display Shows reading results or reading data. DataMatrix CODE128
(3) OK/ERROR LED IIndicates whether the reading has succeeded or failed
(4) ENTER button Button used to confirm functions.
(5) SELECT button Button used to select functions.
(6) Control port Port for connecting the control cable.
(7) Ethernet port Port for connecting the Ethernet cable.
(8) USB port Port for connecting the USB cable for setting.
1 2 3 4 5

E SR-1000-IM 2
Connection and Wiring Wire color Name Description
Signal
Initial assignment AWG
direction
„ Connecting the control cable and wiring Brown 24 V 24 VDC Input - 26

1 Align the protrusion in the cable connector with the notch in the Blue 0V Power GND - - 26

control port. Orange RXD (RD) RS-232C Receive Input - 28


Yellow TXD (SD) RS-232C Send Output - 28
Purple SGND RS-232C GND - - 28
Green IN1 Input signal 1 Input Reading start 26
Gray IN2 Input signal 2 Input - 28
White and
IN COM Input common - - 28
blue
Pink OUT1 Output signal 1 Output Reading OK 28
Light blue OUT2 Output signal 2 Output Reading ERROR 28

2 Tighten the connector screw by turning it clockwise.


White OUT3 Output signal 3 Output BUSY 28
Black OUT COM Output common - - 28
Black tube FG Frame ground - - -

• Be sure to turn power off before attempting to connect or disconnect the


control cable.
Screw tightening torque: • Insert the connector straight so that it is not tilted and then tighten it
1.5 to 2.0 N·m securely. Under-tightening can lead to a loose connector due to
vibrations, resulting in poor contact.
* After tightening it as much as possible by hand, tighten it further
NOTICE
approximately 90° - 120° using a tool such as pliers.
• Insulate unused wires individually.
• Be sure to provide Class D ground for the FG wire.
• The shield and FG wires of the control cable and the shield wire of the
Ethernet cable are electrically connected via the main unit housing. Be
sure to provide them with a common ground.
3 Connect the wires according to the usage.
z When the I/O terminals are not used „ Connecting the Ethernet cable
1 Align the protrusion in the cable connector with the notch in the
Ethernet port and connect the cable to the main unit.
SEL
MENU

SR-1000

Brown 24 V
24 VDC

Blue 0V

Black tube FG

z NPN wiring

Brown 24 V
2 Tighten the connector screw by turning it clockwise.
SEL

SR-1000
MENU

The screw tightening torque should be within the range between 0.8 and
Load 1.0 N·m.
Pink/ OUT1 to 3
Light blue/White

White and blue IN COM


24 VDC

Screw tightening torque:


Green/Gray IN1 to 2
0.8 to 1.0 N·m

Black OUT COM

Blue 0V

• When connecting the connector, insert it so that it does not tilt, and then
Black tube FG
push in and tighten the connector securely. Under-tightening can lead to a
loose connector due to vibrations, resulting in poor contact.
z PNP wiring NOTICE • After tightening it as much as possible by hand, tighten it further
approximately 5° - 10° using a tool such as pliers.
• Do not bend the base of the Ethernet cable connector repeatedly. It may
SEL
MENU
Brown 24 V cause connection failure.
SR-1000

Black OUT COM


„ Connecting the USB cable
1 Confirm the orientation and insert the connector straight so that it is
Green/Gray IN1 to 2 not tilted.
24 VDC

White and blue IN COM

Load ETHERNET
POWER

Pink/ OUT1 to 3 USB

Light blue/White

Blue 0V

Black tube FG

When connecting the connector, insert it straight so it does not tilt.


NOTICE
Otherwise, the connector pin may be damaged.

3 E SR-1000-IM
View and Installation Distance Minimum Resolution (Typical)
The SR-1000 Series provides different installation distances to the target and
• SR-1000 Unit: mm • SR-1000W Unit: mm
view sizes depending on the type of the reader. Confirm the type of the
Distance 2D code Barcode Distance 2D code Barcode
reader to be used and its view.
110 0.063 - 50 0.082 -
110 to 140 0.082 - 50 to 100 0.14 0.082
View H
110 to 230 0.14 0.082 50 to 150 0.20 0.12
110 to 300 0.18 0.11 50 to 230 0.30 0.18
110 to 400 0.24 0.15 50 to 300 0.38 0.23
110 to 600 0.37 0.22 50 to 400 0.51 0.31
View V 110 to 1000 0.61 0.37 50 to 600 0.76 0.45
0
00
-1
R
S
U
EN
M

L
E
S

Mounting
Installation distance
1 Secure the SR-1000 Series unit with screws.
• 1280 × 1024 (pixels) Mounting screws are not included.
View V = View H × 0.80 (H:V = 5:4)
• 800 × 600 (pixels)

S
R
-1
View V = View H × 0.75 (H:V = 4:3)

00
0

S
E
L
M
EN
U
„ SR-1000 (Standard type)

View H (mm)
350

300

250

200

150 • Mounting screw size : M4


• Tightening torque : 0.5N·m
100 • Screw hole depth of the SR-1000 Series : 5 mm
1280x1024
50
800x600
0 Mounting by Using the Optional Mounting Bracket (OP-87866)
0 100 200 300 400 500 600 700 800 900 1000 1100
Distance (mm)
1 Attach the optional mounting bracket to the SR-1000 Series.

Typical Unit: mm
1280 x 1024 (pixel) 800 x 600 (pixel)
Distance
Horizontal Vertical Horizontal Vertical
110 30 24 19 14
1000 312 250 195 146
Mounting bracket

„ SR-1000W (Wide-view type)

View H (mm)
700

600
SE
L

500
ME
NU

SR
-100
0

400
• Mounting bracket : M4
300
• Supplied screw size : 0.5N·m
200
2 Secure the mounting bracket.
1280x1024
100 Mounting screws are not included.
800x600
0
0 100 200 300 400 500 600 700 800 900 1000 1100
Distance (mm)
Typical Unit: mm
1280 x 1024 (pixel) 800 x 600 (pixel)
Distance
Horizontal Vertical Horizontal Vertical SE
L

ME
NU

50 35 28 22 16 SR
-100
0

600 384 307 240 180

• Mounting screw size : M5


The distances or angles that can be used for reading may vary according to
the print quality and size of the code to be read or surrounding environment.
NOTICE
Use the test mode, etc. to confirm the most appropriate mounting condition
in the environment.

E SR-1000-IM 4
Specifications

Model SR-1000 SR-1000W


Type Standard Wide range
Sensor CMOS Image Sensor
Receiver
Number of pixels 1280 x 1024 pixels
Light source High-intensity red LED
Light emitter
Pointer light source High-intensity green LED
Focus adjustment Automatic*
QR, MicroQR, DataMatrix (ECC200), GS1 DataMatrix
2D code
PDF417, Micro PDF417, GS1 Composite (CC-A, CC-B, CC-C)
Supported symbol
GS1 DataBar, CODE39, CODE39 FullASCII, Trioptic CODE39, CODE93, CODE128, GS1-128,
Barcode
JAN/EAN/UPC, ITF, NW-7 (Codabar), 2of5 (Industrial 2of5), COOP 2of5, Pharmacode
Reading specifications 2D code 0.063 mm 0.082 mm
Minimum resolution
Barcode 0.082 mm 0.082 mm
Reading distance 110 mm to 1000 mm 50 mm to 600 mm
Reading view range (at a distance of 400 mm) 122 mm x 97 mm 257 mm x 206 mm
Points 2
Input type Bidirectional voltage input
Control input Maximum rating 26.4 VDC
Minimum ON voltage 15 VDC
Maximum OFF current 0.2 mA or less
Points 3
Output type Photo MOS relay output
Maximum rating 30 VDC
Control output
I/O specifications Maximum load current 1 output: 50 mA or less, 3-output total: 100 mA or less
Leakage current when OFF 0.1 mA or less
Residual voltage when ON 1 V or less
Communication standard IEEE 802.3 compliant, 10BASE-T/100BASE-TX
Ethernet
Supported protocol TCP/IP, SNTP, FTP, BOOTP, EtherNet/IP, PROFINET, KV STUDIO, MC Protocol, OMRON PLC Link
Communication standard RS-232C compliant
Serial communication Communication speed 9600, 19200, 38400, 57600, 115200 bps
Supported protocol None, KV STUDIO, MC Protocol, SYSWAY
USB Communication standard USB 2.0 Full Speed compliant
Enclosure rating IP65
Ambient temperature 0 to 45°C
Ambient storage temperature -10 to +50°C
Relative humidity 35 to 85% RH (No condensation)
Environmental resistance
Storage ambient humidity 35 to 85% RH (No condensation)
Ambient light Sunlight: 10000 lux, Incandescent lamp: 6000 lux, Fluorescent lamp: 2000 lux
Operating environment No dust or corrosive gas present
Vibration 10 to 55 Hz Double amplitude 0.75 mm, 3 hours each in X, Y and Z directions
Power supply voltage 24 VDC±10%
Rating
Current consumption 700 mA
Weight Approx. 200 g

*The focus position can be automatically adjusted during installation and during tuning.

5 E SR-1000-IM
Dimensions WARRANTIES AND DISCLAIMERS
„ SR-1000/1000W (1) KEYENCE warrants the Products to be free of defects in materials and workmanship
for a period of one (1) year from the date of shipment. If any models or samples were
4×M4
Depth: 5
shown to Buyer, such models or samples were used merely to illustrate the general
47
38.5 2.6
28
type and quality of the Products and not to represent that the Products would
necessarily conform to said models or samples. Any Products found to be defective
17
20.5 must be shipped to KEYENCE with all shipping costs paid by Buyer or offered to
28 KEYENCE for inspection and examination. Upon examination by KEYENCE,
74
KEYENCE, at its sole option, will refund the purchase price of, or repair or replace at
no charge any Products found to be defective. This warranty does not apply to any
123 120 123 120 defects resulting from any action of Buyer, including but not limited to improper
152 installation, improper interfacing, improper repair, unauthorized modification,
180 misapplication and mishandling, such as exposure to excessive current, heat,
coldness, moisture, vibration or outdoors air. Components which wear are not
warranted.
(2) KEYENCE is pleased to offer suggestions on the use of its various Products. They are
only suggestions, and it is Buyer's responsibility to ascertain the fitness of the
Products for Buyer’s intended use. KEYENCE will not be responsible for any
18.9 damages that may result from the use of the Products.
47.6 (3) The Products and any samples ("Products/Samples") supplied to Buyer are not to be
used internally in humans, for human transportation, as safety devices or fail-safe
Unit: mm
systems, unless their written specifications state otherwise. Should any Products/
Samples be used in such a manner or misused in any way, KEYENCE assumes no
responsibility, and additionally Buyer will indemnify KEYENCE and hold KEYENCE
„ When the mounting bracket (OP-87866) is used harmless from any liability or damage whatsoever arising out of any misuse of the
Products/Samples.
52 (4) OTHER THAN AS STATED HEREIN, THE PRODUCTS/SAMPLES ARE PROVIDED
50.5 33 WITH NO OTHER WARRANTIES WHATSOEVER. ALL EXPRESS, IMPLIED, AND
28 10°
10° STATUTORY WARRANTIES, INCLUDING, WITHOUT LIMITATION, THE
5.3 WARRANTIES OF MERCHANTABILITY, FITNESS FOR A PARTICULAR
PURPOSE, AND NON-INFRINGEMENT OF PROPRIETARY RIGHTS, ARE
28 47
R32 EXPRESSLY DISCLAIMED.
7.5 IN NO EVENT SHALL KEYENCE AND ITS AFFILIATED ENTITIES BE LIABLE TO
φ5.3 ANY PERSON OR ENTITY FOR ANY DIRECT, INDIRECT, INCIDENTAL,
PUNITIVE, SPECIAL OR CONSEQUENTIAL DAMAGES (INCLUDING, WITHOUT
2
LIMITATION, ANY DAMAGES RESULTING FROM LOSS OF USE, BUSINESS
(5)
INTERRUPTION, LOSS OF INFORMATION, LOSS OR INACCURACY OF DATA,
LOSS OF PROFITS, LOSS OF SAVINGS, THE COST OF PROCUREMENT OF
SUBSTITUTED GOODS, SERVICES OR TECHNOLOGIES, OR FOR ANY MATTER
Unit: mm ARISING OUT OF OR IN CONNECTION WITH THE USE OR INABILITY TO USE
THE PRODUCTS, EVEN IF KEYENCE OR ONE OF ITS AFFILIATED ENTITIES
WAS ADVISED OF A POSSIBLE THIRD PARTY’S CLAIM FOR DAMAGES OR
ANY OTHER CLAIM AGAINST BUYER. In some jurisdictions, some of the foregoing
„ OP-87224/87225/87226/87353/87354/87355 warranty disclaimers or damage limitations may not apply.

2000 BUYER'S TRANSFER OBLIGATIONS:


5000 If the Products/Samples purchased by Buyer are to be resold or delivered to a third
10000 45
party, Buyer must provide such third party with a copy of this document, all
specifications, manuals, catalogs, leaflets and written information provided to Buyer
pertaining to the Products/Samples.
φ15

5 120 E 1101-3
φ6.7

5 150
5 180 Unit: mm
Cautions
„ OP-87527/87528/87529 (1) Unauthorized reproduction of this manual in whole or part is prohibited.
(2) The contents of this manual may be changed for improvements without
2000 prior notice.
5000
38 10000 45 (3) An utmost effort has been made to ensure the contents of this manual are
180
as complete as possible. If there are any mistakes or questions, please
150
contact a KEYENCE office listed in the back of the manual.
26
120
(4) Regardless of item (3), KEYENCE will not be liable for any effect resulting
from the use of this unit.
(5) Any manuals with missing pages or other paging faults will be replaced.
φ15
36.8

φ6.7

Thickness: 16 180 mm Brown, blue, black tube


150 mm Black, pink, light blue, white
120 mm Gray, green, white and blue

Unit: mm

„ OP-87230/87231/87232
φ6.5
14.7

φ15

2000
5000
51.3 10000±50 47

Unit: mm

Copyright (c) 2014 KEYENCE CORPORATION. All rights reserved.


13020E 1025-2 96M13020 Printed in Japan

You might also like