technical hotline +44 (0)1268 563720 ingress protected IP66 | wiring devices
Technical specification
Electrical
Voltage rating:
250V a.c.
Current rating:
13A per socket outlet Description
Terminal capacity: A range of socket outlets specifically designed if cable or conduit enters the enclosure from the
Live, neutral & earth for use outdoors or in areas heavily exposed to rear.
3 x 2.5mm2 dust and/or splashing water. Constructed from
3 x 4mm2 IP66 Protection
2 x 6mm2 (standard)
extremely robust poly carbonate, the range is
sealed to IP66 against dust, water and is impact Each digit in the IP (Ingress Protection) rating
Physical denotes resistance to dust and water. The
resistant and will completely protect virtually
Ambient operating temperature: any 13 amp plug* including moulded plugs, Masterseal Plus IP66 rating breakdown is as
0°C to +40°C allowing safe connection to any appliance. follows:
IP rating: *When in doubt, please use an MK 13A plug or IP66
IP66
Duraplug. Ingress Solid protection: Liquid Protection:
Max. installation altitude: protection Dust tight Powerful jets of
2000 metres Boxes No ingress of water against the
dust, complete enclosure from
Rear entry back boxes are supplied for surface protection against any direction shall
mounted situations or flush mounting when used contact have no harmful
with Flush Mounting Bezels (K56502, 1 gang / effects
K56503, 2 gang). These boxes must also be used
Features
l IP66 protected to BS EN60529: 1992 l 3 pin operated safety shutter on socket
l
outlets
Ideal for gardens, workshops, industry,
commercial, public areas, farm buildings, l 3mm minimum switch contact gap
ponds, pools etc l Additional electrical safety from neutral
l Easy to install: fixed gasket, captive backed ‘make first, break last’ feature
out terminal screws, clearly marked top l Moulded ‘on’ indicator flash on switches
access angled terminals, push fit knockouts
will not rub off
and conduit entries, rear drill holes
l Printed terminal markings on grey rear
l Patented gel seal provides durable water
mouldings for clearer identification
and dust tight seal for improved protection
l Double pole switching
l Sealed when in use with virtually any
standard 13 AMP plug, including those l Switch contacts with silver contacts on
with moulded plug tops both surface for good continuity
l Improved catch eases opening and closing l Products are available in grey, black and
during use white
l Manufactured from recycled polycarbonate
for impact protection and environmental
protection
624 Masterseal Plus™ Technical
wiring devices | ingress protected IP66www.mkelectric.co.uk
117 89 165
165
116
160
K56502
73
177 89
225
116
165
160
K56503
Depth of hole
125
1 Gang Switches
should be 40mm
4.5
15
36.5
185
36.5
15
4.5
125
2 Gang Products
4.5
15
36.5
Masterseal Plus™ Technical 625
technical hotline +44 (0)1268 563720 ingress protected IP66 | wiring devices
Technical specification
Electrical
l Override button to switch the load ON/ Dimensions (mm) Flush Mounting Bezel
OFF directly, bypassing the timer 89
177
225
l Patented gel seal provides durable
water and dust tight seal for improved
protection
116
environmental protection
l 3 pin operated safety shutter on socket
2 Gang Products
125
outlets
l Products are available in grey, black and
white 15
4.5
36.5
626 Masterseal Plus™ Technical
wiring devices | ingress protected IP66www.mkelectric.co.uk
Sentrysocket
Compliance with EC Directives,
Standards and approvals
All Sentrysockets comply with the following EC Directives and
are CE marked:
Low Voltage Directive Electromagnetic Compatibility Directive
(89/336/EEC)
Features
160
71.00
Masterseal Plus™ Technical 627
technical hotline +44 (0)1268 563720 ingress protected IP66 | wiring devices
Technical specification
Electrical
Voltage rating:
250V a.c.
Current rating:
16A
Terminal capacity:
Live, neutral & earth
4 x 1.5mm2
2 x 2.5mm2 Masterseal 16A 2P + E German socket outlet is suitable for surface mounting only.
1 x 4mm2
Physical
Dimensions (mm)
Ambient operating temperature:
0°C to +40°C
(not to exceed an average of more than 25°C in any
24 hour period) 117 89
IP rating:
IP66
160
IP66
Ingress Solid protection: Liquid Protection:
protection Dust tight Powerful jets of
No ingress of water against the
dust, complete enclosure from
protection against any direction shall
contact have no harmful
effects 73
Connection Units
Standards and approvals
All Masterseal Plus Connection Units comply with BS 1363 Part 4:
1995. All units are fitted with a 13A fuse link to BS 1362.
Technical specification
Electrical
Voltage rating:
250V a.c.
Current rating:
Connection units – 13 amp
Terminal capacity:
Impact Resistance
Features IP66
Ingress Solid protection: Liquid Protection:
l IP66 protected to BS EN60529: 1992 protection Dust tight Powerful jets of
l No ingress of water against the
Ideal for gardens, workshops, industry,
dust, complete enclosure from
commercial, public areas, farm protection against any direction shall
buildings, ponds, pools etc contact have no harmful
effects
l Easy to install: fixed gasket, captive
backed out terminal screws, clearly
marked top access angled terminals,
Dimensions (mm)
push fit knockouts and conduit entries,
rear drill holes 117 89
l Patented gel seal provides durable
water and dust tight seal for improved
protection
l Improved catch eases opening and
closing during use
116
technical hotline +44 (0)1268 563720 ingress protected IP66 | wiring devices
Switches
Standards and approvals
Switches and enclosures comply with BS EN 60669-1: 1999 and
are IP66 for BS EN 60529: 1992.
Technical specification
Electrical
Voltage rating:
250V a.c., 50 Hz
Description
Current rating:
10 or 20 amps – no derating when used on fluorescent or A range of switches and enclosures specifically Boxes
inductive loads. designed for use outdoors or in areas heavily Rear entry back boxes are supplied for surface
Load type: exposed to dust and/or splashing water. mounted situations or flush mounting when used
No resistriction Constructed from extremely robust poly with Flush Mounting Bezels (56502). These boxes
Physical carbonate, the range is sealed to IP66 against must also be used if cable or conduit enters the
dust, water and is impact resistant. Masterseal is enclosure from the rear.
Ambient operating temperature:
easy to install and the large rocker switches and
0°C to +40°C
clip in modules make it easy to use, even when
IP rating: wearing heavy gloves.
IP66
(Grid Plus enclosures are IP56) IP66 Protection*
Max. installation altitude: Each digit in the IP (Ingress Protection) rating
2000 metres denotes resistance to dust and water. The
Masterseal IP66 rating breakdown is as follows:
Features IP66
l IP66 protected to BS EN60529: 1992 Ingress Solid protection: Liquid Protection:
l
protection Dust tight Powerful jets of
Ideal for gardens, workshops, industry, No ingress of water against the
commercial, public areas, farm dust, complete enclosure from
buildings, ponds, pools etc protection against any direction shall
contact have no harmful
l Easy to install: fixed gasket, captive effects * Grid Plus enclosures are IP56
backed out terminal screws, clearly
marked top access angled terminals, Dimensions (mm) Flush Mounting Bezel
push fit knockouts and conduit entries, 95 57
95 57
rear drill holes 145
l Improved catch eases opening and
closing during use
l Manufactured from recycled
polycarbonate for impact protection and 95
95 145
environmental protection
l Large, easy to use rocker switches
56502
l Wide range of switch modules and
accessories make Masterseal versatile Fixing dimensions Flush Mounting Frame
l Switch modules snap into position 77.5
77.5 105 36.5
15
4.5
26.25
26.25
105
Conduit
52.5 1 Gang Switches Depth of hole
Entry
Centre Lines
52.5 should be 40mm
4.5
15
36.5
38.7
38.7
630 Masterseal Plus™ Technical
wiring devices | ingress protected IP56www.mkelectric.co.uk
77.5
26.25 Conduit
Entry
Centre Lines
52.5
38.7
Masterseal Plus™ Technical 631
technical hotline +44 (0)1268 563720 ingress protected IP66 | wiring devices
Technical specification
Installation tools required IDC Connectors
(telephone & RJ45 outlets)
Electrical
Cable types:
Telephone: CW1311, CW1293, CW1308, CW1316
Physical
632
MK push in conduit and cable entries that complement
ice Items.
outlets must not be mixed with other modules intended for mains supply
(110 V – 250 V 50/60 Hz).
2. This product must be installed by a competent person in accordance
ket outlets will accommodate most 13A prewired and with the current editions of the IEE Wiring Regulations (BS7671) and
plugs. Figure 1 Building Regulations.
range of products offer an ingress protection code of If in any doubt consult a qualified electrician.
uct is in or not in use. Providing the product is correctly 3. It is essential that all connections are made as instructed that cables are
Installation
m to their relevant National standard as well as the
ures BSEN60439-1, European 10/16A sockets conform
Sockets conform to BS1363: Part 2 and Connection
56462
56463
20 mm Plain Conduit Entry
20 mm Threaded conduit Entry
26.9 dia x 28
26.9 dia x 28
BURN.
6 7 8
Figure 8
13
Masterseal Plus™ Technical 633
10. Before wiring and fitting the front plate, position the seal on the front WHEN INSTALLING CONNECTION UNITS USING THE FRONT FL
plate. Ensure the holes are aligned and seal is aligned with the ribs on CABLE CLAMP
the mounting box and the cables are threaded through the seal and 1. Strip back the outer sheath on the appliance flexible LOAD cabl
screws are fully tightened. trim wires to 55mm in length. Do not trim the insulation on the t
11. Wire and fit the front plate. Ensure the seal is correctly located and the individual cables for the moment.
cables are not trapped or pinched. 2. When using cables of 10mm or more in diameter, it is necessary
WHEN INSTALLING CONNECTION UNITS USING THE Testing: stress the cable clamp before attempting to load the cable.
FRONT FLEXIBLE 3. To pre-stress the clamp insert a flat bladed screwdriver into the c
Test the completed installation in accordance with the latest grip as shown in fig. 6a and flex the clamping jaw open until it t
CABLE CLAMP the grey base moulding fig. 6b. Then remove the screwdriver.
edition of the IEE wiring regulations (BS 7671). IMPORTANT: The clamp must not be re-used for cables below 6m
diameter after pre-stressing.
1. Strip back the outer sheath on the appliance flexible LOAD Service and Maintenance: 4. Cables below 10mm diameter do not need the cable clamp pre-
cable and trim wires to 55mm in length. Do not trim the and the installation from this point is the same for all products.
insulation on the three individual cables for the moment. CLEANING 5. To assist pushing the load cable through the front of the product
the clamping jaw pressure by holding the product securely in on
2. When using cables of 10mm or more in diameter, it is 1. The exterior of the product must only be cleaned with a and pushing the tab firmly with your thumb in the direction shown in
6. Continue pushing the cable through the clamp until the outer sh
necessary to prestress the cable clamp before attempting to load solution of mild detergent (e.g. washing up liquid) and warm reaches the cable stops. See fig. 7b. The jaws must clamp on t
the cable. water. sheath.
7. Carefully strip back the insulation on all three cables to expose 1
3. To pre-stress the clamp insert a flat bladed screwdriver into CABLE SEAL CAPSULE REPLACEMENT the conductor.
8. Ensure all conductors are connected to the appropriate terminal
the cord grip as shown in fig. 6a and flex the clamping jaw open
1. Note the orientation of the cable seal capsules in the lid and Terminal screws must be securely tightened. Pull on each cable t
until it touches the grey base moulding fig. 6b. Then remove the ensure that the terminal screw has securely fixed the conductor.
front plate. Figure 5
screwdriver.
2. Carefully remove the two cable seal capsules with a flat bladed
IMPORTANT: The clamp must not be re-used for cables below
screwdriver and discard. Refer to Figure
9 8. 10
6mm diameter after pre-stressing.
3. Install the new cable seal capsules orientated as noted on
4. Cables below 10mm diameter do not need the cable clamp
removal.
pre-stressed and the installation from this point is the same for G. SPECIFICATION
all products.
All MK products are manufactured in accordance with
5. To assist pushing the load cable through the front of the ISO9001: 2008 and where applicable, comply with the EMC and/or
product, ease the clamping jaw pressure by holding the product directives 89/336/EEC and 73/23/EEC.
securely in one hand and pushing the tab firmly with your thumb Operating Temperature range –5ºC to +40ºC
in the direction shown in fig. 7a.
6. Continue pushing the cable through the clamp until the outer
sheath reaches the cable stops. See fig. 7b. The jaws must clamp
on the outer sheath.
Cable
Stops
Figure 7a Figure 7b
11 12