0% found this document useful (0 votes)
43 views4 pages

Altivar Easy 610 - ATV610D18N4

This document provides product specifications for an ATV610D18N4 variable speed drive from Schneider Electric. The key details include: - It has a power rating of 18.5 kW for normal duty and is intended for use with asynchronous motors. - Input voltage is 380-460V, 50-60Hz. It has IP20 degree of protection. - It has integrated EMC filtering, forced cooling, and modular options for communication and I/O cards. - Functions include preset speeds, acceleration/deceleration ramps, braking, and protections such as overload and short circuit.

Uploaded by

teguh perkasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
43 views4 pages

Altivar Easy 610 - ATV610D18N4

This document provides product specifications for an ATV610D18N4 variable speed drive from Schneider Electric. The key details include: - It has a power rating of 18.5 kW for normal duty and is intended for use with asynchronous motors. - Input voltage is 380-460V, 50-60Hz. It has IP20 degree of protection. - It has integrated EMC filtering, forced cooling, and modular options for communication and I/O cards. - Functions include preset speeds, acceleration/deceleration ramps, braking, and protections such as overload and short circuit.

Uploaded by

teguh perkasa
Copyright
© © All Rights Reserved
We take content rights seriously. If you suspect this is your content, claim it here.
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 4

Lembar data produk ATV610D18N4

Karakteristik variable speed drive ATV610 - 18.5 kW/25 HP -


380...415 V - IP20

Disklaimer: Dokumentasi ini tidak ditujukan sebagai pengganti dan tidak untuk digunakan untuk menentukan kesesuaian atau keandalan produk ini untuk aplikasi pengguna
Main
Range of product Easy Altivar 610
Product or component type Variable speed drive
Product specific application Fan, pump, compressor, conveyor
Device short name ATV610
Variant Standard version
Product destination Asynchronous motors
Mounting mode Cabinet mount
EMC filter Integrated conforming to EN/IEC 61800-3 category C3 with 50 m
IP degree of protection IP20
Type of cooling Forced convection
Supply frequency 50...60 Hz +/-5 %
Network number of phases 3 phases
[Us] rated supply voltage 380...460 V - 15...10 %
Motor power kW 18.5 kW for normal duty
15 kW for heavy duty
Motor power hp 25 hp for normal duty
20 hp for heavy duty
Line current 37.2 A at 380 V (normal duty)
33.5 A at 460 V (normal duty)
31.6 A at 380 V (heavy duty)
28.3 A at 460 V (heavy duty)
Prospective line Isc 22 kA
Apparent power 26.7 kVA at 460 V (normal duty)
22.6 kVA at 460 V (heavy duty)
Continuous output current 39.2 A at 4 kHz for normal duty
31.7 A at 4 kHz for heavy duty
Maximum transient current 43.1 A during 60 s (normal duty)
47.6 A during 60 s (heavy duty)
Asynchronous motor control profile Variable torque standard

16 Feb 21
1
Optimized torque mode
Constant torque standard
Output frequency 0.0001…0.5 kHz
Nominal switching frequency 4 kHz
Switching frequency 2...12 kHz adjustable
Number of preset speeds 16 preset speeds
Communication port protocol Modbus serial
Option card Slot A: communication card, Profibus DP V1
Slot A: digital or analog I/O extension card
Slot A: relay output card

Complementary
Output voltage <= power supply voltage
Motor slip compensation Can be suppressed
Automatic whatever the load
Adjustable
Not available in permanent magnet motor law
Acceleration and deceleration ramps Linear adjustable separately from 0.01 to 9000 s
S, U or customized
Braking to standstill By DC injection
Protection type Thermal protection: motor
Motor phase break: motor
Thermal protection: drive
Overheating: drive
Overcurrent between output phases and earth: drive
Overload of output voltage: drive
Short-circuit protection: drive
Motor phase break: drive
Overvoltages on the DC bus: drive
Line supply overvoltage: drive
Line supply undervoltage: drive
Line supply phase loss: drive
Overspeed: drive
Break on the control circuit: drive
Frequency resolution Display unit: 0.1 Hz
Analog input: 0.012/50 Hz
Electrical connection Control, screw terminals: 0.5...1.5 mm²
Line side, screw terminal: 10...16 mm²
Motor, screw terminal: 10...16 mm²
Connector type 1 RJ45 (on the remote graphic terminal) for Modbus serial
Physical interface 2-wire RS 485 for Modbus serial
Transmission frame RTU for Modbus serial
Transmission rate 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Type of polarization No impedance for Modbus serial
Number of addresses 1…247 for Modbus serial
Method of access Slave
Supply External supply for digital inputs: 24 V DC (19…30 V), <1.25 mA, protection type: overload and short-
circuit protection
Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection
type: overload and short-circuit protection
Local signalling 2 LEDs for local diagnostic
1 LED (yellow) for embedded communication status
2 LEDs (dual colour) for communication module status
1 LED (red) for presence of voltage
Width 211 mm
Height 495 mm
580 mm with EMC plate
Depth 232 mm
Net weight 13.3 kg
Analogue input number 3
Analogue input type AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits
AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits

2
AI2, AI3 software-configurable temperature probe or water level sensor
Discrete input number 6
Discrete input type DI1...DI6 programmable as logic input, 24 V DC (<= 30 V), impedance: 3.5 kOhm
DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V)
Input compatibility DI1...DI6: logic input level 1 PLC conforming to EN/IEC 61131-2
DI5, DI6: pulse input level 1 PLC conforming to IEC 65A-68
Discrete input logic Positive logic (source): DI1...DI6 configurable logic input, < 5 V (state 0), > 11 V (state 1)
Negative logic (sink): DI1...DI6 configurable logic input, > 16 V (state 0), < 10 V (state 1)
Positive logic (source): DI5, DI6 configurable pulse input, < 0.6 V (state 0), > 2.5 V (state 1)
Analogue output number 2
Analogue output type Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits
Sampling duration 5 ms +/- 0.1 ms (AI1, AI2, AI3) - analog input
2 ms +/- 0.5 ms (DI1...DI6)configurable - discrete input
5 ms +/- 1 ms (DI5, DI6)configurable - pulse input
10 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy +/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input
+/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input
AQ1, AQ2: +/- 0.2 % for analog output
Relay output number 3
Relay output type Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles
Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles
Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC
Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation Between power and control terminals
Insulation resistance > 1 MOhm 500 V DC for 1 minute to earth

Environment
Noise level 65 dB conforming to 86/188/EEC
Power dissipation in W 410 W(forced convection) at 380 V, switching frequency 4 kHz
64 W(natural convection) at 380 V, switching frequency 4 kHz
Volume of cooling air 215 m3/h
Operating position Vertical +/- 10 degree
Electromagnetic compatibility Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2
Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3
Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4
1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5
Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree 2 conforming to EN/IEC 61800-5-1
Vibration resistance 1.5 mm peak to peak (f= 2…13 Hz) conforming to IEC 60068-2-6
1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Shock resistance 15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity 5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation -15…45 °C (without derating)
45…60 °C (with derating factor)
Ambient air temperature for storage -40…70 °C
Operating altitude <= 1000 m without derating
1000...4800 m with current derating 1 % per 100 m
Environmental characteristic Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3
Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3
Standards EN/IEC 61800-3
Environment 2 category C3 EN/IEC 61800-3
EN/IEC 61800-5-1
IEC 60721-3
Marking CE

3
Packing Units
Package 1 Weight 14.500 kg
Package 1 Height 330.000 mm
Package 1 width 245.000 mm
Package 1 Length 730.000 mm

Offer Sustainability
Sustainable offer status Green Premium product
REACh Regulation REACh Declaration
EU RoHS Directive Pro-active compliance (Product out of EU RoHS legal scope)
EU RoHS Declaration
Mercury free Yes
RoHS exemption information Yes
China RoHS Regulation China RoHS declaration
Environmental Disclosure Product Environmental Profile
Circularity Profile End of Life Information
WEEE The product must be disposed on European Union markets following specific waste collection and
never end up in rubbish bins
Upgradeability Upgradeable through digital modules and upgraded components