0% found this document useful (0 votes)
87 views

SolarSpan Tech Data Sheet v38

The document provides technical specifications for SolarSpan roof panel systems, including panel properties, thickness options, thermal performance ratings, span tables for single and multi-span configurations, recommended uses, fire testing results, and other information.

Uploaded by

Minh Ho
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
0% found this document useful (0 votes)
87 views

SolarSpan Tech Data Sheet v38

The document provides technical specifications for SolarSpan roof panel systems, including panel properties, thickness options, thermal performance ratings, span tables for single and multi-span configurations, recommended uses, fire testing results, and other information.

Uploaded by

Minh Ho
Copyright
© © All Rights Reserved
Available Formats
Download as PDF, TXT or read online on Scribd
You are on page 1/ 2

Technical Data Sheet

EPS-FR BON0126 Bondor Tech Data Sheets. Current as of: 03/03/16

Product Description
SolarSpan® is a long-spanning commercial and residential insulated roof panel
system that combines roofing, EPS-FR insulation and a pre-painted ceiling in
one durable, functional and attractive roof panel. This all-in-one roofing solution
is manufactured using Australian-made COLORBOND® steel for durability and is
installed in a variety of applications including educational facilities, multi-residential
housing and retail facilities and is tested for use in cyclonic regions.

Panel Properties
Panel Thickness (mm) 50 75 100 125 150 200
Mass (kg/m )2
10.58 10.94 11.30 11.64 11.98 12.65
Thermal Performance at 8°C Core EPS-FR
‘R’ Value (m2K/W) 1.60 2.30 2.90 3.60 4.20 5.50 (Expanded Polystyrene with fire retardant)
Thermal Performance at 20°C Width (cover mm) 1000
‘R’ Value (m2K/W) 1.60 2.20 2.80 3.50 4.10 5.30 Thickness (mm) 50, 75, 100, 125, 150, 200
Length Up to 24m (check for availability)
Span Table
Exterior Facing Skin 0.42mm G550 Zincalume™
NON-CYCLONIC REGION A&B (ROOF APPLICATIONS ONLY) or COLORBOND® steel
SL Grade EPS-FR Core / 0.42mm Hi-tensile External / 0.6mm Internal Steel Skins.
Interior Facing Skin 0.5mm, 0.6mm G300 COLORBOND® steel
Maximum uniformly distributed ultimate wind load (kPa) for the given span:
Standard Exterior Colours
Single Span, wind pressure acting outwards
Surfmist® Paperbark® Classic Cream™ Pale Eucalypt®
Panel Thickness (mm)
Span (mm)
50 75 100 125 150 200
1500 5.16 7.70 9.41 10.98 13.26 17.81 Headland®** Dune® Shale Grey™ Jasper®^

2700 2.35 3.74 4.63 5.55 6.78 9.28


3900 1.28 2.00 2.55 3.11 3.67 4.79 Basalt®^ Woodland Grey®^**

5100 - 1.21 1.53 1.86 2.19 2.85


6300 - - 1.04 1.25 1.47 1.91 Interior Facing Colours
7500 - - 0.76 0.92 1.07 1.38 Surfmist®

8700 - - - - 0.82 1.05


Finishes Plain, Elegance
Multi-span, wind pressure acting outwards Acoustic Properties Rw 24-25 depending on thickness
Panel Thickness (mm) Recommended Pitch 2 degrees minimum
Span (mm)
50 75 100 125 150 200
Fire Hazard Properties - AS1530.3 indices
1500 4.15 5.90 7.61 7.74 7.74 7.75
2700 2.07 2.91 1.00 4.35 4.35 4.35 Ignitability Index 0
3900 1.17 1.72 2.41 2.95 3.04 3.05 Spread of Flame Index 0
5100 - 1.11 1.58 1.98 2.35 2.36
Heat Evolved Index 0
6300 - - 1.10 1.40 1.77 1.93
7500 - - - 1.03 1.31 1.64 Smoke Index 2-3
8700 - - - - - 1.43 AS/ISO 9705 - BCA Group Number (Spec C1.10a)
EPS-FR steel skinned insulated building panels conform to the requirements of the BCA Specification
Recommended Uses C1.10a as either Group 2 or Group 1 depending on the thickness and construction detail.
Group 1
House roofing, patios, pergolas, carports, portable buildings, home extensions, spray Panel up to 250mm thick with steel ‘wall-wall’ and ‘wall-ceiling’ angles fixed with steel rivets or
booths, wineries and most insulated roofing applications. screws at 1200mm centres is classified as Group 1.
Group 2
Panel 150mm or less with an aluminium ‘wall-wall’ and ‘wall-ceiling’ angles fixed with aluminium
rivets or screws at 300mm centres is classified as Group 2. Panel thicker than 150mm requires
steel ‘wall-wall’ and ‘wall-ceiling’ angles fixed with steel rivets or screws at 300mm centres to be
classified as Group 2.
NOTES:
1. E xtended span tables including cyclonic regions C&D, multi-span, wind pressure acting inwards
and 0.5mm interior skin are also available. Refer Bondor®.
2. Fixing with 14g tek screws (or equivalent) at each rib are required.
3. Pressures specified are for wind gusts only per AS 1170.
4. D eflection limit of span/150 applies, and in accordance with Serviceability Limit State criteria per
AS1170.0 - TABLE C1.
5. S elf weight of the panel has been allowed for, plus an allowance of max 25kg/m2 uniformly
distributed dead loads (e.g. lights, fans, solar panels, etc.).
6. N on-trafficable maintenance access (concentrated load) of 140kg (exceeding min. requirements of
AS/NZS 1170.1:2002) on any one panel has been allowed for.
7. Distributed live load of 0.25kPa (as per AS/NZS 1170.1:2001) has been allowed for.
8. Min. roof slope of 2 degree applies.
9. Generic engineering certification of the SolarSpan® Patio System is available for residential patios.
** Limited availability.
^ Darker colours warranted for use in limited regions. Check with your local SolarSpan® dealer for
more information.
Technical Data Sheet
EPS-FR BON0126 Bondor Tech Data Sheets. Current as of: 03/03/16

Joint

Services duct

Profiles

Plain

Elegance

Dimensions
25mm 250mm 185mm 20mm
32mm
20mm
Thickness
65mm
1000mm cover width

Bondor® National Network


BRISBANE / EXPORT MELBOURNE SYDNEY
103 Ingram Road 329A St Albans Road 49 – 53 Newton Road
Acacia Ridge QLD 4110 Sunshine VIC 3020 Wetherill Park NSW 2164
T: 07 3323 8500 T: 03 8326 8000 T: 02 9609 0888
F: 07 3323 8501 F: 03 8326 8099 F: 02 9729 1114
PERTH ADELAIDE LAUNCESTON
17 Gauge Circuit 70 – 72 Rundle Road 7 Connector Park Drive
Canning Vale WA 6155 Salisbury South SA 5106 Kings Meadows TAS 7249
T: 08 9256 0600 T: 08 8282 5000 T: 03 6335 8500
F: 08 9256 0620 F: 08 8282 5099 F: 03 6335 8544
To connect to your nearest Bondor® branch simply call 1300 300 099 or visit www.bondor.com.au

Metecno Pty Limited. ABN 44 096 402 934. The manufacturer reserves the right to change the specification without notice. Bondor®,
Equitilt®, BondorPanel®, FlameGuard®, MetecnoPanel®, InsulWall®, SolarSpan®, MetecnoSpan®, Purline®, Equideck®, InsulLiving®, Metecno,
MetecnoSpanTH & MetecnoPanelTH are trademarks of Metecno Pty Limited. BlueScope, COLORBOND®, Permagard® and colour names are
trademarks of BlueScope Steel Limited. Microban® is a registered trade mark of the Microban Products Company. The colours shown in this
publication have been reproduced to represent actual product colours as accurately as possible. However, given printing limitations,
we recommend checking your chosen colour against an actual sample before placing orders. This advice is of a general nature only.
Designers must provide for adequate structural performance and other Building Code requirements. This information is subject to change.
Refer to Bondor® website for latest version. Consult Bondor® for your application. Leaders in Thermal & Architectural Building Solutions